Ruud Endeavor ® Line Achiever Plus ® Series Side-Discharge Universal Heat Pump

Model: RD17AZ

Key Specifications

Note: Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR®. Visit www.energystar.gov for details.

Features and Benefits

1 Based on Internal R&D Testing, 2023. Sound levels are also dependent on proper installation and location of outdoor product.
2 When installed as part of a complete AHRI-matched, Rheem EcoNet® Enabled system.
3 The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Rheem® is under license. Other trademarks and trade names are those of their respective owners.
4 When installed as part of a complete Rheem system where both the outdoor & indoor components feature Bluetooth® Technology.
5 Two-Stage (70% & 100% capacity) operation when installed with legacy and other thermostats when the utility 1 & 2 jumpers are not installed. The 2-Ton model features a single rotary compressor.

Model Number Identification

The model number indicates key product features:

R D 17 A Z 24 A J 3 N A
Brand (Ruud) Product Category (Side-Discharge Heat Pump) SEER2 (17 SEER2) Region (All Regions) Refrigerant (R-410A) Capacity (24=24,000 BTU/H, 36=36,000 BTU/H, 48=48,000 BTU/H, 60=60,000 BTU/H) Major Series (1st Design) Voltage (208/230-1-60) Type (3+ Stage) Controls (Non-Communicating) Minor Series (1st Series)

Available Models:

Note: RD17AZ models are communicating when installed as part of a complete AHRI-matched, Ruud EcoNet ® Enabled System.

Standard Equipment

General Data

MODEL NO. RD17AZ24AJ3NA RD17AZ36AJ3NA RD17AZ48AJ3NA RD17AZ60AJ3NA
Nominal Tonnage 2.0 T 3.0 T 4.0 T 5.0 T
Valve Connections
Liquid Line O.D. - in. 3/8 3/8 3/8 3/8
Suction Line O.D. - in. 3/4 3/4 7/8 7/8
Refrigerant (R-410A) furnished oz. 1 81 116 222 236
Compressor Type Rotary Rotary Rotary Rotary
Outdoor Coil
Net face area - Outer Coil (Sq. Ft.) 11.0 15.1 17.2 17.2
Net face area - Inner Coil (Sq. Ft.) N/A 15.1 17.2 17.2
Tube diameter - in. 0.276 0.276 0.276 0.276
Number of rows 1 2 3 3
Fins per inch 18 18 16 16
Outdoor Fan
Diameter - in. 26 28 24 24
Number of blades 3 3 3 3
Motor hp 1/2 1/2 1/3 1/3
Nos 1 1 2 2
CFM 3175 3575 5150 5600
RPM 550 570 650 700
Watts 115 215 315 365
Shipping weight - lbs. 205 271 354 356
Operating weight - lbs. 146 200 278 280

1 Refrigerant charge sufficient for 25 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.

Electrical Data

Line Voltage Data (Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60
Maximum overcurrent protection (amps) 2 20.0 25.0 40.0 45.0
Minimum circuit ampacity 3 19.0 24.5 38.0 41.0
Compressor
Rated load amps 9.7 10.4 17.0 22.0
Locked rotor amps 25 52 51 51
Condenser Fan Motor
Full load amps 3.0 3.0 2.5 2.5
Locked rotor amps 6.4 6.4 4.1 4.1

