Prestige APS901Z Remote Start System

Quick Installation Guide

Important Update

The default Data Port Protocol for this system is ADS. If using an FLCAN or other external integration module, ensure iDatalink 2-Way is selected when flashing. This system also supports DBI, which requires programming Feature Bank 2, Feature 18 to DBI.

System Layout and Wiring

Harnesses and Connections

6-Pin RS Harness:

Replacement Part #: 4120467

4-Pin Light Harness:

Replacement Part #: 4120463

14-Pin Main Input/Output Harness

Replacement Part #: 4120466

Other Connections

Accessory parts sold separately.

Programming Features

Tach Programming

The installer must manually configure the Engine Confirmation method in Feature Bank 3, Feature 5. The default method is "Tach". When using the default "Tach" method, the vehicle tach rate must be programmed.

To enter tach rate programming:

  1. Turn the ignition key ON.
  2. Press and release the valet button three (3) times.
  3. Turn the ignition key OFF.
  4. Press and hold the valet button.
  5. While holding the valet button, start the engine using the key.
  6. Hold the valet button for approximately ten (10) seconds. If connected to the vehicle Tach source, the system will flash the parking lights one (1) time every second.
  7. Release the valet button. The system will turn on the parking lights for two (2) seconds to indicate the tach rate is programmed.

Programming tach signal via OEM or Carlink control is only available on Firmware v1.47 or Higher.

Feature Banks

The Feature Banks can be programmed using the valet button and remote, or via FlashLogic Weblink (visit www.FlashLogic.com for details).

To enter Feature Bank programming:

  1. Turn the ignition key ON.
  2. Press and release the valet button three (3) times. The system will beep and flash the parking lights one (1) time for Feature Bank 1 (Remote Programming).
  3. Cycle the ignition key OFF/ON. The system will beep and flash the parking lights two (2) times for Feature Bank 2.
  4. Cycle the ignition key OFF/ON. The system will beep and flash the parking lights three (3) times for Feature Bank 3.
  5. Press the valet button to cycle through features. The LED will flash to display the feature number.
  6. Press the Start button to cycle through options. The system will beep to indicate the option number.
  7. Cycle ignition key OFF/ON to save settings.

Data Protocol Selection

The default data port protocol is ADS. The system can detect and automatically configure the correct protocol (ADS or DBI) by programming Feature Bank 2, Feature 18.

To initialize the detection procedure:

  1. Press and hold the valet button.
  2. Cycle the vehicle's Ignition ON/OFF two (2) times.
  3. Release the valet button.

The system will automatically detect and set the correct data port protocol. Note: This feature is only available on module firmware v2.0 or higher.

Notifications

The system will flash the vehicle parking lights to indicate the cause of remote start failure.

Chirp Delete

System ARM/DISARM chirps can be toggled ON or OFF without entering Feature Bank programming.

  1. Turn the ignition key ON/OFF.
  2. Press and release the valet button three (3) times.

The system will respond with one (1) chirp for ON and two (2) chirps for OFF.

User Programmable LED

System LED notifications can be turned ON or OFF without entering Feature Bank programming.

  1. Turn the ignition key ON/OFF, ON/OFF.
  2. Press and hold the valet button for five (5) seconds.

The LED will flash one (1) time for ON, two (2) times for OFF.

Remote Programming

The APS901Z includes two (2) programmed remote controls. Additional remotes can be programmed.

To enter Remote Auto Programming:

  1. Press and release the valet button three (3) times. The system will beep and flash the parking lights one (1) time.
  2. Press the Start button on each remote. The system will beep one (1) time to indicate the remote has been programmed.

OEM Security

This system can provide OEM level security. It monitors the analog hood input and all entry zone inputs from integration modules. When an entry zone is detected, the system will beep the vehicle horn and flash the parking lights. This feature must be activated in Feature Bank 2, Feature 17.

Operation

Valet Override Procedure

To disarm the system without a remote, turn the ignition key to ON and press the valet button one (1) time.

