Datasheet for SIMPSON models including: S-A-PG22 Anchoring Fastening Restoration and Strengthening Systems, S-A-PG22, Anchoring Fastening Restoration and Strengthening Systems, Restoration and Strengthening Systems, Strengthening Systems
S-A-PG22
20222025 Product Guide Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry (800) 999-5099 | strongtie.com Taking testing and service to new heights. For over sixty-five years, Simpson Strong-Tie has believed the only true strength is tested strength. That's why our products are rigorously tested and load rated. But we also know every construction project is unique. So we frequently take the added step of offering full-scale application testing. Which means that whatever your design and building specs, we can create real-world conditions in our university-grade labs to make sure our products will work in your project. It's just another example of how we exceed other manufacturers' practices to ensure your success. From design services to technical support to cutting-edge software -- like Anchor DesignerTM -- we're uncompromising in our quest to help you design the best solution for your building challenges. 2 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Simpson Strong-Tie Company Inc. The Simpson Strong-Tie Company Inc. No Equal Pledge® includes: · Quality products value-engineered for the lowest installed cost at the highest-rated performance levels · The most thoroughly tested and evaluated products in the industry · Strategically located manufacturing and warehouse facilities · National code agency listings · The largest number of patented connectors in the industry · Global locations with an international sales team · In-house R&D and tool and die professionals · In-house product testing and quality control engineers · Support of industry groups including AISI, AITC, ASTM, ASCE, AWC, AWPA, ACI, AISC, CSI, CFSEI, ICFA, NBMDA, NLBMDA, SBCA, SDI, SETMA, SFA, SFIA, STAFDA, SREA, NFBA, TPI, WDSC, WIJMA, WTCA and local engineering groups Product Identification Key Products and additional information are divided into general categories, identified by tabs along the page's outer edge. Adhesive Anchors 1849 Mechanical Anchors 50107 The Simpson StrongTie Quality Policy We help people build safer structures economically. We do this by designing, engineering and manufacturing No Equal® structural connectors and other related products that meet or exceed our customers' needs and expectations. Everyone is responsible for product quality and is committed to ensuring the effectiveness of the Quality Management System. Direct Fastening Solutions 108137 Restoration Solutions 138175 Karen Colonias Chief Executive Officer Carbide Drill Bits 176185 We Are ISO 9001 Registered Simpson Strong-Tie is an ISO 9001 registered company. ISO 9001 is an internationally recognized quality management system that lets our domestic and international customers know they can count on the consistent quality of Simpson Strong-Tie products and services. (800) 999-5099 | strongtie.com All Rights Reserved. This guide may not be reproduced in whole or in part without the prior written approval of Simpson StrongTie Company Inc. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Appendix Alphabetical Index of Products 186213 214217 3 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Table of Contents Adhesive Anchors Adhesive Accessories............................................................................... 28 Adhesive Anchoring Installation Instructions.............................................. 42 Adhesive Retaining Caps.......................................................................... 35 All Thread Rod (ATR)................................................................................ 41 AT-XP® Acrylic Adhesive........................................................................... 26 ET-HP® Epoxy Adhesive........................................................................... 24 Hole-Cleaning Brushes............................................................................. 31 Opti-Mesh Adhesive-Anchoring Screen Tubes.......................................... 36 Piston Plug Delivery System..................................................................... 33 Retrofit Bolts (RFB)................................................................................... 40 SET-3GTM Epoxy Adhesive......................................................................... 20 SET-XP® Epoxy Adhesive.......................................................................... 22 Steel Adhesive-Anchoring Screen Tubes................................................... 38 Mechanical Anchors Crimp Drive® Anchor............................................................................... 102 CSD/DSD Split-Drive Anchors................................................................ 105 Drop-In Internally Threaded Anchor (DIAB)................................................ 88 Drop-In Internally Threaded Anchor (DIA).................................................. 94 Easy-Set Pin-Drive Expansion Anchor...................................................... 71 Hollow Drop-In Anchor............................................................................. 96 Sleeve-All® Sleeve Anchor........................................................................ 68 Steel Rod Hanger..................................................................................... 83 Strong-Bolt® 2 Stainless-Steel Wedge Anchor.......................................... 64 Strong-Bolt 2 Wedge Anchor.................................................................... 64 Sure Wall Drywall Anchor........................................................................ 107 Tie-Wire Wedge Anchor........................................................................... 73 Titen HD® Countersunk Screw Anchor..................................................... 54 Titen HD Stainless-Steel Countersunk Screw Anchor............................... 60 Titen HD Heavy-Duty Screw Anchor......................................................... 52 Titen HD Stainless-Steel Heavy-Duty Screw Anchor................................. 58 Titen HD Washer-Head Screw Anchor...................................................... 55 Titen® Stainless-Steel Concrete and Masonry Screw................................ 79 Titen TurboTM Screw Anchor...................................................................... 74 Titen HD Threaded Rod Hanger............................................................... 81 Titen HD Rod Coupler.............................................................................. 62 Wood Rod Hanger................................................................................... 86 Zinc NailonTM Pin Drive Anchors............................................................... 100 New products are shown with the symbol. 4 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Table of Contents Direct Fastening Solutions Extension Pole Tools............................................................................... 120 Gas-Actuated Fasteners and Accessories.............................................. 116 Gas Tool / Fastener Suitability................................................................. 112 GCN-MEPMAGKT Concrete Nailer......................................................... 114 Powder-Actuated Fasteners................................................................... 132 Powder-Actuated Tool / Fastener Suitability............................................ 110 Powder-Actuated Tool / Fastener Matrix................................................. 131 Powder-Actuated Tool Matrix.................................................................. 121 Powder Loads........................................................................................ 129 PTP-27L................................................................................................. 122 PT-27..................................................................................................... 124 PT-22A................................................................................................... 126 PT-22HA................................................................................................. 128 Restoration Solutions CIP-F Flexible Paste-Over Adhesive and Crack Sealant.......................... 154 CIP-LO Low Odor Paste-Over Epoxy and Crack Sealant........................ 154 Crack Injection Guide............................................................................. 157 Crack Injection Epoxy............................................................................. 140 Crack-Pac® Flex-H2OTM........................................................................... 152 Crack-Pac Injection Epoxy...................................................................... 150 Crack Repair Accessories....................................................................... 156 CSS V-WrapTM Composite Strengthening SystemsTM................................ 172 Epoxy Injection Guide ............................................................................ 162 ETR Concrete Repair and Paste-Over Epoxy ......................................... 155 Heli-TieTM Helical Stitching Tie.................................................................. 170 Heli-Tie Helical Wall Tie........................................................................... 166 Carbide Drill Bits and Accessories Core Bits................................................................................................ 183 Demolition Bits....................................................................................... 184 SDS-max® Drill Bits................................................................................ 181 SDS-plus® Drill Bits................................................................................. 178 Straight Shank Drill Bits.......................................................................... 182 Appendix Acceptable Hole Diameter...................................................................... 211 Anchor Products for Corrosive Environments.......................................... 188 Anchoring and Fastening Applications by Market.................................... 187 Length Identification Head Marks............................................................ 210 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 5 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Important Information and General Notes Limited Warranty For the Limited Warranty that applies to Simpson Strong-Tie products, please consult strongtie.com/limited-warranties. To obtain a copy of the current Limited Warranty, contact us at limited_warranty@strongtie.com, (800) 999-5099 or Simpson Strong-Tie Company Inc., 5956 West Las Positas Boulevard, Pleasanton, CA 94588. The Limited Warranty contains important disclaimers, limitations and exclusions, and applies only if the products have been properly specified, installed, maintained, and used in accordance with the design limits and the structural, technical, and environmental specifications in the Simpson Strong-Tie Documentation. All future purchases of Simpson Strong-Tie products are subject to the terms of the Limited Warranty in effect as of the purchase date. Although products are designed for a wide variety of uses, Simpson Strong-Tie assumes no liability for confirming that any product is appropriate for an intended use, and each intended use of a product must be reviewed and approved by qualified professionals. Each product is designed for the load capacities and uses listed in the Simpson Strong-Tie Documentation, subject to the limitations and other information set forth therein. Due to the particular characteristics of potential impact events such as earthquakes and high velocity winds, the specific design and location of the structure, the building materials used, the quality of construction, or the condition of the soils or substrates involved, damage may nonetheless result to a structure and its contents even if the loads resulting from the impact event do not exceed Simpson Strong-Tie's specifications and the products are properly installed in accordance with applicable building codes, laws, rules and regulations. 6 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Important Information and General Notes Terms and Conditions of Sale Product Use Products in this catalog are designed and manufactured for the specific purposes shown, and should not be used with other connectors not approved by a qualified licensed/certified building design professional, a licensed professional engineer or licensed architect ("designer"). You should review our website and consult a qualified designer familiar with all applicable building codes each time you use a Simpson Strong-Tie product. Indemnity Any designer or other person who modifies any products, changes any installation procedures or designs any non-catalog products for fabrication by Simpson Strong-Tie Company Inc. shall, regardless of specific instructions to the user, indemnify, defend, and hold harmless Simpson Strong-Tie Company Inc. for any and all claimed loss or damage occasioned in whole or in part by such products. Non-Catalog and Modified Products Modifications to products or changes in installation procedures should only be made by a qualified professional designer. The performance of such modified products or altered installation procedures is the sole responsibility of the designer. Any person modifying Simpson Strong-Tie products must provide the installer with specific instructions on the modified products' specifications, installation and use. Consult Simpson Strong-Tie Company Inc. for applications for which there is no catalog product, or for connectors for use in hostile environments, with excessive wood shrinkage, or with abnormal loading or erection requirements. Non-catalog products must be designed by a qualified designer and will be fabricated by Simpson Strong-Tie in accordance with customer specifications. Any modified, special order or non-catalog products, or any products that are not installed strictly in accordance with Simpson Strong-Tie installation procedures, are provided "AS IS" and without any representation or warranty of any kind. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 7 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 8 Adhesive Anchors Product SET-3GTM SET-XP® ET-HP® AT-XP® Tested Base Materials and Code Listings Page No. Concrete Concrete on CMU Unreinforced Clay Brick Cracked Uncracked Metal Deck Grout-Filled Hollow Masonry Other Listings 20 ESR-4057 (COLA), FL15730 ASTM C881/ -- -- -- -- AASHTO M235, DOT, CDPH Std. Method v1.2, NSF/ANSI/CAN 61 22 ESR-2508 (COLA), FL15730 -- ER-265 (COLA), FL16230 ASTM C881/ -- AASHTO M235, DOT, CDPH Std. Method v1.2, NSF/ANSI/CAN 61 24 ESR-3372 (COLA), FL15730 -- ER-241 (COLA), FL16230 -- ESR-3638 (COLA) ASTM C881/ AASHTO M235, DOT ASTM C881/ 26 ER-263 (COLA), FL16230 -- ER-281 (COLA), FL16230 -- AASHTO M235, DOT, CDPH Std. Method v1.2, NSF/ANSI/CAN 61 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Product Selection Guide 9 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Restoration Solutions CI-SLV CI-LV CI-LV FS CI-LPL CI-GV Crack-Pac® Refer to footnotes on p. 15. 140 -- -- -- -- -- -- 142 -- -- -- -- -- -- 144 -- -- -- -- -- -- 146 -- -- -- -- -- -- 148 -- -- -- -- -- -- 150 -- -- -- -- -- -- ASTM C881/ AASHTO M235 ASTM C881/ AASHTO M235 NSF/ANSI/CAN 61 ASTM C881/ AASHTO M235 ASTM C881/ AASHTO M235 ASTM C881/ AASHTO M235 ASTM C881/ AASHTO M235 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Product Selection Guide S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 10 Restoration Solutions Product Crack-Pac® Flex H2O Heli-TieTM CIP-LO CIP-F ETR Tested Base Materials and Code Listings Page No. Concrete Concrete on CMU Unreinforced Clay Brick Cracked Uncracked Metal Deck Grout-Filled Hollow Masonry 152 -- -- -- -- -- -- Other Listings -- 166 -- Non-IBC -- Non-IBC Non-IBC Non-IBC Wood Metal Stud 154 -- -- -- -- -- -- -- 154 -- -- -- -- -- -- -- 155 -- -- -- -- -- -- -- Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Product Selection Guide 11 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Product Titen HD® (THD) Stainless-Steel Titen HD (THD-SS) Titen HD® Countersunk (THD-CS) Stainless-Steel Titen HD Countersunk (THD-CS-SS) Titen HD Washer Head (THD-WH) Refer to footnotes on p. 15. Tested Base Materials and Code Listings Page No. Concrete Concrete on CMU Unreinforced Clay Brick Other Cracked Uncracked Metal Deck Grout-Filled Hollow Masonry 52 ESR-2713 (COLA), FL15730 ESR-1056 (COLA), -- -- -- FL15730 Other Listings FM, DOT 58 ER-493 (COLA), FL16230 ESR-1056 (COLA), FL15730 -- -- DOT 54 ESR-2713 (COLA), FL15730 ESR-1056 (COLA), -- -- -- DOT FL15730 60 ER-493 (COLA), FL16230 ESR-1056 (COLA), FL15730 -- -- DOT 55 ESR-2713 (COLA) FL 15730 IBC -- -- DOT Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Product Selection Guide S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 12 Mechanical Anchors Product Titen HD® Rod Coupler (THD-RC) Titen HD Threaded Rod Hanger (THD-RH) Strong-Bolt® 2 (STB2) Sleeve-All® (SL) Easy-Set (EZAC) Tested Base Materials and Code Listings Page No. Concrete Concrete on CMU Unreinforced Clay Brick Other Cracked Uncracked Metal Deck Grout-Filled Hollow Masonry Other Listings 62 ESR-2713 (COLA), FL15730 IBC -- -- -- -- 81 ESR-2713 (COLA), FL15730 IBC -- -- -- FM 64 ESR-3037 (COLA), FL15730 ER-240 (COLA), -- FL16230 -- -- UL, FM, DOT 68 -- Non-IBC -- Non-IBC -- -- -- UL, FM, DOT 71 -- Non-IBC -- -- -- -- -- -- Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Product Selection Guide 13 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Tie-Wire (TW) Titen TurboTM (TNT) Stainless-Steel Titen® (TTN) Steel Rod Hanger (RSH, RSV) Wood Rod Hanger (RWH, RWV) Drop-In (DIAB) Refer to footnotes on p. 15. 73 -- Non-IBC Non-IBC -- -- -- -- -- ER-712 74 -- (COLA), -- FL16230 ER-716 (COLA), FL16230 -- -- -- 79 -- FL2355 -- FL2355 -- -- -- 83 -- -- -- -- -- -- IBC (Steel) UL, FM 86 -- -- -- -- -- -- IBC (Wood) UL, FM 88 -- Non-IBC Non-IBC -- -- -- -- UL, FM Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Product Selection Guide S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 14 Mechanical Anchors Product Drop-In Anchor (Stainless Steel: DIA-SS) (Short: DIA-S) Hollow Drop-In (HDIA) Zinc NailonTM (ZN) Crimp Drive® (CD) Split Drive (CSD, DSD) Tested Base Materials and Code Listings Page No. Concrete Concrete on CMU Unreinforced Clay Brick Other Cracked Uncracked Metal Deck Grout-Filled Hollow Masonry Other Listings Non-IBC 94 -- Non-IBC Non-IBC -- -- -- (Hollow-Core Concrete UL, FM, DOT Panel) Non-IBC 96 -- Non-IBC -- -- IBC -- (Hollow-Core Concrete UL,FM Panel) 100 -- Non-IBC -- -- -- -- -- -- 102 -- Non-IBC Non-IBC -- -- -- -- FM 105 -- Non-IBC -- -- -- -- -- -- Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Product Selection Guide Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Product Selection Guide S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Sure Wall (SWN, SWZ) 107 -- -- -- -- -- -- Drywall -- Direct Fastening Powder-Actuated Fasteners Gas-Actuated Fasteners 132 -- 116 -- ESR-2138 (COLA), FL15730 ESR-2811 (COLA), FL15730 Steel, -- ESR-2138 (COLA), -- FL15730 Steel, -- ESR-2811 (COLA), -- FL15730 ESR -- ICC-ES code report available at icc-es.org. ER -- IAPMO UES code report available at iapmoes.org. COLA -- City of Los Angeles Supplement within the ICC-ES or IAPMO UES code report. See supplement for LA Building Code compliance. FL -- Florida building code approval available. IBC -- Load data is available in this catalog intended for use under IBC, but code listings are not available. Non-IBC -- Load data is available in this catalog, but it is outside the scope of the current IBC. May be permitted for non-IBC applications. UL -- Underwriters Laboratories listing available. FM -- Factory Mutual listing available. DOT -- Various departments of transportation listings available. See strongtie.com/DOT for details. Consult the code listings for more detailed information on which models of each product are covered by the listing. 15 RDLC Anchor Software and Web Apps Rebar Development Length Calculator Rebar Development Length Calculator Rebar Development Length Calculator is a web application that supports the design of post-installed rebar in concrete applications by calculating the necessary tension and compression development lengths required in accordance with ACI 318-19 / ACI 318-14. Visit: strongtie.com/softwareandwebapplications/category ACE Adhesive Cartridge Estimator Adhesive Cartridge Estimator With the Adhesive Cartridge Estimator you can easily estimate how much adhesive you will need for your project, including threaded rod and rebar doweling, and crack injection. Visit: strongtie.com/softwareandwebapplications/category 16 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. AD Anchor DesignerTM Anchor DesignerTM Software for ACI 318, ETAG and CSA Simpson Strong-Tie® Anchor Designer Software is the latest anchorage design tool for structural engineers to satisfy the strength design provisions and methodologies. Anchor Designer will quickly and accurately analyze an existing design or suggest anchorage solutions based upon userdefined design elements in cracked and uncracked concrete conditions. The real-time design is visually represented in a fully-interactive 3D graphic user interface, supports Imperial and Metric-sized Simpson Strong-Tie mechanical and adhesive anchors, and offers cast-in-place anchor solutions. Anchor Designer can calculate single anchor solutions or with multiple anchors in a single plate. Anchor locations are fully customizable to assist engineers in complex design conditions. Features include: · Design standards: ACI 318 Chapter 17 / ACI 318-11 Appendix D, CAN / CSA A23.3 Annex D, ETAG 001 Annex C or EOTA TR029. · Customizable anchor pattern. · Easy-to-use menus. · Ability to calculate single anchor model or to calculate multiple anchor models at once. · Multi-lingual options include English, German, French, Spanish, Polish and Danish languages. · Rectangular, circular, L-shape and T-shape base plate geometries with the option to include slotted holes. · And much more! Visit: strongtie.com/softwareandwebapplications/category Visit strongtie.com/softwareandwebapplications/category for links to our Solutions Apps and Calculators. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 17 Adhesive Anchors Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry SET-3GTM High-Strength Epoxy Adhesive SET-3G is a 1:1 ratio, two-component, high-strength, epoxy-based anchoring adhesive for cracked and uncracked concrete. SET-3G installs and performs in a variety of environmental conditions and temperature extremes. Features · Exceptional performance -- superior bond strengths permit ductile solutions in high seismic areas · Jobsite versatility -- can be specified for all base material conditions when in-service temperatures range from 40°F (40°C) to 176°F (80°C) · Two-year shelf life for unopened cartridges stored between 45°F (7°C) and 90°F (32°C) · During the installation of SET-3G, when the correct installation processes are followed, there is no performance difference between water-saturated concrete, water-filled holes, or submerged concrete · For use with potable water Cracked Concrete CODE LISTED Applications · Threaded rod anchor and rebar dowel installations in cracked and uncracked concrete · Recognized per ICC ES AC308 for post-installed rebar development and splice length design provisions · Installation in downward, horizontal and upwardly inclined (including overhead) orientations Codes Concrete -- ICC-ES ESR-4057 (including post-installed rebar connections and City of LA); FL15730. SET-3G Adhesive Masonry -- ICC-ES ESR pending. ASTM C881 and AASHTO M235 -- Types I/IV and II/V, Grade 3, Class B&C. NSF/ANSI/CAN 61 (216 in.2 / 1,000 gal.). Chemical Resistance Contact Simpson Strong-Tie for information. Installation and Application Instructions · Surfaces to receive epoxy must be clean per approved hole cleaning method. Approved for installation with multiple vacuum drill bit systems without further hole cleaning. · Base-material temperatures must be 40°F (4°C) or above at the time of installation. For best results, adhesive should be conditioned to a temperature between 70°F (21°C) and 80°F (37°C) at the time of installation. · To warm cold adhesive, store cartridges in a warm, uniformly heated area or storage container. Do not immerse cartridges in water or use microwave to facilitate warming. · Mixed material can harden in the dispensing nozzle within 30 minutes at 70°F (21°C). Note: For full installation instructions, see product packaging or visit strongtie.com/set3g. 20 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry SET-3GTM High-Strength Epoxy Adhesive SET-3G Adhesive Cartridge System Model No. Capacity (ounces) Cartridge Type Carton Quantity Dispensing Tool(s) Mixing Nozzle SET3G101 8.5 Coaxial 12 CDT10S SET3G22-N1 22 Side-by-side 10 EDT22S, EDTA22P, EMN22I EDTA22CKT SET3G56 56 Side-by-side 6 EDTA56P 1. One EMN22I mixing nozzle and one extension are supplied with each cartridge. 2. Use only Simpson Strong-Tie® mixing nozzles in accordance with Simpson Strong-Tie instructions. Modification or improper use of mixing nozzle may impair SET-3G adhesive performance. 3. Use of rodless pneumatic tools to dispense single-tube, coaxial adhesive cartridges is prohibited. 4. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available at strongtie.com. 5. Cartridge estimation guidelines are available at strongtie.com/apps. SET-3G Cure Schedule1, 2 Concrete Temperature Gel Time Cure Time (°F) (°C) (minutes) (hours) 40 4 120 192 50 10 75 72 60 16 50 48 70 21 35 24 90 32 25 24 100 38 15 24 For SI: 1°F = (°C x 9/5) + 32. 1. For water-saturated concrete, water-filled holes and submerged concrete, the cure times should be doubled. 