Fitting Time: 0 Hours, 15 Minutes
A line drawing of a Steel Wire Mesh Window Protector.
A line drawing of an Aluminium Mesh Window Protector.
⚠ Installation of this accessory requires the use of power tools. Check that all work practices comply with safety standards, wear appropriate clothing and use personal protection equipment.
⚠ Please read these instructions carefully before installation, paying special attention to all Notice, Caution & Warning notes. Failure to do so may result in damaged parts or injury to the installer or customer.
Issue 1: 25/06/2024 | Document No.: 9PEWP-FI | Page 1 of 3
Kit Contents
NOTE: CHECK KIT CONTENTS BEFORE COMMENCING FITMENT AND REPORT ANY DISCREPANCIES
Item | Description | Qty |
---|---|---|
1 | Window Protector - Welded Steel | 1 |
2 | M6x40 Counter-sunk Philips Head Screw | 4 |
3 | M6 Nyloc Nut | 4 |
A diagram showing the components of the steel wire mesh kit, labeled with numbers 1, 2, and 3 corresponding to the items.
Item | Description | Qty |
---|---|---|
1 | Window Protector - Alloy Mesh | 1 |
2 | M6x40 Hex Bolt | 4 |
3 | M6 Nyloc Nut | 4 |
A diagram showing the components of the aluminium mesh kit, labeled with numbers 1, 2, and 3 corresponding to the items.
Tools Required
Tools Required | Specification |
---|---|
Cordless Drill | 6.5mm Drill Bit |
10mm Socket | 10mm Spanner |
Ratchet | Philips Head Screw Driver |
Fastener Torque Table
Fastener size | Class | Torque |
---|---|---|
M6 | 8.8 | 9 Nm |
SECTION 1—Installation
STEP 1
Position window protector to allow minimum 25mm clearance from the headboard whilst still covering as much of the rear window as possible.
Diagram illustrating the positioning of the Welded Steel Window Protector, showing a minimum 25mm clearance from the headboard.
⚠ NOTE: If Vehicle has Third Brake Light
If the vehicle is fitted with a CHMSL (Center High Mounted Stop Lamp) ensure the top of the window protector sits 25mm below the bottom of the lamp. The brake light must not be blocked by the window protector.
Diagram showing the positioning of the Welded Steel Window Protector relative to a CHMSL (Center High Mounted Stop Lamp), indicating a 25mm clearance below the lamp.
Mark the hole locations on the headboard uprights and drill 6.5mm holes.
STEP 2
Fasten the window protector to the headboard uprights using M6x40 counter sunk screws and M6 nyloc nuts. For alloy mesh window protectors use M6x40 bolts and M6 nyloc nuts.
Illustration showing the attachment of the Window Protector to the headboard uprights using an M6x40 counter-sunk screw and an M6 Nyloc Nut.
Issue 1: 25/06/2024 | Page 3 of 3