2 HACR type circuit breaker of fuse.
3 Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.

Accessories

MODEL NO. RD17AZ24AJ3NA RD17AZ36AJ3NA RD17AZ48AJ3NA RD17AZ60AJ3NA
Compressor crankcase heater* 44-103663-15 44-103663-15 44-103663-15 44-103663-15
Basepan heater 44-109957-01 44-109958-01 44-109957-01 44-109957-01
Low ambient control Included Standard Included Standard Included Standard Included Standard
Compressor sound cover Included Standard Included Standard Included Standard Included Standard
Compressor hard start kit N/A N/A N/A N/A
Low pressure control Included Standard Included Standard Included Standard Included Standard
High pressure control Included Standard Included Standard Included Standard Included Standard
Liquid Line Solenoid (24 VAC, 50/60 Hz) Solenoid Valve: 200RD2T3TVLC
Solenoid Coil: 61-AMG24V
Solenoid Valve: 200RD2T3TVLC
Solenoid Coil: 61-AMG24V
Solenoid Valve: 200RD2T3TVLC
Solenoid Coil: 61-AMG24V
Solenoid Valve: 200RD2T3TVLC
Solenoid Coil: 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz) Solenoid Valve: 200RD2T3TVLC
Solenoid Coil: 61-AMG120/240V
Solenoid Valve: 200RD2T3TVLC
Solenoid Coil: 61-AMG120/240V
Solenoid Valve: 200RD2T3TVLC
Solenoid Coil: 61-AMG120/240V
Solenoid Valve: 200RD2T3TVLC
Solenoid Coil: 61-AMG120/240V

Weighted Sound Power Level (dBA)

UNIT SIZE - VOLTAGE, SERIES SOUND PRESSURE AS LOW AS SOUND POWER AS LOW AS TYPICAL OCTAVE BAND SPECTRUM (dBA WITHOUT TONE ADJUSTMENT)
125 250 500 1000 2000 4000 8000
RD17AZ24 53 61 45.0 54.7 57.5 58.2 53.9 46.7 38.1
RD17AZ36 50 58 44.7 60.8 62.3 57.2 53.9 54.5 44.8
RD17AZ48 54 61 54.0 58.6 63.8 64.9 60.4 54.8 44.9
RD17AZ60 55 63 53.5 59.0 62.6 63.3 57.9 50.4 44.8

Note: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).

Unit Dimensions

RD17AZ Series Unit Dimensions (Inches [mm])

MODEL NO. H W L A B C D E F
RD17AZ24AJ3NA 36.6 [930] 40.4 [1026] 19.8 [503] 43.31 [1100] 48.43 [1230] 50.00 [1270] 22.8 [578] 65.16 [1655] 48.43 [1230]
RD17AZ36AJ3NA 46.4 [1178] 40.4 [1026] 19.8 [503] 53.94 [1370] 50.00 [1270] 50.00 [1270] 22.8 [578] 65.16 [1655] 48.43 [1230]
RD17AZ48AJ3NA 58.0 [1473] 40.4 [1026] 19.8 [503] 65.16 [1655] 48.43 [1230] 50.00 [1270] 22.8 [578] 65.16 [1655] 48.43 [1230]
RD17AZ60AJ3NA 58.0 [1473] 40.4 [1026] 19.8 [503] 65.16 [1655] 48.43 [1230] 50.00 [1270] 22.8 [578] 65.16 [1655] 48.43 [1230]

Illustration showing the unit with labels for Height (H), Width (W), Length (L), and service access points.

Allowable Clearances

Single Unit Installations

RD17AZ24, RD17AZ36

OBSTRUCTION MIN. CLEARANCE (IN.)
REAR COIL SIDE FRONT SERVICE PANEL
Open Space Above 4 12 48 10
12 4 48 10
12 12 24 10
4 12 24 10
Obstruction Above, Less Than 40° 12 12 48 10
20 4 24 10

RD17AZ48, RD17AZ60

OBSTRUCTION MIN. CLEARANCE (IN.)
REAR COIL SIDE FRONT SERVICE PANEL
Open Space Above 6 8 60 10
12 8 60 10
12 12 40 10
6 12 40 10
Obstruction Above, Less Than 40° 12 12 48 10
20 4 60 10

Multiple Unit Installations

Diagram showing recommended clearances for multiple unit installations.

IMPORTANT: Consult local and national building codes and ordinances for special installation requirements. Following location information will provide longer life and simplified servicing of the outdoor heat pump.

NOTICE: These units must be installed outdoors. No ductwork can be attached, or other modifications made, to the discharge grille. Modifications will affect performance or operation.