Feature Bank Details

Feature Bank 2

FeatureOptions
1 Chirp1 Chirp, 2 Chirp, 3 Chirp, 4 Chirp, 5 Chirp, 6 Chirp
2 Accessory LockNA
3 Accessory UnlockNA
4 Exterior IlluminationNA
5 Auto RelockNA
6 Auto ArmingNA
7 Notification SoundNA
8 Horn Timing10ms, 16ms, 30ms, 40ms, 50ms
9 Valet Override MethodNA
10 Driver Priority UnlockNA
11 Silent ChoiceNA
12 Park Light / Trunk SwapNA
13 AUX Ch. 4NA
14 AUX Ch. 5NA
15 AUX Ch. 6NA
16 AUX Ch. 7NA
17 Security ProfileOEM Security W/OEM Remote Start, OFF, OFF W/ Keyless
18 Data Port ProtocolADS, DBI

Feature Bank 3

FeatureOptions
1 RS Start NotificationON, OFF
2 RS Runtime5min, 10min, 15min, 20min, 45min, 60min
3 Lock/Unlock Function500ms, 3.5sec, 500ms L, DBL UL, DBL L, 500ms UL, DBL L, DBL UL
4 RS Parking LightsSteady, Flashing
5 Engine ConfirmationTach, Voltage, Data, Hybrid
6 Voltage Level>0.5v B4 Start, <0.5v B4 Start
7 Ignition 2 OutputIgnition, Accessory, Start
8 Ignition 3 OutputN/A
9 Accessory OutputAccessory, Ignition, Start
10 TransmissionNA
11 Max Crank Time0.8sec, 1.0sec, 1.5sec, 2.0sec, 3.0sec, 4.0sec
12 Diesel DelayOFF, Diesel 5, Diesel 10, Diesel 15, Diesel 20, Diesel 30
13 Temperature StartNA
14 Crank DurationAveraging, Preset
15 RS Shock OverrideNA
16 Turbo TimerNA
17 Start ActivationTwo Press, One Press, Three Press
18 RS Lock FunctionNo Change, UL Before L After, UL Before Start, Lock After Start
19 Factory Disarm OutputSingle Pulse, 350ms, 500ms, 800ms
20 Pulse During CrankDuring Crank, GWR, Ignition, Accessory
21 Factory Arm OutputAfter Start, GWR, Ignition, Accessory
22 Pulse After ShutdownAfter Shutdown, GWR, Ignition, Accessory
23 Additional Unlock PulseNA
Models: APS-901, Remote Start System

File Info : application/pdf, 2 Pages, 701.52KB

PDF preview unavailable. Download the PDF instead.

APS901Z QS

References

Adobe PDF Library 15.0 Adobe InDesign 15.1 (Windows)

Related Documents

PreviewPrestige APS901Z Vehicle Remote Start System Installation and Reference Guide
Comprehensive installation and reference guide for the Prestige APS901Z Vehicle Remote Start System. This guide details wire harness functions, external components, setup options, system programming, and wiring diagrams for professional installers.
PreviewPrestige APS787Z Security and Remote Start System Quick Installation Guide
Provides system layout, wiring details, and quick installation instructions for the Prestige APS787Z car security and remote start system, including programming and feature customization.
PreviewPrestige APS510Z Security System Quick Installation Guide
This document provides a quick installation guide for the Prestige APS510Z Security System with Keyless Entry. It covers system features, programming, and sensor adjustments.
PreviewPrestige APS57TM Remote Start System Installation Guide
This document provides installation and programming information for the Prestige APS57TM Remote Start System, including wiring diagrams, feature bank settings, and troubleshooting tips.
PreviewPrestige APS997Z Security and Remote Start System Layout and Guide
This document provides the system layout, wiring diagrams, and installation guide for the Prestige APS997Z Security and Remote Start system. It details connections, feature programming, and remote installation.
PreviewPrestige APS596Z Security with Keyless Entry System Layout and Installation Guide
This document provides the system layout and quick installation guide for the Prestige APS596Z Security with Keyless Entry system. It details wiring connections, feature programming, remote programming, and sensor setup.
PreviewPrestige 18LCDLORTI Remote Transmitter User Manual
User manual for the Prestige 18LCDLORTI remote transmitter, detailing its features, button functions, specifications, and FCC compliance. Includes information on Lora 2-Way technology and range.
Preview185BPTI/185BPRTI Transmitter Manual
User manual for the 185BPTI/185BPRTI remote transmitter, detailing its features, specifications, button functions, and FCC compliance information.