Bosch 96% AFUE Gas Furnace - BGH96 Model

Engineering Submittal Sheet

Overview and Certifications

The Bosch BGH96 is a 96% AFUE condensing gas furnace designed for residential applications. It is ENERGY STAR rated and features a reliable, proven two-stage design with multi-speed ECM motors for quiet and efficient operation.

Certifications:

  • AHRI Certified®
  • ENERGY STAR®
  • ETL Listed (Intertek 3124627)

Note: This product is not to be sold or installed in the State of California in the South Coast Air Quality Management District or San Joaquin Valley Air Basin territory.

Product Features

Standard Features

  • Up to 96% AFUE heating efficiency, ENERGY STAR rated.
  • 5-year parts limited warranty, 20-year heat exchanger limited warranty.
  • Reliable, proven two-stage design.
  • Compatibility with the Bosch Connected Control BCC100 Thermostat.
  • 3-way multipoise design allows for flexibility in multiple installation types.
  • Field convertible gas type for natural gas to propane gas conversion.
  • Multi-speed ECM motors for quiet and efficient operation.
  • Hot-surface ignition for dependable operation.
  • Durable aluminized steel tubular heat exchanger and stainless-steel (AL 29-4C alloy) secondary heat exchanger.
  • Pairs with Bosch IDS1.0/2.0 heat pump, reaching up to 19 SEER.
  • LED fault diagnostics for quick and easy service calls.

Cabinet Features

  • Low profile (33.75") cabinet fits in tight spaces.
  • Convenient left or right-hand connection for gas and electric service.
  • Anti-rust: Painted, galvanized, 21-gauge steel cabinet, passes a 500-hour salt spray test.
  • Low noise: Fully insulated (fiberglass insulation) design minimizes indoor noise.
  • 3-way multipoise design allows for flexibility in multiple installation types (Upflow: side or bottom return; Horizontal).

Warranty

All models installed in one or two-family residential dwellings come standard with a 5-year limited warranty on parts and a 20-year limited warranty on primary & secondary heat exchangers. Registration on bosch-climate.us upgrades the parts warranty to 10 years and heat exchanger warranty to lifetime. Applications other than one or two-family residential dwellings receive a 1-year parts warranty and a 10-year heat exchanger warranty.

For complete warranty details, please see: https://www.bosch-climate.us/support-center/product-warranty-library/gas-furnace-warranty.html

Key Components

Diagram showing the internal layout of the furnace with numbered components. Key components include: 1. Outlet Flue Vent, 2. Flame Sensor, 3. Chamber Limit Switch-fixed, 4. Condensate Overflow Switch, 5. Inducer, 6. Door Switch, 7. Integrated Control Module, 8. Blower, 9. Transformer, 10. Condensate Trap, 11. Junction Box, 12. Condensate Collector, 13. Low Fire Pressure Switch, 14. Two-Stage Gas Valve, 15. Hot Surface Ignitor, 16. Gas Manifold, 17. Air Inlet, 18. High Fire Pressure Switch, 19. Burner, 20. Rollout Limit Switch-resettable.

Component Identification
1. Outlet Flue Vent
2. Flame Sensor
3. Chamber Limit Switch-fixed
4. Condensate Overflow Switch
5. Inducer
6. Door Switch
7. Integrated Control Module
8. Blower
9. Transformer
10. Condensate Trap
11. Junction Box
12. Condensate Collector
13. Low Fire Pressure Switch
14. Two-Stage Gas Valve
15. Hot Surface Ignitor
16. Gas Manifold
17. Air Inlet
18. High Fire Pressure Switch
19. Burner
20. Rollout Limit Switch-resettable

Model Nomenclature

Diagram illustrating the Bosch BGH96 model nomenclature, breaking down the model number (e.g., BGH96 M 060 B 3 A) into its components: Gas Furnace, Bosch, Two-stage/x13 ECM Muti-speed, Upflow/Horizontal, 96% AFUE, 60 kBTU/hr, 17-1/2 inch Cabinet Width, 3 Tons Nominal Cooling Capacity, Serial Number.

Model Breakdown Example:

  • B: Bosch
  • GH: Gas Furnace
  • 96: AFUE (96%)
  • M: Orientation (Upflow/Horizontal)
  • 060: Capacity (60 kBTU/hr)
  • B: Cabinet Width (17-1/2 inch)
  • 3: Nominal Cooling Capacity (3 Tons)
  • A: Serial Number designation

* Nominal 350-400 CFM per 12,000 BTU/hr

Dimensions and Connections

Diagrams showing the front, left side, right side, top, and bottom views of the furnace, indicating connection points for combustion air, gas pipe, electrical, condensate drain, and thermostat wiring. The bottom view shows the panel removed. A table provides specific dimensions (Cabinet Width, Supply-Air Width, Return-Air Width) and Shipping Weight for each furnace model.