2. For installation of anchors in concrete where the temperature is below 70°F (21°C), the adhesive must be conditioned to a minimum temperature of 70°F (21°C). S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 21 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry SET-XP® High-Strength Epoxy Adhesive SET-XP is a 1:1 ratio, two-component, high-strength, epoxy-based anchoring adhesive for anchoring and doweling in cracked and uncracked concrete and masonry applications. Features · Design flexibility -- permitted for sustained load performance at elevated temperature · Suitable for use in dry or water-saturated concrete · Two-year shelf life for unopened cartridges stored between 45°F (7°C) and 90°F (32°C) Cracked Concrete CODE LISTED Applications · Threaded rod anchoring and rebar doweling into concrete and masonry · Recognized per AC308 to be used for rebar development and splice length design provisions of ACI 318 · Installation in downward, horizontal and upwardly inclined (including overhead) orientations Codes Concrete -- ICC-ES ESR-2508 (including post-installed rebar and City of LA Report); FL15730. Masonry -- IAPMO UES ER-265 (including City of LA Report); FL16230; ICC-ES ESR pending. ASTM C881 and AASHTO M235 -- Types I/IV and II/V, Grade 3, Class C. NSF/ANSI/CAN 61 (216 in.2 / 1,000 gal.). SET-XP Adhesive Installation and Application Instructions · Surfaces to receive epoxy must be clean per approved hole cleaning method. Approved for installation with multiple vacuum drill bit systems without further hole cleaning. · Base material temperature must be 50°F (10°C) or above at the time of installation. For best results, material should be between 70°F (21°C) and 80°F (27°C) at time of application. · To warm cold material, store cartridges in a warm, uniformly heated area or storage container. Do not immerse cartridges in water or use microwave to facilitate warming. · Mixed material in nozzle can harden in 30 minutes at temperatures of 70°F (21°C). Suggested Specifications See strongtie.com for more information. 22 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry SET-XP® High-Strength Epoxy Adhesive SET-XP Cartridge System Model No. Capacity Cartridge Carton (ounces) Type Quantity Dispensing Tool(s) Mixing Nozzle SETXP101 8.5 Single 12 CDT1OS SETXP22-N1 22 Side-by-Side 10 EDT22S, EDTA22P, EDTA22CKT EMN22I SETXP56 56 Side-by-Side 6 EDTA56P 1. One EMN22I mixing nozzle and one extension are supplied with each cartridge. 2. Use only Simpson Strong-Tie® mixing nozzles in accordance with Simpson Strong-Tie instructions. Modifications or improper use of mixing nozzle may impair SET-XP adhesive performance. 3. Use of rodless pneumatic tools to dispense single-tube, coaxial adhesive cartridges is prohibited. 4. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available at strongtie.com. 5. Cartridge estimation guidelines are available at strongtie.com/apps. Cure Schedule Base Material Temperature °F °C Gel Time (minutes) 50 10 75 60 16 60 70 21 45 90 32 35 110 43 20 1. For water-saturated concrete, the cure times must be doubled. Cure Time (hours) 72 48 24 24 24 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 23 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry ET-HP® Epoxy Adhesive ET-HP is a two-component, high-solids, epoxy-based system for use as a high-strength, non-shrink anchor-grouting material. ET-HP is formulated for anchoring and doweling in cracked and uncracked concrete and masonry applications. Features · Suitable for use under static and seismic loading conditions in cracked and uncracked concrete and masonry · Suitable for use in dry or water-saturated concrete · Two-year shelf life for unopened cartridges stored between 45°F (7°C) and 90°F (32°C) Cracked Concrete CODE LISTED Applications · Threaded rod anchoring and rebar doweling into concrete and unreinforced masonry · Installation in downward, horizontal and upwardly inclined (including overhead) orientations Codes Concrete -- ICC-ES ESR-3372 (including City of LA); FL15730. Masonry -- IAPMO UES ER-241 (including Florida Supplement); FL16230. Unreinforced Masonry (URM) -- ICC-ES ESR-3638. ASTM C881 and AASHTO M235 -- Types I/IV, II/V, Class B and C, Grade 3. Installation and Application Instructions · Surfaces to receive epoxy must be clean per approved hole cleaning method. · Base material temperature must be 50°F (10°C) or above at the time of installation. For best results, material should be between 70°F (21°C) and 80°F (27°C) at time of application. · To warm cold material, store cartridges in a warm, uniformly heated area or storage container. Do not immerse cartridges in water or use microwave to facilitate warming. · Mixed material in nozzle can harden in 15 minutes at temperatures of 70°F (21°C). ET-HP Adhesive Suggested Specifications See strongtie.com for more information. 24 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry ET-HP® Epoxy Adhesive ET-HP Package Systems Model No. Capacity (ounces) Package Type Carton Dispensing Quantity Tools Mixing Nozzle ET-HP22-N1 22 Side-by-side EDT22S, 10 EDTA22P, EMN22I EDTA22CKT 1. One EMN22I mixing nozzle and one extension are supplied with each cartridge. 2. Use only Simpson Strong-Tie® mixing nozzles in accordance with Simpson Strong-Tie instructions. Modifications or improper use of mixing nozzle may impair ET-HP adhesive performance. 3. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available at strongtie.com. 4. Cartridge estimation guidelines are available at strongtie.com/apps. Cure Schedule Base Material Temperature °F °C Gel Time (minutes) 50 10 45 60 16 30 80 27 20 100 38 15 1. For water-saturated concrete, the cure times must be doubled. Cure Time1 (hours) 72 24 24 24 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 25 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry AT-XP® High-Strength Acrylic Adhesive AT-XP is a 10:1 ratio, two-component, high-strength acrylic-based anchoring adhesive for use in threaded rod and rebar into cracked and uncracked concrete and masonry under a wide range of conditions. AT-XP adhesive dispenses easily in cold or warm environments and in below-freezing temperatures with no need to warm the cartridge. Features · Suitable for use in dry or water-saturated concrete. · One-year shelf life for unopened cartridges (13 oz. and 30 oz.) when stored between 14°F (10°C) and 80°F (27°C). Eighteen-month shelf life for unopened cartridges (10 oz.) when stored between 14°F (10°C) and 80°F (27°C). · Cures in substrate temperatures as low as 14°F in 24 hours or less. Cures in 30 minutes at 86°F. Cracked Concrete CODE LISTED Applications · Threaded rod anchoring and rebar doweling into concrete and masonry · Installation in downward, horizontal and upwardly inclined (including overhead) orientations Codes Concrete -- IAPMO UES ER-263 (including City of LA); FL16230. Masonry -- IAPMO UES ER-281 (including City of LA and Florida Building Code Supplement); FL16230. ASTM C881 and AASHTO M235 -- Types I/IV, Grade 3, Class A, B, and C except AT-XP is not an epoxy. NSF/ANSI/CAN 61 (43.2 in.2 / 1,000 gal.). Installation and Application Instructions · Surfaces to receive adhesive must be clean per approved hole cleaning method. Approved for installation with vacuum drill bit system without further hole cleaning. AT-XP Adhesive · Base material temperature must be 14°F (10°C) or above at the time of installation. For best results, material should be between 14°F (10°C) and 80°F (27°C) at time of application. · To warm cold material, store cartridges in a warm, uniformly heated area or storage container. Do not immerse cartridges in water or use microwave to facilitate warming. · Mixed material in nozzle can harden in 34 minutes at temperatures of 70°F (21°C). Suggested Specifications See strongtie.com for more information. 26 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry AT-XP® High-Strength Acrylic Adhesive AT-XP Adhesive Cartridge System Model No. Capacity ounces (cubic in.) Cartridge Type Carton Qty. AT-XP101 9.4 (16.9) Coaxial 6 Dispensing Tool CDT10S Mixing Nozzle AT-XP131 12.5 (22.5) Side-by-side 10 ADT813S AMN19Q ADT30S AT-XP301 30 Side-by-side 5 ADTA30P or (54) ADTA30CKT 1. One AMN19Q mixing nozzle with integrated extension is supplied with each cartridge. 2. Use only Simpson Strong-Tie® mixing nozzles in accordance with Simpson Strong-Tie instructions. Modifications or improper use of mixing nozzle may impair AT-XP adhesive performance. 3. Use of rodless pneumatic tools to dispense single-tube, coaxial adhesive cartridges in prohibited. 4. Detailed information on dispensing tools, mixing nozzles and other adhesive accessories is available at strongtie.com. 5. Cartridge estimation guidelines are available at strongtie.com/apps. Cure Schedule Base Material Temperature °F °C Gel Time (minutes) 14 -10 30 32 0 15 50 10 7 68 20 4 86 30 1 1/2 100 38 1 1. For water-saturated concrete, the cure times must be doubled. Cure Time (hours) 24 8 3 1 30 min. 20 min. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 27 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Adhesive Anchors Adhesive Dispensing Tools Our heavy-duty tools are designed to work with our cartridges for trouble-free dispensing. Each manual tool provides a 26:1 drive mechanism for easier dispensing of high-viscosity adhesive. CDT10S Manual Dispensing Tool for Single Cartridge Adhesives The CDT10S features a steel carriage for ultimate durability and is engineered for continuous, high-volume use, as well as double-gripping plates that help extend tool life. EDT22S Manual Dispensing Tool for 22 oz. Adhesive Cartridges The EDT22S epoxy adhesive tool features a steel carriage and is engineered for high-volume, continuous use. The tool can be easily converted (conversion parts included) from dispensing a 22 oz., 1:1 ratio cartridge to a 16.5 oz., 2:1 ratio cartridge. CDT10S EDT22S EDTA22CKT Battery-Powered Dispensing Tool for 22 oz. Cartridges The EDTA22CKT offers power dispensing of 22 oz., 1:1 ratio, dual-cartridge adhesives without the need for a hose or compressor. The 18V lithium-ion battery is 50% lighter than NiCad and offers 40% longer run time and 30-minute recharging. Tool converts to dispense 16.5 oz., 2:1 ratio dual-cartridge adhesives (conversion parts included). The EDTA22CKT comes with the dispensing tool, two 18V lithium-ion battery packs and a charger. EDTA22CKT Tool and Charger EDTA22P Pneumatic Dispensing Tool for 22 oz. Cartridges The EDTA22P tool features an optional suitcase handle adapter for the ultimate in tool configuration and dispensing convenience, enabling easier and time-saving groundlevel doweling. The heavy-duty tool comes with a custom, blow-molded plastic carrying case. EDTA22P EDTA56P Pneumatic Dispensing Tool for 56 oz. Cartridges The EDTA56P tool features an optional suitcase handle adapter for the ultimate in tool configuration and dispensing convenience, enabling easier and time-saving ground-level doweling. The heavy-duty tool comes with a custom, blow-molded plastic carrying case. Description Premium tool for single-tube cartridges Manual tool for 22 oz. cartridges Battery-powered tool for 22 oz. cartridges Pneumatic tool for 22 oz. cartridges1,2 Pneumatic tool for 56 oz. cartridges1,2 Model No. CDT10S EDT22S EDTA22CKT EDTA22P EDTA56P EDTA56P 1. Air supply attachment is 1/4 18 NPT (male) thread. 2. Recommended operating air pressure is between 80 and 100 psi. Maintenance tips, troubleshooting and repair parts schematics available at strongtie.com. 28 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Adhesive Anchors ADT813S Manual Dispensing Tool for 12.5 oz. Cartridges The ADT813S features a steel carriage for ultimate durability. The ADT813S also features double-gripping plates that help extend tool life. ADT30S Manual Dispensing Tool for 30 oz. Adhesive Cartridges The ADT30S features a steel carriage for ultimate durability and is engineered for continuous, high-volume use, as well as double-gripping plates that help extend tool life. The tool can be easily converted from 30 oz. 10:1 cartridges to 32 oz. 2:1 cartridges (conversion parts included). ADTA30CKT Battery-Powered Dispensing Tool for 30 oz. Cartridges The ADTA30CKT offers power dispensing of 30 oz., 10:1 ratio, dual-cartridge adhesives without the need for a hose or compressor. The tool features dosage and rate control for maximum efficiency on the job. The 18V lithium-ion battery is 50% lighter than NiCad and offers 40% longer run time. Recharging takes only 30 minutes. The ADTA30CKT comes with the dispensing tool, two 18V Lithium-ion battery packs a charger and parts to easily convert from 30 oz. 10:1 cartridges to 32 oz. 2:1 cartridges. ADTA30P Pneumatic Dispensing Tool for 30 oz. Cartridges The ADTA30P tool features an optional suitcase handle adapter for flexible tool configuration and dispensing convenience. The suitcase option enables easier and time-saving ground-level doweling. The heavy-duty tool comes with a custom, blow-molded plastic carrying case. The tool can be easily converted from 30 oz. 10:1 cartridges to 32 oz. 2:1 cartridges (conversion parts included). ADT813S ADT30S ADTA30CKT ADTA30P Description Manual tool for 12.5 oz. cartridges Manual tool for 30 oz. 10:1 cartridges and 32 oz. 2:1 cartridges Battery-powered tool for 30 oz. 10:1 cartridges and 32 oz. 2:1 cartridges Pneumatic tool for 30 oz. cartridges1,2 1. Air supply attachment is 1/4-18 NPT (male) thread. 2. Recommended operating air pressure is between 80 and 120 psi. Model No. ADT813S ADT30S ADTA30CKT ADTA30P Maintenance tips, troubleshooting and repair parts schematics available at strongtie.com. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 29 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Nozzle Accessories EMN22i An 18-element mixing nozzle with integrated nut for use with 10 oz., 22 oz. and 56 oz. epoxy adhesive cartridges. Model No. Option EMN22i Package Quantity Carton Quantity EMN22I Single mixing nozzle for epoxy products. 1 12 EMN22I-RP10 Ten mixing nozzles for epoxy products. 10 3 EMN22I-RP5 Five mixing nozzles for epoxy products. 5 6 EMN22IB Five hundred mixing nozzles for epoxy products. 500 500 EMN50 An 18-element high-volume mixing nozzle with integrated nut for use with 22 oz. and 56 oz. epoxy adhesive cartridges. EMN50 Model No. Option EMN50 High-volume nozzle for 22 oz. and 56 oz. cartridges (separate retaining nut not required), 17" long, major diameter 7/8". Package Quantity 10 AMN19Q A 19-element high-strength static mixing nozzle with integrated nut for use with all acrylic adhesive products. Model No. Option AMN19Q-RP5 Five mixing nozzles for AT-XP® product. AMN19Q Package Quantity 5 Carton Quantity 10 30 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Hole-Cleaning Brushes Brushes are used for cleaning drilled holes prior to adhesive installation. Note: The standard hole-cleaning method (blow-brush-blow) can be avoided by using an approved vacuum drill bit system. See product pages on strongtie.com for approved vacuum drill bit systems. Wire Brush -- Standard (For use with SET-3G) Model No. Hole Diameter Anchor Diameter (in.) (in.) Rebar Size Usable Length (in.) ETB43S 7/16 3/8 -- 5 ETB50S 1/2 -- #3 5 ETB56S 9/16 1/2 -- 5 ETB62S 5/8 -- #4 5 ETB68S 11/16 5/8 -- 5 ETB75S 3/4 -- #5 5 ETB87S 7/8 3/4 #6 5 ETB100S 1 7/8 #7 5 ETB112S 1 1/8 1 #8 5 ETB137S 1 3/8 1 1/4 #10 5 ETBS-TH T-handle 8 1/2 ETBS-EXT Extension 11 1/2 1. T-handle is required for use with all sizes of standard wire brush. 2. To obtain total usable length, add the usable length for each part used. Carton Quantity 25 25 25 25 25 25 25 25 25 25 25 25 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 31 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Hole-Cleaning Brushes (cont.) Nylon Brush -- Standard (For use with SET-XP®, AT-XP® and ET-HP®) Model No. ETB4 Hole Diameter (in.) 3/8 7/16 Anchor Diameter (in.) 1/4 5/16 Rebar Size -- Usable Length (in.) 7 Carton Quantity 24 ETB6 1/2 3/4 3/8 5/8 #3 #5 15 24 ETB8 13/16 7/8 3/4 #6 15 24 ETB8L 13/16 7/8 3/4 #6 23 24 ETB10 1 1 1/8 7/8 1 #7 #8 28 24 ETB12 1 3/16 1 3/8 1 1/4 #10 33 24 1. All standard nylon brushes are one-piece which includes a twisted wire handle. Nylon Brush -- Rebar (For use with SET-XP and SET-3GTM) (Note: Brushes are only applicable for SET-3G when used for post-installed rebar connections.) Model No. Hole Diameter (in.) Rebar Size Usable Length (in.) ETB6R 1/2 3/4 #3 #5 6 ETB8R 7/8 #6 6 ETB10R 1 1 1/8 #7 #8 8 ETB12R 1 3/8 #10 8 ETB14R 1 3/4 #11 7 ETBR-EXT T-handle and extension 35 1/4 1. ETBR-EXT is required for use with all sizes of rebar nylon brushes. 2. To obtain total usable length, add the usable length for each part used. 3. Brushes are used when rebar is installed to replace cast-in-place bar for lap splices and development length. Carton Quantity 25 25 25 25 25 25 32 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Piston Plug Delivery System The Simpson Strong-Tie® Piston Plug Delivery System for adhesives offers you an easy-to-use, reliable and less time-consuming means to dispense adhesive into drilled holes for threaded rod and rebar dowel installations in overhead, upwardly inclined and horizontal orientations. The matched tolerance design between the piston plug and drilled hole virtually eliminates the formation of voids and air pockets during adhesive dispensing. The Piston Plug Delivery System consists of three components: piston plug, flexible extension tubing, and adhesive retaining cap. Features · Designed for dispensing adhesive into drilled holes in overhead, upwardly inclined and horizontal orientations, as well as deep embedments · Suitable for use with all Simpson Strong-Tie anchoring adhesives · Adhesive piston plugs are sized to fit each drilled hole diameter · Model number is embossed on each adhesive piston plug for identification · A barbed end provides a reliable connection to the flexible extension tubing · Flexible extension tubing is available in 25-foot-long rolls to be cut to required lengths Use the piston plug delivery system with all Simpson Strong-Tie adhesive products: SET-3GTM SET-XP® AT-XP® S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. ET-HP® 33 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Piston Plug Delivery System (cont.) Piston Plugs Model No. Hole Size (in.) Pkg. Quantity Carton Quantity* PP56-RP10 9/16 PP62-RP10 5/8 PP68-RP10 11/16 PP75-RP10 3/4 PP81-RP10 13/16 PP87-RP10 7/8 PP100-RP10 1 PP112-RP10 1 1/8 PP137-RP10 1 3/8 PP175-RP10 1 3/4 *Product is sold by package. 10 10 packs of 10 10 10 packs of 10 10 10 packs of 10 10 10 packs of 10 10 10 packs of 10 10 10 packs of 10 10 10 packs of 10 10 10 packs of 10 10 10 packs of 10 10 10 packs of 10 Piston Plugs Tubing Model No. Description Package Quantity PPFT25 Piston Plug Flexible Extension Tubing -- 25 ft. roll 1 1. Tubing dimensions: inner diameter 3/8", outer diameter 1/2". Piston Plug Flexible Extension Tubing 34 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Adhesive Retaining Caps Adhesive retaining caps make overhead and horizontal installation easier by preventing the adhesive from running out of the hole. They also center the rod in the hole, making them ideal for applications where precise anchor placement is required. It may be necessary to provide support for the anchor during cure time. Adhesive retaining caps are not designed to support the weight of the anchor in overhead installations. Adhesive retaining caps should be used for horizontal and overhead adhesive installations. ARCs may be used in conjunction with the Piston Plug Delivery system. Adhesive Retaining Caps Retaining Caps Model No. Hole Anchor Size Dia. (in.) (in.) ARC37A-RP25 7/16 3/8 ARC37-RP25 1/2 3/8 ARC50A-RP25 9/16 1/2 ARC50-RP25 5/8 1/2 ARC62A-RP25 11/16 5/8 ARC62-RP25 3/4 5/8 ARC75A-RP25 13/16 3/4 ARC75-RP25 7/8 3/4 ARC87-RP25 1 7/8 ARC100A-RP25 11/16 1 ARC100-RP25 1 1/8 1 ARC125-RP25 1 3/8 1 1/4 ARC137-RP25 13/4 -- *Product is sold by package. Rebar Size #3 #4 #5 #6 #7 #8 #10 #11 Cap Depth (in.) 7/16 7/16 1/2 1/2 9/16 9/16 9/16 9/16 11/16 11/16 11/16 7/8 11/16 Package Quantity 25 25 25 25 25 25 25 25 25 25 25 25 25 Carton Quantity* (each) 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 8 packs of 25 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 35 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Opti-Mesh Adhesive-Anchoring Screen Tubes Screen tubes are vital to the performance of adhesive anchors in base materials that are hollow or contain voids, such as hollow block and brick. The Simpson StrongTie® OptiMesh screen tube with woven mesh insert provides the advantages of a plastic screen tube while providing superior performance to steel screen tubes and competitive plastic screen tubes. Material: Plastic Caution: Screen tubes are designed for specific Simpson Strong-Tie anchoring adhesives (see below). EWSP Epoxy Adhesive Screen Tube (mesh is black) For use with SET-XP US Patent: 6,837,018 Integral Cap: Serves to center and secure the rod in the screen tube, while displaying important information such as rod diameter, drill bit diameter and the Simpson StrongTie "" symbol for easy inspection after installation. The cap also prevents adhesive from running out the front of the screen tube. Flanges: Prevents the screen tube from slipping into over-drilled holes. Open-Mesh Collar: This section of larger mesh allows extra adhesive to flow out the screen tube behind the face shell of hollow block applications. The extra "collar" of adhesive increases bearing area and results in higher load capacities in hollow concrete block. Color-Coded, Formula-Specific Mesh: The openings between the woven mesh screen tube strands are sized to allow only the right amount of adhesive to flow through the screen tube to bond with the base material while the balance remains in the screen to bond the rod. 3GWSP Adhesive Screen Tube (gray frame with gray mesh) For use with SET-3GTM 36 The integral cap centers the rod and displays drill bit and rod diameter. AWSP Acrylic Adhesive Screen Tube (mesh is white) For use with AT-XP S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Screen Tubes -- Plastic For Rod Diameter (in.) Hole Size (in.) Length (in.) EWSP Model No. for SET-XP® AWSP Model No. for AT-XP® 3GWSP Model No. for SET-3GTM Carton Quantity 3 1/2 EWS373P AWS373P 3GWS373P 150 3/8 9/16 6 EWS376P AWS376P 3GWS376P 150 10 EWS3710P AWS3710P 3GWS3710P 100 3 1/2 EWS503P AWS503P 3GWS503P 100 1/2 3/4 6 EWS506P AWS506P 3GWS506P 100 10 EWS5010P AWS5010P 3GWS5010P 50 3 1/2 EWS623P AWS623P 3GWS623P 50 5/8 7/8 6 EWS626P AWS626P 3GWS626P 50 10 EWS6210P AWS6210P 3GWS6210P 25 8 EWS758P AWS758P 3GWS758P 25 3/4 1 13 EWS7513P AWS7513P 3GWS7513P 25 Specially sized holes in Opti-Mesh screens allow for adhesive to seep out at the appropriate location at the hollow portion of the CMU to create a better bond to the face shell. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 37 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Steel Adhesive-Anchoring Screen Tubes Screen tubes are used in hollow base material applications to contain adhesive around the anchor and prevent it from running into voids. Simpson StrongTie® screen tubes are specifically designed to work with AT-XP® and ET-HP® adhesives in order to precisely control the amount of adhesive that passes through the mesh. This results in thorough coating and bonding of the rod to the screen tube and base material. Order screen tubes based upon rod diameter and adhesive type. The actual outside diameter of the screen tube is larger than the rod diameter. Material: ATS screen tubes: 50 mesh stainless steel ETS screen tubes: 60 mesh carbon steel Caution: Screen tubes are designed for a specific adhesive type. ETS screen tubes must be used with ET-HP formulations and ATS screen tubes must be used with AT-XP. Screen Tube Screen tubes are for use in hollow CMU, hollow brick and unreinforced masonry applications. 38 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Screen Tubes For Rod Diameter (in.) Hole Size (in.) ATS Stainless Steel Screen Tubes for AT-XP Actual Screen Size O.D./Length (in.) Model No. ETS Carbon Steel Screen Tubes for ET-HP (SET-XP® 3/4" Rod Sizes) Actual Screen Size O.D./Length (in.) Model No. Carton Quantity -- 3/8 9/16 -- -- 15/32 x 6 ETS376 150 -- 15/32 x 10 ETS3710 100 -- 1/2 11/16 -- -- 19/32 x 6 ETS506 100 -- 19/32 x 10 ETS5010 50 -- -- 25/32 x 6 ETS626 50 5/8 7/8 -- -- 25/32 x 10 ETS6210 25 -- -- 25/32 x 13 ETS6213 25 31/32 x 8 ATS758 31/32 x 8 ETS758 25 31/32 x 13 ATS7513 31/32 x 13 ETS7513 25 3/4 1 31/32 x 17 ATS7517 31/32 x 17 ETS7517 25 -- -- 31/32 x 21 ETS7521 25 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 39 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories Retrofit Bolts RFBs are pre-cut threaded rod, supplied with nut and washer. Each end of the threaded rod is stamped with the rod length in inches and our No-Equal® symbol for easy identification after installation. Material: ASTM F1554 Grade 36, A36 or A307 min fy = 36 ksi, min Fu = 58 ksi and not to exceed 80 ksi Coating: Zinc-plated, hot-dip galvanized RFB Retrofit Bolts Size. (in.) Zinc-Plated Model No. Hot-Dip Galvanized Model No. Carton Quantity Hot-Dip Galvanized Retail Model No.* Package Quantity Carton Quantity 3/8 x 4 RFB#3x4 RFB#3x4HDG 50 -- -- -- 3/8 x 6 RFB#3x6 -- 50 -- -- -- 3/8 x 8 RFB#3x8 -- 50 -- -- -- 1/2 x 4 RFB#4x4 -- 50 -- -- -- 1/2 x 5 RFB#4x5 RFB#4x5HDG 50 RFB#4x5HDGP2 2 5 packs of 2 1/2 x 6 RFB#4x6 RFB#4x6HDG 50 -- -- -- 1/2 x 7 RFB#4x7 RFB#4x7HDG 50 -- -- -- 1/2 x 8 RFB#4x8 RFB#4x8HDG 50 RFB#4x8HDGP2 2 5 packs of 2 1/2 x 10 RFB#4x10 RFB#4x10HDG 25 -- -- -- 5/8 x 5 RFB#5x5 RFB#5x5HDG 50 RFB#5x5HDGP2 2 5 packs of 2 5/8 x 8 RFB#5x8 RFB#5x8HDG 50 RFB#5x8HDGP2 2 5 packs of 2 5/8 x 10 RFB#5x10 RFB#5x10HDG 50 -- -- -- 5/8 x 12 -- RFB#5x12HDG 25 RFB#5x12HDGP2 2 5 packs of 2 5/8 x 16 RFB#5x16 RFB#5x16HDG 25 RFB#5x16HDGP2 2 5 packs of 2 3/4 x 6 RFB#6x6 -- 50 -- -- -- 3/4 x 8 RFB#6x8 RFB#6x8HDG 50 -- -- -- 3/4 x 101/2 RFB#6x10.5 RFB#6x10.5HDG 25 -- -- -- *Retail products ("P2") packaged in a polybag. 40 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Accessories All Thread Rod ATRs are pre-cut threaded rod for use with Simpson Strong-Tie® adhesives. Material: ASTM F1554 Grade 36, A36 or A307 min fy = 36 ksi, min Fu = 58 ksi and not to exceed 80 ksi Coating: Uncoated, zinc-plated; hot-dip galvanized Description Dia. x Length (in.) 3/8 x 12 3/8 x 24 3/8 x 36 1/2 x 12 1/2 x 18 1/2 x 24 1/2 x 36 5/8 x 12 5/8 x 18 5/8 x 24 5/8 x 30 5/8 x 36 3/4 x 12 3/4 x 18 3/4 x 24 3/4 x 36 7/8 x 12 7/8 x 18 7/8 x 20 7/8 x 24 7/8 x 26 7/8 x 36 1 x 12 1 x 18 1 x 24 1 x 36 ATR All Thread Rod Uncoated Model No. ATR3/8x12 ATR3/8x24 ATR3/8x36 ATR1/ 2x12 ATR1/ 2x18 ATR1/ 2x24 ATR1/ 2x36 ATR5/8x12 ATR5/8x18 ATR5/8x24 ATR5/8x30 ATR5/8x36 ATR3/4x12 ATR3/4x18 ATR3/4x24 ATR3/4x36 ATR7/8x12 ATR7/8x18 ATR7/8x20 ATR7/8x24 ATR7/8x26 ATR7/8x36 ATR1x12 ATR1x18 ATR1x24 ATR1x36 Zinc-Plated Model No. -- -- -- ATR1/ 2x12ZP -- ATR1/ 2x24ZP ATR1/ 2x36ZP ATR5/8x12ZP ATR5/8x18ZP ATR5/8x24ZP -- ATR5/8x36ZP ATR3/4x12ZP ATR3/4x18ZP ATR3/4x24ZP ATR3/4x36ZP ATR7/8x12ZP ATR7/8x18ZP -- ATR7/8x24ZP -- ATR7/8x36ZP ATR1x12ZP ATR1x18ZP ATR1x24ZP ATR1x36ZP Hot-Dip Galvanized Model No. -- -- ATR3/8x36HDG ATR1/ 2x12HDG ATR1/ 2x18HDG ATR1/ 2x24HDG ATR1/ 2x36HDG ATR5/8x12HDG ATR5/8x18HDG ATR5/8x24HDG -- ATR5/8x36HDG ATR3/4x12HDG ATR3/4x18HDG ATR3/4x24HDG ATR3/4x36HDG ATR7/8x12HDG ATR7/8x18HDG -- ATR7/8x24HDG -- ATR7/8x36HDG ATR1x12HDG ATR1x18HDG ATR1x24HDG ATR1x36HDG Carton Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 41 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Anchoring Installation Instructions NOTE: Always check expiration date on product label. Do not use expired product. WARNING: When drilling and cleaning hole, use eye and lung protection. When installing adhesive, use eye and skin protection. 