Robustel R3000 Hardware Manual
Version: 1.0.0 | Date: Aug. 15, 2022
Product Overview
The Robustel Industrial Dual SIM Cellular VPN Router (R3000) is a rugged cellular router offering state-of-the-art mobile connectivity for machine to machine (M2M) applications.
The front panel of the Robustel R3000 router is depicted, showing various ports and status LEDs. Labeled ports include: AUX, RUN, PPP, NET, USR, SIM, GPS, WLAN, In1, In2, OUT1, OUT2, GND, ETH0, ETH1, USB, and ORST. The Robustel logo is also visible.
Regulatory and Type Approval Information
Table 1: Directives
Directive | Description |
2011/65/EU | The European RoHS2.0 2011/65/EU Directive restricts hazardous substances in electrical and electronic equipment. It was issued by the European parliament and council on July 1, 2011. The RoHS2.0 Amendment Directive (EU) was published on June 4, 2015. Phthalates (DEHP, BBP, DBP, DIBP) were added to the restricted list in 2015/863. From July 22, 2019, European export restrictions apply to electronic and electrical products, including medical and monitoring equipment from July 22, 2021. [RoHS Compliant] |
2012/19/EU | The European WEEE 2012/19/EU Directive on waste electrical and electronic equipment was issued by the European parliament and council on July 24, 2012. |
2013/56/EU | The European 2013/56/EU Directive is a battery directive published on December 10, 2013. The button battery used in this product conforms to this standard. [Battery Directive Symbol] |
Table 2: Toxic or Hazardous Substances or Elements with Defined Concentration Limits
Name of the Part | Hazardous Substances | |||||||||
(Pb) | (Hg) | (Cd) | (Cr(VI)) | (PBB) | (PBDE) | (DEHP) | (BBP) | (DBP) | (DIBP) | |
Metal parts | 0 | 0 | 0 | 0 | - | - | - | - | - | - |
Circuit modules | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Cables and cable assemblies | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Plastic and polymeric parts | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Key:
0: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in RoHS2.0.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part might exceed the limit requirement in RoHS2.0.
-: Indicates that it does not contain the toxic or hazardous substance.
Radio Specifications
Category | Specification | Regions |
RF technologies | 2G, 3G, 4G, Wi-Fi*, GNSS* | |
Cellular Frequency* | 4G: LTE FDD: B1/B2/B3/B4/B5/B7/B8/B28 LTE TDD: B40 | Oceania |
3G: WCDMA: B1/B2/B5/B8 2G: GSM: B2/B3/B5/B8 | South America | |
4G: LTE FDD: B1/B3/B5/B7/B8/B20 LTE TDD: B38/B40/B41 3G: WCDMA: B1/B5/B8 2G: GSM: B3/B8 | EMEA | |
4G: LTE FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28 LTE TDD: B38/B39/B40/B41 3G: WCDMA: B1/B2/B4/B5/B6/B8/B19 2G: GSM: B2/B3/B5/B8 | North America | |
4G: LTE FDD: B1/B3/B8/B18/B19/B26 LTE TDD: B41 3G: WCDMA: B1/B6/B8/B19 | Japan | |
Wi-Fi Frequency | 2.4 GHz: 2.412 ~ 2.484 GHz 5 GHz: 4.910 ~ 5.825 GHz | |
Max RF power | 35 dBm@GSM, 25 dBm@WCDMA, 25 dBm@LTE, 18dBm@Wi-Fi |
* May vary on difference models.
Simplified EU Declaration of Conformity
Guangzhou Robustel Co., Ltd., located at 501, Building #2, 63 Yongan Road, Huangpu District, Guangzhou, China, declares that this radio equipment complies with all applicable EU directives. The full text of the EU DoC is available at: www.robustel.com/certifications/
FCC Declaration of Conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
IC Declaration of Conformity
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.
French Translation: L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) L' appareil ne doit pas produire de brouillage; (2) L' appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d' en compromettre le fonctionnement.
Radio Frequency Exposure Statement for IC
This device complies with IC exposure limits set forth for an uncontrolled environment. This device shall be installed and operated with minimum distance 20cm between the radiator & body.
French Translation: Cet équipement est conforme aux limites d'exposition IC définies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et la carrosserie.