Furnace Model "A" Cabinet Width In. (mm) "D" Supply- Air Width In. (mm) "E" Return- Air Width In. (mm) Shipping Weight lbs (kgs)
BGH96M060B3A17.5 (445)16 (406)15-27/32 (402)162.5 (73.7)
BGH96M080B3A17.5 (445)16 (406)15-27/32 (402)168.5 (76.4)
BGH96M080C4A21 (533)19.5 (495)19-13/32 (493)184.6 (83.7)
BGH96M100C5A21 (533)19.5 (495)19-13/32 (493)194.6 (88.3)
BGH96M100D5A24.5 (622)23 (584)22-27/32 (580)205.1 (93.0)
BGH96M120D5A24.5 (622)23 (584)22-27/32 (580)209.5 (95.0)

Technical Specifications

Basic Product Information & Performance

Basic Product Information BGH96M060B3A BGH96M080B3A BGH96M080C4A BGH96M100C5A BGH96M100D5A BGH96M120D5A
Bosch Part Number773800649677380064977738006498773800649977380065007738006501
Fuel TypeNatural Gas/ Propane Gas*Natural Gas/ Propane Gas*Natural Gas/ Propane Gas*Natural Gas/ Propane Gas*Natural Gas/ Propane Gas*Natural Gas/ Propane Gas*
ENERGY STAR CertifiedYYYYYY
AFUE (%)969696969696
Input (High fire) (Btu/h)600008000080000100000100000120000
Input (Low fire) (Btu/h)390005200052000650006500078000
Output (High fire) (Btu/h)5700076000760009500095000115000
Output (Low fire) (Btu/h)370004900049000620006200075000
Air Temperature Rise (°F)30-6035-6535-6535-6535-6540-70
Design Max. Outlet Air Temperature (°F)160165165165165170
Static Pressure - Heating (in. WC)0.120.150.150.20.20.2
Static Pressure - Cooling (in. WC)0.50.50.50.50.50.5

Circulating Blower Data

Circulating Blower BGH96M060B3A BGH96M080B3A BGH96M080C4A BGH96M100C5A BGH96M100D5A BGH96M120D5A
Typex13 ECMx13 ECMx13 ECMx13 ECMx13 ECMx13 ECM
Diameter blower wheel (Inch)12 3/812 6/812 6/812 6/812 6/812 6/8
Height blower wheel (Inch)811 1/411 1/411 1/411 1/411 1/4
Tons AC @ 0.5" ESP1.5/2/2.5/31.5/2/2.5/32.5/3/3.5/43.5/4/4.5/53.5/4/4.5/53.5/4/4.5/5
Motor Horsepower3/411111
Air Flow (0.5 ESP in. WC) - High (CFM)128012711312203120952127
Air Flow (0.5 ESP in. WC) - Mid-High (CFM)110010711092183618891907
Air Flow (0.5 ESP in. WC) - Mid (CFM)910886894157316091620
Air Flow (0.5 ESP in. WC) - Mid-Low (CFM)690649625124112411265
Air Flow (0.5 ESP in. WC) - Low (CFM)500539455820802814
Motor Speeds (# speeds)5**5**5**5**5**5**
Motor Speeds (settings)High/Mid-High/Mid/Mid-Low/LowHigh/Mid-High/Mid/Mid-Low/LowHigh/Mid-High/Mid/Mid-Low/LowHigh/Mid-High/Mid/Mid-Low/LowHigh/Mid-High/Mid/Mid-Low/LowHigh/Mid-High/Mid/Mid-Low/Low
Motor Speeds (r/min)1050 (rated)1050 (rated)1050 (rated)1050 (rated)1050 (rated)1050 (rated)
Inducer Motor Power Input (High) (W)63±10%63±10%63±10%63±10%63±10%63±10%
Inducer Motor Power Input (Low) (W)37±10%37±10%37±10%42±10%42±10%42±10%
Power supply (V/Hz/PH)115V/60HZ/1PH115V/60HZ/1PH115V/60HZ/1PH115V/60HZ/1PH115V/60HZ/1PH115V/60HZ/1PH
Max Overcurrent Protection (MOP***) (Amps)151515202020
Blower motor full load (FLA) (Amps)887.811.510.510.5