1A Hole Preparation -- Horizontal, Vertical and Overhead Applications (SET-3GTM for anchor installation) 1. Drill. Drill hole to specified diameter and depth. 2 seconds (min.) 80 psi min. 2. Blow. Remove dust from hole with oil-free compressed air for a minimum of two seconds. Compressed air nozzle must reach the bottom of the hole. 2 cycles (min.) 3. Brush. Clean with a steel wire brush for a minimum of two cycles. Brush should provide resistance to insertion. If no resistance is felt, the brush is worn and must be replaced. Visit strongtie.com for proper brush part number. 2 seconds (min.) 80 psi min. 4. Blow. Remove dust from hole with oil-free compressed air for a minimum of two seconds. Compressed air nozzle must reach the bottom of the hole. Hole Preparation -- Horizontal, Vertical and Overhead Applications (SET-XP®, AT-XP®, ET-HP®) and (SET-3G only for post-installed rebar connections) 1. Drill. Drill hole to specified diameter and depth. 4 seconds (min.) 80 psi min. 2. Blow. Remove dust from hole with oil-free compressed air for a minimum of four seconds. Compressed air nozzle must reach the bottom of the hole. 4 cycles (min.) 3. Brush. Clean with a nylon brush for a minimum of four cycles. Brush should provide resistance to insertion. If no resistance is felt, the brush is worn and must be replaced. Visit strongtie.com for proper brush part number. 4 seconds (min.) 80 psi min. 4. Blow. Remove dust from hole with oil-free compressed air for a minimum of four seconds. Compressed air nozzle must reach the bottom of the hole. 42 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Anchoring Installation Instructions 1B Hole Preparation Vacuum Drill Bit System* -- Horizontal, Vertical and Overhead Applications 1. Drill. Drill hole to specified diameter and depth using the accepted vacuum drill bit system.* Approved for installation with multiple vacuum drill bit systems.* * Note: Visit strongtie.com for tested and accepted hollow carbide drill bit and vacuum dust extraction systems. 1C Hole Preparation -- Submerged Applications (SET-3GTM only) 1. Drill. Drill hole to specified diameter and depth. 2. Flush. 2x Remove slurry from hole by flushing hole twice with water until water runs clear. 2 cycles (min.) 3. Brush. Clean with a steel wire brush for a minimum of two cycles. Brush should provide resistance to insertion. If no resistance is felt, the brush is worn and must be replaced. 4. Flush. 2x Remove slurry from hole by flushing hole twice with water until water runs clear. Visit strongtie.com for proper brush part number. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 43 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Anchoring Installation Instructions 2 Cartridge Preparation 1. Check. Check expiration date on product label. Product is usable until end of printed expiration month. Do not use expired product. 2. Open. Open cartridge per package instructions. 3. Attach. Attach proper Simpson Strong-Tie® nozzle and extension to cartridge. Do not modify nozzle. 4. Insert. Insert cartridge into dispensing tool. 5. Dispense. Dispense adhesive to the side until properly mixed (uniform color). 44 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Anchoring Installation Instructions 3A Filling the Hole -- Vertical Anchorage Prepare the hole per "Hole Preparation" instructions on product label. Dry and Damp Holes: 1. Fill. Fill hole 1/2 to 2/3 full, starting from bottom of hole to prevent air pockets. Withdraw nozzle as hole fills up. Threaded rod or rebar 2. Insert. Insert clean, oil-free anchor, (marked with the required embedment depth), turning slowly until the anchor contacts the bottom of the hole. 3. Do not disturb. Do not disturb load or torque anchor until fully cured. Water-Filled Holes: 1. Fill. Fill hole completely full, starting from bottom of hole to prevent water pockets. Withdraw nozzle as hole fills up. Threaded rod or rebar 2. Insert. Insert clean, oil-free anchor, (marked with the required embedment depth), turning slowly until the anchor contacts the bottom of the hole. 3. Do not disturb. Do not disturb load or torque anchor until fully cured. Note: Nozzle extensions may be needed for deep holes. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 45 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Anchoring Installation Instructions 3B Filling the Hole -- Horizontal and Overhead Anchorage Prepare the hole per "Hole Preparation" instructions on product label. Adhesive Anchors ! Step 1 · Attach the piston plug to one end of the flexible tubing (PPFT25). · Cut tubing to the length needed for the application, mark tubing as noted below and attach other end of tubing to the mixing nozzle. ½ to to½ embedment · If using a pneumatic dispensing tool, regulate air pressure to 80100 psi. Step 2 · Insert the piston plug to the back of the drilled hole ! ! and dispense adhesive. ! ! to½ t to½ t ! ½ to to½ embedment ! ! Step 4 · Install the appropriate Simpson Strong-Tie® adhesive retaining cap. Step 3 · Fill the hole 1/2 to 2/3 full. Note: As adhesive is dispensed into the drilled hole, the piston plug will slowly displace out of the hole due to back pressure, preventing air gaps. Step 5 · Place either threaded rod or rebar through the adhesive retaining cap and into adhesive filled hole. · Turn rod/rebar (marked with the required embedment depth) slowly until the insert bottoms out. · Do not disturb load or torque anchor until fully cured. For overhead installations, the anchor must be secured from movement during the cure time (e.g., wedges or other restraint methods). 46 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Anchoring Installation Instructions 3C Filling the Hole -- Submerged Anchorage (SET-3GTM only) Prepare the hole per "Hole Preparation" instructions on product label. Step 1 · Attach the piston plug to one end of the flexible tubing (PPFT25). · Cut tubing to the length needed for the application, mark tubing as noted below and attach other end of tubing to the mixing nozzle. · If using a pneumatic dispensing tool, regulate air pressure to 80100 psi. ! ½ to to½ embedment ! Embedment Step 2 · Insert the piston plug to the back of the drilled hole and dispense adhesive. ! Step 3 · Fill the hole completely full. Note: As adhesive is dispensed into the drilled hole, the piston plug will slowly displace out of the hole due to back pressure, preventing air gaps. Step 4 · Install the appropriate Simpson Strong-Tie adhesive retaining cap. Step 5 · Place either threaded rod or rebar through the adhesive retaining cap and into adhesive filled hole. · Turn rod/rebar (marked with the required embedment depth) slowly until the insert bottoms out. · Do not disturb load or torque anchor until fully cured. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 47 Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Anchoring Installation Instructions FOR HOLLOW BASE MATERIALS 3D Filling the Hole -- When Anchoring with Screens: For SET-3GTM, SET-XP® and AT-XP® Adhesives Prepare the hole per instructions on "Hole Preparation." 1. Fill. Fill screen completely. Fill from the bottom of the screen and withdraw the nozzle as the screen fills to prevent air pockets. (Close integral cap after filling.) 2. Insert. Insert adhesive-filled screen into hole. 3. Insert. Insert clean, oil-free anchor, turning slowly until the anchor contacts the bottom of the screen. 4. Do not disturb. Do not disturb anchor until fully cured. (See cure schedule for specific adhesive.) FOR UNREINFORCED BRICK MASONRY 1A Hole Preparation -- For Configurations A (Horizontal) and B (22 1/2° Downward) Installations with a Carbide-Tipped Drill Bit. 4 seconds (min.) 1. Drill. Drill 1"-diameter hole to specified depth with a carbide-tipped drill bit, using rotation only mode. For Configurations A, drill 8" deep. For Configuration B, drill to within 1" of the opposite side of wall (minimum 13" deep). 80 psi min. 2. Blow. Remove dust from hole with oil-free compressed air for a minimum of four seconds. Compressed air nozzle MUST reach the bottom of the hole. 48 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Adhesive Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Adhesive Anchoring Installation Instructions FOR UNREINFORCED BRICK MASONRY (cont.) 4 cycles (min.) 4 seconds (min.) 3. Brush. Clean with a nylon brush for a minimum of four cycles. Brush MUST reach the bottom of the hole. Brush should provide resistance to insertion. If no resistance is felt, the brush is worn and must be replaced. 80 psi min. 4. Blow. Remove dust from hole with oil-free compressed air for a minimum of four seconds. Compressed air nozzle MUST reach the bottom of the hole. 2 Cartridge Preparation Reference p. 44 for cartridge preparation. 3 Filling the Hole -- For Configurations A (Horizontal) and B (221/2º Downward) Installations. 1. Fill. Fill screen completely. Fill from the bottom of the screen and withdraw the nozzle as the screen fills to prevent air pockets. 2. Insert. Insert adhesive filled screen into hole. 3. Insert. Insert clean, oil-free anchor, turning slowly until the anchor contacts the bottom of the screen. 4. Do not disturb. Do not disturb anchor until fully cured. (See cure schedule for specific adhesive.) Note: Steel wire mesh screens may be used for Configurations A and B. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 49 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Heavy-Duty Screw Anchor Mechanical Anchors A high-strength screw anchor for use in cracked and uncracked concrete, as well as uncracked masonry. The Titen HD offers low installation torque and outstanding performance. Suitable in dry, interior, non-corrosive environments or temporary outdoor applications. Features · Qualified for static and seismic loading conditions · Thread design undercuts to efficiently transfer the load to the base material · Standard fractional sizes · Specialized heat-treating process creates tip hardness for better cutting without compromising the ductility · No special drill bit required -- designed to install using standard-sized ANSI tolerance drill bits · Hex-washer head requires no separate washer, unless required by code, and provides a clean installed appearance · Removable -- ideal for temporary anchoring (e.g., formwork, bracing) or applications where fixtures may need to be moved · Reuse of the anchor will not achieve listed loads and is not recommended Codes: ICC-ES ESR-2713 (concrete); ICC-ES ESR-1056 (masonry); City of LA Supplement within ESR-2713 (concrete); City of LA Supplement within ESR-1056 (masonry); Florida FL15730 (concrete and masonry); FM 3017082, 3035761 and 3043442; multiple DOT listings Material: Carbon steel Coating: Zinc plated or mechanically galvanized. Not recommended for permanent exterior use or highly corrosive environments. Installation Holes in metal fixtures to be mounted should match the diameter specified in the table on p. 53. Use a Titen HD screw anchor one time only -- installing the anchor multiple times may result in excessive thread wear and reduce load capacity. Do not use impact wrenches to install into hollow CMU. Caution: Oversized holes in base material will reduce or eliminate the mechanical interlock of the threads with the base material and reduce the anchor's load capacity. 1. Drill a hole in the base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to the specified embedment depth plus minimum hole depth overall (see table on p. 53) to allow the thread tapping dust to settle, and blow it clean using compressed air. (Overhead installations need not be blown clean.) Alternatively, drill the hole deep enough to accommodate embedment depth and the dust from drilling and tapping. 2. Insert the anchor through the fixture and into the hole. 3. Tighten the anchor into the base material until the hex-washer head contacts the fixture. Cracked Concrete CODE LISTED Titen HD Screw Anchor Serrated teeth on the tip of the Titen HD screw anchor facilitate cutting and reduce installation torque. 52 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Heavy-Duty Screw Anchor Installation Sequence Mechanical Anchors Additional Installation Information for Structural Steel Titen HD Diameter (in.) Wrench Size (in.) Recommended Steel Fixture Hole Size (in.) Minimum Hole Depth Overdrill (in.) 1/4 3/8 3/8 to 7/16 1/8 3/8 9/16 1/2 to 9/16 1/4 1/2 3/4 5/8 to 11/16 1/2 5/8 15/16 3/4 to 13/16 1/2 3/4 1 1/8 7/8 to 15/16 1/2 Suggested fixture hole sizes are for structural steel thicker than 12 gauge only. Larger holes are not required for wood or cold-formed steel members. Titen HD Anchor Product Data -- Mechanically Galvanized Size (in.) Model No. Thread Length (in.) Drill Bit Diameter (in.) Wrench Size (in.) Quantity Box Carton 3/8 x 3 THD37300HMG 2 1/2 50 200 3/8 x 4 THD37400HMG 3 1/2 50 200 3/8 9/16 3/8 x 5 THD37500HMG 4 1/2 50 100 3/8 x 6 THD37600HMG 5 1/2 50 100 1/2 x 4 THD50400HMG 3 1/2 20 80 1/2 x 5 THD50500HMG 4 1/2 20 80 1/2 x 6 THD50600HMG 5 1/2 20 80 1/2 3/4 1/2 x 61/2 THD50612HMG 5 1/2 20 40 1/2 x 8 THD50800HMG 5 1/2 20 40 1/2 x 12 THD501200HMG 5 1/2 5 20 5/8 x 5 THDB62500HMG 4 1/2 10 40 5/8 x 6 THDB62600HMG 5 1/2 10 40 5/8 15/16 5/8 x 61/2 THDB62612HMG 5 1/2 10 40 5/8 x 8 THDB62800HMG 5 1/2 10 20 3/4 x 5 THD75500HMG 4 1/2 5 20 3/4 x 6 THDT75600HMG 4 1/2 5 20 3/4 1 1/8 3/4 x 81/2 THD75812HMG 5 1/2 5 10 3/4 x 10 THD75100HMG 5 1/2 5 10 Mechanical galvanizing meets ASTM B695, Class 65, Type 1. Intended for some pressure-treated wood sill plate applications. Not for use in other corrosive or outdoor environments. Visit strongtie.com/info for more corrosion information. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 53 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Heavy-Duty Screw Anchor Countersunk Head Style The countersunk head style is for applications that require a flush-mount profile. Countersinking also leaves a cleaner surface appearance for exposed through-set applications. The anchor head's 6-lobe drive eases installation and is less prone to stripping than traditional recessed anchor heads. Features · Available in many standard lengths in ¼" and 3/8" diameters · Driver bit included in each box Codes: ICC-ES ESR-2713 (concrete); ICC-ES ESR-1056 (masonry); City of LA Supplement within ESR-2713 (concrete); City of LA Supplement within ESR-1056 (masonry); Florida FL15730 (concrete and masonry) Material: Carbon steel Coating: Zinc plated Cracked Concrete CODE LISTED 6-lobe drive Titen HD Countersunk Head Style Additional Installation Information Titen HD Diameter (in.) Bit Size Recommended Steel Fixture Hole Size (in.) Minimum Hole Depth Overdrill (in.) 1/4 T30 3/8 to 7/16 1/8 3/8 T50 1/2 to 9/16 1/4 Suggested fixture hole sizes are for structural steel thicker than 12 gauge only. Larger holes are not required for wood or thinner cold-formed steel members. Titen HD Diameter (in.) ¼ Minimum o Minimum overdrill. See table. 54 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Heavy-Duty Screw Anchor Washer-Head Head Style The washer-head design is commonly used where a minimal head profile is necessary. The model is offered in sizes suitable for use in sill plate applications, and the washer head's low installed profile means modular wall and floor systems can be installed on top with no need for notching the wall framing to accommodate the anchor. The anchor's 6-lobe drive eases driving and is less prone to stripping. Features · Available in many standard lengths in 1/2" and 5/8" diameters · Driver bit included in each box Codes: ICC-ES ESR-2713 (concrete); City of LA Supplement within ESR-2713 (concrete); Florida FL15730 (concrete) Material: Carbon steel Coating: Zinc plated Cracked Concrete CODE LISTED 1" 0.125" 0.645" 1¾" 0.160" 0.835" ½1/2"" 5/8"" 6-lobe drive Additional Installation Information Titen HD Diameter (in.) Bit Size Recommended Steel Fixture Hole Size1,2 (in.) Minimum Hole Depth Overdrill (in.) 1/2 T50 5/8 to 11/16 1/2 5/8 T60 3/4 to 13/16 1/2 1. For anchor threads to clear, fixture hole sizes are suggested for installation through structural steel thicker than 12 gauge. Larger holes are not required for wood or thinner cold-formed steel members. 2. In order for washer head to seat against steel fixture, larger fixture hole may be required to accommodate collar underneath washer head. See the figure above for collar dimensions. Titen HD Washer-Head Head Style / " minim Minimum overdrill. See table. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 55 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Heavy-Duty Screw Anchor Mechanical Anchors Titen HD Anchor Product Data -- Zinc Plated1 Size (in.) Model No. Thread Drill Bit Wrench Length Diameter Size (in.) (in.) (in.) Quantity Box Carton 1/4 x 17/8 THDB25178H 11/2 1/4 3/8 100 500 1/4 x 23/4 THDB25234H 23/8 1/4 3/8 50 250 1/4 x 3 THDB25300H 25/8 1/4 3/8 50 250 1/4 x 31/2 THDB25312H 31/8 1/4 3/8 50 250 1/4 x 4 THDB25400H 35/8 1/4 3/8 50 250 3/8 x 13/4 THD37134H2,3 11/4 3/8 9/16 50 250 3/8 x 21/2 THD37212H2,3 2 3/8 9/16 50 200 3/8 x 3 THD37300H 21/2 3/8 9/16 50 200 3/8 x 4 THD37400H 31/2 3/8 9/16 50 200 3/8 x 5 THD37500H 41/2 3/8 9/16 50 100 3/8 x 6 THD37600H 51/2 3/8 9/16 50 100 1/2 x 3 THD50300H2,4 21/2 1/2 3/4 25 100 1/2 x 4 THD50400H 31/2 1/2 3/4 20 80 1/2 x 5 THD50500H 41/2 1/2 3/4 20 80 1/2 x 6 THD50600H 51/2 1/2 3/4 20 80 1/2 x 61/2 THD50612H 51/2 1/2 3/4 20 40 1/2 x 8 THD50800H 51/2 1/2 3/4 20 40 1/2 x 12 THD501200H 51/2 1/2 3/4 5 25 1/2 x 13 THD501300H 51/2 1/2 3/4 5 25 1/2 x 14 THD501400H 51/2 1/2 3/4 5 25 1/2 x 15 THD501500H 51/2 1/2 3/4 5 25 5/8 x 4 THDB62400H2,4 31/2 5/8 15/16 10 40 5/8 x 5 THDB62500H 41/2 5/8 15/16 10 40 5/8 x 6 THDB62600H 51/2 5/8 15/16 10 40 5/8 x 61/2 THDB62612H 51/2 5/8 15/16 10 40 5/8 x 8 THDB62800H 51/2 5/8 15/16 10 20 5/8 x 10 THDB62100H 51/2 5/8 15/16 10 20 3/4 x 4 THD75400H2,5 31/2 3/4 1 1/8 10 40 3/4 x 5 THD75500H 41/2 3/4 1 1/8 5 20 3/4 x 6 THDT75600H 41/2 3/4 1 1/8 5 20 3/4 x 7 THD75700H 51/2 3/4 1 1/8 5 10 3/4 x 81/2 THD75812H 51/2 3/4 1 1/8 5 10 3/4 x 10 THD75100H 51/2 3/4 1 1/8 5 10 1. Length of anchor is measured from underside of head to end of anchor. 2. These models do not meet minimum embedment depth requirements for strength design. 3. Installation torque shall not exceed 25 ft.-lb. using a manual torque wrench or maximum torque rating of 100 ft.-lb. when installed with impact wrench. 4. Installation torque shall not exceed 50 ft.-lb. using a manual torque wrench or maximum torque rating of 100 ft.-lb. when installed with impact wrench. 5. Installation torque shall not exceed 50 ft.-lb. using a manual torque wrench or maximum torque rating of 135 ft.-lb. when installed with impact wrench. THDT75600H THD75700H 56 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Heavy-Duty Screw Anchor Titen HD Anchor Product Data -- Countersunk -- Zinc Plated Size (in.) Model No. Thread Length (in.) Drill Bit Diameter (in.) Wrench Size (in.) Quantity Box Carton 1/4 x 1 7/8 THDB25178CS 1 1/2 1/4 T30 100 500 1/4 x 2 3/4 THDB25234CS 2 3/8 1/4 T30 50 250 1/4 x 3 1/2 THDB25312CS 3 1/8 1/4 T30 50 250 1/4 x 4 1/2 THDB25412CS 4 1/8 1/4 T30 50 250 3/8 x 2 1/2 THD37212CS 2 3/8 T50 50 200 3/8 x 3 THD37300CS 2 1/2 3/8 T50 50 200 3/8 x 4 THD37400CS 3 1/2 3/8 T50 50 200 3/8 x 5 THD37500CS 4 1/2 3/8 T50 50 100 This model does not meet minimum embedment depth requirements for strength design and require maximum installation torque of 25 ft.-lb. using a torque wrench, driver drill or cordless 1/4" impact driver with a maximum permitted torque rating of 100 ft.-lb. 1. Length of anchor is measured from top of head to bottom of anchor. Titen HD Anchor Product Data -- Washer Head -- Zinc Plated Size (in.) Model No. Thread Length (in.) Drill Bit Diameter (in.) Bit Size Quantity Box Carton 1/2 x 6 THD50600WH 5 1/2 1/2 T50 15 60 1/2 x 8 THD50800WH 5 1/2 1/2 T50 15 30 5/8 x 6 THDB62600WH 5 1/2 5/8 T60 10 40 5/8 x 8 THDB62800WH 5 1/2 5/8 T60 10 20 5/8 x 10 THDB62100WH 5 1/2 5/8 T60 10 20 1. Length of anchor is measured from underside of head to bottom of anchor. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 57 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Stainless-Steel Titen HD® Heavy-Duty Screw Anchor Mechanical Anchors The Titen HD stainless-steel screw anchor for concrete and masonry sets the standard for when the job calls for installation in multiple types of environments. It is the ultimate choice to provide fast and efficient installation, combined with long-lasting corrosion resistance for an unsurpassed peace-of-mind. Cracked Concrete CODE LISTED Innovative -- The serrated carbon-steel threads on the tip of the stainless-steel Titen HD are vital because they undercut the concrete as the anchor is driven into the hole, making way for the rest of the threads to interlock with the concrete. Corrosion Resistant -- Type 304SS has very good corrosion resistance for general exterior environments and those where chemicals such as fertilizers, soil and acid rain are present. Type 316SS has the maximum corrosion resistance for severe environments, such as marine and seaside applications. It is resistant to chlorine, chlorides (salt), sulfuric acids and a wide range of chemicals. Features · Ideal for exterior or corrosive environments · Less carbon steel, less expansion · An extensive variety of sizes offered; along with several different material types to match your installation needs Codes: IAPMO UES ER-493 (concrete); ICC-ES ESR-1056 (masonry); City of LA Supplement within ER-493 (concrete); City of LA Supplement within ESR-1056 (masonry); Florida FL15730 (masonry); FL16230 (concrete) Material: Type 316 and Type 304 stainless steel with carbon-steel lead threads Installation Caution: Holes in steel fixtures to be mounted should match the diameter specified in the table on p. 59 if steel is thicker than 12 gauge. Caution: Use a Titen HD screw anchor one time only -- installing the anchor multiple times may result in excessive thread wear and reduce load capacity. Do not use impact wrenches to install into hollow CMU. Caution: Oversized holes in base material will reduce or eliminate the mechanical interlock of the threads with the base material and reduce the anchor's load capacity. Stainless-Steel Titen HD Screw Anchor US Patents: 8,747,042 B2 and 9,517,519 1. Drill a hole in the base material using a carbide drill bit (complying with ANSI B212.15) with the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to the specified minimum hole depth overdrill (see table on p. 59) to allow the thread tapping dust to settle, and blow it clean using compressed air. (Overhead installations need not be blown clean.) Alternatively, drill the hole deep enough to accommodate embedment depth and the dust from drilling and tapping. 2. Insert the anchor through the fixture and into the hole. 3. Tighten the anchor into the base material until the hex-washer head contacts the fixture. Innovative carbon-steel thread effectively cuts the concrete while significantly limiting the amount of carbon steel in the anchor, minimizing the amount of corrosion potential that can occur in a exterior corrosive environment. 58 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Stainless-Steel Titen HD® Heavy-Duty Screw Anchor Installation Sequence Mechanical Anchors Additional Installation Information Titen HD® Diameter (in.) Wrench Size (in.) Recommended Steel Fixture Hole Size (in.) 1/4 3/8 3/8 to 7/16 3/8 9/16 1/2 to 9/16 1/2 3/4 5/8 to 11/16 5/8 15/16 3/4 to 13/16 3/4 1 1/8 7/8 to 15/16 Minimum Hole Depth Overdrill (in.) 1/8 1/4 1/2 1/2 1/2 M"indimiau. m= ¼" ½ov"edrdiar.ill=. ½" See table. Suggested fixture hole sizes are for structural steel thicker than 12 gauge only. Larger holes are not required for wood or cold-formed steel members. Stainless-Steel Titen HD Anchor Product Data -- Hex Washer Head Size Model No. (in.) (Type 316) Model No. (Type 304) Thread Drill Bit Wrench Length Diameter Size (in.) (in.) (in.) 1/4 x 2 THDC25200H6SS -- 1 7/8 1/4 3/8 1/4 x 23/8 THDC25238H6SS -- 2 1/4 1/4 3/8 1/4 x 3 THDC25300H6SS -- 2 7/8 1/4 3/8 1/4 x 4 THDC25400H6SS -- 3 7/8 1/4 3/8 3/8 x 3 THD37300H6SS THD37300H4SS 2 1/2 3/8 9/16 3/8 x 4 THD37400H6SS THD37400H4SS 3 1/2 3/8 9/16 3/8 x 5 THD37500H6SS THD37500H4SS 4 1/2 3/8 9/16 3/8 x 6 THD37600H6SS THD37600H4SS 5 1/2 3/8 9/16 1/2 x 3 THD50300H6SS THD50300H4SS 21/2 1/2 3/4 1/2 x 4 THD50400H6SS THD50400H4SS 3 1/2 1/2 3/4 1/2 x 5 THD50500H6SS THD50500H4SS 4 1/2 1/2 3/4 1/2 x 6 THD50600H6SS THD50600H4SS 5 1/2 1/2 3/4 1/2 x 61/2 THD50612H6SS THD50612H4SS 6 1/2 3/4 1/2 x 8 THD50800H6SS THD50800H4SS 6 7/8 1/2 3/4 5/8 x 4 THDB62400H6SS THDB62400H4SS 31/2 5/8 15/16 5/8 x 5 THDB62500H6SS THDB62500H4SS 41/2 5/8 15/16 5/8 x 6 THDB62600H6SS THDB62600H4SS 51/2 5/8 15/16 5/8 x 61/2 THDB62612H6SS THDB62612H4SS 6 5/8 15/16 5/8 x 8 THDB62800H6SS THDB62800H4SS 71/16 5/8 15/16 3/4 x 4 THD75400H6SS THD75400H4SS 31/2 3/4 1 1/8 3/4 x 5 THD75500H6SS THD75500H4SS 41/2 3/4 1 1/8 3/4 x 6 THD75600H6SS THD75600H4SS 5 1/2 3/4 1 1/8 3/4 x 7 THD75700H6SS THD75700H4SS 6 1/2 3/4 1 1/8 3/4 x 81/2 THD75812H6SS THD75812H4SS 73/16 3/4 1 1/8 Does not meet minimum embedment in code report. 1. Anchor length is measured from under head to bottom of anchor. Quantity Box Carton 50 250 50 250 50 250 50 250 50 200 50 200 50 100 50 100 25 100 20 80 20 80 20 80 20 40 20 40 10 40 10 40 10 40 10 40 10 20 10 40 5 20 5 20 5 10 5 10 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 59 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Stainless-Steel Titen HD® Heavy-Duty Screw Anchor Stainless-Steel Countersunk Head Style The countersunk head style is for applications that require a flush-mount profile. Countersinking also leaves a cleaner surface appearance for exposed through-set applications. The anchor head's 6-lobe drive eases installation and is less prone to stripping than traditional recessed anchor heads. Features · Available in many standard lengths in ¼" and 3/8" diameters · Countersunk head allows screw anchor applications incompatible with a hex head · Driver bit included in each box Codes: IAPMO UES ER-493 (concrete); ICC-ES ESR-1056 (masonry); City of LA Supplement within ER-493 (concrete); City of LA Supplement within ESR-1056 (masonry); Florida FL15730 (masonry); FL16230 (concrete) Material: Type 316 stainless steel with carbon-steel lead threads Cracked Concrete CODE LISTED 6-lobe drive Stainless-Steel Titen HD Countersunk Head Style Screw Anchor Additional Installation Information Titen HD Diameter (in.) Bit Size Recommended Steel Fixture Hole Size (in.) 1/4 T30 3/8 to 7/16 Minimum Hole Depth Overdrill (in.) 1/8 3/8 T50 1/2 to 9/16 1/4 Suggested fixture hole sizes are for structural steel thicker than 12 gauge only. Larger holes are not required for wood or thinner cold-formed steel members. 