2BH5BKRFTP-B Touch Screen Control Panel
Product Overview
The device is a touch screen control panel for thermostats. The display shows the current temperature as 76°F and the set temperature as 62°F. It also displays the time as 12:01 PM. Various operational modes and settings are indicated, including System, Fan, Heat, Auto, Schedule, and Leave. Control buttons are visible for adjusting settings like Mode, Set to, Fan, Schedule, and Leave, along with up and down arrow buttons for temperature adjustment.
Specifications
- Supply Voltage: 24V, 50-60Hz Rating: 0.5A
- Wireless operation: RF Connect Button
- Working frequency: 915.055 MHz
- Working distance: 30 Meters
- Heat pump control (Heating and Cooling).
- Touch Screen interface.
- Temperature Display Range: 41°F to 95°F (5°C to 35°C)
- Temperature Control Range: 44°F to 90°F (07° C to 32°C)
- Display Accuracy: ± 1°F
- Optimal Start/Stop: This feature involves algorithmically starting or stopping the system in advance. Optimal Start ensures that the set temperature is reached at the scheduled time, while Optimal Stop shuts down the system early upon PROG transition to achieve energy savings.
- Deadband: Adjustable 4 to 6 Degrees. (Default 5)
- aDifferential: adjustable from 0.5°F to 2.0°F (Default 1°F)
- 2nd Stage Offset: adjustable from 2°F to 5°F (Default 3°F)
- Boost Emergency Heat Stage (Electric) Time Variable: 5 minutes and 30 minutes (default 15 min)
- Factory program setting: 5+2/5+1+1 (Default: 5+2)
Warning
- Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment.
- To comply with FCC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons.
- This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Wiring Diagram
The wiring diagram illustrates a connection from a "24Vac~ 24V Class II Power Transformer" to the device's terminals labeled "R" and "C".
Dimensions (unit: mm)
The physical dimensions of the device are provided. The front panel has a width of 94 mm and a height of 29.10 mm. The main body of the unit measures 122 mm in length, 83.60 mm in width, and 31.50 mm in height.