Combustion System Specifications

Model BGH96M060B3A BGH96M080B3A BGH96M080C4A BGH96M100C5A BGH96M100D5A BGH96M120D5A
Max. Inlet Gas Press (in. WC) - Natural Gas10.510.510.510.510.510.5
Max. Inlet Gas Press (in. WC) - Propane Gas (LP)131313131313
Min. Inlet Gas Press (in. WC) - Natural Gas4.54.54.54.54.54.5
Min. Inlet Gas Press (in. WC) - Propane Gas (LP)111111111111
Natural Gas Manifold Pressure (High fire) (in. WC)3.53.53.53.53.53.5
Natural Gas Manifold Pressure (Low fire) (in. WC)1.61.61.61.61.61.6
Propane Gas Manifold Pressure (High fire) (in. WC)101010101010
Propane Gas Manifold Pressure (Low fire) (in. WC)444444
Natural Gas Factory Orifice (0-2000 feet) (#)454545454545
Propane Gas (LP) Factory Orifice (0-2000 feet)* (#)555555555555
Gas Connection Size (in. NPT)1/21/21/21/21/21/2
Ignition DeviceHot surfaceHot surfaceHot surfaceHot surfaceHot surfaceHot surface
Number of Burners (#)344556
Primary Heat Exchanger Diameter (Inch)1 6/81 6/81 6/81 6/81 6/81 6/8
Primary Heat Exchanger (# tubes)344556
Secondary Heat Exchanger Diameter (Inch)3/83/83/83/83/83/8
Secondary Heat Exchanger (# tubes)333339394848
Flue Vent Diameter (Inch)2"/3"2"/3"2"/3"2"/3"2"/3"3"

Dip Switches

Dip Switches BGH96M060B3A BGH96M080B3A BGH96M080C4A BGH96M100C5A BGH96M100D5A BGH96M120D5A
Heating Blower Control (Heating Off-Delay)Adjustable: 90, 120, 150, 180 seconds
Cooling Blower Control (Cool Off-Delay)Adjustable: 60, 90, 120, 150 seconds
Upstage W1 to W2 DelayAdjustable: OFF, 10 minutes, AUTO, 20 minutes

Cabinet Size & Shipping Data

Cabinet BGH96M060B3A BGH96M080B3A BGH96M080C4A BGH96M100C5A BGH96M100D5A BGH96M120D5A
Cabinet TypeBBCCDD
Cabinet Size Width (Inch)17.517.5212124.524.5
Cabinet Size (DxH) (Inch)(28-3/4)"x(33-3/4)"(28-3/4)"x(33-3/4)"(28-3/4)"x(33-3/4)"(28-3/4)"x(33-3/4)"(28-3/4)"x(33-3/4)"(28-3/4)"x(33-3/4)"
Packing Dimension (without pallet) (WxDxH) (Inch)(20)"x(31)"x(35-1/2)"(20)"x(31)"x(35-1/2)"(23-1/2)"x(31)"x(35-1/2)"(23-1/2)"x(31)"x(35-1/2)"(27)"x(31)"x(35-1/2)"(27)"x(31)"x(35-1/2)"
Packing Dimension (with pallet) (WxDxH) (Inch)(20)"x(31)"x(40)"(20)"x(31)"x(40)"(23-1/2)"x(31)"x(40)"(23.5)"x(31)"x(40)"(27)"x(31)"x(40)"(27)"x(31)"x(40)"
Net Weight (unit only) (lbs)135141152162169.6174
Gross Weight (shipping weight with pallet & packaging) (lbs)162.5168.5184.6194.6205.1209.5

* All Bosch 96% AFUE Gas Furnaces come standard with Natural Gas to LP Conversion Kits. These kits are only applicable for units installed at elevations between 0 and 2,000 feet.

For LP applications above 2000 ft elevation, the manifold and inlet gas pressure requirements remain the same as stated in this manual, the only change is to the orifices used. Refer Tables 14 & 15 in Section 9.2 of the Installation, Operation, and Maintenance Manual to determine which orifice to use based on your application.

AHRI 201/240 System Performance Data

General Operating Conditions:

  • Furnace designed for minimum continuous return-air temperature of 60°F (16°C) (DBT) or intermittent operation down to 55°F (13°C) (DBT).
  • Return-air temperature must not exceed 85°F (29°C) (DBT).
  • Not approved for installation in mobile homes, recreational vehicles, or outdoors.
  • Maximum shipment stacking: 3 units high (120").
  • Inlet gas supply pressures must be maintained within specified ranges for constant and reliable operation.

Inverter Ducted Split 2.0 + Cased Coil + 96% Furnace AHRI 201/240 System Performance Data

