CommScope P-024-MP-CM-F12RD/8W008/5K016
Fiber indoor cable, TeraSPEED® Plenum for MPO Trunks, 24 fiber with 12 fiber subunits, Multimode composite, Feet jacket marking, Red jacket color.
Product Overview
This document details the specifications for the CommScope P-024-MP-CM-F12RD/8W008/5K016 fiber indoor cable, designed for MPO Trunks. It features a TeraSPEED® Plenum jacket, 24 fibers organized into 12 fiber subunits, and a red jacket marking indicating feet.
Representative Image Description: A red fiber optic cable is shown, cut to reveal its internal structure: multiple colorful fiber strands within subunits, encased in a gel-filled jacket.
Product Classification
Category | Detail |
---|---|
Regional Availability | Asia | Australia/New Zealand | Latin America | Middle East /Africa | North America |
Portfolio | CommScope® |
Product Type | Fiber indoor cable |
Product Series | P-MP |
General Specifications
Specification | Value |
---|---|
Cable Type | MPO trunk cable |
Construction Type | Non-armored |
Subunit Type | Gel-free |
Jacket Color | Red |
Jacket Marking | Feet |
Subunit, quantity | 2 |
Fibers per Subunit, quantity | 12 |
Composite Fiber Count | 8 + 16 |
Total Fiber Count | 24 |
Dimensions
Dimension | Value (Metric | Imperial) |
---|---|
Height Over Jacket | 3.9 mm | 0.154 in |
Width Over Jacket | 6.9 mm | 0.272 in |
Buffer Tube/Subunit Diameter | 3 mm | 0.118 in |
Mechanical Specifications
Specification | Value |
---|---|
Minimum Bend Radius, loaded | 58 mm | 2.283 in |
Minimum Bend Radius, unloaded | 39 mm | 1.535 in |
Tensile Load, long term, maximum | 200 N | 44.962 lbf |
Tensile Load, short term, maximum | 667 N | 149.948 lbf |
Compression | 10 N/mm | 57.101 lb/in |
Compression Test Method | FOTP-41 | IEC 60794-1 E3 |
Flex | 300 cycles |
Flex Test Method | FOTP-104 | IEC 60794-1 E6 |
Impact | 0.74 N-m | 6.55 in lb |
Impact Test Method | FOTP-25 | IEC 60794-1 E4 |
Strain | See long and short term tensile loads |
Strain Test Method | FOTP-33 | IEC 60794-1 E1 |
Twist | 10 cycles |
Twist Test Method | FOTP-85 | IEC 60794-1 E7 |
Vertical Rise, maximum | 500 m | 1,640.42 ft |
Optical Specifications
Specification | Value |
---|---|
Fiber Type | Composite MM/SM | G.652.D and G.657.A1, TeraSPEED® | OM4, LazrSPEED® 550 | OS2 | OS2 |
Environmental Specifications
Specification | Value |
---|---|
Installation temperature | 0 °C to +70 °C (+32 °F to +158 °F) |
Operating Temperature | 0 °C to +70 °C (+32 °F to +158 °F) |
Storage Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
Cable Qualification Standards | ANSI/ICEA S-83-596 | Telcordia GR-409 |
Environmental Space | Plenum |
Flame Test Listing | NEC OFNP (ETL) and c(ETL) |
Flame Test Method | NFPA 262 |
Environmental Test Specifications
Specification | Value |
---|---|
Heat Age | 0 °C to +85 °C (+32 °F to +185 °F) |
Heat Age Test Method | IEC 60794-1 F9 |
Low High Bend | 0 °C to +70 °C (+32 °F to +158 °F) |
Low High Bend Test Method | FOTP-37 | IEC 60794-1 E11 |
Temperature Cycle | 0 °C to +70 °C (+32 °F to +158 °F) |