Refrigerant Line Size Information

Diagram illustrating refrigerant line sizing based on unit size, vertical separation, and equivalent length.

NOTES:

  1. Do not exceed 150 ft. linear line length.
  2. Do not exceed 50 ft. vertical separation between indoor and outdoor units.
  3. "3/4" vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
  4. "1-1/8" vapor line should only be used for 5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
  5. Always use the smallest liquid line allowable to minimize refrigerant charge.
  6. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  7. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
UNIT SIZE ALLOWABLE LIQUID LINE SIZE ALLOWABLE VAPOR LINE SIZE OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (FEET)
< 25 26-50 51-75 76-100 101-125 126-150
2 TON 1/4" 5/8" 25/1.00 50/0.99 33/0.98 50/0.97 50/0.96 NR
5/16" 5/8" 25/1.00 50/0.99 50/0.98 50/0.97 50/0.96 50/0.99
2.5 TON *SEE NOTE 3* 3/8" 5/8" 25/1.00 50/0.99 50/0.98 50/0.97 50/0.96 50/0.99
1/4" 3/4"** 25/1.00 50/0.99 33/0.98 50/0.97 50/0.96 50/0.99
3 TON 5/16" 3/4"** 25/1.00 50/0.99 50/0.98 50/0.97 36/0.97 NR
3/8" 3/4"** 25/1.00 50/0.99 50/0.98 50/0.97 36/0.97 NR
3.5 TON 3/8" 5/8" 25/1.00 50/0.95 50/0.97 50/0.93 50/0.91 NR
5/16" 3/4" 25/1.00 50/0.95 50/0.97 50/0.95 36/0.97 NR
4 TON 3/8" 3/4" 25/1.00 50/0.98 50/0.96 50/0.95 50/0.93 50/0.93
1/2" 3/4" 25/1.00 50/0.99 50/0.98 50/0.97 50/0.97 50/0.98
4.5 TON 3/8" 3/4" 25/1.00 50/0.95 50/0.97 50/0.95 46/0.91 NR
1/2" 3/4" 25/1.00 50/0.95 50/0.97 50/0.95 50/0.91 NR
5 TON 3/8" 7/8" 25/1.00 50/0.99 50/0.98 50/0.97 50/0.96 38/0.96
1/2" 7/8" 25/1.00 50/0.98 50/0.98 50/0.97 50/0.96 50/0.99
5 TON 3/8" 1-1/8"** 25/1.00 50/1.00 50/1.00 50/0.99 50/0.99 50/0.99

Refrigerant Line Size Information (Con't.)

Diagram illustrating refrigerant line sizing based on unit size, vertical separation, and equivalent length in meters.

NOTES:

  1. Do not exceed 46 meters linear line length.
  2. Do not exceed 15 meters vertical separation between indoor and outdoor units.
  3. *19.05 mm [3/4 in.] vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
  4. **28.58 mm [1-1/8 in.] vapor line should only be used for 5 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
  5. Always use the smallest liquid line allowable to minimize refrigerant charge.
  6. Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
  7. Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
UNIT SIZE ALLOWABLE LIQUID LINE SIZE ALLOWABLE VAPOR LINE SIZE OUTDOOR UNIT ABOVE OR BELOW INDOOR UNIT EQUIVALENT LENGTH (METERS)
< 8 9-15 16-23 24-31 32-38 39-46
2.0 TON [6.0 kW] *SEE NOTE 3* 6.35 [1/4] 15.88 [5/8] 8/1.00 15/0.98 10/0.98 20/0.97 NR NR
7.94 [5/16] 15.88 [5/8] 8/1.00 15/0.99 15/0.98 15/0.97 15/0.96 15/0.96
2.5 TON [7.3 kW] 7.94 [5/16] 19.05 [3/4] 8/1.00 15/0.99 15/0.98 20/0.99 NR NR
9.53 [3/8] 15.88 [5/8] 8/1.00 15/0.99 15/0.97 15/0.97 15/0.97 15/0.97
3.0 TON [8.8 kW] 9.53 [3/8] 19.05 [3/4] 8/1.00 15/0.99 15/0.98 15/0.97 15/0.97 15/0.97
7.94 [5/16] 19.05 [3/4] 8/1.00 15/0.99 15/0.98 15/0.97 15/0.97 15/0.97
3.5 TON [10.3 kW] 9.53 [3/8] 15.88 [5/8] 8/1.00 15/0.95 15/0.97 15/0.95 15/0.93 15/0.91
7.94 [5/16] 19.05 [3/4] 8/1.00 15/0.95 15/0.97 15/0.95 15/0.93 15/0.91
4.0 TON [11.7 kW] 9.53 [3/8] 19.05 [3/4] 8/1.00 15/0.98 15/0.96 15/0.95 15/0.93 15/0.93
12.70 [1/2] 19.05 [3/4] 8/1.00 15/0.99 15/0.98 15/0.97 15/0.97 15/0.98
4.5 TON [13.2 kW] 9.53 [3/8] 19.05 [3/4] 8/1.00 15/0.95 15/0.96 15/0.95 14/0.91 15/0.93
12.70 [1/2] 19.05 [3/4] 8/1.00 15/0.95 15/0.97 15/0.95 15/0.93 15/0.91
5.0 TON [14.7 kW] 9.53 [3/8] 22.23 [7/8] 8/1.00 15/0.98 15/0.98 15/0.97 15/0.96 15/0.96
12.70 [1/2] 19.05 [3/4] 8/1.00 15/0.95 15/0.97 15/0.95 15/0.93 15/0.91
5.0 TON [17.6 kW] 9.53 [3/8] 28.58 [1-1/8]** 8/1.00 15/0.95 15/0.97 15/0.95 15/0.93 15/0.91
5.0 TON [17.6 kW] 12.70 [1/2] 28.58 [1-1/8]** 8/1.00 15/0.99 15/0.99 15/0.99 15/0.99 15/0.99

Performance Data @ AHRI Standard Conditions - Cooling

OUTDOOR UNIT COIL COOLING PERFORMANCE SEER2 EER2 INDOOR CFM [L/S] HEATING PERFORMANCE REGION IV HSPF2
TOTAL CAPACITY BTU/H [KW] NET SENSIBLE BTU/H [KW] NET LATENT BTU/H [KW] 47 DEGREE HEATING CAPACITY BTU/H [KW] 47 DEGREE COP 17 DEGREE HEATING CAPACITY BTU/H [KW] 17 DEGREE COP
RD17AZ24AJ3NA RCFZ2417MTANMC 22,800 [6.7] 16,880 [5.0] 5,920 [1.7] 14.3 9.8 750 [354] 22,800 [6.7] 3.30 16,000 [4.7] 2.56 7.5
RD17AZ36AJ3NA RCFZ3621MTANMC 34,200 [10.0] 24,238 [7.1] 9,962 [2.9] 14.3 9.8 1,025 [484] 34,200 [10.0] 3.48 23,000 [6.7] 2.62 7.5
RD17AZ48AJ3NA RCFZ4824MTANMC 45,000 [13.2] 31,760 [9.3] 13,240 [3.9] 14.3 9.8 1,250 [590] 45,000 [13.2] 3.42 33,000 [6.7] 2.66 7.5
RD17AZ60AJ3NA RCFZ6024STANMC 53,000 [15.5] 36,263 [10.6] 16,737 [4.9] 14.3 9.8 1,450 [684] 53,000 [15.5] 3.36 36,500 [10.7] 2.50 7.5
RD17AZ24AJ3NA RH3VZ3617STACNJ 22,600 [6.6] 17,500 [5.1] 5,300 [1.6] 17.0 11.7 725 [342.0] 22,600 [6.6] 2.90 18,700 [5.5] 2.5 9.5
RD17AZ36AJ3NA RH3VZ4821STACNJ 34,200 [10.0] 26,200 [7.7] 8,000 [2.3] 18.0 11.7 1,050 [495.0] 34,200 [10.0] 2.78 31,200 [9.1] 2.3 8.1
RD17AZ48AJ3NA RH3VZ6024STACNJ 45,500 [13.3] 34,900 [10.2] 10,600 [3.1] 17.0 11.7 1,375 [649.0] 45,500 [13.3] 2.94 43,000 [12.6] 2.4 8.1
RD17AZ60AJ3NA RH3VZ6024STACNJ 55,500 [16.3] 42,600 [12.5] 12,900 [3.8] 19.0 10.0 1,500 [707.9] 53,500 [15.7] 2.32 50,000 [14.7] 2.0 8.1