System Tonnage Outdoor Unit Model Indoor Unit Model Furnace Model Coils/Air Handlers Cooling Capacity (BTU/h) Heating Capacity CFM
Total EER² SEER¹ Hi (BTU/h) HSPF³ Low (BTU/h)
2 tonBOVA-36HDN1-M20GBMAC2430ANTDBGH96M060B3A240001318.5240001018000820/630
BOVA-36HDN1-M20GBMAC2430ANTDBGH96M080B3A240001318.5240001018000800/580
BOVA-36HDN1-M20GBMAC2430BNTDBGH96M060B3A2400013.519240001019000860/680
BOVA-36HDN1-M20GBMAC2430BNTDBGH96M080B3A2400013.519240001019000840/630
3 tonBOVA-36HDN1-M20GBMAC3036ANTDBGH96M060B3A3220011.2173400010250001050/800
BOVA-36HDN1-M20GBMAC3036ANTDBGH96M080B3A3220011.2173400010250001020/800
BOVA-36HDN1-M20GBMAC3036BNTDBGH96M060B3A3300011.617.53420010250001100/850
BOVA-36HDN1-M20GBMAC3036BNTDBGH96M080B3A3300011.617.53420010250001070/850
BOVA-36HDN1-M20GBMAC3036CNTDBGH96M080C4A3360012183420010250001050/820
BOVA-36HDN1-M20GBMAC3036CNTDBGH96M100C5A3360012183420010250001150/750
4 tonBOVA-60HDN1-M20GBMAC4248BNTFBGH96M080B3A3300012.518.53420010260001000/850
BOVA-60HDN1-M20GBMAC4248CNTFBGH96M100C5A3300012.518.53420010260001100/800
BOVA-60HDN1-M20GBMAC4248BNTFBGH96M080B3A4300011.218450009.5340001250/1050
BOVA-60HDN1-M20GBMAC4248CNTFBGH96M080C4A440001218.54600010350001250/1050
BOVA-60HDN1-M20GBMAC4248CNTFBGH96M100C5A4500012.518.54650010350001450/1150
BOVA-60HDN1-M20GBMAC4248DNTFBGH96M100D5A4550012.518.54700010350001500/1200
BOVA-60HDN1-M20GBMAC4248DNTFBGH96M120D5A4550012.518.54700010350001500/1200
5 tonBOVA-60HDN1-M20GBMAC4860CNTFBGH96M100C5A5200012185350010370001450/1150
BOVA-60HDN1-M20GBMAC4860DNTFBGH96M100D5A5200012.518.55400010380001500/1200
BOVA-60HDN1-M20GBMAC4860DNTFBGH96M120D5A5200012.518.55400010380001500/1200

¹ SEER: Seasonal Energy Efficiency Ratio; Certified per AHRI 210/240

² EER: Energy Efficiency Ratio; Certified per AHRI 210/240

³ HSPF: Heating Seasonal Performance Factor; Certified per AHRI 210/240

* Items in bold boxes meet the requirements for ENERGY STAR

Air Delivery

The duct system should be designed and sized according to accepted national standards such as those published by: Air Conditioning Contractors Association (ACCA), Sheet Metal and Air Conditioning Contractors National Association (SMACNA) or American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) or consult The Air Systems Design Guidelines reference tables available from your local distributor. The duct system should be sized to handle the required system design CFM at the design external static pressure. The furnace airflow rates are provided in the table below.

Tables showing Air Delivery (CFM) versus External Static Pressure (in. WC) for various furnace sizes (60B, 80B, 80C, 100C, 120D) at different speed settings (H, Mid-H, Mid, Mid-L, Low). These tables provide airflow performance without a filter. An additional 0.1 in. WC static pressure should be assumed if a 3/4 inch washable media filter is used.

Furnace Size Return-air inlet Speed CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F
60BBottom or SidesH143030.73713903042.7135031.145132032.149.4128033.658124035.558120037.658116040.458111042.758106545.158
Mid-H12453042.7120531.143.4116532.145113033.246.5110035.148.310503750.1101038.752.696040.455.192042.45886545.158
Mid107532.149.4103533.452.9100035.555.495537.65891039.358860415882043.15878045.15873048.25868551.358
Mid-L88539.141.783041.744.978044.94873546.551.26904854.565051.259.159054.559.155059.159.152059.159.147059.159.1
Low78048.352.870752.85864058--579500466403356320253------------------------------
80BBottom or SidesH141135.550.5137436.451.8133937.553.2130338.854.6127140.356123341.957.8119043.859.8114845.662110247.164.6105448.264.6
Mid-H12153856.6117839.258.4114440.460.2110841.762.3107143.264102944.966.398546.969.194548.971.589851.574.285454.274.2
Mid104440.843.4100243.445.896845.850.593146.550.988648.35484150.957.68055460.876757.664.471860.864.467764.464.4
Mid-L82550.553.779053.758.474355.462.969858.4--64960.8--60864.4--457----527----491----463----
Low78656.862.272062.2--64559.8--59853.9--53950.3--43638.5--34830.2----------------------
80CBottom or SidesH151635.146.7146736.247.414183848.8136739.850.1131241.652.5126143.354.8120145.257.4114447.759.9108650.962.710295462.7
Mid-H13163553.812593753.2120338.255.8114939.458.4109241.162103142.765.697645.269.690947.772.685550.975.47915475.4
Mid114240.360107643.161.1101445.46096047.761.589451.2--82354.6--76558.2--70261.8--651----597----
Mid-L9014949.982949.955.776755.761.569261.5--62556.2--56250.6--50646.3--40949.9--345----------
Low80057--67461.8--61849.8--49845.5--455400360300240----------------------------
100CBottom or SidesH141135.550.5137436.451.8133937.553.2130338.854.6127140.356123341.957.8119043.859.8114845.662110247.164.6105448.264.6
Mid-H12153856.6117839.258.4114440.460.2110841.762.3107143.264102944.966.398546.969.194548.971.589851.574.285454.274.2
Mid104440.843.4100243.445.896845.850.593146.550.988648.35484150.957.68055460.876757.664.471860.864.467764.464.4
Mid-L82550.553.779053.758.474355.462.969858.4--64960.8--60864.4--457----527----491----463----
Low78656.862.272062.2--64559.8--59853.9--53950.3--43638.5--34830.2----------------------
120DBottom or SidesH151635.146.7146736.247.414183848.8136739.850.1131241.652.5126143.354.8120145.257.4114447.759.9108650.962.710295462.7
Mid-H13163553.812593753.2120338.255.8114939.458.4109241.162103142.765.697645.269.690947.772.685550.975.47915475.4
Mid114240.360107643.161.1101445.46096047.761.589451.2--82354.6--76558.2--70261.8--651----597----
Mid-L9014949.982949.955.776755.761.569261.5--62556.2--56250.6--50646.3--40949.9--345----------
Low80057--67461.8--61849.8--49845.5--455400360300240----------------------------