60 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Stainless-Steel Titen HD® Heavy-Duty Screw Anchor Installation Sequence Titen HD Diameter (in.) ¼ Minimum o(Msveeeirndtariiblmlle um ov below) Mechanical Anchors Stainless-Steel Titen HD Anchor Product Data -- Countersunk Head Size (in.) Model No. (Type 316) Thread Length (in.) Drill Bit Diameter (in.) Wrench Size (in.) Quantity Box Carton 1/4 x 23/8 THDC25238CS6SS 2 1/4 T30 25 250 1/4 x 3 THDC25300CS6SS 2 5/8 1/4 T30 25 250 1/4 x 4 THDC25400CS6SS 3 5/8 1/4 T30 25 250 3/8 x 2 1/2 THD37212CS6SS 2 3/8 T50 25 125 3/8 x 3 THD37300CS6SS 2 1/2 3/8 T50 25 125 3/8 x 4 THD37400CS6SS 3 1/2 3/8 T50 25 125 These models do not meet minimum embedment depth requirements for strength design and require maximum installation torque of 25 ft.-lb. using a torque wrench, driver drill or cordless 1/4" impact driver with a maximum permitted torque rating of 100 ft.-lb. 1. Anchor length is measured from top of head to bottom of anchor. For additional load information, see strongtie.com. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 61 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Rod Coupler The Titen HD rod coupler is designed to be used in conjunction with a single or multi-story rod tiedown system. This anchor provides a fast and simple way to attach threaded rod to a concrete stem wall or thickened slab footing. Unlike adhesive anchors, the installation requires no special tools, cure time or secondary setting process; just drill a hole and drive the anchor. Features · The serrated cutting teeth and patented thread design enable the Titen HD rod coupler to be installed quickly and easily. Less installation time translates to lower installed cost. · The specialized heat treating process creates tip hardness to facilitate cutting while the body remain ductile. · No special setting tools required. ANSI size bits and standard sockets. · Compatible with threaded rods in 3/8" and 1/2" diameters. Codes: ICC-ES ESR-2713 (concrete); City of LA Supplement within ESR-2713 (concrete); FL15730 (concrete) Material: Carbon steel Coating: Zinc plated Installation Caution: Oversized holes in the base material will reduce or eliminate the mechanical interlock of the threads with base material and will reduce the anchor's load capacity. Use a Titen HD Rod Coupler one time only. Installing the anchor multiple times may result in excessive thread wear and reduce load capacity. 1. Drill a hole using the specified diameter carbide bit into the base material to a depth of at least 1/2" deeper than the required embedment. 2. Blow the hole clean of dust and debris using compressed air. Overhead application need not be blown clean. 3. Tighten the anchor with appropriate size socket until the head sits flush against base material. Titen HD Rod Coupler 62 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Rod Coupler Installation Sequence Mechanical Anchors Washer recommended to resist shear loads 1/2" min. 1/2" min. Titen HD Rod Coupler Product Data Size (in) Model No. Accepts Rod Diameter (in.) Drill Bit Diameter (in.) Wrench Size (in.) 3/8 x 63/4 THD37634RC 3/8 3/8 9/16 1/2 x 93/4 THD50934RC 1/2 1/2 3/4 Quantity Box Carton 25 50 20 40 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 63 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Strong-Bolt® 2 Wedge Anchor Code listed for cracked and uncracked concrete, and masonry applications, the STB2 wedge-type expansion anchor is an optimal choice for high-performance even in seismic and high-wind conditions. Dual undercutting embossments on each clip segment enable secondary expansion should a crack form and intersect the anchor location; this feature significantly increases the ability of the STB2 to carry load if the hole expands. The STB2 has a chamfered top designed to prevent mushrooming during installation, and to ensure the nut can be easily installed/removed. Features · Suitable for horizontal, vertical and overhead applications · Qualified for minimum concrete thickness of 3 1/4", and lightweight concrete-over-metal deck thickness of 2 1/2" and 3 1/4" Head Stamp The head is stamped with the · Fits standard (ANSI) fixtures and installs with common drill bit and tool sizes Codes: ICC-ES ESR-3037 (concrete); length identification letter, bracketed top and bottom by horizontal lines. IAPMO UES ER-240 (carbon steel in CMU); City of LA Supplement within ESR-3037 (concrete); City of LA Supplement within ER-240 (carbon steel in CMU); Florida FL15730 (concrete); FL16230 (masonry); UL File Ex3605; FM 3043342 and 3047639; multiple DOT listings. Meets the requirements of Federal Specifications A-A-1923A, Type 4. Material: Zinc-plated carbon steel or stainless steel (Type 304; Type 316) Cracked Concrete CODE LISTED Material Specifications Anchor Body Nut Carbon steel Carbon steel, ASTM A 563, Grade A Type 304 stainless steel Type 304 stainless steel Type 316 stainless steel Type 316 stainless steel Washer Carbon steel ASTM F844 Type 304 stainless steel Type 316 stainless steel Clip Carbon steel, ASTM A 568 Type 304 or 316 stainless steel Type 316 stainless steel 64 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Strong-Bolt® 2 Wedge Anchor Installation Do not use an impact wrench to set or tighten the Strong-Bolt 2 anchor. Caution: Oversized holes in the base material will make it difficult to set the anchor and will reduce the anchor's load capacity. 1. Drill a hole in the base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to the specified minimum hole depth, and blow it clean using compressed air. (Overhead installations need not be blown clean.) Alternatively, drill the hole deep enough to accommodate embedment depth and dust from drilling. 2. Assemble the anchor with nut and washer so the top of the nut is flush with the top of the anchor. Place the anchor in the fixture, and drive it into the hole until the washer and nut are tight against the fixture. 3. Tighten to the required installation torque. Installation Sequence Strong-Bolt 2 Anchor Installation Data Strong-Bolt 2 Diameter (in.) 1/4 3/8 1/2 5/8 3/4 1 Drill bit size (in.) 1/4 3/8 1/2 5/8 3/4 1 Min. fixture hole (in.) 5/16 7/16 9/16 11/16 7/8 1 1/8 Wrench size (in.) 7/16 9/16 3/4 15/16 1 1/8 1 1/2 Concrete installation torque (ft.-lbf.) Carbon steel 4 Concrete installation torque (ft.-lbf.) Stainless steel 4 30 60 90 150 230 30 65 80 150 -- For length identification head marks on Strong-Bolt 2 wedge anchor, see p. 210. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 65 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Strong-Bolt® 2 Wedge Anchor Mechanical Anchors Strong-Bolt 2 Anchor Product Data -- Carbon Steel and Mechanically Galvanized Size (in.) Carbon Steel Model No. Mechanically Galvanized Model No. Drill Bit Diameter (in.) 1/4 x 1 3/4 STB2-25134 -- 1/4 1/4 x 2 1/4 STB2-25214 -- 1/4 1/4 x 3 1/4 STB2-25314 STB2-25314MG 1/4 3/8 x 21/4 STB2-37214R50 -- 3/8 3/8 x 2 3/4 STB2-37234 -- 3/8 3/8 x 3 STB2-37300 STB2-37300MG 3/8 3/8 x 3 1/2 STB2-37312 -- 3/8 3/8 x 3 3/4 STB2-37334 STB2-37334MG 3/8 3/8 x 5 STB2-37500 STB2-37500MG 3/8 3/8 x 7 STB2-37700 STB2-37700MG 3/8 1/2 x 23/4 STB2-50234R25 STB2-50234MG 1/2 1/2 x 3 3/4 STB2-50334 STB2-50334MG 1/2 1/2 x 4 1/4 STB2-50414 STB2-50414MG 1/2 1/2 x 4 3/4 STB2-50434 -- 1/2 1/2 x 5 1/2 STB2-50512 STB2-50512MG 1/2 1/2 x 7 STB2-50700 STB2-50700MG 1/2 1/2 x 8 1/2 STB2-50812 -- 1/2 1/2 x 10 STB2-50100 STB2-50100MG 1/2 1/2 x 12 STB2-501200R10 -- 1/2 5/8 x 31/2 STB2-62312R20 STB2-62312MG 5/8 5/8 x 4 1/2 STB2-62412 STB2-62412MG 5/8 5/8 x 5 STB2-62500 STB2-62500MG 5/8 5/8 x 6 STB2-62600 STB2-62600MG 5/8 5/8 x 7 STB2-62700 -- 5/8 5/8 x 8 1/2 STB2-62812 STB2-62812MG 5/8 5/8 x 10 STB2-62100 STB2-62100MG 5/8 5/8 x 12 STB2-621200R10 -- 5/8 3/4 x 43/4 STB2-75434R10 STB2-75434MG 3/4 3/4 x 5 1/2 STB2-75512 STB2-75512MG 3/4 3/4 x 6 1/4 STB2-75614 -- 3/4 ¾ x 7 STB2-75700 STB2-75700MG 3/4 ¾ x 8 1/2 STB2-75812 -- 3/4 3/4 x 10 STB2-75100 -- 3/4 3/4 x 12 STB2-751200R5 STB2-751200MG 3/4 1 x 7 STB2-100700 -- 1 1 x 10 STB2-1001000 -- 1 1 x 13 STB2-1001300 -- 1 1 x 15 STB2-1001500 -- 1 Thread Length (in.) 1 5/16 1 7/16 2 7/16 1 1 5/16 1 9/16 2 1/16 2 5/16 3 9/16 5 9/16 1 1/4 2 1/16 2 9/16 3 1/16 3 13/16 5 5/16 6 6 6 1 5/8 2 7/16 2 15/16 3 15/16 4 15/16 4 15/16 6 6 2 5/8 3 3/16 3 15/16 4 11/16 6 6 6 3 1/2 3 1/2 3 1/2 3 1/2 Quantity Box Carton 100 500 100 500 100 500 50 250 50 250 50 250 50 250 50 250 50 200 50 200 25 125 25 100 25 100 25 100 25 100 25 100 25 100 25 100 10 20 20 80 20 80 20 80 20 80 20 80 20 80 20 40 10 20 10 40 10 40 10 40 10 40 10 20 10 20 10 20 5 20 5 10 5 10 5 10 66 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Strong-Bolt® 2 Wedge Anchor Strong-Bolt 2 Anchor Product Data -- Stainless Steel Size (in.) Type 304 Stainless Steel Model No. Type 316 Stainless Steel Model No. Drill Bit Diameter (in.) Thread Length (in.) 1/4 x 1 3/4 STB2-251344SS STB2-251346SS 1/4 1 5/16 1/4 x 2 1/4 STB2-252144SS STB2-252146SS 1/4 1 7/16 1/4 x 3 1/4 STB2-253144SS STB2-253146SS 1/4 2 7/16 3/8 x 21/4 STB2-372144SSR50 STB2-372146SSR50 3/8 1 3/8 x 2 3/4 STB2-372344SS STB2-372346SS 3/8 1 5/16 3/8 x 3 STB2-373004SS STB2-373006SS 3/8 1 9/16 3/8 x 3 1/2 STB2-373124SS STB2-373126SS 3/8 2 1/16 3/8 x 3 3/4 STB2-373344SS STB2-373346SS 3/8 2 5/16 3/8 x 5 STB2-375004SS STB2-375006SS 3/8 3 9/16 3/8 x 7 STB2-377004SS STB2-377006SS 3/8 5 9/16 1/2 x 23/4 STB2-502344SSR25 STB2-502346SSR25 1/2 1 1/4 1/2 x 3 3/4 STB2-503344SS STB2-503346SS 1/2 2 1/16 1/2 x 4 1/4 STB2-504144SS STB2-504146SS 1/2 2 9/16 1/2 x 4 3/4 STB2-504344SS STB2-504346SS 1/2 3 1/16 1/2 x 5 1/2 STB2-505124SS STB2-505126SS 1/2 3 13/16 1/2 x 7 STB2-507004SS STB2-507006SS 1/2 5 5/16 1/2 x 8 1/2 STB2-508124SS STB2-508126SS 1/2 6 1/2 x 10 STB2-501004SS STB2-501006SS 1/2 6 5/8 x 31/2 STB2-623124SSR20 STB2-623126SSR20 5/8 1 5/8 5/8 x 4 1/2 STB2-624124SS STB2-624126SS 5/8 2 7/16 5/8 x 5 STB2-625004SS STB2-625006SS 5/8 2 15/16 5/8 x 6 STB2-626004SS STB2-626006SS 5/8 3 15/16 5/8 x 7 STB2-627004SS STB2-627006SS 5/8 4 15/16 5/8 x 8 1/2 STB2-628124SS STB2-628126SS 5/8 6 5/8 x 10 STB2-621004SS STB2-621006SS 5/8 6 3/4 x 43/4 STB2-754344SSR10 STB2-754346SSR10 3/4 2 1/2 3/4 x 5 1/2 STB2-755124SS STB2-755126SS 3/4 3 3/16 3/4 x 6 1/4 STB2-756144SS STB2-756146SS 3/4 3 15/16 ¾ x 7 STB2-757004SS STB2-757006SS 3/4 4 11/16 ¾ x 8 1/2 STB2-758124SS STB2-758126SS 3/4 6 Quantity Box Carton 100 500 100 500 100 500 50 250 50 250 50 250 50 250 50 250 50 200 50 200 25 125 25 125 25 100 25 100 25 100 25 100 25 50 25 50 20 80 20 80 20 80 20 80 20 80 20 40 10 20 10 40 10 40 10 40 10 40 10 20 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 67 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Sleeve-All® Sleeve Anchor Sleeve-All expanding anchors are pre-assembled, expanding sleeve anchors for use in all types of solid base materials. This anchor is available in acorn, hex, rod coupler, flat or round head style for a wide range of applications. Codes: FM 3017082, 3026805 and 3029959 (carbon steel 3/8" 1/2" diameter); Underwriters Laboratories File Ex3605 (3/8" 3/4" diameter); multiple DOT listings. Meets the requirements of Federal Specification A-A-1922A. Material: Carbon steel or stainless steel Coating: Carbon steel anchors are zinc plated Installation 1. Drill a hole in the base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. 2. Drill the hole to the specified embedment depth, and blow it clean using compressed air. (Overhead installations need not be blown clean.) Alternatively, drill the hole deep enough to accommodate embedment depth and the dust from drilling. 3. Place the anchor in the fixture, and drive it into the hole until the washer and nut are tight against the fixture. 4. Tighten to required installation torque. Caution: Oversized holes will make it difficult to set the anchor and will reduce the anchor's load capacity. Hex Acorn Rod Coupler Flat Head (Phillips drive) Installation Sequence 68 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Sleeve-All® Sleeve Anchor Material Specifications Anchor Body Sleeve Carbon steel (meets minimum 50,000 psi tensile) Carbon steel (SAE J403, Grade 1008 cold-rolled steel) Nut Carbon steel (ASTM A563, Grade A) Washer Carbon steel (SAE J403, Grade 1008/1010 cold-rolled steel) Type 304 stainless steel Type 304 stainless steel Type 304 stainless steel Type 304 stainless steel Sleeve-All Anchor Installation Data Sleeve-All Diameter (in.) 1/4 5/16 3/8 1/2 5/8 3/4 Installation torque (ft.-lb.) 5 8 15 25 50 90 Drill bit size (in.) 1/4 5/16 3/8 1/2 5/8 3/4 Wrench size1 (in.) 3/8 7/16 1/2 9/16 3/4 15/16 Wrench size for coupler nut (in.) 1/2 5/8 3/4 -- 1. Applies to acorn- and hex-head configurations only. Length Identification Head Marks on Sleeve-All Anchors (corresponds to length of anchor -- inches) Mark A B C D E F G H I J K L M N O P Q R S T U V W X Y Z From 11/2 2 21/2 3 31/2 4 41/2 5 51/2 6 61/2 7 71/2 8 81/2 9 91/2 10 11 12 13 14 15 16 17 18 Up to but Not 2 21/2 3 31/2 4 41/2 5 51/2 6 61/2 7 71/2 8 81/2 9 91/2 10 11 12 13 14 15 16 17 18 19 Including Sleeve-All Anchor Product Data -- Stainless Steel Bolt Max. Size Model Head Diameter Fixture (in.) No. Style Threads Thickness per Inch (in.) 3/8 x 17/8 SL37178HSS 3/8 5/1618 3/8 x 3 SL37300HSS Hex 1 1/2 1/2 x 3 SL50300HSS Head 3/4 3/816 1/2 x 4 SL50400HSS 1 3/4 Quantity Box Carton 50 250 50 200 25 100 25 100 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 69 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Sleeve-All® Sleeve Anchor Sleeve-All Anchor Product Data -- Zinc-Plated Carbon Steel Bolt Max. Size Model Head Diameter Fixture Quantity (in.) No. Style Threads Thickness per Inch (in.) Box Carton 1/4 x 1 3/8 SL25138A 1/4 100 500 Acorn Head 3/1624 1/4 x 2 1/4 SL25214A 1 1/8 100 500 5/16 x 1 1/2 5/16 x 2 1/2 SL31112H SL31212H 3/8 100 500 1/420 1 1/16 50 250 3/8 x 1 7/8 SL37178H 3/8 50 250 3/8 x 3 SL37300H 5/1618 1 1/2 50 200 3/8 x 4 SL37400H 2 1/4 50 200 1/2 x 2 1/4 SL50214H 1/2 50 200 1/2 x 3 SL50300H 3/4 25 100 3/816 1/2 x 4 SL50400H 1 3/4 25 100 Hex Head 1/2 x 6 SL50600H 3 3/8 20 80 5/8 x 2 1/4 SL62214H 1/2 25 100 5/8 x 3 5/8 x 4 1/4 SL62300H SL62414H 3/4 20 80 1/213 1 1/2 10 40 5/8 x 6 SL62600H 3 1/4 10 40 3/4 x 2 1/2 SL75212H 1/2 10 40 3/4 x 4 1/4 SL75414H 5/811 7/8 10 40 3/4 x 6 1/4 SL75614H 2 7/8 5 20 1/4 x 2 1/4 x 3 SL25200PF SL25300PF 7/8 100 500 3/1624 1 7/8 50 250 5/16 x 21/2 SL31212PF 1 1/16 50 250 1/420 5/16 x 31/2 SL31312PF Phillips 2 1/16 50 250 3/8 x 2 3/4 SL37234PF Flat Head 1 1/4 50 200 3/8 x 4 3/8 x 5 SL37400PF SL37500PF 2 1/2 50 200 5/1618 3 1/2 50 200 3/8 x 6 SL37600PF 4 1/2 50 200 Sleeve-All Anchor (with rod coupler) Product Data -- Zinc-Plated Carbon Steel Size (in.) Model No. Accepts Rod Diameter (in.) Wrench Size Quantity Box Carton 3/8 x 1 7/8 SL37178C 3/8 1/2 50 200 1/2 x 2 1/4 SL50214C 1/2 5/8 25 100 5/8 x 2 1/4 SL62214C 5/8 3/4 20 80 70 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Easy-Set Pin-Drive Expansion Anchor The Easy-Set is a pin-drive expansion anchor for medium- and heavy-duty fastening applications into concrete and grout-filled block. Integrated nut and washer help keep track of parts. Material: Carbon steel Coating: Yellow zinc dichromate plated Installation Caution: Oversized holes in the base material will make it difficult to set the anchor and will reduce the anchor's load capacity. 1. Drill a hole in the base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to the specified embedment depth plus 1/4" to allow for pin extension and blow it clean using compressed air. (Overhead installations need not be blown clean.) Alternatively, drill the hole deep enough to accommodate embedment depth and the dust from drilling. 2. Adjust the nut for required embedment. Place the anchor through the fixture and into the hole. 3. Hammer the center pin until the bottom of the head is flush with top of anchor. Installation Sequence Easy-Set (EZAC) Easy-Set Anchor Installation Data Easy-Set Diameter (in.) 3/8 1/2 5/8 Drill bit size (in.) 3/8 Min. fixture hole size (in.) 7/16 Wrench size (in.) 9/16 1/2 5/8 9/16 11/16 3/4 15/16 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 71 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Easy-Set Pin-Drive Expansion Anchor EZAC Product Data Size Model (in.) No. 3/8 x 2 3/8 3/8 x 3 1/2 3/8 x 4 3/4 1/2 x 2 3/4 1/2 x 3 1/2 1/2 x 4 3/4 1/2 x 6 5/8 x 4 5/8 x 4 3/4 5/8 x 6 EZAC37238 EZAC37312 EZAC37434 EZAC50234 EZAC50312 EZAC50434 EZAC50600 EZAC62400 EZAC62434 EZAC62600 Thread Length (in.) 1 1 1/8 1 1/2 1 1 1/8 1 1/2 2 1 5/8 1 5/8 2 Quantity Box Carton 50 250 50 250 50 200 25 125 25 125 25 100 25 100 15 60 15 60 15 60 72 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Tie-Wire Wedge Anchor The tie-wire anchor is a wedge-style expansion anchor for use in normal-weight concrete or in concrete over metal deck. With a tri-segmented, dual-embossed clip, the tie-wire anchor is ideal for the installation of acoustic ceiling grid and is easily set with the claw of a hammer. Features · 1/4" eyelet for easy threading of wire · Sets with claw of hammer · Tri-segmented clip -- each segment adjusts independently to hole irregularities · Dual embossments on each clip segment enable the clip to undercut into the concrete, increasing follow-up expansion · Wedge-style expansion anchor for use in normal-weight concrete or concrete over metal deck Material: Carbon steel Coating: Zinc plated Installation 1. Drill a hole at least 1 1/4" deep using a 1/4"-diameter carbide tipped bit. 2. Drive the anchor into the hole until the bottom of the head is flush with the base material. 3. Set the anchor by prying/pulling the head with the claw end of the hammer. Tie-Wire Wedge Anchor Installation Sequence Size (in.) 1/4 x 1 1/4 Model No. TW25114 Drill Bit Diameter (in.) 1/4 Eyelet Hole Size (in.) 1/4 Quantity Box Carton 100 500 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 73 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen TurboTM Concrete and Masonry Screw Anchor Mechanical Anchors The Titen Turbo screw anchor features an innovative Torque Reduction Channel to trap drilling dust where it can't obstruct thread action, significantly reducing binding, stripping, and snapping without compromising strength. The patented reverse thread design enables smooth driving with less torque while providing superior holding power. The Torque Reduction Channel also allows more space for dust to help prevent anchors from bottoming out in smaller-diameter screw holes. The Titen Turbo screw anchors feature a serrated leading edge to cut into concrete or masonry, and a pointed tip for fast, easy installation in wood-to-concrete and wood-to-wood anchoring applications. Features · Patent-pending Torque Reduction Channel that displaces dust where it can't obstruct the thread action, reducing the likelihood of binding in the hole. · Availability with either a hex head, or, for a flush profile, a 6-lobe-drive countersunk flat head or trim head. · The 6-lobe drive's larger contact area provides better bit grip for reduced cam-outs, more torque, better performance and longer bit life. · 6-lobe bit included in packaging for countersunk flat head and trim head version. · Superior tension load performance compared to leading competitors in the market. · Matched-tolerance bit not required; use a standard ANSI drill bit for installation. · Serrated screw point for easier starts when fastening wood. Titen Turbo Flat Head Screw Patent Pending · Designed for installation with an impact driver or cordless drill. Installation using the Titen Turbo Installation Tool is recommended. · Use in dry interior environments only. · Code listed in accordance with ICC-ES AC193 for uncracked concrete and ICC-ES AC106 for masonry applications without cleaning dust from predrilled holes. Titen Turbo Hex-Head Screw Patent Pending Titen Turbo Trim-Head Screw Codes: IAPMO UES ER-712 (uncracked concrete) (City of LA Supplement within ER-712); IAPMO UES ER-716 (masonry) (City of LA Supplement within ER-716); FL16230 (concrete and masonry) 6-lobe drive Material: Carbon steel Coating: Zinc plated with baked ceramic coating 74 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen TurboTM Concrete and Masonry Screw Anchor Versatile Applications Installation Sequence Sliding door track installation Window frames ½" min. 1¾" max. Furring strips S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 75 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen TurboTM Concrete and Masonry Screw Anchor Blue Titen Turbo Product Data (3/16" diameter) Size (in.) 3/16 x 1 1/4 3/16 x 1 3/4 3/16 x 2 1/4 3/16 x 2 3/4 3/16 x 3 1/4 3/16 x 3 3/4 3/16 x 1 1/4 3/16 x 1 3/4 3/16 x 2 1/4 3/16 x 2 3/4 3/16 x 3 1/4 3/16 x 3 3/4 Head Model Style No. 1/4" hex T25 6-lobe flat TNT18114H TNT18134H TNT18214H TNT18234H TNT18314H TNT18334H TNT18114TF TNT18134TF TNT18214TF TNT18234TF TNT18314TF TNT18334TF Drill Bit Diameter (in.) 5/32 5/32 Quantity Pack Carton 100 1,600 100 500 100 500 100 500 100 400 100 400 100 1,600 100 500 100 500 100 500 100 400 100 400 Blue Titen Turbo Product Data (1/4" diameter) Size Head (in.) Style Model No. Drill Bit Diameter (in.) Quantity Pack Carton 1/4 x 1 1/4 TNT25114H 100 1,600 1/4 x 1 3/4 TNT25134H 100 500 1/4 x 2 1/4 TNT25214H 100 500 1/4 x 2 3/4 TNT25234H 100 500 1/4 x 31/4 5/16" hex TNT25314H 3/16 100 400 1/4 x 3 3/4 TNT25334H 100 400 1/4 x 4 TNT25400H 100 400 1/4 x 5 TNT25500H 100 400 1/4 x 6 TNT25600H 100 400 1/4 x 1 1/4 TNT25114TF 100 1,600 1/4 x 1 3/4 TNT25134TF 100 500 1/4 x 2 1/4 TNT25214TF 1/4 x 2 3/4 T30 6-lobe flat TNT25234TF 3/16 1/4 x 3 1/4 TNT25314TF 100 500 100 500 100 400 1/4 x 3 3/4 TNT25334TF 100 400 1/4 x 4 TNT25400TF 100 400 76 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen TurboTM Concrete and Masonry Screw Anchor White Titen Turbo Product Data (6-Lobe Flat Head) Size (in.) 3/16 x 1 1/4 Head Style Model No. TNTW18114TF Drill Bit Diameter (in.) Quantity Pack Carton 100 1,600 3/16 x 1 3/4 TNTW18134TF 100 500 3/16 x 2 1/4 3/16 x 2 3/4 T25 6-lobe flat TNTW18214TF TNTW18234TF 5/32 100 500 100 500 3/16 x 3 1/4 TNTW18314TF 100 400 3/16 x 3 3/4 TNTW18334TF 100 400 1/4 x 1 1/4 TNTW25114TF 100 1,600 1/4 x 1 3/4 TNTW25134TF 100 500 1/4 x 2 1/4 1/4 x 2 3/4 T30 6-lobe flat TNTW25214TF TNTW25234TF 3/16 100 500 100 500 1/4 x 3 1/4 TNTW25314TF 100 400 1/4 x 3 3/4 TNTW25334TF 100 400 Silver Titen Turbo Product Data (6-Lobe Flat Head) Size (in.) 3/16 x 1 3/4 3/16 x 2 3/4 3/16 x 3 3/4 1/4 x 2 3/4 1/4 x 3 1/4 Head Style T25 6-lobe flat T30 6-lobe flat Model No. TNTS18134TFB TNTS18234TFB TNTS18334TFB TNTS25234TFB TNTS25314TFB Drill Bit Diameter (in.) 5/32 3/16 Quantity 1,000 1,000 1,000 1,000 1,000 White Titen Turbo Trim-Head Product Data (6-Lobe) Size (in.) 1/4 x 2 3/4 1/4 x 3 1/4 1/4 x 2 3/4 1/4 x 3 1/4 Model No. TNTW25234TTR TNTW25314TTR TNTW25234TTRB TNTW25314TTRB Drill Bit Diameter (in.) 3/16 Bit Quantity Size Box Carton 100 500 100 400 T25 1,000 -- 1,000 -- Bronze Titen Turbo Trim-Head Product Data (6-Lobe) Size (in.) 1/4 x 2 3/4 1/4 x 3 1/4 1/4 x 2 3/4 1/4 x 3 1/4 Model No. TNTB25234TTR TNTB25314TTR TNTB25234TTRB TNTB25314TTRB Drill Bit Diameter (in.) 3/16 Bit Quantity Size Box Carton 100 500 100 400 T25 1,000 -- 1,000 -- S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 77 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen TurboTM Concrete and Masonry Screw Anchor Titen Turbo Screw Anchor -- Installation Tool Six-piece kit includes: · 6-lobe bit socket · T25 and T30 bits · 1/4" and 5/16" hex sockets · Canvas storage bag Titen Turbo Installation Tool Model No. Quantity Clamshell Carton TNTINSTALLKIT 1 4 Titen Turbo Screw Anchor Installation Kit Mechanical Anchors Titen Turbo Screw Anchor -- Drill Bits Model No. Description Pack Quantity MDB15312C1 Masonry bit 5/32" x 31/2" 1 card 1 MDB15412C1 Masonry bit 5/32" x 41/2" 1 card 1 MDB15412C4 Masonry bit 5/32" x 41/2" 4 card 4 MDB15512C1 Masonry bit 5/32" x 51/2" 1 card 1 MDB18312C1 Masonry bit 3/16" x 31/2" 1 card 1 MDB18412C1 Masonry bit 3/16" x 41/2" 1 card 1 MDB18412C4 Masonry bit 3/16" x 41/2" 4 card 4 MDB18512C1 Masonry bit 3/16" x 51/2" 1 card 1 Carton Quantity 10 10 10 10 10 10 10 10 Titen Turbo Screw Anchor -- SDS-plus® Drill Bits Size (in.) 5/32 x 6 5/32 x 7 3/16 x 5 3/16 x 6 3/16 x 7 Model No. MDPL01506H MDPL01507H MDPL01805H MDPL01806H MDPL01807H For Screw Diameter (in.) 3/16 1/4 Drilling Depth (in.) 31/8 41/8 23/8 31/8 41/8 Overall Length (in.) 6 7 5 6 7 Titen drivers are sold individually. Titen Turbo Screw Drill Bit -- Bulk Packs* Diameter (in.) Drilling Depth (in.) Overall Length (in.) For Screw Diameter (in.) Model No. 5/32 4 1/8 7 3/16 MDPL01507H-R25 3/16 4 1/8 7 1/4 MDPL01807H-R25 *SDS-plus shank. SDS-plus Shank Bit 78 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen® Stainless-Steel Concrete and Masonry Screw Stainless-steel Titen screws are ideal for attaching various types of components to concrete and masonry, such as fastening electrical boxes or light fixtures. They offer the versatility of our standard Titen screws with enhanced corrosion protection. Available in hex and Phillips flat head. Features · Suitable for concrete, brick, grout-filled CMU and hollow-block applications · Suitable for some preservative-treated wood applications · Acceptable for exterior use · Titen drill bits included in each box · Available in lengths from 11/4"4" · Installation using the Titen Installation Kit is recommended Codes: FL2355 Material: Type 410 stainless steel Coating: Zinc plated with a protective overcoat Installation Caution: Industry studies show that hardened fasteners can experience performance problems in wet or corrosive environments. Steps must be taken to prevent inadvertent sustained loads above the listed allowable loads. Overtightening and bending moments can initiate cracks detrimental to the hardened screw's performance. Use the Simpson Strong-Tie Titen installation tool kit as it has a bit that is designed to reduce the potential for overtightening the screw. Caution: Oversized holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity. Titen Stainless- Steel Phillips FlatHead Screw (PFSS) Titen Stainless- Steel Hex-Head Screw (HSS) 1. Drill a hole in the base material using the appropriate diameter carbide drill bit as specified in the table. Drill the hole to the specified embedment depth plus 1/2" to allow the thread tapping dust to settle and blow it clean using compressed air. Overhead installations need not be blown clean. Alternatively, drill the hole deep enough to accommodate embedment depth and dust from drilling and tapping. 2. Position fixture, insert screw and tighten using drill and Titen screw installation tool fitted with a hex socket or Phillips bit. Preservative-treated wood applications: suitable for use in non-ammonia formulations of CCA, ACQ-C, ACQ-D, CA-B, SBX/DOT and zinc borate. Acceptable for use in exterior environments. Use caution not to damage coating during installation. The 410 stainless-steel Titen with top coat provides "medium" corrosion protection. Recommendations are based on testing and experience at time of publication and may change. Simpson Strong-Tie cannot provide estimates on service life of screws. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 79 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen® Stainless-Steel Concrete and Masonry Screw Installation Sequence Mechanical Anchors 1/2" 11/2" max. min. Stainless-Steel Titen Product Data Size Head (in.) Style Model No. Drill Bit Diameter (in.) Quantity Box Carton 1/4 x 11/4 TTN25114HSS 1/4 x 13/4 TTN25134HSS 1/4 x 21/4 TTN25214HSS 1/4 x 23/4 Hex head TTN25234HSS 3/16 1/4 x 31/4 TTN25314HSS 1/4 x 33/4 TTN25334HSS 1/4 x 4 TTN25400HSS 1/4 x 11/4 TTN25114PFSS 1/4 x 13/4 TTN25134PFSS 1/4 x 21/4 TTN25214PFSS 1/4 x 23/4 Phillips flat head TTN25234PFSS 3/16 1/4 x 31/4 TTN25314PFSS 1/4 x 33/4 TTN25334PFSS 1/4 x 4 TTN25400PFSS One drill bit is included in each box. 100 1,600 100 500 100 500 100 500 100 400 100 400 100 400 100 1,600 100 500 100 500 100 500 100 400 100 400 100 400 See p. 78 for Titen screw installation accessories. 80 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Threaded Rod Hanger The Titen HD threaded rod hanger is a high-strength screw anchor designed to suspend threaded rod from concrete slabs, beams or concrete over metal in order to hang pipes, cable trays and other HVAC equipment. The anchor offers low installation torque with no secondary setting, and has been tested to offer industry-leading performance in cracked and uncracked concrete -- even in seismic loading conditions. Cracked Concrete CODE LISTED Features · Thread design undercuts to efficiently transfer the load to the base material · Serrated cutting teeth and patented thread design enable quick and easy installation · Specialized heat-treating process creates tip hardness to facilitate cutting while the anchor body remains ductile · No special drill bit required -- designed to install using standard-sized ANSI tolerance drill bits · Installs with standard-sized sockets Codes: ICC-ES ESR-2713; City of LA Supplement within ESR-2713; FL15730; Factory Mutual 3031136 (THD50234RH) and 3061897 (THDB37158RH) Material: Carbon steel THD50234RH (3/8"-dia. shank) Coating: Zinc plated Installation Caution: Oversized holes in the base material will reduce or eliminate the mechanical interlock of the threads with base material and will reduce the anchor's load capacity. Caution: Use a Titen HD rod hanger one time only. Installing the anchor multiple times may result in excessive thread wear and reduce load capacity. 1. Drill a hole using the specified diameter carbide bit into the base material to the specified embedment depth plus minimum hole depth overdrill (see the product data table on p. 82). THDB37158RH THDB25158RH (1/4"-dia. shank) (1/4"-dia. shank) 2. Blow the hole clean of dust and debris using compressed air. 3. Install the anchor into the hole. 4. Fully insert threaded rod. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 81 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Titen HD® Threaded Rod Hanger Installation Sequence Mechanical Anchors O1/v8e"rdmriillnd.epth (see product data table below) 1/8" min. 1/8" min. 1/8" min. Titen HD Threaded Rod Hanger Product Data Size (in.) Model No. Accepts Rod Dia. (in.) Drill Bit Dia. (in.) Wrench Size (in.) Min. Embed. (in.) Hole Depth Overdrill (in.) Quantity Box Carton 1/4 x 15/8 THDB25158RH 1/4 1/4 3/8 1 5/8 1/8 100 500 3/8 x 15/8 THDB37158RH 3/8 1/4 1/2 1 5/8 1/8 50 200 1/2 x 23/4 THD50234RH 1/2 3/8 11/16 21/2 1/4 50 100 82 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Steel Rod Hanger Threaded Rod Anchor System The Simpson Strong-Tie® steel rod hanger is a one-piece fastening system for suspending ¼" and 3/8" threaded rod. Vertical rod hangers are designed to suspend threaded rod in overhead applications from steel joists and beams. Horizontal rod hangers are available for applications requiring installation into the side of joists, columns and overhead members. Both rod hangers provide attachment points for use in pipe hanging, fire protection, electrical conduit and cable-tray applications. Recommended for use in dry, interior, non-corrosive environments only. Features · Threaded anchors for rod-hanging applications in steel members · Suitable to be installed horizontally or vertically in overhead applications · Self-drilling tip, no predrilling required · Recommend installation with a 18V cordless drill/driver · Custom-matched nut driver sets anchor to optimal depth Codes: FM 3058980; UL File Ex3605 Material: Carbon steel Coating: Zinc plated RSH Horizontal Steel Rod Hangers RSV Vertical Steel Rod Hangers Nut Driver Custom-matched nut driver sets the rod hangers to optimal depth every time. Model No. Description RND62 Nut driver Quantity Box Carton 10 60 RND62 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 83 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Steel Rod Hanger Threaded Rod Anchor System Steel Rod Hangers Rod Diameter Size (in.) Model No. Drill Point Application Steel Thickness Range Quantity Box Carton 1/4 1/4" x 1" with nut RSH25100N #3 20 ga. - 12 ga. 1/4 #1220 x 11/2" RSH25112-5 #5 20 ga. - 1/4" Horizontal 25 250 3/8 1/4" x 1" with nut RSH37100N #3 20 ga. - 12 ga. 3/8 #1220 x 11/2" RSH37112N-5 #5 20 ga. - 1/4" 1/4 1/4" x 1" RSV25100 #3 3/8 1/4" x 1" with nut RSV37100N #3 3/8 1/4" x 1 1/2" RSV37112 #3 3/8 1/4" x 1 1/2" with nut RSV37112N #3 3/8 #1220 x 11/2" RSV37112N-5 #5 20 ga. - 12 ga. 20 ga. - 12 ga. 20 ga. - 14 ga. Vertical 25 250 20 ga. - 14 ga. 20 ga. - 1/4" 3/8 1/4" x 2" RSV37200 #3 20 ga. - 14 ga. Vertical Installation If included 84 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Steel Rod Hanger Threaded Rod Anchor System Horizontal Installation If included S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 85 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Wood Rod Hanger Threaded Rod Anchor System The wood rod hanger from Simpson Strong-Tie is a one-piece fastening system for suspending ¼" or 3/8" threaded rod. Vertical rod hangers are designed to suspend threaded rod in overhead applications from wood members. Horizontal rod hangers are available for applications requiring installation into the side of joists, columns and overhead members. Both rod hangers provide attachment points for use in pipe hanging, fire protection, electrical conduit and cable-tray applications. Recommended for use in dry, interior, non-corrosive environments only. Features · Threaded anchors for rod-hanging applications in wood · Suitable for installation horizontally or vertically in overhead applications · No predrilling required · Type-17 point provides for fast starts · Recommend installation with a 18V cordless drill/driver or 18V cordless impact driver Codes: FM 3058980; UL File Ex3605 Material: Carbon steel Coating: Zinc plated RWV Vertical Wood Rod Hanger RWH Horizontal Wood Rod Hanger Wood Rod Hangers Rod Diameter (in.) Size (in.) 1/4 1/4 x 2 3/8 1/4 x 1 3/8 1/4 x 2 3/8 5/16 x 2 1/2 1/4 1/4 x 1 3/8 1/4 x 2 3/8 5/16 x 2 1/2 Model No. RWV25200 RWV37100 RWV37200 RWV37212 RWH25100 RWH37200 RWH37212 Application Point Style Vertical Type 17 Horizontal Type 17 Type-17 point for use in wood Quantity Box Carton 25 250 25 250 86 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Wood Rod Hanger Threaded Rod Anchor System Installation Sequence 1. Attach RND62 nut driver to a drill. 2. Insert rod hanger into the RND62 nut driver. 3. Using rotation-only mode, drive rod hanger until it contacts the surface. Do not over-tighten. RND62 nut driver will disengage the rod hanger at the appropriate depth to prevent overdriving. 4. Insert threaded rod. Minimum thread engagement should be equal to the nominal diameter of the threaded insert. Vertical Wood Rod Hanger Horizontal Wood Rod Hanger S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 87 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Drop-In Internally Threaded Anchor (DIAB) Expansion shell anchors for use in solid base materials Simpson Strong-Tie introduces a redesigned Drop-In Anchor (DIAB) that provides easier installation into base materials. Improved geometry in the preassembled expansion plug improves setting capability so the anchor installs with 40% fewer hammer strikes than previous versions. These displacement-controlled expansion anchors are easily set by driving the plug toward the bottom of the anchor using either the hand- or power-setting tools. DIAB anchors feature a positive-set marking indicator at the top of the anchor -- helping you see more clearly when proper installation has taken place. Use a Simpson Strong-Tie fixed-depth stop bit to take the guesswork out of drilling to the correct depth. The fluted design of the tip draws debris away from the hole during drilling, allowing for a cleaner installation. Key features · New design offers easier installation than previous drop-in anchor design -- sets with 40% fewer hammer hits · Positive-set marking system indicates when anchor is properly set · Lipped drop-in version available for flush installation · Hand- and power-setting tools available for fast, easy and economical installation · Fixed-depth stop bit helps you drill to the correct depth every time · Available in coil-thread version for 1/2" and 3/4" coil-thread rod Codes: FM 3053987; UL File Ex3605; multiple DOT listings. Meets the requirements of Federal Specification A-A-55614, Type 1. Material: Carbon steel Coating: Zinc plated Drop-In 88 Lipped Drop-In Coil-Thread Drop-In S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Drop-In Internally Threaded Anchor (DIAB) Fixed-Depth Drill Bits for DIAB Model No. Drill Bit Diameter (in.) Drill Depth (in.) MDPL037DIA 3/8 1 1/16 MDPL050DIA 1/2 1 11/16 MDPL062DIA 5/8 2 1/16 Drop-In Anchor (in.) 1/4 3/8 1/2 Fixed-Depth Drill Bit Anchor being set with hand setting tool. Anchor being set with SDS setting tool. Positive set indicator. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 89 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Drop-In Internally Threaded Anchor (DIAB) Drop-In Anchor Rod Size (in.) Model No. Drill Bit Bolt Body Thread Dia. Threads Length Length (in.) (per in.) (in.) (in.) Quantity Box Carton 1/4 DIAB25 3/8 20 1 3/8 100 500 3/8 DIAB37 1/2 16 1 9/16 5/8 50 250 1/2 DIAB50 5/8 13 2 3/4 50 200 5/8 DIAB62 7/8 11 2 1/2 1 25 100 3/4 DIAB75 1 10 3 1/8 1 1/4 20 80 Drop-In Lipped Drop-In Anchor Rod Size (in.) Model No. Drill Bit Bolt Body Thread Dia. Threads Length Length (in.) (per in.) (in.) (in.) Quantity Box Carton 1/4 DIABL25 3/8 20 1 3/8 100 500 3/8 DIABL37 1/2 16 1 9/16 5/8 50 250 1/2 DIABL50 5/8 13 2 3/4 50 200 Lipped Drop-In Coil-Thread Drop-In Anchor Rod Size (in.) Model No. Drill Bit Bolt Body Thread Dia. Threads Length Length (in.) (per in.) (in.) (in.) Quantity Box Carton 1/2 DIAB50C1 5/8 6 2 3/4 50 200 3/4 DIAB75C1 1 4 1/2 3 1/8 1 1/4 20 80 1. DIAB50C and DIAB75C accept 1/2" and 3/4" coil-thread rod, respectively. Coil-Thread Drop-In 90 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Drop-In Internally Threaded Anchor (DIAB) DIABST Drop-In Anchor Hand-Setting Tool Hand-setting tool designed for use with the Simpson Strong-Tie® Drop-In anchor (DIAB), ensuring fast, easy and economical installation. Mechanical Anchors Hand Setting Tool Model No. Description Box Quantity DIABST25 Setting tool for use with Drop-In models DIAB25, DIABL25 10 DIABST37 Setting tool for use with Drop-In models DIAB37, DIABL37 10 DIABST50 Setting tool for use with Drop-In models DIAB50, DIABL50, DIAB50C 10 DIABST62 Setting tool for use with Drop-In model DIAB62 5 DIABST75 Setting tool for use with Drop-In models DIAB75, DIAB75C 5 1. Setting tools sold separately. Tools may be ordered by the piece. Carton Qty. 50 50 50 25 20 DIABST (SDS-plus®) Drop-In Anchor Power-Setting Tool Power-setting tool featuring an SDS-plus shank, designed for use with the Simpson Strong-Tie Drop-In anchor (DIAB), ensuring fast, easy and economical installation. Power Setting Tool Model No. Description Box Quantity DIABST25-SDS Power-setting tool for use with Drop-In models DIAB25, DIABL25 10 DIABST37-SDS Power-setting tool for use with Drop-In models DIAB37, DIABL37 10 DIABST50-SDS Power-setting tool for use with Drop-In models DIAB50, DIABL50, DIAB50C 10 1. Setting tools sold separately. Tools may be ordered by the piece. Carton Qty. 50 50 50 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 91 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Drop-In Internally Threaded Anchor (DIAB) DIAB Manual Installation Caution: Oversized holes will reduce the anchors load capacity. 1. Drill a hole in the base material using the appropriate diameter carbide drill bit or fixed-depth bit as specified in the table. Drill the hole to the specified embedment. For fixed-depth bits drill the hole until the shoulder of the bit contacts the surface of the base material. Then blow the hole clean of dust and debris using compressed air. Overhead installations need not be blown clean. 2. Insert the anchor into the hole. Tap with hammer until flush against the surface. 3. Using the designated Drop-In setting tool, drive expander plug towards the bottom of the anchor until the shoulder of the setting tool makes contact with the top of the anchor. When properly set four indentations will be visible on the top of the anchor indicating full expansion. 4. Insert bolt or threaded rod. Minimum thread engagement should be equal to the nominal diameter of the threaded insert. !! !! 92 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Drop-In Internally Threaded Anchor (DIAB) DIAB SDS Installation Caution: Oversized holes will reduce the anchors load capacity. 1. Drill a hole in the base material using the appropriate diameter carbide drill bit or fixed-depth drill bit as specified in the table. Drill the hole to the specified embedment. For fixed-depth bits drill the hole until the shoulder of the bit contacts the surface of the base material. Then blow the hole clean of dust and debris using compressed air. Overhead installations need not be blown clean. 2. Insert the anchor into the hole. Tap with hammer until flush against the surface. 3. Attach SDS Drop-In setting tool to a drill. Drive expander plug towards the bottom of the anchor using only hammer mode until the shoulder of the setting tool makes contact with the top of the anchor. When properly set four indentations will be visible on the top of the anchor indicating full expansion. 4. Insert bolt or threaded rod. Minimum thread engagement should be equal to the nominal diameter of the threaded insert. ! ! ! S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 93 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Drop-In Short / Drop-In Stainless Steel Internally Threaded Anchor (DIA) Drop-in anchors are internally threaded drop-in expansion anchors for use in flush-mount applications in solid base materials. Available in stainless steel (DIA) or short (DIAS) version. Minimum thread engagement should be equal to the nominal diameter of the threaded insert. Features · Lipped edge (DIAS) eliminates need for precisely drilled hole depth · Hand- and power-setting tools available for fast, easy and economical installation · Fixed-depth stop bit helps you drill to the correct depth every time · Short length (DIAS) enables shallow embedment to help avoid drilling into rebar or pre-stressed/ post-tensioned cables · Short drop-in anchors include a setting tool compatible with the anchor to ensure consistent installation Codes: DOT; Factory Mutual 3017082; Underwriters Laboratories File Ex3605. Meets the requirements of Federal Specifications A-A-55614, Type I. Material: Stainless steel and carbon steel Coating: Carbon steel; zinc plated Installation Caution: The load tables list values based upon results from the most recent testing and may not reflect those in current code reports. Where code jurisdictions apply, consult the current reports for applicable load values. 1. Drill a hole in the base material using the appropriate diameter carbide drill bit as specified in the table. Drill the hole to the specified embedment depth plus 1/8" for flush mounting. Blow the hole clean using compressed air. Overhead installations need not be blown clean. 2. Insert designated anchor into hole. Tap with hammer until flush against surface. 3. Using the designated drop-in setting tool, drive expander plug toward the bottom of the anchor until shoulder of setting tool makes contact with the top of the anchor. 4. Minimum thread engagement should be equal to the nominal diameter of the threaded insert. Caution: Oversized holes will make it difficult to set the anchor and will reduce the anchor's load capacity. Drop-In Stainless Steel Short Drop-In 94 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Drop-In Short / Drop-In Stainless Steel Internally Threaded Anchor (DIA) Installation Sequence 1/8" min. Mechanical Anchors Drop-In Anchor Product Data -- Stainless Steel Rod Type 303/304 Size Stainless (in.) Model No. Type 316 Stainless Model No. Drill Bit Bolt Body Diameter Threads Length (in.) (per in.) (in.) Thread Length (in.) 1/4 DIA25SS DIA256SS 3/8 20 1 3/8 3/8 DIA37SS DIA376SS 1/2 16 1 9/16 5/8 1/2 DIA50SS DIA506SS 5/8 13 2 3/4 5/8 DIA62SS -- 7/8 11 2 1/2 1 3/4 DIA75SS -- 1 10 3 1/8 1 1/4 Quantity Box Carton 100 500 50 250 50 200 25 100 20 80 Short Drop-In Anchor Product Data Rod Size (in.) Model No. Drill Bit Diameter (in.) Bolt Threads (per in.) Body Length (in.) Thread Length (in.) 3/8 DIA37S1 1/2 16 3/4 1/4 1/2 DIA50S1 5/8 13 1 5/16 1. A dedicated setting tool is included with each box of DIA37S and DIA50S. Quantity Box Carton 100 500 50 200 Material Specifications Anchor Component Anchor body Expander plug Thread Zinc Plated Carbon Steel Meets minimum 70,000 psi tensile Meets minimum 50,000 psi tensile UNC/Coil-thread Component Material Type 303/304 Stainless Steel AISI 303. Meets chemical requirements of ASTM A582 AISI 303 UNC Type 316 Stainless Steel Type 316 Type 316 UNC S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 95 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Hollow Drop-In Internally Threaded Anchor The Simpson Strong-Tie® Hollow Drop-In Anchor (HDIA) is an internally threaded, flush-mount expansion anchor for use in hollow materials such as CMU and hollow-core plank, as well as in solid base materials such as brick, normal-weight and lightweight concrete. Features · Suitable for suspending conduit, cable trays, pipe supports, fire sprinklers and suspended lighting into concrete · Expansion design allows HDIA to anchor into CMU, hollow-core plank, brick, normal-weight concrete and lightweight concrete · Internally threaded anchor allows for easy bolt removal Codes: Factory Mutual 3053987 (3/8"1/2" diameter); Underwriters Laboratories File Ex3605 (3/8"1/2" diameter) Material: Die-cast Zamac 3 alloy shell with carbon-steel cone or 304 stainless-steel cone Hollow Drop-In Anchor (HDIA) Hollow Drop-In Anchor Size (in.) Model No. Drill Bit Diameter (in.) Threads (per in.) 1/4 HDIA25 3/8 20 1/4 HDIA25SS 3/8 20 5/16 HDIA31 5/8 18 3/8 HDIA37 5/8 16 3/8 HDIA37SS 5/8 16 1/2 HDIA50 3/4 13 5/8 HDIA62 1 11 Overall Anchor Length (in.) 3/4 3/4 1 1/4 1 1/4 1 1/4 1 3/4 2 Quantity Package Qty. 100 Carton Qty. 1,600 100 1,600 50 200 50 200 50 200 50 200 25 125 96 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Hollow Drop-In Internally Threaded Anchor HDIASTH Setting Tool for Hollow Materials Setting tool designed to set the Hollow Drop-In internally threaded anchor in hollow materials such as CMU and hollow-core plank. Model No. Description Size Carton (in.) Qty. Setting tool for use with HDIASTH25 Hollow Drop-In models 1/4 25 HDIA25, HDIA25SS Setting tool for use with HDIASTH31 Hollow Drop-In model 5/16 25 HDIA31 Setting tool for use with HDIASTH37 Hollow Drop-In models 3/8 25 HDIA37, HDIA37SS Setting tool for use with HDIASTH50 Hollow Drop-In model 1/2 25 HDIA50 Setting tool for use with HDIASTH62 Hollow Drop-In model 5/8 10 HDIA62 1. Tools sold separately. Tools may be ordered by the piece. HDIASTH Setting Tool HDIASTS Setting Tool for Solid Materials Setting tool designed to set the Hollow Drop-In internally threaded anchor in solid materials such as brick, normal-weight and lightweight concrete. HDIASTS Setting Tool Model No. Description Size (in.) Box Qty. Carton Qty. HDIASTS25 Setting tool for use with Hollow Drop-In models HDIA25, HDIA25SS 1/4 25 125 HDIASTS31-37 Setting tool for use with Hollow Drop-In models HDIA31, HDIA37, HDIA37SS 5/16 3/8 10 50 HDIASTS50 Setting tool for use with Hollow Drop-In model HDIA50 1/2 10 50 HDIASTS62 Setting tool for use with Hollow Drop-In model HDIA62 5/8 5 20 1. Tools sold separately. Tools may be ordered by the piece. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 97 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Hollow Drop-In Internally Threaded Anchor Installation Instructions: Solid Base (using solid setting tool) · Drill a hole in the base material using the appropriate diameter carbide drill bit as specified in the table. Drill the hole to the specified embedment depth. · Blow the hole clean using compressed air. Overhead installations need not be blown clean. · Insert the HDIA into hole. Tap with hammer until flush against surface. · Using the designated setting tool, drive the anchor to the bottom of the drilled hole. After the anchor reaches the bottom of the drilled hole, perform an additional three hammer blows against the setting tool to drive the anchor body over the cone. · Position fixture; insert fastener and tighten. Mechanical Anchors 98 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Hollow Drop-In Internally Threaded Anchor Installation Instructions: Hollow Base (using hollow setting tool) · Drill a hole in the base material using the appropriate diameter carbide drill bit as specified in the table. · Thread the HDIA onto the designated setting tool for hollow base materials. · Insert the HDIA into the hole. Tap the setting tool until the face of the tool contacts the surface. · Rotate the setting tool a minimum of two turns to set the anchor. · Remove the setting tool. · Position fixture; insert fastener and tighten. Mechanical Anchors 1 1/4" minimum thickness Min. 2 turns Remove S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 99 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Zinc NailonTM Pin Drive Anchors Zinc Nailon anchors are low-cost, easy-to-install anchors for applications under static loads. Features · Available with carbon and stainless-steel pins · Pin and head configuration designed to make anchor tamper-resistant Code: Meets Federal Specification A-A-1925A, Type 1 Materials · Body -- Die-cast Zamac 3 alloy · Pin -- Carbon steel; Type 304 stainless steel Installation Caution: Not for use in overhead applications. Caution: Nailon anchors are not recommended for eccentric tension (prying) loads -- capacity will be greatly reduced in such applications 1. Drill a hole in base material using a carbide drill bit the same diameter as the nominal diameter of the anchor to be installed. Drill the hole to specified embedment depth, plus 1/4" for pin extension, and blow hole clean using compressed air. Alternatively, drill the hole deep enough to accommodate embedment depth and dust from drilling. 2. Position fixture and insert Nailon anchor. 3. Tap with hammer until flush with fixture, then drive pin until flush with top of head. Zinc Nailon Anchor (mushroom) Installation Sequence ¼" ¼m"inm. in. 100 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Zinc NailonTM Pin Drive Anchors Zinc Nailon Product Data Size Carbon Steel Pin Stainless-Steel Pin Quantity (in.) Model No. Model No. Box Carton Bulk 3/16 x 7/8 ZN18078 -- 100 1,600 3,000 1/4 x 3/4 ZN25034 ZN25034SS 100 500 2,000 1/4 x 1 ZN25100 ZN25100SS 100 500 1,500 1/4 x 1 1/4 ZN25114 ZN25114SS 100 500 1,500 1/4 x 1 1/2 ZN25112 ZN25112SS 100 500 1,000 1/4 x 2 ZN25200 ZN25200SS 100 400 1,000 1/4 x 2 1/2 ZN25212 ZN25212SS 100 400 1,000 1/4 x 3 ZN25300 ZN25300SS 100 400 1,000 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 101 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crimp Drive® Anchor The crimp anchor is an easy-to-install expansion anchor for use in concrete and grout-filled block. The pre-formed curvature along the shaft creates an expansion mechanism that secures the anchor in place and eliminates the need for a secondary tightening procedure. This speeds up anchor installation and reduces the overall cost. Five crimp anchor head styles are available to handle different applications that include fastening wood or light-gauge steel, attaching concrete formwork, hanging overhead support for sprinkler pipes or suspended ceiling panels. Codes: Factory Mutual 3031136 for the 3/8" rod coupler. Material: Carbon steel, stainless steel Coating: Zinc plated and mechanically galvanized Head Styles: Mushroom, rod coupler, countersunk, tie-wire and duplex Installation Warning: Industry studies show that hardened fasteners can experience performance problems in wet or corrosive environments. Accordingly, with the exception of the duplex anchor, use these products in dry, interior and non-corrosive environments only. 1. Drill a hole using the specified diameter carbide bit into the base material to a depth of at least 1/2" deeper than the required embedment. 2. Blow the hole clean of dust and debris using compressed air. Overhead application need not be blown clean. Where a fixture is used, drive the anchor through the fixture into the hole until the head sits flush against the fixture. 3. Be sure the anchor is driven to the required embedment depth. The rod coupler and tie-wire models should be driven in until the head is seated against the surface of the base material. Mushroom Head Countersunk Head Rod Coupler Tie-Wire 102 Duplex S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crimp Drive® Anchor Installation Sequence Rod Coupler Tie-Wire Mushroom Head Duplex Countersunk Head Installation Sequence Duplex-head anchor may be removed with a claw hammer. Length Identification Head Marks on Mushroom, Countersunk and Duplex-Head Crimp Drive Anchors (corresponds to length of anchor -- inches) Mark o A B C D E F From 1 1 1/2 2 2 1/2 3 3 1/2 4 Up to but Not Including 11/2 2 2 1/2 3 3 1/2 4 4 1/2 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 103 Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crimp Drive® Anchor Crimp Drive Anchor Product Data Size (in.) Model No. Head Style/Finish Drill Bit Dia. (in.) Min. Fixture Hole Size (in.) Min. Embed. (in.) Quantity Pkg. Carton Qty. Qty. 3/16 x 11/4 CD18114M 3/16 x 2 CD18200M 3/16 x 21/2 CD18212M 3/16 3/16 x 3 CD18300M 3/16 x 31/2 CD18312M 3/16 x 4 CD18400M 1/4 x 1 CD25100M 1/4 x 1 1/4 1/4 x 1 1/2 CD25114M CD25112M Mushroom head / zinc plated 1/4 x 2 CD25200M 1/4 1/4 x 2 1/2 CD25212M 1/4 x 3 CD25300M 1/4 x 3 1/2 CD25312M 1/4 x 4 CD25400M 3/8 x 2 CD37200M 3/8 3/8 x 3 CD37300M Mushroom 1/4 x 3 CD25300MG head / mechanically 1/4 galvanized 1/4" rod coupler CD25114RC Rod coupler / 3/16 3/8" rod coupler CD37112RC zinc plated 1/4 3/16 x 21/2 CD18212C 3/16 x 3 CD18300C 3/16 3/16 x 4 CD18400C 1/4 x 1 1/2 CD25112C Countersunk 1/4 x 2 CD25200C head / 1/4 x 2 1/2 CD25212C zinc plated 1/4 1/4 x 3 CD25300C 1/4 x 3 1/2 CD25312C 1/4 x 4 CD25400C 1/4 x 3 CD25300CMG Countersunk head / mechanically 1/4 1/4 x 4 CD25400CMG galvanized1 1/4" Tie Wire CD25118T Tie Wire / zinc plated 1/4 1/4" duplex CD25234D Duplex head / zinc plated 1/4 7/8 100 1 1/4 100 1 1/4 100 1/4 1 1/4 100 1 1/4 100 1 1/4 100 7/8 100 7/8 100 1 1/4 100 1 1/4 100 5/16 1 1/4 100 1 1/4 100 1 1/4 100 1 1/4 100 1 3/4 25 7/16 1 3/4 25 5/16 1 1/4 100 N/A 1 1/4 100 N/A 1 1/2 50 1 1/4 100 1/4 1 1/4 100 1 1/4 100 1 1/4 100 1 1/4 100 1 1/4 100 5/16 1 1/4 100 1 1/4 100 1 1/4 100 1 1/4 100 5/16 1 1/4 100 N/A 1 1/8 100 5/16 1 1/4 100 1. Mechanical galvanizing meets ASTM B695, Class 55, Type 1. Intended for some pressure-treated wood sill plate applications. Not for use in other corrosive or outdoor environments. See strongtie.com for details. 