Prestige APS901Z Remote Start System
Quick Installation Guide
Important Update
The default Data Port Protocol for this system is ADS. If using an FLCAN or other external integration module, ensure iDatalink 2-Way is selected when flashing. This system also supports DBI, which requires programming Feature Bank 2, Feature 18 to DBI.
System Layout and Wiring
Harnesses and Connections
6-Pin RS Harness:
- 1: Yellow - Starter Output (+)
- 2: Green - Ignition 2 Output (+)
- 3: Red - Battery 12V Input (+)
- 4: Red/White - Battery 12V Input (+)
- 5: Purple - Accessory Output (+)
- 6: Blue - Ignition Input/Output (+)
Replacement Part #: 4120467
4-Pin Light Harness:
- 1: White - Parking Light (30) Output
- 2: White/Red - Parking Light (87) Input
- 3: Yellow/Black - Ignition Output For Alarm (+)
- 4: Black - Ground Input (-)
Replacement Part #: 4120463
14-Pin Main Input/Output Harness
- 14: Green/Orange - Tach Input
- 13: Black/Yellow - Pulse During Crank Output (-)
- 12: Green/Yellow - Glow Plug Input (+)
- 11: Black/Red - Pulse After Shutdown Output (-)
- 10: Empty
- 9: Black/Blue - Factory Disarm Output (-)
- 8: Brown/Black - Brake Input (+)
- 7: Black/Lt. Green - Factory Arm Output (-)
- 6: Dk. Blue/Black - Remote Start Status Output (-)
- 5: Lt. Blue - Unlock Output (-)
- 4: Green - Empty
- 3: Gray/Black - Hood Input (-)
- 2: Empty
- 1: Black/White - Horn Output (-)
Replacement Part #: 4120466
Other Connections
- Antenna: Replacement Part #: 4360841
- Valet Switch: Replacement Part #: 4180070
- LED: Replacement Part #: 4120465
- CarLink: Replacement Part #: 4120465
Accessory parts sold separately.
Programming Features
Tach Programming
The installer must manually configure the Engine Confirmation method in Feature Bank 3, Feature 5. The default method is "Tach". When using the default "Tach" method, the vehicle tach rate must be programmed.
To enter tach rate programming:
- Turn the ignition key ON.
- Press and release the valet button three (3) times.
- Turn the ignition key OFF.
- Press and hold the valet button.
- While holding the valet button, start the engine using the key.
- Hold the valet button for approximately ten (10) seconds. If connected to the vehicle Tach source, the system will flash the parking lights one (1) time every second.
- Release the valet button. The system will turn on the parking lights for two (2) seconds to indicate the tach rate is programmed.
Programming tach signal via OEM or Carlink control is only available on Firmware v1.47 or Higher.
Feature Banks
The Feature Banks can be programmed using the valet button and remote, or via FlashLogic Weblink (visit www.FlashLogic.com for details).
To enter Feature Bank programming:
- Turn the ignition key ON.
- Press and release the valet button three (3) times. The system will beep and flash the parking lights one (1) time for Feature Bank 1 (Remote Programming).
- Cycle the ignition key OFF/ON. The system will beep and flash the parking lights two (2) times for Feature Bank 2.
- Cycle the ignition key OFF/ON. The system will beep and flash the parking lights three (3) times for Feature Bank 3.
- Press the valet button to cycle through features. The LED will flash to display the feature number.
- Press the Start button to cycle through options. The system will beep to indicate the option number.
- Cycle ignition key OFF/ON to save settings.
Data Protocol Selection
The default data port protocol is ADS. The system can detect and automatically configure the correct protocol (ADS or DBI) by programming Feature Bank 2, Feature 18.
To initialize the detection procedure:
- Press and hold the valet button.
- Cycle the vehicle's Ignition ON/OFF two (2) times.
- Release the valet button.
The system will automatically detect and set the correct data port protocol. Note: This feature is only available on module firmware v2.0 or higher.
Notifications
The system will flash the vehicle parking lights to indicate the cause of remote start failure.