Air Delivery - CFM (Without Filter)

Furnace Size Return-air inlet Speed CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F CFM Temp Rise-1st stage °F Temp Rise-2nd stage °F
100CBottom or SidesH2195--40.32158--41.02116--41.82072--42.72031--43.61985--44.61940--45.61896--46.71852--47.81862--47.5
Mid-H2008--44.11963--45.11924--46.01882--47.01836--48.21791--49.41744--50.81697--52.21648--53.71603--55.2
Mid1753--35.41709--36.61666--37.61627--38.71573--39.91530--41.31487--42.71444--44.41395--45.61347--47.0
Mid-L1447--39.81388--41.51338--43.01286--44.71241--46.41186--48.51137--50.61083--53.21029--55.9983--58.5
Low1089--52.81021--56.4946--60.8883----820----751----685----625----565----520----
100DBottom or SidesH2283--38.82239--39.52193--40.42143--41.32095--42.32049--43.21998--44.31947--45.51897--46.71847--48.0
Mid-H2086--42.42038--43.51988--44.51942--45.61889--46.91841--48.11792--49.41745--50.71695--52.31637--54.1
Mid1813--48.81760--50.31711--51.81657--53.41609--55.01560--56.81506--58.81453--60.91402--63.11350--64.6
Mid-L1487--38.71417--40.61360--42.31296--44.41241--46.41183--48.71123--51.31064--54.11005--57.2941--61.1
Low1122--55.61036--58.9977--64.7889----802----731----646----586----532----485----
120DBottom or SidesH2290--46.42253--47.22213--48.02170--49.02127--50.02080--51.12031--52.31985--53.51937--54.91888--56.3
Mid-H2079--40.02037--41.21993--40.01950--41.21907--42.41856--43.51813--44.51767--45.61726--46.71675--47.8
Mid1809--51.11764--52.21719--53.31668--54.51620--55.71572--57.31528--58.61487--60.11432--61.61364--63.4
Mid-L1489--46.41429--48.31373--50.31311--52.71265--54.61208--57.21137--60.71083--63.81032--66.9972----
Low1123--61.51051--65.71352--899----814----741----688----605----551----507----

* A filter is required for each return air inlet. This table shows the airflow performance without a filter. To determine airflow performance with a filter, if a 3/4 inch (19 mm) washable media filter is used, assume an additional 0.1 in. WC available external static pressure.

** The manufacturer default fan settings are based on model

-- Indicates unstable operating conditions.

Filters

Bosch does not supply filters or filter racks with furnace units. All filters must be field supplied according to the Manufacturer recommended high velocity filter sizes and specifications shown below.

Furnace cabinet width Filter size - Side return Filter size - Bottom return Filter type
17-1/216X2516X25High Velocity (600 FPM)
2116X2520X25High Velocity (600 FPM)
24.516X2524X25High Velocity (600 FPM)

High Altitude Derating

In high altitude applications, a standard derate for altitude from National Fuel Gas Code ANSI Z223.1 of 4% per 1000 feet above sea level must be taken. Refer to the most recent version of ANSI Z223.1 for correct gas orifice based on your specific application. The furnace derate is 4% for each 1,000 feet above sea level. For Canada applications, regulation requires 10% derating between 2000-4500 ft. When an appliance is installed at elevations above 4500 ft, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1000 ft.

The table below is based upon a heating value of approximately 1,000 Btu/ft³. In some areas the gas supplier may artificially derate the gas in an effort to compensate for the effects of altitude. If the gas is artificially derated, the appropriate orifice size must be determined based upon the BTU/ft³ content of the derated gas and the altitude. Refer to the latest version of NFPA54/ANSI Z223.1 and information provided by the gas supplier to determine the proper orifice size.

High Altitude Derate Orifice Size Chart (Natural and LP Gas*)

Input Rate KBTU/H Number of burners Elevation (Ft) 0-2000 Elevation (Ft) 2000-4000 Elevation (Ft) 4000-6000 Elevation (Ft) 6000-8000 Elevation (Ft) 8000-10000
NG** LP NG** LP NG** LP NG** LP NG** LP
60345554756485749585059
80445554756485749585059
100545554756485749585059
120645554756485749585059

* LP orifice based on 10 in. WC manifold pressure

** NG denotes natural gas

? The input to the furnace must be checked AFTER reorificing.