1,600 500 500 500 500 500 1,600 1,600 1,600 500 500 500 500 500 125 125 500 500 250 500 500 500 500 500 500 500 400 400 500 400 500 500 104 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CSD/DSD Split-Drive Anchors The Split-Drive anchor is a one-piece expansion anchor that can be installed in concrete, grout-filled block and stone. As the anchor is driven in, the split-type expansion mechanism on the working end compresses and exerts force against the walls of the hole. Features · Available in countersunk (CSD) and duplex-head (DSD) styles · DSD anchor can be removed with a claw hammer for temporary applications Material: Carbon steel Coating: Zinc plated; mechanically galvanized Installation Warning (CSD only): Industry studies show that hardened fasteners can experience performance problems in wet or corrosive environments. Accordingly, use these products in dry, interior and non-corrosive environments only. Caution: Oversized holes in the base material will greatly reduce the anchor's load capacity. For CSD, embedment depths greater than 1 1/2" may cause bending during installation. 1. Drill a hole in base material using a 1/4"-diameter carbide-tipped drill. Drill hole to specified embedment depth and blow clean using compressed air. (Overhead installation need not be blown clean.) Alternatively, drill hole deep enough to accommodate embedment depth and dust from drilling. Position fixture and insert split-drive anchor through fixture hole. 2. For CSD, 3/8"-diameter fixture hole is recommended for hard fixtures such as steel. For DSD, 5/16"-diameter fixture hole is recommended. 3. Drive anchor until head is flush against fixture. DSD (duplex) S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. CSD (countersunk) 105 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CSD/DSD Split-Drive Anchors Installation Sequence Mechanical Anchors DSD anchor may be removed with a claw hammer. CSD/DSD Product Data Size Model (in.) No. 1/4 x 1 1/2 CSD25112 Head Style/Finish Drill Bit Diameter (in.) Quantity Box Carton 100 500 1/4 x 2 CSD25200 100 500 1/4 x 2 1/2 1/4 x 3 CSD25212 CSD25300 Countersunk head zinc plated 100 500 1/4 100 400 1/4 x 3 1/2 CSD25312 100 400 1/4 x 4 CSD25400 100 400 1/4 x 3 1/4 x 4 CSD25300MG CSD25400MG Countersunk head mechanically galvanized1 100 400 1/4 100 400 1/4 x 3 DSD25300 Duplex head zinc plated 1/4 100 400 1. Mechanical galvanizing meets ASTM B695, Class 55, Type 1. Intended for some preservative-treated wood sill plate applications. Not for use in other corrosive or outdoor environments. See strongtie.com for details. 106 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Mechanical Anchors Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Sure Wall Drywall Anchor Sure Wall anchors are self-drilling drywall anchors and provide excellent holding value and greater capacity than screws alone. This anchor cuts threads into drywall, greatly increasing the bearing surface and strength of the fastening. Features · Self-drilling -- may be installed in gypsum board drywall with only a screwdriver · Easy to remove and reinstall Material: Die-cast zinc or reinforced nylon Sure Wall Nylon Sure Wall Zinc Sure Wall Product Data Screw Size Model No. Packaged with Screws Style Packaged without Screws Quantity Box Carton Applications #8 x 11/4 SWN08LS-R100 SWN08L-R100 Nylon 100 500 3/8", 1/2" drywall, ceiling tile #8 x 11/4 SWZ08LS-R100 SWZ08L-R100 Zinc 100 500 3/8", 1/2", 5/8" drywall, plaster Installation Sequence S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 107 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Powder-Actuated Tool / Fastener Suitability This matrix matches Simpson Strong-Tie powder-actuated tools with the fasteners typically used with each tool. General-Purpose Tools Fasteners PTP-27L Direct Fastening Solutions PDPA-XXX 0.300"-Headed Fasteners with 0.157" Shank Diameter ü PDPAWL-XXX ü PDPAS-XXX -- PDPAT-XXX ü PCLDPA-XXX ü PECLDPA-XXX ü PTRHA3-XXX ü PINW-XXX 0.300"-Headed Fasteners with 0.145" Shank Diameter ü PINWP-XXX ü PHBC-XXX ü PCC-XXX ü PBXDP-100 PKP-250 PSLV3-XXX ü 8 mm-Headed Fasteners ü 3/8"-Headed Fasteners / Threaded Studs -- See strongtie.com for more tool and fastener product information. 110 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Powder-Actuated Tool / Fastener Suitability PT-27 General-Purpose Tools PT-22A-RB ü = Suitable -- = Not suitable PT-22HA-RB Direct Fastening Solutions 0.300"-Headed Fasteners with 0.157" Shank Diameter ü Max. 2 1/2" ü ü ü ü ü -- -- -- ü ü ü ü ü ü ü ü ü ü ü ü 0.300"-Headed Fasteners with 0.145" Shank Diameter ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 8 mm-Headed Fasteners ü ü ü 3/8"-Headed Fasteners / Threaded Studs -- -- -- S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 111 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Gas Tool / Fastener Suitability Direct Fastening Solutions Gas Tool Fuel Cell 0.106"- Diameter Shank Pins 0.118"- / 0.102"- Diameter Stepped-Shank Pins 112 GCN-MEPMAGKT GFC34 GDP GDPS S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Gas Tool / Fastener Suitability Spiral Knurl Pins GDPSK Direct Fastening Solutions GRH GCL Mechanical, Electrical, Plumbing and Ceiling Pins GCT GTS GCC GAC GW S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. GTH 113 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry GCN-MEPMAGKT Gas-Actuated Concrete Nailer The GCN-MEPMAGKT gas-actuated concrete nailer is a portable fastener tool used for attaching light-duty fixtures to concrete, steel, concrete block (CMU), lightweight concrete over metal deck and cold-formed steel. As a magazine tool, GCN-MEPMAGKT is ideal for attaching drywall track, furring strips, hat track and angle track using GDP and GDPS collated pins. GCN-MEPMAGKT offers you the flexibility of having two tools in one convenient package -- a magazine tool and a single-shot tool -- since the magazine is easily removed without additional assembly tools. As a single-shot tool, the GCN-MEPMAGKT is great for attaching mechanical, electrical and plumbing fixtures with pre-assembled pins/accessories such as washer pins, ceiling clips, top hats and threaded studs. The pre-assembled pins for the single-shot tool use 0.283"-headed fasteners with 0.126"-diameter shanks for stronger fastening performance. The tool used as a single-shot or with magazine offer portability without the need for cords or hoses, and are actuated with GFC34 gas fuel cells. Features · Power to drive 0.126"-diameter pins · Flexibility to drive 1/2" to 11/2" pins · Flexibility to drive 0.250" and 0.286" diameterheaded pins · Pin-depth adjustment dial · Battery charge indicator light · Comfortable "sure-grip" rubber handle and ladder hook · Easy start-up procedure: Insert fuel cell, insert battery, load pins, and begin use Specifications · Tool dimensions: Length 12.5" (317.5 mm), 17" (432.8 mm) Tool weight: 6.6 lb. (3 kg), 8.3 lb. (3.7 kg) with magazine Height 15.3" (389 mm) · Compatible fasteners: L ength: 1/2" (12.7 mm) to 1 1/2" (38 mm) Head diameter: 0.244" and 0.283" Shank diameter: 0.106" to 0.128" · Average number of shots per battery charge: 3,300 GCN-MEPMAGKT · Average number of shots per fuel cell: 1,200 · Average cyclic firing rate: 2 shots per second · Average battery charge time (6V NiMH): 2 hours · Operation temperature range: 20°120°F (6°49°C) · Magazine capacity: 42 · Maximum fastenings before reloading: 40 The magazine is designed to retain two pins during use to prevent the tool from discharging without a fastener (which can damage the tool and possibly cause injury). The tool will resume normal operation when additional pins are loaded. 114 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry GCN-MEPMAGKT Gas-Actuated Concrete Nailer Minimum Cleaning Required The GCN-MEPMAGKT has a very efficient ignition system that provides complete fuel combustion. This results in a cleaner operating tool, which in turn results in more tool energy and higher productivity. To maintain maximum level of productivity, periodic cleaning is recommended. · Only requires cleaning every 20,000 shots · Easy access to the air filter and piston chamber The GCN-MEPMAGKT gas-actuated concrete nailer is ideal for fastening: · Drywall track · Lath wire for stucco · Water-proofing membrane · Furring strips Direct Fastening Solutions (without magazine) (with magazine) GCN-MEPMAGKT S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 115 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Gas-Actuated Concrete Nailing GDP Pins GDP concrete pins are designed to work with the GCN-MEPMAGKT gas-actuated concrete nailer as well as with many major brand gas-actuated concrete nailer tools. The patented 10-fastener strip is designed with breakaway plastic. The pins are designed for use in A36 and A572 steel, concrete, CMU block and sand-lightweight concrete over metal deck. Codes: ICC-ES ESR-2811 (including City of LA Supplement); Florida FL-15730 GDP US Patent: 605,016 GDP -- 0.240"-Dia. Head with 0.106"-Dia. Shank Gas Drive Pins Model No. Pin Length (in.) Shank Dia. (in.) Quantity Pins per Pack Packs/ + 1 Fuel Cell Carton Simpson Strong-Tie Tools GDP-50KT 1/2 GDP-62KT 5/8 GDP-75KT GDP-100KT 3/4 0.106 1,000 1 5 GCN-MEPMAGKT GDP-125KT 1 1/4 GDP-150KT 1 1/2 GDPS Pins The GDPS pins are also designed to work in the GCN-MEPMAGKT gas-actuated nailer tool for installation into steel. The step-shank pin, with a smaller diameter tip, facilitates easier penetration, while the larger diameter upper shank provides more shear resistance and successful installation. Codes: ICC-ES ESR-2811 (including City of LA Supplement); Florida FL-15730 GDPS GDPS -- 0.240"-Dia. Head with 0.118"/0.102"-Dia. Stepped-Shank Gas Drive Pins Model No. Pin Length (in.) Shank Dia. (in.) Quantity Pins per Pack Packs/ + 1 Fuel Cell Carton Simpson Strong-Tie Tools GDPS-50KT 1/2 GDPS-62KT 5/8 0.118 / 0.102 1,000 5 GCN-MEPMAGKT GDPS-75KT 3/4 116 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Gas-Actuated Concrete Nailing Spiral Knurl Gas Pins GDPSK gas pins are designed for attaching plywood and OSB to cold-formed steel studs. The spiral knurl provides a positive lock and resists back-out. Installed with the GCN-MEPMAGKT, the GDPSK-138 gas pin provides faster installation and setup times, which contributes to lower labor costs. The hardened pins quickly and cleanly pierce the cold-formed steel and leave the pin head flush with the wood fixture. The 13/8"-length pin can be used for 1/2"3/4"-thick plywood, and 1422 gauge steel. GDPSK GDPSK -- 0.244"-Dia. Head with 0.106"-Dia. Shank Spiral Knurl Gas Drive Pins Model No. Pin Length (in.) Shank Dia. (in.) Quantity Pins per Pack Packs/ + 1 Fuel Cell Carton GDPSK-138KT 1 3/8 0.106 1,000 5 Simpson Strong-Tie Tools GCN-MEPMAGKT GWL-100 Lathing Washer and GMR-2 Magnetic Ring The GWL-100 lathing washer is used with the GCN-MEPMAGKT tool and attaches lath to the wall surface for overlaying scratch coats, brown coats and stucco. The washers are held onto the nose of the tool with the new GMR-2 magnetic ring and are attached to the substrate (including concrete and CMU) with GDP pins, which fasten through the washer. No extra tools are needed to install the magnetic ring to the nosepiece of the tool. GWL-100 Lathing Washer and Magnetic Ring Model No. Description Quantity Pack Carton GWL-100 Lathing washer, 1" diameter 1,000 5,000 GMR-2 Magnetic ring for GCN-MEPMAGKT 1 900 Lathing washer and magnetic rings are sold separately. GMR-2 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 117 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Gas-Actuated Concrete Nailing Fuel Cell The GFC34 fuel cell is designed to operate with the GCN-MEPMAGKT and with many major-brand gas-actuated concrete nailer tools. The fuel cell provides 1,200 shots and can operate at temperatures between 20° and 120°F (6°49°C). The fuel cells are offered individually or in a two-per-pack clamshell. Additionally, one fuel cell is included with each pack of 1,000 pins. Gas Fuel Cells for the GCN-MEPMAGKT Model No. Description Pack Quantity GFC Fuel Cell Packs/ Carton Simpson Strong-Tie Tool GFC34 34-gram fuel cells 12 GFC34-RC2 (2) 34-gram fuel cells 2 -- GCN-MEPMAGKT 6 118 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Gas-Actuated Concrete Nailing GCN-MEPMAGKT Gas-Actuated Pins and Assemblies for Mechanical, Electrical and Plumbing (MEP) and Ceiling Applications Pre-assembled MEP and ceiling fasteners are available for use with the GCN-MEPMAGKT concrete nailer designed for high-volume applications, such as affixing conduit clips, rod hangers, cable ties and ceiling clips. With their 0.283" heads, these versatile pins and assemblies can also be used with common powder-actuated tools when fastening into harder substrates (structural steel or extra-hard concrete) when required. Codes: ICC-ES ESR-2811; Florida FL-15730 Direct Fastening Solutions GRH GCL GCT GTS GCC GAC GW GTH Mechanical, Electrical, Plumbing and Ceiling Gas-Actuated Pins Model No. Pin Diameter Length (in.) (in.) Description Pack Qty. Simpson Strong-Tie Tools GRH25-R100 0.126 GRH37-R100 GCC50-R100 GCC75-R100 GCC100-R100 GCC125-R50 GCL50-R50 GCL75-R25 GAC-R100 GCT-R50 GW50-R200 GW75-R200 GW100-R100 0.126 0.126 0.126 0.126 0.126 0.126 0.126 0.126 0.126 0.128/ 0.110 0.126 0.126 1 1/4" 20 threaded rod hanger (0.063" thick) with pin 100 1 3/8" 16 threaded rod hanger (0.063" thick) with pin 100 1 1/2" conduit clip (0.047" thick) with pin 100 1 3/4" conduit clip (0.059" thick) with pin 100 1 1" conduit clip (0.059" thick) with pin 100 1 11/4" conduit clip (0.071" thick) with pin 50 1 1/2" conduit clamp (0.047" thick) with pin 50 1 3/4" conduit clamp (0.047" thick) with pin 25 GCN-MEPMAGKT 1 90°ceiling angle clip (0.071" thick) with pin 100 1 Tie-strap holder (0.0315" thick) with pin 50 1/2 1/2" dome washer stepped-shank pin 200 3/4 1/2" dome washer pin 200 1 1/2" dome washer pin 100 GTS4-5075-R200 0.128 11/4 1/4" 20 threaded stud (3/4" shank and 1/2" thread) 200 GTH-R200 0.126 1 Top-Hat pin 200 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 119 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Extension Pole Tools PEPT6 or PEPT8 PEPT6LR or PEPT8LR Advantages · Available in 6' and 8' lengths · Lightweight · Eliminates need for scaffolding · Rugged and durable design Extension Poles for PT-27 Model No. Description PEPT6 Complete 6' pole PEPT8 Complete 8' pole Quantity 1 1 Extension Poles for PTP-27L, GCN-MEPMAGKT Model No. Description Quantity PEPT6LR Complete 6' pole 1 PEPT8LR Complete 8' pole 1 120 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry PAT Tool Matrix Powder-Actuated Fastening Systems This matrix matches Simpson Strong-Tie powder-actuated tools with the trades that would typically use each tool. The selection is based upon the features of the tool matching the needs of the trade. Best PTP-27L Better PT-27 Good PT-22A DIY PT-22HA Direct Fastening Solutions Features · Automatic · Adjustable power · Low recoil · Low noise · Up to 3" pin length · Semi-automatic · Versatile · Reliable professional-grade tool · Up to 21/2" pin length (3" pin with washer) · Single shot · Economical professional-grade tool · Up to 3" pin length · Single shot · Hammer activated · Medium duty · Up to 3" pin length Contractor / Trade Wood Framer ü ü ü ü CFS Framer ü ü ü MEP ü ü ü Acoustics/ Overhead ü ü ü Remodeling ü ü ü ü DIY ü ü ü S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 121 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry PTP-27L Premium Tool The PTP-27L is a powder-actuated fastening tool designed to provide versatility and ease of use on the jobsite. This single-shot tool delivers productive fastening with automatic piston reset, which enables the user to simply load and shoot. Direct Fastening Solutions Adjustable power increases versatility PTP-27L Features · Adjustable power for fastening versatility: 11 1/2 power-level range from a single strip · Easy disassembly for cleaning and maintenance · No manual resetting of piston required · Operator comfort: cushioned grip, reduced recoil and sound-dampening muffler for quiet operation Key Fastening Applications · Sill plate installation · Washered pin installation · Insulation fastening · Forming work · Drywall track and cold-formed steel installation Specifications · Fastener Length: 1/2"3" · Fastener Type: 0.300" (or 8 mm) diameter headed · Firing Action: Automatic · Load Caliber: 0.27 strip loads, brown through purple (levels 26) · Length: 17 3/4" · Weight: 6.5 Ib. 122 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry PTP-27L Premium Tool Tool is sold in a rugged tool box complete with · Operator's manual · Spall suppressor · Tools for disassembly · Safety glasses / ear plugs · Cleaning brushes · Operator's exam and caution sign · Gloves · Five replacement rubber returners Direct Fastening Solutions The full line of Simpson Strong-Tie powder loads and fasteners begins on p. 129. Common Replacement Parts PTP-27L Part No. Description PTP-274810 Baseplate PTP-273820 Fastener Guide PTP-273320 Piston PTP-273306 Piston Disc PTP-274305 Rubber Returner Complementary Products Extension pole tools for the PTP-27L available in 6' and 8' lengths. PEPT6LR or PEPT8LR Extension pole tools for the PTP-27L -- see p. 120 for details. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 123 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry PT-27 General-Purpose Tool The PT-27 is a semi-automatic and fast-cycling fastening tool that is engineered for continuous use, high reliability and low maintenance. This versatile tool fires a variety of fastener types and lengths. Direct Fastening Solutions PT-27 Key Fastening Applications · Acoustical ceiling fixtures · Electrical fixtures · Sill-plate installation · Drywall track and cold-formed steel installation · Water proofing material and/or lathing Specifications · Fastener Length: 1/2"2 1/2" (3" washered) · Fastener Type: 0.300" or 8 mm-headed fasteners or 1/4"-20 threaded studs · Firing Action: Semi-automatic · Load Caliber: 0.27 strip loads, brown through red (levels 25) · Length: 13 1/2" · Weight: 5 lb., 4 oz. Tool is sold in a rugged tool box complete with · Operator's manual · Spall suppressor · Tools for disassembly · Safety glasses / ear plugs · Cleaning brushes · Operator's exam and caution sign The full line of Simpson Strong-Tie powder loads and fasteners begins on p. 129. 124 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry PT-27 General-Purpose Tool Common Replacement Parts -- PT-27 Part No. Description PT-301014 Annular spring PT-301013 Ball bearing (6 mm) PT-301006 Barrel PT-301009 Baseplate PT-301903 Piston -- Flat (includes ring) PT-301208 Piston ring PT-301012 Piston stop PT-301011 Shear clip PT-27PK1 Normal wear part replacement kit PT-MK1 Tool cleaning kit For tool repair and maintenance kits, and complete tool schematics and parts list, visit strongtie.com. Complementary Products Extension pole tool for the PT-27 available in 6' and 8' lengths. PEPT6 Tool and PEPT8 Tool Extension pole tool for the PT-27 -- see p. 120 for details. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 125 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry PT-22A General-Purpose Tool The PT-22A is a powder-actuated tool that uses 0.22 caliber "A" crimp loads, has single-shot firing action and is engineered for continuous use, high reliability and low maintenance. PT-22A-RB Key Fastening Applications · Furring strips · Framing pins · Electrical boxes · Ceiling clips Specifications · Fastener Length: 2 1/2" · Fastener Type: 0.300" or 8 mm-headed fasteners or 1/4"20 threaded studs · Firing Action: Single shot · Load Caliber: 0.22 single "A" crimp loads, brown through yellow (levels 24). Note: Not for use with 0.22 caliber straight wall loads. · Length: 13 7/8" · Weight: 4.4 Ib. PT-22A-RB Retail Package Product Data Model No. Description Quantity Tools per Retail Package Retail Packages per Carton PT-22A-RB 0.22 caliber, single-shot, trigger-activated tool 1 2 126 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry PT-22A General-Purpose Tool Common Replacement Parts Part No. Description PT22A-02 Piston buffer PT22A-13 Piston reset cap PT22A-11 Piston reset pin PT22A-12 Piston reset spring PT22A-03 Piston with ring 1. Complete tool schematics and parts list available at strongtie.com. Direct Fastening Solutions PT-22A-RB The full line of Simpson Strong-Tie powder loads and fasteners begins on p. 129. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 127 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry PT-22HA General-Purpose Tool The PT-22HA is a hammer-activated tool engineered for low maintenance and economy. The tool offers three levels of power: Brown through yellow loads (levels 24). PT-22HA-RB Key Fastening Applications · Remodeling · Maintenance · Electricians · Telecommunications Specifications · Fastener Length: 1/2"2 1/2" · Fastener Type: 0.300" or 8 mm-headed fasteners or 1/4"20 threaded studs · Firing Action: Single shot, hammer activated · Load Caliber: 0.22 single "A" crimp loads, brown through yellow (levels 24). Note: Not for use with 0.22 caliber straight wall loads. · Length: 14 1/4" · Weight: 2 lb., 12 oz. PT-22HA-RB Retail Package Product Data Model No. Description Quantity Tools per Retail Package Retail Packages per Carton PT-22HA-RB 0.22 caliber, single-shot, hammer-activated tool 1 4 The PT-22HA-RB comes packaged in a retail clamshell ready for merchandising. 128 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Powder Loads for Powder-Actuated Tools 0.22 Caliber "A" Crimp Loads -- Single Shot Model No. Caliber Load Color Level Quantity Pack Carton Simpson Strong-Tie Tools P22AC2 0.22 Brown 2 P22AC2A P22AC3 0.22 Green 3 P22AC3A 100 10,000 PT-22A PT-22HA P22AC4 0.22 Yellow 4 P22AC4A Note: An "A" at the end of the model number denotes an imported load. No "A" indicates a domestic load. P22AC 0.25 Caliber Plastic 10-Shot Strip Loads Model No. Caliber Load Color Level Quantity Pack Carton P25SL3 0.25 Green 3 P25SL4 0.25 Yellow 4 100 10,000 P25SL5 0.25 Red 5 P25SL S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 129 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Powder Loads for Powder-Actuated Tools 0.27 Caliber Single-Shot Loads -- Long Model No. Caliber Load Color Level Quantity Pack Carton P27LVL4 0.27 Yellow 4 P27LVL5 0.27 Red 5 100 10,000 P27LVL6 0.27 Purple 6 P27LVL 0.27 Caliber Plastic 10-Shot Strip Loads Model No. Caliber Load Color Level Quantity Pack Carton P27SL2 0.27 Brown 2 P27SL2A P27SL3 0.27 Green 3 P27SL3A P27SL4 0.27 Yellow 4 P27SL4A 100 10,000 P27SL5 0.27 Red 5 P27SL5A P27SL6 0.27 Purple 6 Note: An "A" at the end of the model number denotes an imported load. No "A" indicates a domestic load. Simpson Strong-Tie Tools PTP-27L PT-27 PTP-27L P27SL 130 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Fasteners for Powder-Actuated Tools Simpson Strong-Tie powder-actuated drive pins are a hardened steel, designed to fasten building components to normal weight concrete, lightweight concrete, concrete over metal deck, steel and masonry. PDPA pins are designed to work with Simpson Strong-Tie powder-actuated tool systems as well as other common tools. The following is a chart of models, code listing, use and a page reference to product sku information. Model PDPA Code Listing ICC-ES Florida Use Page ESR-2138 FL-15730 Attachment of cold-formed steel or wood to structure 132 PDPAWL ESR-2138 FL-15730 Attachment of cold-formed steel or wood to structure with additional bearing surface 132 PDPAS ESR-2138 FL-15730 Attachment of cold-formed steel or wood to structure (collated pins) 133 PDPAT ESR-2138 FL-15730 Attachment of cold-formed steel to structure with additional clamping 133 PCLDPA ESR-2138 FL-15730 Attachment of suspended ceilings and overhead applications 133 PECLDPA ESR-2138 FL-15730 Attachment of suspended ceilings and overhead applications 133 PTRHA ESR-2138 FL-15730 Attachment of suspended ceiling, piping and other overhead items using threaded rod 134 PINW ESR-2138 FL-15730 Attachment of insulation board (metal washers) 134 PINWP ESR-2138 FL-15730 Attachment of insulation board (plastic washers) 134 PHBC -- -- Attachment of rebar and dowel basket anchorage 135 PBXDP -- -- Attachment of BX cables to structure 135 PCC -- -- Attachment of conduits to structure 135 PSLV3 ESR-2138 FL-15730 Threaded support attachment to structure 135 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 131 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Fasteners for Powder-Actuated Tools PDPA -- 0.300"-Dia. Head with 0.157"-Dia. Shank Powder Drive Pins Model No. Pin Length Shank Dia. (in.) (in.) Quantity Pack Carton Simpson Strong-Tie Tools PDPA-50 PDPA-50K PDPA-62K PDPA-75 PDPA-100 PDPA-106 PDPA-125 PDPA-131 PDPA-150 PDPA-187 PDPA-200 PDPA-250 PDPA-250MG PDPA-287 PDPA-287MG 1/2 1/2 knurled 5/8 knurled 3/4 1 1 1/16 1 1/4 1 5/16 1 1/2 1 7/8 2 2 1/2 2 1/2 2 7/8 2 7/8 0.157 PTP-27L 100 1,000 PT-27 PT-22A PT-22HA Note: The PDPA-250MG and PDPD-287MG models have mechanically galvanized (Class 65) finish. PDPA PDPAWL -- 0.300"-Dia. Head with 0.157"-Dia. Shank Powder Drive Pins with 1" Washer Model No. Pin Length Shank Dia. (in.) (in.) Quantity Pack Carton Simpson Strong-Tie Tools PDPAWL-50K PDPAWL-75 PDPAWL-100 PDPAWL-125 PDPAWL-150 PDPAWL-187 PDPAWL-200 PDPAWL-200MG PDPAWL-225 PDPAWL-250 PDPAWL-250MG PDPAWL-287 PDPAWL-287MG 1/2 knurled 3/4 1 1 1/4 1 1/2 1 7/8 2 2 2 1/4 2 1/2 2 1/2 2 7/8 2 7/8 0.157 PTP-27L 100 1,000 PT-27 PT-22A PT-22HA Note: The PDPAWL-200MG, PDPAWL-250MG and PDPAWL-287MG models have mechanically galvanized (Class 65) finish. PDPAWL 132 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Fasteners for Powder-Actuated Tools PDPAS -- 0.300"-Dia. Head with 0.157"-Dia. Shank Powder Drive Pins (10-Pin Collation) Model