* Picture shown here is for reference only. This manual contains the product's basic information, safety, maintenance, replaceable parts, fault diagnosis and basic troubleshooting procedures.

TABLE OF CONTENTS

Introduction

2

Safety

2

Handling the device

3

Handling Electrical Cables

3

Maintenance

4

Cleaning of Filter Screen

4

Panel Surface Cleaning

4

Fan Motor

4

Replacable Parts List

5

Troubleshooting

6

Error Code of Display Board

7

Specifications

7

Circuit Diagram of Outdoor Unit and Panel

7

Introduction

This document provides an overview on replaceable parts for Furrion® 9K & 12K BTU Air Conditioner and Air Distribution Box with LED and Remote Control (AU), as well as basic troubleshooting and service information.
NOTE: Images used in this document are for reference only when assembling, installing and/or operating this product. Actual appearance of provided and/or purchased parts and assemblies may differ. For more detailed operation see Instruction Manual at https:// lci-support-doc.s3.amazonaws.com/Furrion/ccd-0005745.pdf or scan this QR code:

Safety

Read and understand all instructions before installing or operating this product. Adhere to all safety labels.
This manual provides general instructions. Many variables can change the circumstances of the instructions, i.e., the degree of difficulty, operation and ability of the individual performing the instructions. This manual cannot begin to plot out instructions for every possibility, but provides the general instructions, as necessary, for effectively interfacing with the device, product or system. Failure to correctly follow the provided instructions may result in death, serious personal injury, severe product and/or property damage, including voiding of the Lippert limited warranty.

The "WARNING" symbol above is a sign that a procedure has a safety risk involved and may cause death or serious personal injury if not performed safely and within the parameters set forth in this manual.

Failure to follow instructions provided in this manual may result in death, serious personal injury and/or severe product and property damage, including voiding of the component warranty.

The "CAUTION" symbol above is a sign that a safety risk is involved and may cause personal injury and/or product or property damage if not safely adhered to and within the parameters set forth
in this manual.

Rev: 02.17.25

Page 2

CCD-0008084

Always wear eye protection when performing service, maintenance or installation procedures. Other safety equipment to consider would be hearing protection, gloves and possibly a full face
shield, depending on the nature of the task.
Handling the device

Installation and repair of the rooftop air conditioner must only be carried out by qualified personnel who are familiar with the risks involved and the relevant regulations. Inadequate repairs may cause
serious hazards.
Electrical devices are not toys. Keep electrical devices out of reach of children or elderly persons. Do not allow them to use electrical devices without supervision.
Prevent inexperienced people from using the device without supervision.
Do not undo the upper cover of the rooftop air conditioner in the event of a fire. Use approved extinguishing agents instead. Do not use water to extinguish fires.
The rooftop air conditioner must be installed securely so that it cannot fall down.
Only operate the rooftop air conditioner if you are certain that the housing and the cables are not damaged.
Do not use the rooftop air conditioner near flammable fluids or in closed rooms.
Make sure no combustible objects are stored or installed near the air outlet. A distance of at least 20" must be kept.
Do not reach into air outlets or insert any foreign objects into the device. · Only use the device as intended. · Do not make any alterations or conversions to the device. · If faults occur in the refrigerant circuit, the system must be checked by a certified service technician and
repaired properly. The refrigerant must never be released into the air.
Handling Electrical Cables
The electrical power supply must only be connected by a qualified electrician.

Rev: 02.17.25

Page 3

CCD-0008084

Refer to NEC (National Electric Code) for proper sizing of wire gauge (awg) based on cable length and overcurrent protection rating that is suppling power to the air conditioner.
See rooftop unit nameplate for proper overcurrent protection sizing.
Attach and lay the cables so that they cannot be tripped over or damaged.
· Only a qualified electrician should connect the rooftop air conditioner to electrical power. · Do not lay loose or bent cables next to electrically conductive materials. · Do not pull on the cables. · Use cable ducts to lay cables through walls with sharp edges. · Refer to rooftop unit nameplate and NEC for proper power supply rating.
Maintenance
It is forbidden to operate the air conditioner without the filter screen, otherwise, the evaporator coil will be defiled and the service life of air conditioner will be affected.
Cleaning of Filter Screen
Position of left and right buckles of the decorative panel Regularly remove the filter screen behind the decorative panel inside the panel (press the left and right buckles of the decorative panel, and the decorative panel can be removed), flush it backwards with clear water, dry it and reinstall it.
Panel Surface Cleaning
Clean the outer surface of the panel with soft cloth dipped in neutral detergent. Do not use polishing or cleaning powder.
Fan Motor
The fan motor has been lubricated before leaving the factory and does not need special maintenance.
Position of left and right buckles of the decorative panel

Rev: 02.17.25

Filter screen Decorative panel

Head direction of the RV Display board

Page 4

CCD-0008084

Replaceable Parts List

G

E

C

J

I

H

D

F B
A

Callout A B C D
E
F G H I J
Rev: 02.17.25

Part # 2023009326 2023009327 2023009328 2023009310
N/A Locally Sourced
2023042153 2024000057 2024025829 2024025830 2024025838

Description Display Board (IR Receiver PCB) Filter PCB Remote Control + Remote Control Bracket Kit
Power Plug Pig Tail (J Series - Open End)
Push Latch 400 X 400 Opening Adapter Gasket Airflue Foam Rubber 1 Airflue Foam Rubber 2 Airflue Foam Rubber
Page 5