? For Canada applications, regulation requires 10% derating between 2000-4500 ft. When an appliance is installed at elevations above 4500 ft, the certified high altitude input rating shall be reduced at the rate of 4% for each additional 1000 ft.

? Units installed with natural gas at altitudes up to 2000 ft. above sea level may be installed without any modifications. Units installed above 2000 ft. of elevation must use orifices as specified in the above table.

Venting

This Category IV, dual certified (AHRI and ETL) direct vent furnace is designed for residential applications. It may be installed without modification to the condensate system in a basement, garage, equipment room, alcove, attic or any other indoor location where all required clearance to combustibles and other restrictions are met*. The combustion air and the venting system must be installed in accordance with Section 5.3, Air for Combustion and Ventilation, of the National Fuel Gas Code Z223.1/NFPA 54 (latest edition), or Sections 7.2, 7.3 or 7.4 of CSA B149.1, National Gas and Propane Codes (latest edition) or applicable provisions of the local building code and these instructions.

This furnace requires a special venting system. This furnace is for use with schedule-40 PVC, PVC-DWV, CPVC, or ABS-DWV pipe, and must not be vented in common with other gas-fired appliances. Construction through which vent/air intake pipes may be installed is maximum 24 inches (610 mm), minimum 3/4 inches (19mm) thickness (including roofing materials). Refer to Section 8 "Vent System" of the Installation, Operation, and Maintenance Manual, for installation instructions related to venting.

* The condensate from this unit is acidic; adhere to all local and national codes when draining condensate. If proper procedures are not followed, this may lead to property damage.

Diagrams illustrating three common venting and combustion air intake configurations: 1. Gable Vent with Soffit Vent and Ventilated Attic, 2. Gable Vent with Soffit Vent and Ventilated Crawl Space, 3. Gable Vent with Soffit Vent and Ventilated Attic (alternative setup).

Equivalent Pipe Length

The equivalent length of the vent system is the total length of straight pipe PLUS the equivalent length of all of the elbows.

Maximum Equivalent Pipe Length

Model Input kBTU/H (kW) Pipe Size - Inches (cm) Maximum Equivalent Length - Feet (m)
60 (17.6)2 (5.1)60 (18.2)
60 (17.6)3 (7.6)90 (27.4)
80 (23.4)2 (5.1)60 (18.2)
80 (23.4)3 (7.6)90 (27.4)
100 (29.3)2 (5.1)30 (9.1)
100 (29.3)3 (7.6)90 (27.4)
120 (35.1)2 (5.1)N/A
120 (35.1)3 (7.6)90 (27.4)

Rules for Pipe Length:

  • Long radius (sweep) elbows are recommended. Standard elbows reduce total allowable pipe length. Short radius elbows are not allowed.
  • Maximum equivalent length applies separately to vent piping and air intake piping.
  • Three vent terminal elbows (two for vent, one for combustion air intake) are accounted for and need not be included in calculations.
  • All pipes and fittings must conform to ANSI and ASTM standards (e.g., Schedule 40 PVC, CPVC, ABS-DWV). Use appropriate cement and primer. Metallic materials are not permitted for venting or air intake.
  • Flexible connectors must be acid-resistant and rated for at least 225°F.
  • Models have 2" vent connections. For 3" pipe, transition must be as close to the furnace as possible.
  • Canadian vents must be certified to ULC S636.
  • First three feet (900 mm) of vent in Canada must be accessible for inspection.
  • Minimum vent length for all models is 5 feet.

Example Calculation: An 80,000 BTUH furnace requires 32 ft of pipe and four 90° elbows. Using 2" pipe and standard elbows results in 72 equivalent feet, exceeding the 60 ft limit. Using 2" pipe and sweep elbows results in 52 equivalent feet, which is acceptable. Using 3" pipe and standard elbows results in 72 equivalent feet, which is acceptable.

Required Clearance to Combustibles

Diagram showing the required clearances from combustible construction for the furnace. Clearances are indicated for the Front (3 inches), Top/Plenum (1 inch), Back (0 inches), and Sides (0 inches). An asterisk (*) indicates specific considerations for horizontal installation and service access.

Clearance SIDES* FRONT BACK TOP (PLENUM)
Minimum clearance (inches)0"3"0"1"

* When the unit is installed in the horizontal orientation, there must be 7" clearance for the externally mounted drain trap.

Ø 24 inches is required for service and maintenance.

Horizontal installation in attic or crawl space: Indicates supply or return sides when furnace is in the horizontal position. Line contact is permissible between lines formed by intersections of the side and back of the furnace cabinet and building joists, studs, or frame. Horizontal applications require a solid, supportive structure for installation.