Related Download Link
Find more product documents or tools at: www.robustel.com/en/documentations/
Technical Support
Tel: +86-20-82321505
Email: support@robustel.com
Web: www.robustel.com
Document History
Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.
Date | Firmware Version | Document Version | Change Description |
Aug. 15, 2022 | 5.0.0 | 1.0.0 | Initial release. |
Package Checklist
Before commencing installation, ensure your package has the following components:
- Device
- 3PIN Terminal Block
- 7PIN Terminal Block
- RCMS Card
- Quick Start Guide Card
- Cellular Antenna (Optional)
- Wi-Fi Antenna (Optional)
- Mounting Kit (Optional)
- Power Supply (Optional)
- Ethernet Cable (Optional)
Note: The accessories could be different on specific order.
Panel Layout
Panel Layout (May Vary on Different Models)
Front View: The front view of the R3000 router shows the SIM/Micro SD Card Slot, Serial Port, Power Supply connector, Grounding Screw, Reset Button, USB port, Ethernet Port, and Serial Port I/O.
Top View: The top view of the R3000 router displays the Cellular Antenna connector, LED Indicator panel, WLAN Antenna connector, and GPS Antenna connector.
Interface Descriptions
1. PIN Assignment
Note: RS-232/RS-485 depends on the equipment hardware selection, please set according to the actual situation of the equipment.
RS-232 Interface
PIN | Debug | RS-232 | Direction |
1 | CR | -- | R3000 → Device |
2 | CT | -- | R3000 → Device |
3 | GND | GND | -- |
4 | TXD | -- | R3000 → Device |
5 | RXD | -- | R3000 → Device |
6 | RTS | -- | R3000 → Device |
7 | CTS | -- | R3000 → Device |
Note: When the device is configured as 2*RS-485, the pin is defined as follows:
RS-485 Interface
PIN | Debug | RS-485 | Direction |
4 | Data+(A) | -- | R3000 → Device |
5 | Data-(B) | -- | R3000 → Device |
Power Interface
PIN | Power |
8 | Positive |
9 | Negative |
10 | GND |
DI/DO Interface (RS-485)
PIN | DI/DO | RS-485 | Direction |
11 | Input 1 | -- | R3000 → Device |
12 | Input 2 | -- | R3000 → Device |
13 | Output 1 | -- | R3000 → Device |
14 | Output 2 | -- | R3000 → Device |
15 | GND | -- | -- |
16 | Data+(A) | -- | R3000 → Device |
17 | Data-(B) | -- | R3000 → Device |
DI/DO Interface (RS-232)
PIN | DI/DO | RS-232 | Direction |
11 | Input 1 | -- | R3000 → Device |
12 | Input 2 | -- | R3000 → Device |
13 | Output 1 | -- | R3000 → Device |
14 | Output 2 | -- | R3000 → Device |
15 | IO_GND | -- | -- |
16 | TXD | -- | R3000 → Device |
17 | RXD | -- | R3000 → Device |
3 | GND | -- | -- |
Note: When PIN16/PIN17 is configured as RS-232, the GND of RS-232 should be connected to PIN3.
Typical Application
Diagrams illustrating typical applications:
- DI Connection: Shows IN1 connected to a circuit.
- DO connect to PNP transistor: Shows OUT1 connected to a PNP transistor.
- DO connect to NPN transistor: Shows OUT1 connected to an NPN transistor.
LED Indicators
Name | Color | Status | Description |
RUN | Green | On, fast blinking (250ms blink time) | Router is powered on (System is initializing) |
RUN | Green | On, blinking (500ms blink time) | Router starts operating |
RUN | Off | Router is powered off | |
PPP | Green | On, solid | Link connection is working |
PPP | Off | Link connection is not working | |
USR-OpenVPN | Green | On, solid | OpenVPN connection is established |
USR-OpenVPN | Off | OpenVPN connection is not established | |
USR-IPsec | Green | On, solid | IPsec connection is established |
USR-IPsec | Off | IPsec connection is not established | |
USR-Wi-Fi | Green | On, solid | Wi-Fi is enabled and working properly |
USR-Wi-Fi | Off | Wi-Fi is disabled or not working properly | |
NET | Green | On, solid | High Signal strength (21-31) is available |
NET | Yellow | On, solid | Medium Signal strength (11-20) is available |
NET | Red | On, solid | Low Signal strength (1-10) is available |
NET | Off | No signal | |
NET | Green | On, solid | Connection to 4G network is established |
NET | Yellow | On, solid | Connection to 3G network is established |
NET | Red | On, solid | Connection to 2G network is established |
NET | Off | Connection to network is not established or establishing | |
SIM | Green | On, solid | Main card is being used |
SIM | Green | On, blinking | Backup card is being used |
SIM | Off | NO SIM card |
Note: You can choose the display type of USR LED. For more details, please refer to RT123_SM_RobustOS Software Manual Service > Advanced > System >System Settings > User LED Type.