Model All All All All FACTRCSM-PS-A, FACR09SM-PS_KIT-A, FACR12SM-PS_KIT-A All All All All All
CCD-0008084

Troubleshooting

If the air conditioning equipment cannot work normally, please carry out inspection as follows to remove the faults:
A. Check whether the fuse of air conditioning equipment or leakage circuit breaker of the RV is turned on; If the air conditioner is powered by a generator, please first confirm whether the generator power matches the air conditioner, whether the generator runs normally and generates electricity, and whether voltage output of the generator is stable.
B. If the RV is connected to the mains supply, please make sure that the specification of power line matches the operating load of this product and that there is power supply. Check whether the mains voltage meets related requirements (the operating voltage of air conditioner is 220V); I. Check whether the connecting wires of air conditioner are inserted in place and connected in good condition. II. If the air conditioner still cannot work normally after the above inspection, please contact the factory for further help.

Trouble/ Symptom
Rooftop air conditioner constantly switches itself off

Cause Freeze sensor has tripped.

Solution
Outer temperature is too low or all air nozzles are closed.

The rooftop air conditioner is not set to cooling.

Set the rooftop air conditioner to cooling.

Not cooling well
Water enters the vehicle
Rooftop air conditioner does not switch on
Rev: 02.17.25

The set temperature is too high.

Select a lower temperature.

The evaporator fan is damaged.

The condenser fan is damaged.

The air intake grilles are blocked or obstructed.

The blower is defective.

The condensation water drainage openings are clogged up.

The seals are damaged.

No supply voltage connected.

The voltage is too low.

Fuse blown or circuit protector tripped.

Page 6

Contact an authorized service agent or Furrion (see the detail contact info at the back page of this manual). Contact an authorized service agent or Furrion (see the detail contact info at the back page of this manual). Remove any leaves and other dirt from the ventilation grilles of the rooftop air conditioner. Contact an authorized service agent or Furrion (see the detail contact info at the back page of this manual).
Clean the drainage openings for condensation water.
Contact an authorized service agent or Furrion (see the detail contact info at the back page of this manual). Check the power supply. Contact an authorized service agent or Furrion (see the detail contact info at the back page of this manual).
Check the electrical fuse of the power supply.
CCD-0008084

Error Code of Display Board

Code Cause

E1

Fault of indoor temperature sensor

E2

Fault of indoor coil temperature sensor

E3

Fault of outdoor coil temperature sensor

E4

Fault of outdoor ambient temperature sensor

Specifications

Solution
Check the sensor butt joint and replace the temperature sensing head.
Check the sensor butt joint and replace the temperature sensing head.
Check the sensor butt joint and replace the temperature sensing head.
Check the sensor butt joint and replace the temperature sensing head.

Rated cooling capacity Rated heating capacity Power supply
Compressor
Rated cooling power Rated heating power Air volume (high speed) Refrigerant (R 410 A) Cable standard Circuit protection

FACR09SM-PS

FACR12SM-PS

9000BTU

12000BTU

9500BTU

12500BTU

220-240 VAC/ 50Hz

Running current - 4.2A

Running current - 5.5A

Locked -rotor current - 22.5A

Locked -rotor current - 28A

1000W

1300W

800W

1060W

490m3/h

480m3/h

620g

740g

12AWG Copper wire with the length of no more than 8m

20A safety wire or fuse

Circuit Diagram of Outdoor Unit and Panel

Rev: 02.17.25

Page 7

CCD-0008084

Furrion, LLC (Furrion) are wholly owned subsidiaries of Lippert Components, Inc. (Lippert) Furrion, LLC (Furrion) sont des filiales en propriété exclusive de Lippert Components, Inc. (Lippert)
Furrion, LLC: 52567 Independence Ct., Elkhart, IN, 46514
Furrion Innovation Center & Institute of Technology Centre d'innovation et institut de technologie Furrion 22244 Innovation Drive, Elkhart, IN 46514-5514, USA Toll free/Numéro gratuit/Línea telefónica gratuita:1-800-789-3341 Email/Courriel/Correo electrónico: support@furrion.com
©2007-2025 Furrion, LLC. All rights reserved.
©2007-2025 Furrion, LLC. Tous droits réservés.
For Patent Info: www.Lippert.com/patents
Pour des informations sur les brevets: www.Lippert.com/patents
FURRION.COM
The contents of this manual are proprietary and copyright protected by Lippert. Lippert prohibits the copying or dissemination of portions of this manual unless prior written consent from an authorized Lippert representative has been
provided. Any unauthorized use shall void any applicable warranty. The information contained in this manual is subject to change without notice and at the sole discretion of Lippert. Revised editions are available for free download from lippert.com.
Please recycle all obsolete materials.
Les renseignements contenus dans le présent manuel peuvent seulement être distribués sous forme de document complet, à moins de recevoir l'approbation explicite de Lippert Components pour distribuer desparties individuelles. Tous les renseignements contenus dans le présent manuel peuvent être modifiés sans préavis. Les éditions révisées pourront être téléchargées gratuitement sur le site lci1.com. Ces
renseignements sont considérés comme étant factuels jusqu'à ce qu'une version révisée les rende désuets.
Veuillez recycler tout le matériel désuet.
For all concerns or questions, please contact Lippert. Communiquer avec Lippert Components si vous avez des questions ou des préoccupations. Ph: 432-LIPPERT (432-547-7378) | Web: lippert.com | Email: customerservice@lci1.com