Unit Wiring Diagram

Schematic wiring diagram illustrating the connections for heating and cooling applications with a 2-stage thermostat. It shows connections from the thermostat to the furnace's integrated control module, including terminals for blower, gas valve, pressure switches, limit switches, ignitor, and optional components like electronic air cleaners and humidifiers. It also details power supply connections and diagnostic LED indicators.

WARNING: High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

Diagnostic LED Codes:

LEDCodeDescription
RED1 FlashFlame sensed with gas valve off
2 FlashPressure switch closed with inducer off
3 Flash1st-stage pressure switch open with inducer on
4 FlashLimit/Rollout switch open
5 FlashLimit/Rollout switch open more than 15 minutes
6 FlashPressure switch cycle lockout
7 FlashLockout due to failed ignition
8 FlashLockout due to too many flame dropouts
9 FlashIncorrect line voltage polarity
10 FlashGas valve fault code
11 FlashLimit/Rollout switch open from 5 to 15 minutes
13 Flash2nd stage pressure switch open with high inducer on
SolidControl failure
AMBER1 FlashCall for heat active
4 FlashY thermostat demand without a G
RapidLow flame current
GREEN1 FlashStandby mode
RapidControl in Factory Test mode

Electrical & Controls

Ratings & Physical / Electrical Data

Input Output Nominal Airflow MAX. Unit AFUE Air Temp. Rise Max. Over-Current Protection Min. Wire Size (AWG) Max. Outlet Air Temp
MBHkWMBHkWCFM°F°CAmps@ 75 ft°F°C
60B317.65716.7120089630-6017-33151416071
80B323.47622.3120089635-6519-36151416574
80C423.47622.316007.89635-6519-36151416574
100C529.39527.8200011.59635-6519-36201416574
100D529.39527.8200010.59635-6519-36201416574
120D535.211531.2200010.59540-7022-39201417077

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.

National Electrical Code (NFPA-70-latest edition) and all local codes apply.

The furnace shall be installed so that the electrical components are protected from water.

Sequence of Operations - Heating Mode

  1. A call for first stage heat closes W1 contacts. Inducer blower energizes at high speed.
  2. Control waits for low pressure switch contacts to close. Optional humidifier energizes.
  3. Once low pressure switch contacts close, a 15-second pre-purge initiates.
  4. Inducer changes to low speed; 120V ignitor powers on.
  5. After ignitor warm-up, first stage manifold gas valve energizes (low fire). Flame must be detected within 4 seconds.
  6. If flame is detected, a 45-second HEAT delay-to-fan-on period begins.
  7. After delay, circulator fan energizes at low heat speed. Optional electronic air cleaner energizes.
  8. For a two-stage thermostat, a call for second stage heat (W1 & W2) energizes inducer at high speed and circulator at high heat speed. Second stage pressure switch contacts close, energizing the second stage gas valve (high fire).
  9. For a single-stage thermostat, a call for heat (W1) activates a heat staging timer (10, 20 min, or auto). After delay, second stage heat energizes as above.
  10. When second stage is satisfied, inducer motor reduces to low speed, second stage gas valve de-energizes. Circulator remains at high heat speed for 30 seconds, then reduces to low speed.
  11. When first stage is satisfied, first stage gas valve de-energizes, initiating HEAT delay-to-fan-off.
  12. Inducer postpurges for 15 seconds, then inducer and humidifier turn off.
  13. Upon completion of HEAT delay-to-fan-off, circulator turns off. Electronic air cleaner de-energizes.

Ignition Failure & Retries: If flame is not detected during trial-for-ignition or is lost before 10 seconds of establishment, the gas valve de-energizes, ignitor turns off, and the control enters a "retry" sequence (60-second wait with inducer interpurge). Two retries are allowed before system lockout. Flame established for >10 seconds clears the retry counter. Loss of flame after 10 seconds restarts the ignition sequence. Momentary loss of gas supply, flame blowout, or shorted/open flame probe circuit is sensed within 2 seconds; gas valve de-energizes, ignitor turns off, ignition sequence restarts. Recycles occur if gas supply returns or fault is corrected before the last attempt; otherwise, system lockout occurs. Lockout can be reset by momentary power interruption (10 seconds or longer).

Timing Specifications & Optional Switch Positions

(All times are in seconds, unless noted otherwise)