Note: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match-ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.

GENERAL TERMS OF LIMITED WARRANTY*

Ruud will furnish a replacement for any part of this product that fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.

Conditional Parts (Registration Required)

Ten (10) Years

Applies to a heat pump only or system installation. Does not require the heat pump to be part of a properly matched system as specified by the Manufacturer and the Air Conditioning Heating & Refrigeration Institute (AHRI).

Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices.

© 2025 Rheem Manufacturing Company. Ruud trademarks owned by Rheem Manufacturing Company.

In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.

PDF preview unavailable. Download the PDF instead.

CEC9E57C-39F6-46BD-93FF-95239783AF34 Adobe InDesign 20.3 (Macintosh) Adobe PDF Library 17.0

Related Documents

Preview Ruud Endeavor Line Achiever Plus Series Side-Discharge Heat Pump RD16AY
Detailed specifications and features of the Ruud RD16AY Endeavor Line Achiever Plus Series Side-Discharge Heat Pump, including cooling and heating efficiencies, capacities, refrigerant type, unit dimensions, clearances, and warranty information.
Preview Ruud Endeavor Line Achiever Series iM Heat Pumps RP14AY - Product Specifications and Features
Detailed specifications, features, and performance data for the Ruud Endeavor Line Achiever Series iM Heat Pumps, model RP14AY. Includes information on cooling and heating efficiencies, capacities, refrigerant type, unit dimensions, and warranty.
Preview Ruud Endeavor Line Ultra Series Side-Discharge Universal Heat Pump RD18AY
Detailed specifications and features of the Ruud Endeavor Line Ultra Series Side-Discharge Universal Heat Pump, model RD18AY. Includes information on efficiency, capacities, dimensions, clearances, refrigerant line sizing, performance data, and limited warranty.
Preview Ruud Endeavor Line Achiever Plus Series iM Air Conditioners: RA15AZ Technical Specifications and Features
Explore the Ruud Endeavor Line Achiever Plus Series iM Air Conditioners (RA15AZ models) with 15.2 SEER2 efficiency. This document provides detailed features, specifications, dimensions, control wiring, performance data, and EcoNet Smart Thermostat integration for 2 to 5 ton units.
Preview Ruud RA14AZ Endeavor Achiever Series iM Air Conditioner: High Efficiency Cooling
Explore the Ruud RA14AZ Endeavor Achiever Series iM Air Conditioner, featuring up to 14.3 SEER2 efficiency, robust design, and enhanced serviceability for optimal home comfort. Discover key specifications and benefits.
Preview Ruud Endeavor RD16AY Side-Discharge Heat Pump: Efficiency and Comfort
Explore the Ruud Endeavor RD16AY Side-Discharge Heat Pump, offering efficient heating and cooling, compact design, advanced features like EcoNet and Bluetooth, and ENERGY STAR certification for modern homes.
Preview Ruud Endeavor® Line Achiever® Series iM Air Conditioners RA14AY Product Overview
Detailed specifications, features, performance data, and installation clearances for the Ruud Endeavor® Line Achiever® Series iM Air Conditioners, model RA14AY, featuring R-454B refrigerant.
Preview RUUD Endeavor Line Achiever Plus Series iM Heat Pumps RP15AZ
RUUD Endeavor Line Achiever Plus Series iM Heat Pumps RP15AZ product specifications, features, dimensions, and performance data.