Temperature Cycle Test Method | FOTP-3 | IEC 60794-1 F1 |
Packaging and Weights
Specification | Value |
---|---|
Cable weight | 29 kg/km | 19.487 lb/kft |
Regulatory Compliance/Certifications
Agency | Classification |
---|---|
ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system |
Included Products
- CS-5K-MP: LazrSPEED® 550 OM4 Bend-Insensitive Multimode Fiber
- CS-8W-MP: TeraSPEED® OS2 Singlemode Fiber
CS-5K-MP Specifications
Product Classification
Category | Detail |
---|---|
Portfolio | CommScope® |
Product Type | Optical fiber |
General Specifications
Specification | Value |
---|---|
Cladding Diameter | 125 μm |
Cladding Diameter Tolerance | ±5 μm |
Cladding Non-Circularity, maximum | 1 % |
Coating Diameter (Colored) | 254 μm |
Coating Diameter (Uncolored) | 245 μm |
Coating Diameter Tolerance (Colored) | ±7 μm |
Coating Diameter Tolerance (Uncolored) | ±10 μm |
Coating/Cladding Concentricity Error, maximum | 12 μm |
Core Diameter | 50 μm |
Core Diameter Tolerance | ±2.5 μm |
Core/Clad Offset, maximum | 1.5 μm |
Proof Tensile Stress | 100,000 psi (0.69 GPa) |
Mechanical Specifications
Specification | Value |
---|---|
Macrobending, 15 mm Ø mandrel, 2 turns | 0.20 dB @ 850 nm | 0.50 dB @ 1,300 nm |
Macrobending, 30 mm Ø mandrel, 2 turns | 0.10 dB @ 850 nm | 0.30 dB @ 1,300 nm |
Macrobending, 75 mm Ø mandrel, 100 turns | 0.50 dB @ 1,300 nm | 0.50 dB @ 850 nm |
Coating Strip Force, maximum | 8.9 N | 2.001 lbf |
Coating Strip Force, minimum | 1.3 N | 0.292 lbf |
Dynamic Fatigue Parameter, minimum | 18 |
Optical Specifications
Specification | Value |
---|---|
Numerical Aperture | 0.2 |
Numerical Aperture Tolerance | ±0.015 |
Point Defects, maximum | 0.15 dB |
Zero Dispersion Slope, maximum | 0.105 ps/[km-nm-nm] |
Zero Dispersion Wavelength, maximum | 1316 nm |
Zero Dispersion Wavelength, minimum | 1297 nm |
Optical Specifications, Wavelength Specific
Specification | Value |
---|---|
1 Gbps Ethernet Distance | 1,110 m @ 850 nm | 600 m @ 1,300 nm |
10 Gbps Ethernet Distance | 550 m @ 850 nm |
Attenuation, maximum | 1.00 dB/km @ 1,300 nm | 3.00 dB/km @ 850 nm |
Backscatter Coefficient | -68.0 dB @ 850 nm | -75.7 dB @ 1,300 nm |
Bandwidth, Laser, minimum | 4,700 MHz-km @ 850 nm | 500 MHz-km @ 1,300 nm |
Bandwidth, OFL, minimum | 3,500 MHz-km @ 850 nm | 500 MHz-km @ 1,300 nm |
Differential Mode Delay | 0.70 ps/m @ 850 nm |
Differential Mode Delay Note | Superior to ANSI/TIA TIA-492AAAF and IEC 60793-2-10 at 850 nm |
Index of Refraction | 1.479 @ 1,300 nm | 1.483 @ 850 nm |
Standards Compliance | ANSI/TIA-492AAAF (OM4) | IEC 60793-2-10, A1 (OM4) |
Environmental Specifications
Specification | Value |
---|---|
Heat Aging, maximum | 0.20 dB/km @ 85 °C |
Temperature Dependence, maximum | 0.1 dB/km |
Temperature Humidity Cycling, maximum | 0.2 dB/km |
Water Immersion, maximum | 0.20 dB/km @ 23 °C |
Regulatory Compliance/Certifications
Agency | Classification |
---|---|
ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system |
CS-8W-MP Specifications
Product Classification