- 1: Runtime Expired
- 2: Remote Shutdown
- 3: Brake On
- 4: Manual Mode
- 5: Hood Open
- 6: Low / No Tach
- 7: Tach Programming
- 8: High Tach
Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering Feature Bank programming.
- Turn the ignition key ON/OFF.
- Press and release the valet button three (3) times.
The system will respond with one (1) chirp for ON and two (2) chirps for OFF.
User Programmable LED
System LED notifications can be turned ON or OFF without entering Feature Bank programming.
- Turn the ignition key ON/OFF, ON/OFF.
- Press and hold the valet button for five (5) seconds.
The LED will flash one (1) time for ON, two (2) times for OFF.
Remote Programming
The APS901Z includes two (2) programmed remote controls. Additional remotes can be programmed.
To enter Remote Auto Programming:
- Press and release the valet button three (3) times. The system will beep and flash the parking lights one (1) time.
- Press the Start button on each remote. The system will beep one (1) time to indicate the remote has been programmed.
OEM Security
This system can provide OEM level security. It monitors the analog hood input and all entry zone inputs from integration modules. When an entry zone is detected, the system will beep the vehicle horn and flash the parking lights. This feature must be activated in Feature Bank 2, Feature 17.
Operation
- Arm: Press the start button one (1) time.
- Disarm: Press the start button two (2) times.
- Start: Press and hold the start button for three (3) seconds.
Valet Override Procedure
To disarm the system without a remote, turn the ignition key to ON and press the valet button one (1) time.
Feature Bank Details
Feature Bank 2
Feature | Options |
---|---|
1 Chirp | 1 Chirp, 2 Chirp, 3 Chirp, 4 Chirp, 5 Chirp, 6 Chirp |
2 Accessory Lock | NA |
3 Accessory Unlock | NA |
4 Exterior Illumination | NA |
5 Auto Relock | NA |
6 Auto Arming | NA |
7 Notification Sound | NA |
8 Horn Timing | 10ms, 16ms, 30ms, 40ms, 50ms |
9 Valet Override Method | NA |
10 Driver Priority Unlock | NA |
11 Silent Choice | NA |
12 Park Light / Trunk Swap | NA |
13 AUX Ch. 4 | NA |
14 AUX Ch. 5 | NA |
15 AUX Ch. 6 | NA |
16 AUX Ch. 7 | NA |
17 Security Profile | OEM Security W/OEM Remote Start, OFF, OFF W/ Keyless |
18 Data Port Protocol | ADS, DBI |
Feature Bank 3
Feature | Options |
---|---|
1 RS Start Notification | ON, OFF |
2 RS Runtime | 5min, 10min, 15min, 20min, 45min, 60min |
3 Lock/Unlock Function | 500ms, 3.5sec, 500ms L, DBL UL, DBL L, 500ms UL, DBL L, DBL UL |
4 RS Parking Lights | Steady, Flashing |
5 Engine Confirmation | Tach, Voltage, Data, Hybrid |
6 Voltage Level | >0.5v B4 Start, <0.5v B4 Start |
7 Ignition 2 Output | Ignition, Accessory, Start |
8 Ignition 3 Output | N/A |
9 Accessory Output | Accessory, Ignition, Start |
10 Transmission | NA |
11 Max Crank Time | 0.8sec, 1.0sec, 1.5sec, 2.0sec, 3.0sec, 4.0sec |
12 Diesel Delay | OFF, Diesel 5, Diesel 10, Diesel 15, Diesel 20, Diesel 30 |
13 Temperature Start | NA |
14 Crank Duration | Averaging, Preset |
15 RS Shock Override | NA |
16 Turbo Timer | NA |
17 Start Activation | Two Press, One Press, Three Press |
18 RS Lock Function | No Change, UL Before L After, UL Before Start, Lock After Start |
19 Factory Disarm Output | Single Pulse, 350ms, 500ms, 800ms |
20 Pulse During Crank | During Crank, GWR, Ignition, Accessory |
21 Factory Arm Output | After Start, GWR, Ignition, Accessory |
22 Pulse After Shutdown | After Shutdown, GWR, Ignition, Accessory |
23 Additional Unlock Pulse | NA |