The Prestige APS596Z system is comprised of a central control module and various input/output harnesses and components. The diagram illustrates the connections for:
- 6-Pin Power Harness: Connects to Parking Light Output, Ground Input, Parking Light Input, Ignition Input, Siren Output, and Battery 12V Input.
- Valet/LED Harness: Connects to Data RX, DBI, Ground, Battery 12V, LED Output, and Valet Switch Input.
- Starter Kill Relay: Connects to Starter Kill, Ignition Input, Ground While Armed, Starter Output (Motor Side), and Starter Input (Key Side).
- 18-Pin Input/Output Harness: Connects to various inputs and outputs including Data RX, Data TX, Ground, Battery 12V, Trunk Shunt Input, Disarm Inputs, Arm Inputs, Dome Light Output, AUX Outputs, Horn Output, LED Output, and Door Trigger Input.
- RF Harness: Connects to Data RX, Data TX, Ground, and Battery 12V.
- CarLink Harness: Connects to Data TX, Data RX, Ground, and Battery 12V.
- Shock Sensor: Connects to Battery 12V, Ground, Warn Away, Full Trigger, and Trunk Shunt Input.
- Weblink Harness: Connects to Data RX, Data TX, Ground, and Battery 12V.
Note: Some harnesses like RF, CarLink, and Weblink may not be included and require separate purchase or specific vehicle integration modules like FlashLogic.
Quick Installation Guide
For complete installation guides and technical support, visit www.voxxuniversity.com or call 1-800-225-6074.
Notifications
The system provides feedback upon alarm trigger. Upon disarm, it beeps 4x and flashes the LED to indicate the trigger zone (Shock, Trunk/Hood, or Door).
Factory Keyless Upgrade
The APS596Z can function as a Factory Keyless Alarm Upgrade. Arm/Disarm inputs connect to the vehicle's door lock motors. Polarity detection is automatic or can be manually configured. The Trunk Shunt input is used for vehicles with factory power trunk/hatch release and also supports automatic or manual polarity configuration.
Remote Programming
The system includes two programmed remotes. Additional remotes can be programmed via Feature Bank 1. To enter auto-programming:
- Turn ignition key to ON.
- Press and release the valet button three times. System beeps and flashes parking lights once.
- Press the lock button on each remote. System beeps once per programmed remote.
Note: For 2-Way remotes, wait for the remote beep before programming the next.
Feature Programming
Features can be programmed using the valet button and an OEM or Prestige remote. To enter Feature Bank programming:
- Turn ignition key to ON.
- Press and release the valet button three times (Feature Bank 1, Remote Programming).
- Cycle ignition key OFF/ON (Feature Bank 2).
- Press valet button to cycle features (LED flashes feature number).
- Press lock button to cycle options (System beeps option number).
Chirp Delete: Toggle system ARM/DISARM chirps ON/OFF by turning ignition ON/OFF, then pressing and releasing the valet button three times. The system will chirp once for ON, twice for OFF.
User Programmable LED: Turn system LED notifications ON/OFF by turning ignition ON/OFF twice, then pressing and holding the valet button for five seconds. LED flashes once for ON, twice for OFF.
Shock Sensor Adjustment
Mount the shock sensor to a solid surface in the center of the vehicle. Adjust sensitivity by turning the dial clockwise (increase) or counter-clockwise (decrease). Test by striking the vehicle and adjusting for optimal coverage.
Dome Delay Programming
This feature ignores the vehicle's theater dimming dome light when connecting the door trigger input to the dome light circuit. Ensure vehicle windows are open.
- With doors closed and dome light off, press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED lights solid.
- Open and close the driver door. The system monitors the dome light circuit and sets the delay time plus an additional two seconds when the dome light turns off.
Dome Delay Reset: Turn ignition ON/OFF three times, then press and hold the valet button for five seconds. System beeps once to confirm reset.
Data Protocol Selection
The default data port protocol is ADS (iDatalink 2-Way). The system can auto-detect ADS or DBI. To initialize detection:
- Press and hold the valet button.
- Cycle the vehicle's ignition ON/OFF twice.
- Release the valet button.
The system automatically detects and sets the correct protocol. Alternatively, set Feature Bank 2, Feature 15 to DBI.
Negative Output Control (NOC) & AUX Output Control & PIC Input Control
These features allow for advanced customization of outputs and inputs and are accessible via FlashLogic Weblink or Weblink Mobile. Options include various pulse durations, push & hold, latch ON/OFF for AUX outputs, and specific input configurations for door triggers, hood/trunk triggers, and shock sensors.
Important Update: When flashing FLCAN or other integration modules, select iDatalink 2-Way as the installation method. This module also supports DBI, which requires programming Feature Bank 2, Feature 15 to DBI.
Feature Bank Table
Features | Options | Description |
---|---|---|
1 Lock/Unlock Function | 500ms, 3.5sec, 500ms L, DBL UL, DBL L, 500ms UL, DBL L, DBL UL, 500ms L, 350ms UL | Configures lock/unlock pulse timings and sequences. |
2 Ignition Lock | OFF, ON | Enables automatic door locking upon ignition ON. |
3 Ignition Unlock | Unlock All, Driver Unlock | Configures unlock behavior upon ignition OFF. |
4 Exterior Illumination | OFF, With Arm, With Arm & Disarm | Controls parking light flashes for arming/disarming. |
5 Auto Relock | OFF, Auto Lock Only, Auto Lock & Arm | Sets automatic relocking behavior. |
6 Auto Arming / Locking | OFF, Auto Arm Only, Auto Lock & Arm | Configures automatic arming and locking. |
7 Notification Sound | Both, Siren, Horn | Selects the sound for system notifications. |
8 Horn Timing | 16ms, 30ms, 40ms | Sets the duration of the horn chirp. |
9 Valet Override Method | Valet, Custom Code | Determines the method for valet mode override. |
10 Driver Priority Unlock | OFF, ON | Enables unlocking only the driver's door first. |
11 Silent Choice | OFF, ON | Toggles silent arming/disarming. |
12 Security Profile | All On, Doors Off, Hood/trunk Off, All Off | Configures which sensors are active. |
13 Door Trigger Input | Negative, Positive | Sets the polarity for the door trigger input. |
14 Park Light / Trunk Swap | OFF, ON | Swaps the function of the parking light and trunk outputs. |
15 Data Port Protocol | ADS, DBI, OEM Style | Selects the data protocol for communication. |
16 1 or 2 Wire Disarm | 1 Wire, 2 Wire | Configures the disarm input for single or dual wire systems. |
17 Disarm Input | 120ms Dr OR Pass, 80ms Dr OR Pass, 120ms, UL & Light, 80ms, UL & Light | Sets timing and conditions for disarm input. |
18 Arm 1 Input | Auto Detect, Positive, Negative | Configures the polarity for Arm Input 1. |
19 Disarm 1 Input | Auto Detect, Positive, Negative | Configures the polarity for Disarm Input 1. |
20 Arm 2 Input | Auto Detect, Positive, Negative | Configures the polarity for Arm Input 2. |
21 Disarm 2 Input | Auto Detect, Positive, Negative | Configures the polarity for Disarm Input 2. |
22 Trunk Shunt Input | Auto Detect, Positive, Negative | Configures the polarity for the trunk shunt input. |
23 Dome Light Delay Timer | OFF/Program, 15sec, 30sec | Sets the delay for the dome light output. |
24 Alarm Trigger Length | 30sec, 45sec, 60sec, 45sec, 90sec, 60sec, 120sec, 120sec | Sets the duration of the alarm trigger. |