Category | Detail |
---|---|
Portfolio | CommScope® |
Product Type | Optical fiber |
General Specifications
Specification | Value |
---|---|
Cladding Diameter | 125 μm |
Cladding Diameter Tolerance | ±0.7 μm |
Cladding Non-Circularity, maximum | 0.7 % |
Coating Diameter (Colored) | 249 μm |
Coating Diameter (Uncolored) | 242 μm |
Coating Diameter Tolerance (Colored) | ±13 μm |
Coating Diameter Tolerance (Uncolored) | ±5 μm |
Coating/Cladding Concentricity Error, maximum | 12 μm |
Core Diameter | 8.3 μm |
Core/Clad Offset, maximum | 0.5 μm |
Proof Tensile Stress | 100,000 psi (0.69 GPa) |
Dimensions
Dimension | Value |
---|---|
Fiber Curl, minimum | 4 m | 13.123 ft |
Mechanical Specifications
Specification | Value |
---|---|
Macrobending, 20 mm Ø mandrel, 1 turn | 0.75 dB @ 1,550 nm | 1.50 dB @ 1,625 nm |
Macrobending, 30 mm Ø mandrel, 10 turns | 0.25 dB @ 1,550 nm | 1.00 dB @ 1,625 nm |
Macrobending, 60 mm Ø mandrel, 100 turns | 0.05 dB @ 1,550 nm | 0.05 dB @ 1,625 nm |
Coating Strip Force, maximum | 8.9 N | 2.001 lbf |
Coating Strip Force, minimum | 1.3 N | 0.292 lbf |
Dynamic Fatigue Parameter, minimum | 20 |
Optical Specifications
Specification | Value |
---|---|
Cabled Cutoff Wavelength, maximum | 1260 nm |
Point Defects, maximum | 0.1 dB |
Zero Dispersion Slope, maximum | 0.092 ps/[km-nm-nm] |
Zero Dispersion Wavelength, maximum | 1324 nm |
Zero Dispersion Wavelength, minimum | 1300 nm |
Optical Specifications, Wavelength Specific
Specification | Value |
---|---|
Attenuation, maximum | 0.40 dB/km @ 1,310 nm | 0.40 dB/km @ 1,385 nm | 0.40 dB/km @ 1,490 nm | 0.40 dB/km @ 1,550 nm | 0.50 dB/km @ 1,270 nm | 0.50 dB/km @ 1,575 nm |
Backscatter Coefficient | -79.6 dB @ 1,310 nm | -82.1 dB @ 1,550 nm |
Dispersion, maximum | 18 ps(nm-km) at 1550 nm | 3.5 ps(nm-km) from 1285 nm to 1330 nm at 1310 nm |
Index of Refraction | 1.467 @ 1,310 nm | 1.467 @ 1,385 nm | 1.468 @ 1,550 nm |
Mode Field Diameter | 10.4 μm @ 1,550 nm | 9.2 μm @ 1,310 nm | 9.6 μm @ 1,385 nm |
Mode Field Diameter Tolerance | ±0.4 μm @ 1310 nm | ±0.5 μm @ 1550 nm | ±0.6 μm @ 1385 nm |
Polarization Mode Dispersion Link Design Value, maximum | 0.06 ps/sqrt(km) |
Standards Compliance | ITU-T G.652.D | ITU-T G.657.A1 | TIA-492CAAB (OS2) |
Environmental Specifications
Specification | Value |
---|---|
Heat Aging, maximum | 0.05 dB/km @ 85 °C |
Temperature Dependence, maximum | 0.05 dB/km |
Temperature Humidity Cycling, maximum | 0.05 dB/km |
Water Immersion, maximum | 0.05 dB/km @ 23 °C |
Regulatory Compliance/Certifications
Agency | Classification |
---|---|
ISO 9001:2015 | Designed, manufactured and/or distributed under this quality management system |
Footnotes
- Operating Temperature
- Specification applicable to non-terminated bulk fiber cable
- Temperature Dependence, maximum
- Temperature dependence is conducted at -60 °C to +85 °C (-76 °F to +185 °F)
- Temperature Humidity Cycling, maximum
- Temperature humidity cycling is conducted at -10 °C to +85 °C (+14 °F to +185 °F) up to 95% relative humidity