Reset Button
Function | Operation |
Reboot | Press and hold the RST button for 2~ 5 seconds under the operating status. |
Restore to default configuration | Press and hold the RST button for 5~10 seconds, the RUN LED starts blinking quickly, the router will restore to default configuration. |
Restore to factory default settings | Once the operation of restoring default configuration is performed twice within one minute, the router will restore to factory default settings. |
Note: For more details, please refer to RT123_SM_RobustOS Software Manual, 2.3 Factory Reset.
Ethernet Ports
There are 2 Ethernet ports on R3000 Router, including ETH0 and ETH1. Each Ethernet port has 2 LED indicators. The yellow one is a link indicator, while the green one is a speed indicator. For details about status, see the table below.
Indicator | Status | Description |
Link indicator | On, solid | Connection is established |
On, blinking | Data is being transferred | |
Off | Connection is not established | |
Speed indicator | On, solid | 100 Mbps mode |
Off | 10 Mbps mode |
USB Interface
Function | Operation |
Firmware upgrade | USB interface is used for batch firmware upgrading, but cannot be used for sending or receiving data from slave devices which connected to it. You can insert a USB storage device into the router's USB interface, such as a U disk or a hard disk. If there have a supported configuration file or a router firmware in this USB storage device, the router will automatically update the configuration file or the firmware. For more details, see RT123_SM_RobustOS Software Manual. |
Hardware Installation
- SIM Card Installation: Loosen the screws associated with the cover by using a screwdriver and then find the SIM card slot/Micro SD card slot. Press the card with finger until you hear a click and then tighten the screws associated with the cover by using a screwdriver. Put back the cover and tighten the screws associated with the cover by using a screwdriver. Torque specification: 1.0 ± 0.2 N.M. [SIM Card Slot Diagram]
- Antenna Installation: Rotate the antenna into the antenna connector accordingly. [Antenna Diagram]
- Terminal Block Installation: Insert the terminal blocks into the interfaces connector, then can connect the devices or sensors to the gateway via corresponding interfaces e.g. RS232/RS485, DIDO... [Terminal Block Diagram]
- Mounting Kit installation (Optional): Options include Wall mounting and DIN rail mounting. Torque specification: M3, 1.0 ± 0.2 N.M. [Wall Mounting Diagram], [DIN Rail Mounting Diagram]
Grounding the Device
Grounding will help to prevent the noise effect due to electromagnetic interference (EMI). Connect the device to the site ground wire by the grounding screw before powering on. [Grounding Diagram]
Power Supply Installation
Following the color of the head, connect the cable marked red to the positive pole through a terminal block, and connect the yellow one to the negative in the same way. The last step is to plug the power adapter into your socket. Note: The range of power voltage is 9 to 60V DC. [Power Cable Connection Diagram]
Login to the Device
- Connect the router's Ethernet port to a PC with a standard Ethernet cable.
- Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure "Use the following IP address". [IP Configuration Screenshot]
- To enter the gateway's web interface, type http://192.168.0.1 into the URL field of your Internet browser.
- Use login information shown in the product label when prompted for authentication.
- After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the device. [Web Interface Screenshot]
- The automatic APN selection is ON by default. If you need to specify your own APN, please go to the menu Interface->Link Manager->Link Setting->WWAN Settings to finish the specific setting.
- For more configuration details, please refer to RT123_SM_RobustOS Software Manual. (END)
Support: support@robustel.com
Website: www.robustel.com
©2022 Guangzhou Robustel Co., Ltd. All rights reserved. Subject to change without notice.