Event Definition 50M58-400 Optional Switch Positions - W2 Delay Nominal (Minutes)
SW1-1 SW1-2
Pre-purge TimeThe period of time intended to allow for the dissipation of any unburned gas or residual products of combustion at the beginning of a furnace operating cycle prior to initiating ignition.15OFFOFFOFF*
Ignitor Warm-up TimeThe length of time allowed for the ignitor to heat up prior to the ignition of gas flow.17OFFON10
ONOFFAUTO
ONON20
Trial for ignition Period (TFI)The period of time between initiation of gas flow and the action to shut off the gas flow in the event of failure to establish proof of the supervised ignition source or the supervised main burner flame.4* The factory default settings
Ignition Activation Period (IAP)The period of time between energizing the main gas valve and deactivation of the ignition means prior to the end of TFI.3
RetriesThe additional attempts within the same thermostat cycle for ignition when the supervised main burner flame is not proven within the first trial for ignition period.2 times
Valve Sequence periodValue sequence period equals 4 seconds trial for ignition period x (1 initial try + 2 retries)+12 seconds.12
Inter-purgeThe period of time intended to allow for the dissipation of any unburned gas or residual products of combustion between the failed trial for ignition and the retry period.60
Post-purge TimeThe period of time intended to allow for the dissipation of any unburned gas or residual products of combustion at the end of a furnace burner operating cycle, Post-purge begins at the loss of flame sense.15
Lock-Out TimeANSI standard rated module timing.300
Heat Delay-To-Fan-OnThe period of time between proof of the supervised main burner flame and the activation of the blower motor at heat speed.30
Heat Delay-To-Fan-Off*The period of time between the loss of a call for heat and the deactivation of the blower motor at Heat speed.*90/120/ 150/180
Cool Delay-To-Fan-OnThe period of time after a thermostat demand for cool before energizing the circulator blower motor at cool speed.1
Cool Delay-To-Fan-OffThe period of time between the loss of a call for cool and the deactivation of the blower motor at cool speed.60/*90/ 120/150
Automatic Reset TimeAfter one (1) hour of internal or external lockout, the control will automatically reset itself and go into an auto restart purge for 60 seconds.60 minutes

* These times will vary depending on option switch position.

When using a single stage thermostat, second stage delay is based on the setting of switch S1-1 & S1-2 dip switches.

Optional Switch Positions - Heat Off Delay

DIP Switch (SW)SW1-3SW1-4Nominal (Seconds)
OFFOFF90
ONOFF120
OFFON150
ONON180*
* The factory default settings

Optional Switch Positions - Cool Off Delay

DIP Switch (SW)SW3-1SW3-2Nominal (Seconds)
OFFOFF60
ONOFF90*
OFFON120
ONON150
* The factory default settings

PDF preview unavailable. Download the PDF instead.

Bosch Thermotechnology 7738006497 Specification Sheet Acrobat Distiller 20.0 (Windows)

Related Documents

Preview Bosch 96% AFUE Gas Furnace BGH96 Model Installation, Operation, and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining the Bosch 96% AFUE Gas Furnace, BGH96 Model. Covers safety, installation procedures, operational checks, troubleshooting, and maintenance.
Preview Bosch BGH96 96% AFUE Gas Furnace: Engineering Submittal Sheet
Comprehensive engineering submittal sheet for the Bosch BGH96 series 96% AFUE gas furnace. Details features, specifications, dimensions, performance data, installation clearances, venting requirements, and electrical controls for residential applications.
Preview Bosch BGH96 Condensing Gas Furnace Control Board Replacement Procedure
Technical service bulletin detailing the procedure for replacing the control board on Bosch BGH96 96% Condensing Gas Furnaces. Includes warnings, component lists, step-by-step instructions, wiring diagrams, and dip switch settings for qualified technicians.
Preview Bosch 96% AFUE Gas Furnace BGH96 Model Troubleshooting Guide
A comprehensive troubleshooting guide for the Bosch 96% AFUE Gas Furnace BGH96 Model, a 3-Way Multipoise Condensing Gas Furnace. This guide covers error codes, normal operation codes, safety instructions, and detailed troubleshooting steps for various operational issues.
Preview Bosch Buderus SSB Series Condensing Boilers: Engineering Submittal Sheet
This engineering submittal sheet provides detailed specifications, performance data, dimensions, and connection information for the Bosch Buderus SSB800, SSB1000, and SSB1000TL Gen 2 stainless steel condensing boilers, designed for commercial and light industrial applications.
Preview Bosch Buderus SSB1000TL/TL2/TL3/TL4 - Gen 2 Stainless Steel Condensing Boiler Engineering Submittal Sheet
Technical specifications and data for the Bosch Buderus SSB1000TL series of Gen 2 Stainless Steel Condensing Boilers. This document details engineering specifications, general data, performance metrics, operational parameters, dimensions, connection details, and clearance requirements for models SSB1000TL, SSB1000TL2, SSB1000TL3, and SSB1000TL4, suitable for residential, commercial, and light industrial applications.
Preview Bosch CL Model Series Commercial Water Source Heat Pumps Engineering Submittal Sheet
Comprehensive engineering submittal sheet detailing the Bosch CL Model Series of Commercial Water Source Heat Pumps, including technical specifications, performance data, dimensions, and operating limits.
Preview Bosch Greenstar ZWB 28-3 Boiler - ENERGY STAR Certified Specifications
Detailed specifications for the Bosch Greenstar ZWB 28-3 boiler, an ENERGY STAR certified model. This document outlines key features including its unique ID, fuel type, efficiency (AFUE), market availability, and certification status.