No. Pin Length Shank Dia. (in.) (in.) Quantity Pack Carton Simpson Strong-Tie Tools PDPAS-50K 1/2 knurled PDPAS-62K 5/8 knurled PDPAS-75 3/4 PDPAS-100 1 PDPAS-125 1 1/4 0.157 100 1,000 -- PDPAS-150 1 1/2 PDPAS-187 1 7/8 PDPAS-200 2 PDPAS-250 2 1/2 PDPAS-287 2 7/8 PDPAT -- 0.300"-Dia. Head with 0.157"-Dia. Shank Powder Drive Pins with Top Hat Model No. Pin Length Shank Dia. (in.) (in.) Quantity Pack Carton Simpson Strong-Tie Tools PDPAT-50K PDPAT-62KP PDPAT-75 PDPAT-100 1/2 knurled 5/8 knurled 3/4 1 0.157 100 1,000 PTP-27L PT-27 PT-22A PT-22HA Note: PDPAT-62KP is a point protrusion pin. The point of the pin is designed to slightly protrude from the tool to aid in hole location. Pre-Assembled Ceiling Clips -- 0.300"-Dia. Head with 0.157"-Dia. Shank Powder Drive Pins Model No. Pin Length (in.) Shank Dia. (in.) Description Quantity Pack Carton Simpson Strong-Tie Tools 90° 14 ga. PCL -- -- ceiling clip angle 100 1,000 -- (no pin) PCLDPA-87 PCLDPA-106 PCLDPA-131 7/8 90° 14 ga. 11/16 0.157 ceiling clip angle with pin 1 5/16 PECLDPA-106 11/16 120° 14 ga. 0.157 ceiling clip angle PECLDPA-131 15/16 with pin 100 1,000 100 1,000 PTP-27L PT-27 PT-22A PT-22HA S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. PDPAS PDPAT PCL PCLDPA PECLDPA 133 Direct Fastening Solutions Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Fasteners for Powder-Actuated Tools Threaded Rod Hangers -- 0.300"-Dia. Head with 0.157"-Dia. Shank Powder Drive Pins Model No. Pin Length (in.) Shank Dia. (in.) Thread Rod Hanger Size (Clip Gauge) Quantity Simpson Strong-Tie Pack Carton Tools PTRHA4-131 15/16 0.157 PTRHA3-131 1/4" 20 (14 ga.) 3/8" 16 (14 ga.) PTP-27L 50 500 PT-27 PT-22A PT-22HA PTRHA3 Insulation Board Attachment -- 0.300"-Dia. Head with 0.145"-Dia. Shank Powder Drive Pins with 1 7/16" Metal Washers Model No. Pin Length (in.) Shank Dia. (in.) Description Quantity Simpson Strong-Tie Pack Carton Tools PINW-150 11/2 PINW-200 PINW-250 2 Pin with 0.145 17/16" metal 2 1/2 washer 50 PTP-27L 500 PT-27 PT-22A PT-22HA PINW-300 3 PINW Insulation Board Attachment -- 0.300"-Dia. Head with 0.145"-Dia. Shank Powder Drive Pins with 1 3/8" Plastic Washers Model No. Pin Length (in.) Shank Dia. (in.) Description Quantity Simpson Strong-Tie Pack Carton Tools PINWP-150W 11/2 PINWP-175W 13/4 Pin with PINWP-200W 2 0.145 13/8" white 50 plastic washer PINWP-250W 21/2 PTP-27L 500 PT-27 PT-22A PT-22HA PINWP-300W 3 PINWP 134 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Fasteners for Powder-Actuated Tools Pre-Assembled Highway Basket Clips -- 0.300"-Dia. Head with 0.145"-Dia. Shank Powder Drive Pins Model No. Pin Length (in.) Shank Dia. (in.) Description Quantity Simpson Strong-Tie Pack Carton Tools PHBC-150 PHBC-200 PHBC-250 1 1/2 14 ga. 100 1,000 PTP-27L 2 0.145 highway basket attachment PT-27 PT-22A with pin PT-22HA 2 1/2 50 500 PHBC Pre-Assembled BX Cable and Conduit Straps -- 0.300"-Dia. Head with 0.145"-Dia. Shank Powder Drive Pins Model No. Pin Length (in.) Shank Dia. (in.) Description Quantity Simpson Strong-Tie Pack Carton Tools PBXDP-100 1 0.145 BX cable strap with pin 100 1,000 PCC50-DP100 PCC75-DP100 1/2" EMT conduit clip with pin 100 1,000 PTP-27L PT-27 PT-22A 1 0.145 3/4" EMT conduit clip with pin 50 500 PT-22HA PCC100-DP100 1" EMT conduit clip with pin 50 500 PBXDP PCC 3/8" 16 x 1 1/4" Threaded Studs Model No. Pin Shank Shank Length Dia. (in.) (in.) Description Quantity Simpson Strong-Tie Pack Carton Tools PSLV3-12575K 3/4 knurled 3/8"16 x 11/4" PSLV3-125100 1 0.205 threaded stud 100 1,000 -- length PSLV3-125125* 11/4 *Indicates Factory Mutual Listing 3031724. PSLV3 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 135 Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Fasteners for Powder-Actuated Tools Concrete Forming Pin -- 0.187"-Dia. Head with 0.145"-Dia. Shank Powder Drive Pins Model No. Pin Length Shank Dia. (in.) (in.) Quantity Pack Carton Simpson Strong-Tie Tools PKP-250 2-7/16 0.145 100 1,000 PTP-27L PT-27 PT-22A PT-22HA PKP Miscellaneous Hammer Drive Pin -- 0.250"-Dia. Head with 0.140"-Dia. Shank Powder Drive Pins with 3/8" Metal Washer Model No. Pin Length Shank Dia. (in.) (in.) Quantity Pack Carton Simpson Strong-Tie Tools PHD-75 3/4 PHD-100 1 0.140 100 1,000 PHT-38 PHD-125 1 1/4 PHD Manual Hammer Tool (not for use with powder loads) PHT-38 Warning: Do not use powder loads with this tool. This is a hammer drive tool only. Use of powder loads with this tool may result in injury or death. 136 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Direct Fastening Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Important Information Powder-Actuated Fastening Systems Gas- and Powder-Actuated Fastening Safety Principles Before operating any Simpson Strong-Tie gas- or powder-actuated tool, you must read and understand the Operator's Manual and be trained by an authorized instructor in the operation of the tool. Simpson Strong-Tie highly recommends you read and fully understand the safety guidelines of the tool you use. You must then pass a test and receive a certified operator card to become a Certified Operator. The test and Operator's Manual are included with each tool kit, or certification can be obtained by taking the test online at strongtie.com. GENERAL SAFETY To avoid serious injury or death: · ALWAYS make sure that the operator and bystanders wear safety glasses. Hearing and head protection are also recommended. · ALWAYS post warning signs when gas- or powder-actuated tools are in use. Signs should state "Tool in Use" and should be posted within the area where the tool is being used. · ALWAYS store gas- or powderactuated tools unloaded. Tools, loads and gas cells should be stored in a locked container out of the reach of children. · NEVER place any part of your body over the front muzzle of the tool even if no fastener is present. The fastener, pin or tool piston can cause serious injury or death in the event of an accidental discharge. · NEVER transport fasteners or other hard objects in the same pocket or container with powder loads or fuel cells. These objects may strike the powder loads or puncture the fuel cell, thereby setting them off and causing serious injury or death. · NEVER attempt to bypass or circumvent any of the safety features on a gas- or powder-actuated tool. · ALWAYS keep the tool pointed in a safe direction. · ALWAYS keep your finger off the trigger until ready to shoot. · ALWAYS keep the tool unloaded until ready to use. INSTALLATION SAFETY To avoid serious injury or death: · ALWAYS hold the tool perpendicular (90°) to the fastening surface to prevent ricocheting fasteners. Use the spall guard whenever possible. · NEVER attempt to fasten to soft, thin, brittle or very hard materials such as drywall, light gauge steel, glass, tile or cast iron as these materials are inappropriate. Conduct a pre-punch test to determine base material adequacy. · NEVER attempt to fasten to soft material like wood or drywall (fastening through soft materials into an appropriate base material may be allowed if the application is appropriate). · NEVER attempt to fasten to a spalled, cracked or uneven surface. Safety equipment, such as safety glasses and ear plugs, is recommended when using gas- or powder-actuated tools. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 137 Restoration Solutions Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-SLV Super-Low-Viscosity Injection Epoxy CI-SLV super-low-viscosity structural injection epoxy is a two-component, high-modulus, high-solids, moisture-tolerant epoxy specially designed for pressure injection, gravity feeding and flood coat filling of concrete cracks when substrate temperatures are between 60°F (16°C) to 90°F (32°C). Available in 3-gallon bulk kits or convenient side-by-side cartridges dispensed through a static mixing nozzle using either a manual or pneumatic dispensing tool. Features · Chemically bonds with the concrete to provide a structural repair. CI-SLV seals the crack from moisture, protecting rebar in the concrete from corrosion. · Moisture-tolerant, can be used on dry and damp surfaces · Low surface tension allows the material to effectively penetrate narrow cracks · Formulated for maximum penetration under pressure · Non-shrink and resistant to oils, salts and mild chemicals · Can be used with metered pressure-injection equipment · Freeze-thaw resistant Applications · Pressure injection · Gravity feed · Underwater pressure injection · Flood coat CI-SLV Product Information Mix Ratio/Type 2:1 Mixed Color Clear Crack Width 0.002" 0.25" (0.05 mm 6 mm) Shelf Life 24 months Storage Temperature 45°F (7°C) 90°F (32°C) Volatile Organic Compound (VOC) 8 g/L mixed Yield 231 in.3/US gal. (0.001 m3/L) For Flood-Coat Applications 150 200 ft.2/US gal. (3.7 4.9 m2/L) depending on surface profile and porosity Pot Life, 1 Quart 6 minutes at 90°F (32°C) 25 minutes at 72°F (22°C) Thin Film (5 mil) Cure Time at 72°F, ASTM D5895 Set to touch: 4 hrs. Dry through: 9 hrs. Manufactured in the USA using global materials 140 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-SLV Super-Low-Viscosity Injection Epoxy Code Reports, Standards and Compliance ASTM C881 and AASHTO M235 Type I/IV; Grade 1; Class C Installation Instructions Installation instructions are located on pp. 157165 and on the CI-SLV Technical Data Sheet at strongtie.com/rps. CI-SLV Packaging Information Model No. Capacity Packaging Package Carton (ounces) Type Quantity Quantity Dispensing Tools Mixing Nozzle CISLV321 32 Side-by-side cartridge 1 5 ADT30S, ADT30P EMN022 CISLV3KT 384 3 gallon bulk kit 1 case of (3) gallon cans -- Metering pumps offered by third-party manufacturers -- 1. One EMN022 mixing nozzle supplied with each cartridge. 2. Cartridge estimation guidelines are available at strongtie.com/apps. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 141 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-LV Low-Viscosity Injection Epoxy Restoration Solutions CI-LV low-viscosity structural injection epoxy is a two-component, high-modulus, high-solids, moisture-tolerant epoxy specially designed for pressure injection, gravity feeding and flood coat filling of concrete cracks and for increasing the bond between freshly placed repair mortars or concrete mixes and existing concrete when substrate temperatures are between 40°F (4°C) to 90°F (32°C). Available in 3-gallon bulk kits or convenient side-by-side cartridges dispensed through a static mixing nozzle using either a manual or pneumatic dispensing tool. Features · Chemically bonds with the concrete to provide a structural repair. CI-LV seals the crack from moisture, protecting rebar in the concrete from corrosion. · Approved under NSF/ANSI Standard 61 (568 in.2 /1,000 gal.) · Moisture-tolerant, can be used on dry and damp surfaces · Low surface tension allows the material to effectively penetrate narrow cracks · Formulated for maximum penetration under pressure · Non-shrink and resistant to oils, salts and mild chemicals · Can be used with metered pressure-injection equipment · Freeze-thaw resistant Applications · Pressure injection · Gravity feed · Repair mortar · Underwater pressure injection · Flood coat · Bonding agent Product Information CI-LV Mix Ratio/Type 2:1 Mixed Color Dark amber Crack Width 0.002" 0.25" (0.05 mm 6 mm) Shelf Life 24 months Storage Temperature 45°F (7°C) 90°F (32°C) Base Material Temperature 40°F (4°C) 90°F (32°C) Volatile Organic Compound (VOC) 2 g/L mixed Yield 231 in.3/US gal. (0.001 m3/L) For Flood-Coat Applications 150 200 ft.2/US gal. (3.7 4.9 m2/L) depending on surface profile and porosity Pot Life, 1 Quart 10 minutes at 90°F (32°C) 25 minutes at 72°F (22°C) 100 minutes at 50°F (10°C) Thin Film (5 mil) Cure Time at 72°F, ASTM D5895 Set to touch: 3 hrs. 50 min. Dry through: 6 hrs. 15 min. Manufactured in the USA using global materials 142 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-LV Low-Viscosity Injection Epoxy Code Reports, Standards and Compliance ASTM C881 and AASHTO M235 Type I/II; Grade 1; Class B, Type I/IV and II/V, Grade 1, Class C NSF/ANSI/CAN 61 (216 in.2 / 1,000 gal.) Installation Instructions Installation instructions are located on pp. 157165 and on the CI-LV Technical Data Sheet at strongtie.com/rps. CI-LV Packaging Information Model No. Capacity Packaging Package Carton (ounces) Type Quantity Quantity Dispensing Tools Mixing Nozzle CILV321 32 Side-by-side cartridge 1 5 ADT30S, ADT30P EMN022 CILV3KT 384 3 gallon bulk kit 1 case of (3) gallon cans -- Metering pumps offered by third-party manufacturers -- 1. One EMN022 mixing nozzle supplied with each cartridge. 2. Cartridge estimation guidelines are available at strongtie.com/apps. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 143 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-LV FS Low-Viscosity Fast-Setting Injection Epoxy Restoration Solutions CI-LV FS fast-setting low-viscosity structural injection epoxy is a two-component, high-modulus, high-solids, moisture-tolerant epoxy specially designed for pressure injection of concrete cracks and for increasing the bond between freshly placed repair mortars or concrete mixes and existing concrete when substrate temperatures are between 40°F (4°C) to 90°F (32°C). Available in 3-gallon bulk kits or convenient side-by-side cartridges dispensed through a static mixing nozzle using either a manual, battery-powered or pneumatic dispensing tool. Features · Chemically bonds with the concrete to provide a structural repair. CI-LV FS seals the crack from moisture, protecting rebar in the concrete from corrosion. · Moisture-tolerant, can be used on dry and damp surfaces · Low surface tension allows the material to effectively penetrate narrow cracks · Formulated for maximum penetration under pressure · Non-shrink and resistant to oils, salts and mild chemicals · Can be used with metered pressure-injection equipment · Freeze-thaw resistant Applications · Pressure injection · Gravity feed · Bonding agent · Underwater pressure injection · Flood coat CI-LV FS Product Information Mix Ratio/Type 2:1 Mixed Color Amber Crack Width 0.016" 0.25" (0.4 mm 6 mm) Shelf Life 24 months Storage Temperature 45°F (7°C) 90°F (32°C) Base Material Temperature 40°F (4°C) 90°F (32°C) Volatile Organic Compound (VOC) Yield For Flood-Coat Applications 13 g/L mixed 231 in.3/US gal. (0.001 m3/L) 150 200 ft.2/US gal. (3.7 4.9 m2/L) depending on surface profile and porosity Pot Life, 1 Quart 10 minutes at 72°F (22°C) 28 minutes at 50°F (10°C) Thin Film (5 mil) Cure Time at 72°F, ASTM D5895 Set to touch: 1 hr. 45 min. Dry through: 4 hrs. Manufactured in the USA using global materials 144 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-LV FS Low-Viscosity Fast-Setting Injection Epoxy Code Reports, Standards and Compliance ASTM C881 and AASHTO M235 Type I/II; Grade 1; Class B, Type I/IV and II/V, Grade 1, Class C Installation Instructions Installation instructions are located on pp. 157165 and on the CI-LV FS Technical Data Sheet at strongtie.com/rps. CI-LV FS Packaging Information Model No. Capacity Packaging Package Carton (ounces) Type Quantity Quantity Dispensing Tools Mixing Nozzle CILVFS321 32 Side-by-side cartridge 1 5 ADT30S, ADT30P EMN022 CILVFS3KT 384 3 gallon bulk kit 1 case of (3) gallon cans -- Metering pumps offered by third-party manufacturers -- 1. One EMN022 mixing nozzle supplied with each cartridge. 2. Cartridge estimation guidelines are available at strongtie.com/apps. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 145 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-LPL Low-Viscosity Long-Pot-Life Injection Epoxy Restoration Solutions CI-LPL long-pot-life structural injection epoxy is a two-component, high-modulus, high-solids, moisture-tolerant epoxy specially designed for pressure injection, gravity feeding and flood coat filling of concrete cracks when substrate temperatures are between 60°F (16°C) to 110°F (43°C). Available in 3-gallon bulk kits or convenient side-by-side cartridges dispensed through a static mixing nozzle using either a manual or pneumatic dispensing tool. Features · Chemically bonds with the concrete to provide a structural repair. CI-LPL seals the crack from moisture, protecting rebar in the concrete from corrosion. · Moisture-tolerant, can be used on dry and damp surfaces · Formulated for use in hot environments to 110°F · Low surface tension allows the material to effectively penetrate narrow cracks · Formulated for maximum penetration under pressure · Non-shrink and resistant to oils, salts and mild chemicals · Can be used with metered pressure-injection equipment · Freeze-thaw resistant Applications · Pressure injection · Gravity feed · Underwater pressure injection CI-LPL Product Information Mix Ratio/Type 2:1 Mixed Color Amber Crack Width 0.016" 0.25" (0.4 mm 6 mm) Shelf Life 24 months Storage Temperature 45°F (7°C) 90°F (32°C) Base Material Temperature 60°F (16°C) 110°F (43°C) Volatile Organic Compound (VOC) < 1 g/L mixed Yield 231 in.3/US gal. (0.001 m3/L) For Flood-Coat Applications 150 200 ft.2/US gal. (3.7 4.9 m2/L) depending on surface profile and porosity Pot Life, 1 Quart 20 minutes at 90°F (32°C) 60 minutes at 72°F (22°C) Thin Film (5 mil) Cure Time at 72°F, ASTM D5895 Set to touch: 6 hrs. 30 min. Dry through: 16 hrs. 30 min. Thin Film (5 mil) Cure Time at 95°F, ASTM D5895 Set to touch: 3 hrs. Dry through: 4 hrs. Manufactured in the USA using global materials 146 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-LPL Low-Viscosity Long-Pot-Life Injection Epoxy Code Reports, Standards and Compliance ASTM C881 and AASHTO M235 Type I/IV; Grade 1; Class C Installation Instructions Installation instructions are located on pp. 157165 and on the CI-LPL Technical Data Sheet at strongtie.com/rps. CI-LPL Packaging Information Model No. Capacity Packaging Package Carton (ounces) Type Quantity Quantity Dispensing Tools Mixing Nozzle CILPL321 32 Side-by-side cartridge 1 5 ADT30S, ADT30P EMN022 CILPL3KT 384 3 gallon bulk kit 1 case of (3) gallon cans -- Metering pumps offered by third-party manufacturers -- 1. One EMN022 mixing nozzle supplied with each cartridge. 2. Cartridge estimation guidelines are available at strongtie.com/apps. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 147 Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-GV Gel-Viscosity Injection Epoxy CI-GV structural injection epoxy gel is a two-component, high-modulus, high-solids, moisture-tolerant, thixotropic epoxy designed for pressure injection of concrete cracks. CI-GV is suitable for vertical and horizontal crack sealing and general concrete repair applications when substrate temperatures are between 40°F (4°C) to 90°F (32°C). Available in 3-gallon bulk kits or convenient side-by-side cartridges dispensed through a static mixing nozzle using either a manual or pneumatic dispensing tool. Features · Chemically bonds with the concrete to provide a structural repair. CI-GV seals the crack from moisture, protecting rebar in the concrete from corrosion. · Gel-viscosity moisture-tolerant, can be used on dry and damp surfaces · Formulated for maximum penetration under pressure · Non-shrink and resistant to oils, salts and mild chemicals · Can be used with metered pressure-injection equipment · Freeze-thaw resistant Applications · Pressure injection · Repair mortar · Pick proof sealant · Underwater pressure injection · Bonding agent CI-GV Product Information Mix Ratio/Type 2:1 Mixed Color Concrete gray Crack Width 0.094" 0.25" (2.4 mm 6 mm) Shelf Life 24 months Storage Temperature 45°F (7°C) 90°F (32°C) Base Material Temperature 40°F (4°C) 90°F (32°C) Volatile Organic Compound (VOC) 10 g/L mixed Yield 231 in.3/US gal. (0.001 m3/L) Pot Life, 1 Quart 8 minutes at 90°F (32°C) 19 minutes at 72°F (22°C) 55 minutes at 50°F (10°C) Thin Film (5 mil) Cure Time at 72°F, ASTM D5895 Set to touch: 3 hrs. Dry through: 6 hrs. Manufactured in the USA using global materials 148 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CI-GV Gel-Viscosity Injection Epoxy Code Reports, Standards and Compliance ASTM C881 and AASHTO M235 Type I/II; Grade 3; Class B, Type I/IV and II/V, Grade 3, Class C Installation Instructions Installation instructions are located on pp. 157165 and on the CI-GV Technical Data Sheet at strongtie.com/rps. CI-GV Packaging Information Model No. Capacity Packaging Package Carton (ounces) Type Quantity Quantity Dispensing Tools Mixing Nozzle CIGV321 32 Side-by-side cartridge 1 5 ADT30S, ADT30P EMN022 CIGV3KT 384 3 gallon bulk kit 1 case of (3) gallon cans -- Metering pumps offered by third-party manufacturers -- 1. One EMNO22 mixing nozzle supplied with each cartridge. 2. Cartridge estimation guidelines are available at strongtie.com/apps. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 149 Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack-Pac® Injection Epoxy The Crack-Pac injection epoxy is designed to repair cracks in concrete ranging from 1/64" to 1/4" wide in concrete walls, floors, slabs, columns and beams. The mixed adhesive has the viscosity of a light oil and a low surface tension, allowing it to penetrate fine to medium-width cracks in dry, damp or wet conditions with excellent results. Resin is contained in the cartridge and hardener is contained in the nozzle. Features · Dispenses with a standard caulking tool, no special dispensing tool needed · Clean and easy to mix · Seals out moisture, protecting rebar in the concrete from corrosion and flooring from moisture damage · Chemically bonds with the concrete to restore strength · Non-shrink material resistant to oils, salts and mild chemicals · Meets the requirements of AASHTO M235 and ASTM C881, Type I, Grade 1, Class C Application Considerations · Suitable for repair of cracks ranging from 1/64" to 1/4" wide in concrete walls, floors, slabs, columns and beams. · Can be used to inject cracks in dry, damp or wet conditions with excellent results. Not for use in actively leaking cracks. · In order for components to mix properly, the resin and hardener must be conditioned to 60°F (16°C) to 80°F (27°C) before mixing. Shelf Life 24 months from date of manufacture, when stored between 45°F (7°C) and 90°F (32°C) in unopened cartridge. Base Material Temperature 60°F (16°C) to 90°F (32°C). Crack-Pac Injection Epoxy (ETIPAC10) Installation Instructions Installation instructions are located on pp. 157165. 150 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack-Pac® Injection Epoxy Crack-Pac Kit (ETIPAC10KT) Crack-Pac injection epoxy is also available in the Crack-Pac Injection Kit (ETIPAC10KT). The kit includes everything needed to pressure inject cracks. · 2 Crack-Pac cartridge/nozzle sets (ETIPAC10) · 12 E-Z-ClickTM injection ports · 2 E-Z-Click injection fittings with 12" tubing · 1 pint of ETR paste-over epoxy (8 oz. of resin + 8 oz. of hardener) · 4 disposable wood paste-over applicators · 1 pair latex gloves Crack-Pac Cartridge System Model No. Capacity (ounces) Cartridge Type ETIPAC10 9 Single ETIPAC10KT 18 Single Carton Quantity 12 2 (kits) Dispensing Tool CDT10S Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 151 Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack-Pac® Flex-H2OTM Polyurethane Crack Sealer The Crack-Pac Flex-H2O polyurethane injection resin seals leaking cracks, voids or fractures from 1/32" to 1/4" wide in concrete or solid masonry. Designed to perform in applications where water is seeping or mildly leaking from the crack, the polyurethane is packaged in the cartridge and an accelerator is packaged in the nozzle. When the resin encounters water as it is injected into the crack, it becomes an expanding foam that provides a flexible seal in leaking and non-leaking cracks. Features · Can be dispensed with a standard caulking tool · Can also be used on dry cracks if water is introduced to affected area · Can be used with a reduced amount or without accelerator to slow down reaction time · Expands to fill voids and seal the affected area · Fast reacting -- reaction begins within 1 minute after exposure to moisture; expansion may be completed within 3 minutes (depending on the amount of moisture and the ambient temperature) · 20:1 expansion ratio (unrestricted rise) means less material needed Application Considerations · Suitable for sealing cracks ranging from 1/32" to 1/4" wide in concrete and solid masonry. · Suitable for repair of cracks in dry, damp and wet conditions with excellent results. Designed to perform in applications where water is seeping or mildly leaking from the crack. · In order for components to mix properly, the resin and hardener must be conditioned to 60°F (16°C) to 90°F (32°C) before mixing. Shelf Life 12 months from the date of manufacture, when stored between 45°F (7°C) and 90°F (32°C) in unopened cartridge. Product is very moisture sensitive. Base Material Temperature 60°F (16°C) to 90°F (32°C). Installation Instructions Installation instructions are located on pp. 157165. Crack-Pac Flex-H2O Crack Sealer (CPFH09) 152 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack-Pac® Flex-H2OTM Polyurethane Crack Sealer Crack-Pac Flex-H2O Kit (CPFH09KT) Crack-Pac Flex-H2O injection epoxy is also available in the Crack-Pac Flex-H2O Injection Kit (CPFH09KT). The kit includes everything needed to pressure inject cracks. · 2 Crack-Pac Flex-H2O cartridge / nozzle sets (CPFH09) · 12 E-Z-ClickTM injection ports · 2 E-Z-Click injection fittings with 12" tubing · 1 pint of ETR paste-over epoxy (8 oz. of resin + 8 oz. of hardener) · 4 disposable wood paste-over applicators · 1 pair latex gloves Crack-Pac Flex-H2O Packaging Model No. Capacity Cartridge Type Carton Quantity Dispensing Tool CPFH09 CPFH09KT 9 ounces 18 ounces Single Single 12 2 (kits) CDT10S 5 gallons resin FH051 Pail 1 -- 16 ounces catalyst 1. For standard reaction time, use 30:1 resin to catalyst ration. For a faster reaction time, add more catalyst; for a slower reaction time, use less. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 153 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CIP / ETR Paste-Over and Crack Sealants CIP and ETR are fast-curing epoxy used to paste-over and seal cracks while securing injection ports to the surface of concrete substrates prior to injecting an epoxy or urethane crack repair product. When properly mixed, the products will be a uniform gray color and can be left in place or removed after the repair is complete. Features · 1:1 two component, high solids, epoxy amine based adhesive · Non-sag paste consistency for horizontal, vertical or overhead applications · Manufactured in the USA using global materials CIP-LO Low Odor Paste-Over Epoxy and Crack Sealant · Low odor formulation · Strong substrate bond; requires chipping to remove · Gel Time -- 6 minutes at 72°F (22°C), 28 minutes at 40°F (4°C) · Cure Time -- 75 minutes at 72°F (22°C), 2 hours at 60°F (16°C) and 45 hours at 40°F (4°C) · Volatile organic compound (VOC) -- 4 g/L CIP-F Flexible Paste-Over Adhesive and Crack Sealant · Remains flexible after cure for easier removal · Moderate substrate bond; peels away for removal · Gel Time -- 4 minutes at 72°F (22°C), 9 minutes at 40°F (4°C) · Cure Time -- 1 hour at 72°F (22°C), and 3 hours at 40°F (4°C) · Volatile organic compound (VOC) -- 0 g/L CIP-LO Restoration Solutions 154 CIP-F S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CIP / ETR Paste-Over and Crack Sealants ETR Concrete Repair and Paste-Over Epoxy · Canisters are mixed manually and do not require dispensing tool · Each package contains enough material to cover approximately eight lineal feet of cracks · Gel Time -- 6 minutes at 72°F (22°C), 10 minutes at 40°F (4°C) · Cure Time -- 1 hour at 72°F (22°C), 2 hours at 60°F (16°C) · Volatile organic compound (VOC) -- 7 g/L · Available in two 8 fl. oz. canisters ETR16 Application Considerations · Apply to concrete 40°F (4°C) or above. For best results, warm material to 65°F (16°C) or above prior to application. Shelf Life 24 months from date of manufacture, unopened for CIP-LO and ETR; 12 months from date of manufacture, unopened for CIP-F. Storage Conditions For best results, store between 45°F (7°C) and 90°F (32°C) for CIP-LO and ETR; 60°F (16°C) 95°F (35°C) for CIP-F. Installation Instructions Installation instructions are located on pp. 157160. Paste-Over and Crack Sealants Model No. Capacity (oz.) Cartridge Mixing Nozzle Dispensing Package Carton Tool Quantity Quantity CIPLO221 22 Side-by-side EMN22I 1 10 EDT22S, EDTA22CKT, CIP-F222 EDTA22P 22 Side-by-side EMNCIPF22 1 10 ETR16 16 -- -- -- 1. One EMN22I mixing nozzle supplied with each cartridge. 2. One EMNCIPF22 mixing nozzle supplied with each cartridge. 1 4 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 155 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Repair Accessories Mixing Nozzles Model No. EMNCIPF22-RP5 EMN022 Optimix® Mixing Nozzle Description Mixing nozzle for CIPF-22 epoxy Package Quantity 5 Carton Quantity 5 EMN022-RP6 Optimix mixing nozzle for epoxies 6 5 1. Use only appropriate Simpson Strong-Tie mixing nozzle in accordance with Simpson Strong-Tie instructions. Modification or improper use of mixing nozzle may impair epoxy performance. 2. Includes retaining nuts. Restoration Solutions E-Z-ClickTM Ports and Injection Fitting Injection Ports and Injection Fittings EIPX-EZ Corner-Mount / Drilled-In Port EIP-EZA Flush-Mount Port Model No. Description Hole Package Contents Size (in.) Ports E-Z-Click Injection Fitting Carton Quantity EIP-EZAKT -- 20 1 5 kits E-Z-Click flush-mount injection ports EIP-EZA -- 1 each -- 100 EIPX-EZKT 20 E-Z-Click corner mount or drill in injection port 5/8 EIPX-EZ-RP20 20 1 5 kits -- 5 packs of 20 EIF-EZ E-Z-Click injection fitting -- -- 1 each 10 1. EIPX intended for use as a surface-mount port in corners and as a drilled-in port on flat surfaces. Detailed information on the full line of Simpson Strong-Tie manual, battery and pneumatic dispensing tools can be found on pp. 2829 and is available on strongtie.com. 156 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Important: These instructions are intended as recommended guidelines. Due to the variability of field conditions, selection of the proper material for the intended application and installation is the sole responsibility of the applicator. Epoxy injection is an economical method of repairing non-moving cracks in concrete walls, slabs, columns and piers and is capable of restoring the concrete to its pre-cracked strength. Prior to doing any injection it is necessary to determine the cause of the crack. If the source of cracking has not been determined and remedied, the concrete may crack again. Materials · CI-LV and CI-SLV for repair of hairline cracks (0.002") and those up to 1/4" in width. · CI-LV FS and CI-LPL for repair of fine to medium-width cracks (suggested width range: 1/64"1/4"). · CI-GV for repair of medium-width cracks (suggested width range: 3/32"1/4"). · Crack-Pac® injection epoxy for repair of fine to medium non-structural cracks (suggested width range: 1/64"1/4"). · Crack-Pac Flex-H2OTM polyurethane crack sealer for repair of fine- to medium-width non-structural cracks (suggested width range: 1/32"1/4"). · CIP-LO, CIP-F and ETR are recommended for paste-over of crack surface and installation of injection ports. ET-HP may also be used as a substitute. · E-Z-ClickTM injection ports, fittings and other suitable accessories. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 157 Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Estimating Guide for Epoxy Crack Injection Width of Crack (in.) Concrete Thickness (in.) CI-SLV, CI-LV, CI-LV FS, CI-LPL, CI-GV Approx. Coverage per 32 oz. Cartridge (linear ft.) ETI-LV, ETI-GV Approx. Coverage per 22 oz. Cartridge (linear ft.) ETI-SLV Approx. Coverage per 16.5 oz. Cartridge (linear ft.) Crack-Pac Approx. Coverage per 9 oz. Cartridge (linear ft.) Crack-Pac Flex-H2O Approx. Coverage per 9 oz. Cartridge (linear ft.) 4 69.4 47.7 35.7 18.4 -- 6 46.3 31.8 23.8 12.3 -- 1/64 8 34.6 23.8 17.9 9.2 -- 10 27.8 19.1 14.3 7.4 -- 4 34.6 23.8 17.9 9.2 108.0 6 23.1 15.9 11.9 6.1 72.0 1/32 8 17.3 11.9 8.9 4.6 54.0 10 13.8 9.5 7.1 4 17.3 11.9 8.9 6 11.5 7.9 6.0 1/16 8 8.7 6.0 4.5 10 7.0 4.8 3.6 3.7 43.2 4.6 54.0 3.1 36.0 2.3 27.0 1.8 21.6 4 8.7 6.0 4.5 2.3 27.0 6 5.8 4.0 3.0 1.5 18.0 1/8 8 4.4 3.0 2.2 1.2 13.5 10 3.5 2.4 1.8 0.9 10.8 4 5.8 4.0 3.0 1.5 18.0 6 3.8 2.6 2.0 1.0 12.0 3/16 8 2.9 2.0 1.5 0.8 9.0 10 2.3 1.6 1.2 0.6 7.2 4 4.4 3.0 2.2 1.2 13.5 6 2.9 2.0 1.5 1.8 9.0 1/4 8 2.2 1.5 1.1 0.6 6.8 10 1.7 1.2 0.9 0.5 5.4 Coverage listed is approximate and will vary depending on waste and condition of concrete. 158 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Preparation of the Crack for Injection Clean the crack and the surface surrounding it to allow the paste-over to bond to sound concrete. At a minimum, the surface to receive paste-over should be brushed with a wire brush. Oil, grease or other surface contaminant must be removed in order to allow the paste-over to bond properly. Take care not to impact any debris into the crack during cleaning. Using clean, oil-free compressed air, blow out the crack to remove any dust, debris or standing water. Best results will be obtained if the crack is dry at the time of injection. If water is continually seeping from the crack, the flow must be stopped in order for epoxy injection to yield a suitable repair. Other materials such as polyurethane resins may be required to repair an actively leaking crack. For many applications, additional preparation is necessary in order to seal the crack. Where a surfacing material has been removed using an acid or chemical solvent, prepare the crack as follows: 1. Using clean, compressed air, blow out any remaining debris and liquid. 2. Remove residue by high-pressure washing or steam cleaning. 3. Blow any remaining water from the crack with clean compressed air. If a coating, sealant or paint has been applied to the concrete, it must be removed before placing the paste-over epoxy. Under the pressure of injection, these materials may lift and cause a leak. If the surface coating is covering the crack, it may be necessary to route out the opening of the crack in a "V" shape using a grinder in order to get past the surface contamination. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 159 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Sealing of the Crack and Attachment of E-Z-ClickTM Injection Ports 1. To adhere the port to the concrete, apply a small amount of paste-over around the bottom of the port base. Place the port at one end of the crack and repeat until the entire crack is ported. As a rule of thumb, injection ports should be placed 8" apart along the length of the crack. Important: Do not allow paste-over to block the port or the crack under it, this is where epoxy must enter the crack. 1. 1.1 Restoration Solutions 2. Using a putty knife or other paste-over tool, generously work paste-over along the entire length of the crack. Take care to mound the paste-over around the base of the port to approximately 1/4" thick extending 1" out from the base of the port and to work out any holes in the material. It is recommended that the paste-over should be a minimum of 3/16" thick and 1" wide along the crack. Insufficient paste-over will result in leaks under the pressure of injection. If the crack passes completely through the concrete element, seal the back of the crack, if possible. If not, injection epoxy may be able to run out the backside of the crack, resulting in an ineffective repair. 2. 3. Allow the paste-over to harden before beginning injection. Note: CIP-LO and ETR are a fast cure and when manually mixed may harden prematurely if left in a mixed mass on the mixing surface while installing ports. Spreading paste-over into a thin film (approximately 1/8") on the mixing surface will slow curing by allowing the heat from the reaction to dissipate. 160 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Injection Procedure for CI-SLV, CI-LV, CI-LV FS, CI-LPL, CI-GV and Crack-Pac® Injection Epoxy 1. Follow cartridge preparation instructions on the cartridge label. Verify the material flowing from the Opti-Mix® mixing nozzle is a uniform and consistent color. 2. Attach the E-Z-ClickTM fitting to the end of the nozzle by pushing the tubing over the barbs at the end of the nozzle. Make sure that all ports are pushed in to the open position. 3. Attach the E-Z-Click injection fitting to the first E-Z-Click port until it clicks into 3. place. Make sure that the heads of all the ports are pushed in to the open position. In vertical applications, begin injection at the lowest port and work your way up. In a horizontal application start at one end of the crack and work your way to the other end. 4. Inject epoxy into the first port until it will no longer flow into the crack. If epoxy shows at the next port and the first port still accepts material, close the second port and continue to inject into the first 4. port until it accepts no more epoxy. Continue closing ports where epoxy appears until the first port refuses epoxy. When the first port reaches the point of refusal, brace the base of the port and pull out gently on the head of the port to close it. Pulling too hard may dislodge the port from the surface of the concrete, causing a leak. Depress the metal tab on the head of the E-Z-Click fitting and remove it from the port. 5. Go to the last port where epoxy appeared while injecting the first port, open it, and continue injection at this port. If the epoxy has set up and the port is bonded closed, move to the next clean port and repeat the process until every portion of the crack has refused epoxy. While this method may appear to leave some ports uninjected, it provides maximum pressure to force the epoxy into the smaller areas of the crack. Moving to the next port as soon as epoxy appears will allow the epoxy to travel along the wider parts of the crack to the next ports rather than force it into the crack before it travels to the next ports. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 161 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Injection Tips · If using a pneumatic dispensing tool, set the tool at a low setting when beginning injection and increase pressure if necessary to get the epoxy to flow. · For narrow cracks it may be necessary to increase the pressure gradually until the epoxy begins to flow. It may also be necessary to wait a few minutes for the epoxy to fill the crack and travel to the next port. · If desired, once the injection epoxy has cured, remove the injection ports and paste-over. Epoxy paste-over can be removed with a chisel, scraper, or grinder. The paste-over can be simply peeled off if CIP-F is used. Using a heat gun to soften the epoxy is recommended when using a chisel or scraper. · Mixing nozzles can be used for multiple cartridges as long as the epoxy does not harden in the nozzle. For injection epoxies in side-by-side cartridges, care must be taken to ensure the level of material is the same on both parts of the cartridge. This can be done by checking for air in the cartridge and the positions of the wipers in the back of the cartridge. If the liquid levels are off by more than 1/8", then Step 1 from the injection procedures must be repeated. Restoration Solutions Troubleshooting Epoxy is flowing into the crack, but not showing up at the next port. This most likely indicates that epoxy is running out of the unsealed backside of the crack. In this case the application may require a gel viscosity injection epoxy (CI-GV) or may not be suitable for epoxy injection repair without excavation and sealing of the backside of the crack. This may also indicate that either the crack expands and/or branches off under the surface of the concrete. Continue to inject and fill these voids. In situations where the crack penetrates completely through the concrete element and the backside of the concrete element cannot be sealed (e.g., basement walls, or footings with backfill) longer injection time may not force the epoxy to the next port. Epoxy is leaking from the pasted-over crack or around injection ports. Stop injecting. If using a fast cure paste-over material (CIP-F, CIP-LO or ETR), wipe off the leaking injection epoxy with a cotton cloth and reapply the paste over material. Wait approximately 10 to 15 minutes to allow the paste-over to begin to harden. If the leak is large (e.g., the port broke off of the concrete surface) it is a good idea to wait approximately 30 minutes, or longer as necessary, to allow the paste over to cure more completely. Check to see that the paste-over is hard before reinjecting or the paste-over or ports may leak. Another option for small leaks is to clean off the injection epoxy and use paraffin or crayon to seal the holes. More epoxy is being used than estimated. This may indicate that the crack either expands or branches off below the surface. Continue to inject and fill these voids. This may also indicate that epoxy is running out of the backside of the crack. If the crack penetrates completely through the concrete element and cannot be sealed, the application may not be suitable for injection repair. 162 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Troubleshooting (cont.) Back pressure is preventing epoxy from flowing. This can indicate several situations: · The crack is not continuous and the portion being injected is full (see above instructions about injection after the port has reached refusal). See Step 4 on p. 161. · The port is not aligned over the crack properly. · The crack is blocked by debris. · The injection epoxy used has too high a viscosity. · If the mixing nozzle has been allowed to sit for a few minutes full of epoxy, the material may have hardened in the nozzle. Attach the E-Z-ClickTM fitting to a port at another uninjected location on the crack and attempt to inject. If the epoxy still won't flow, chances are the epoxy has hardened in the nozzle. Less epoxy is being used than estimated. This may indicate that the crack is shallower than originally thought, or the epoxy is not penetrating the crack sufficiently before moving to the next port. Reinject some ports with a lower viscosity epoxy to see if the crack will take more epoxy. Another option is to heat the epoxy to a temperature of 80100°F which will reduce its viscosity and allow it to penetrate into small cracks easier. The epoxy should be heated uniformly, do not overheat cartridge. Restoration Solutions Injection Procedure for Crack-Pac® Flex-H2OTM Crack Sealer 1. Follow cartridge preparation instructions on the cartridge label. Verify that the material flowing from the nozzle is a uniform green color. 2. Attach the E-Z-Click fitting to the end of the nozzle by pushing the tubing over the barbs at the end of the nozzle. Make sure that all ports are pushed into the open position. If crack is dry, introduce a small amount of water (12 mL) into each open port using a dropper, pipet, syringe or squirt bottle. 3. Attach the E-Z-Click injection fitting to the first E-Z-Click port until it clicks into place. Make sure that the head of the port is pushed into the open position. In vertical applications, begin injection at the lowest port and work your way up. In a horizontal application, start at one end of the crack and work your way to the other end. 4. Inject polyurethane into the first port until material shows at the next port. Remove the E-Z-Click fitting by bracing the base of the port and pulling out gently on the head of the port to close it. Pulling too hard may dislodge the port from the surface of the concrete, causing a leak. Depress the metal tab on the head of the E-Z-Click fitting and remove it from the port. 5. Move to the next port and repeat until all ports have been injected. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 163 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Injection Tips for Crack-Pac® Flex-H2OTM Crack Sealer · For narrow cracks, it may be necessary to increase the pressure gradually until the polyurethane begins to flow. It may also be necessary to wait a few minutes for the material to fill the crack and travel to the next port. · If desired, once the polyurethane has cured, remove the injection ports and paste-over. Epoxy paste-over can be removed with a chisel, scraper, or grinder. The paste-over can be simply peeled off if CIP-F is used. Using a heat gun to soften the epoxy is recommended when using a chisel or scraper. Restoration Solutions Troubleshooting for Crack-Pac Flex-H2O Crack Sealer Polyurethane is flowing into the crack, but not showing up at the next port. This can indicate several situations: · That polyurethane is running out the unsealed backside of the crack. · There is not enough water present to react with the polyurethane and generate foam. · The crack either expands and/or branches off under the surface of the concrete. Continue to inject and fill these voids. In situations where the crack penetrates completely through the concrete element, and the backside of the concrete element cannot be sealed (e.g., basement walls, or footings with backfill), longer injection time may not force the polyurethane to the next port. This most likely indicates that polyurethane is running out the unsealed backside of the crack. In this case, the application may require a gel viscosity injection epoxy (CI-GV) or may not be suitable for injection repair without excavation and sealing of the backside of the crack. Back pressure is preventing polyurethane from flowing. This can indicate several situations: · The crack is not continuous and the portion being injected is full. · The port is not aligned over the crack properly. · The crack is blocked by debris. Attach the E-Z ClickTM fitting to the next uninjected port on the crack and continue the injection. Polyurethane is leaking from the pasted-over crack or around injection ports. Stop injecting. If using a fast cure paste-over material (CIP-F, CIP-LO or ETR), wipe off the leaking polyurethane with a cotton cloth and reapply the paste over material. Wait approximately 1015 minutes to allow the paste-over to begin to harden. If the leak is large (e.g., the port broke off of the concrete surface), it is a good idea to wait approximately 30 minutes, or longer as necessary, to allow the paste-over to cure more completely. Check to see that the paste-over is hard before reinjecting or the paste-over or ports may leak. Another option for small leaks is to clean off the injection adhesive and use paraffin or crayon to seal the holes. 164 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Guide Troubleshooting for Crack-Pac® Flex-H2OTM Crack Sealer (cont.) More polyurethane is being used than estimated. This may indicate there is not enough water present to react with the polyurethane and generate foam. Introduce water into the port and continue to inject. Introduce water into subsequent ports prior to injection. This may also indicate that the crack either expands or branches off below the surface. Continue to inject and fill these voids. Less polyurethane is being used than estimated. This may indicate that the crack is shallower than originally thought, or the polyurethane is not penetrating the crack sufficiently before moving to the next port. Ensure polyurethane foam presents at the next injection port before moving to that port or fill the crack at the port until rejection. Gravity-Feed Procedure Some horizontal applications where complete penetration is not a requirement can be repaired using the gravity-feed method. 1. Follow cartridge preparation instructions on the cartridge label. Verify that the material flowing from the Optimix® mixing nozzle is a uniform and consistent color. 2. Starting at one end of the crack, slowly dispense epoxy into the crack, moving along the crack as it fills. It will probably be necessary to do multiple passes in order to fill the crack. It is possible that the epoxy will take some time to run into the crack, and the crack may appear empty several hours after the initial application. Reapply epoxy until the crack is filled. 3. In situations where the crack completely penetrates the member (e.g., concrete slab), the material may continue to run through the crack into the subgrade. It may be possible to use a small amount of course, dry sand to act as a barrier for the injection epoxy. Place the sand in the crack to a level no more than 1/4 the thickness of the member and apply the injection epoxy as described in step 2. The epoxy level will drop as it penetrates the sand, but should cure and provide a seal to the bottom of the crack. Reapply the epoxy until the crack is filled. In some cases, application of sand is impractical or not permitted and epoxy repair may not provide a complete and effective repair. Use of a gel viscosity injection epoxy (CI-GV) may permit a surface repair to the crack with partial penetration. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 165 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Heli-TieTM Helical Wall Tie The Heli-Tie helical wall tie is a stainless-steel tie used to anchor building façades to structural members or to stabilize brick walls. The helical design allows the tie to be driven quickly and easily into a predrilled pilot hole (or embedded into mortar joints in new construction) to provide a mechanical connection between a masonry façade and its backup material. As it is driven, the fins of the tie undercut the masonry to provide an expansion-free anchorage that will withstand tension and compression loads. The Heli-Tie wall tie is installed into a predrilled hole using a proprietary setting tool with an SDS-plus® shank rotohammer to drive and countersink the tie. Heli-Tie wall ties perform in concrete and masonry as well as wood and steel studs. Heli-Tie Helical Wall Tie US Patent: 7,269,987 Features · Installs quickly and easily -- with the rotohammer in hammer mode, the tie installs faster than competitive products. · Provides an inconspicuous repair that preserves the appearance of the building. After installation, the tie is countersunk up to 1/2" below the surface, allowing the tie location to be patched. · Larger core diameter provides higher torsional capacity, resulting in less deflection due to "uncoiling" under load. · Fractionally sized anchor -- no metric drill bits required. · Patented manufacturing process results in a more uniform helix along the entire tie, allowing easier driving and better interlock with the substrate. Material: Type 304 stainless steel (Type 316 available by special order -- contact Simpson Strong-Tie for details) Test Criteria: CSA A370 Restoration Solutions 166 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Heli-TieTM Helical Wall Tie Installation · Drill pilot hole through the façade material and into the backup material to the specified embedment depth + 1" using appropriate drill bit(s) in the chart below. Drill should be in rotation-only mode when drilling into soft masonry or into hollow backing material. · Position blue end of the Heli-Tie fastener in the installation tool and insert the tie into the pilot hole. · With the SDS-plus® rotohammer in hammer mode, drive the tie until the tip of the installation tool enters the exterior surface of the masonry and countersinks the tie below the surface. Patch the hole in the façade with a matching masonry mortar. Heli-Tie Helical Wall Tie Product Data Size (in.) Model No. Drill Bit Diameter (in.) Quantity Box Carton 3/8 x 7 HELI37700A 50 400 3/8 x 8 HELI37800A 50 400 3/8 x 9 HELI37900A 50 400 3/8 x 10 HELI371000A 50 200 3/8 x 11 HELI371100A 50 200 7/32 or 1/4 3/8 x 12 HELI371200A 50 200 3/8 x 14 HELI371400A 50 200 3/8 x 16 HELI371600A 50 200 3/8 x 18 HELI371800A 50 200 3/8 x 20 HELI372000A 50 200 Special-order lengths are also available; contact Simpson Strong-Tie for details. Restoration Solutions S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 167 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Heli-TieTM Design Information Installation Sequence Restoration Solutions Watch how to install Heli-Tie helical wall ties at strongtie.com/videolibrary. 168 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Heli-TieTM Accessories Heli-Tie Fastener Installation Tool -- Model HELITOOL37A Required for correct installation of Heli-Tie wall ties. Speeds up installation and automatically countersinks the tie into the façade material. HELITOOL37A Heli-Tie Wall Tie Tension Tester -- Model HELITEST37A Recommended equipment for onsite testing to accurately determine load values in any specific structure, the Heli-Tie wall tie tension tester features a key specifically designed to grip the Heli-Tie fastener and provide accurate results. Replacement test keys sold separately (Model HELIKEY37A). Contact Simpson Strong-Tie for Heli-Tie onsite testing procedures. Restoration Solutions HELITEST37A HELIKEY37A For more information see strongtie.com/helitie. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 169 Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Heli-TieTM Helical Stitching Tie The Simpson Strong-Tie® Heli-Tie helical stitching tie provides a unique solution to the preservation and repair of damaged brick and masonry structures. Ties are grouted into existing masonry joints to repair cracks and increase strength with minimum disturbance. Made of Type 304 stainless steel, the Heli-Tie stitching tie features radial fins formed on the steel wire via cold rolling process, increasing the tensile strength of the tie. HELIST254000 Features · Helical design distributes loads uniformly over a large surface area · Installs into the mortar joint to provide an inconspicuous repair and preserve the appearance of the structure · Type 304 stainless steel offers superior corrosion resistance to mild steel reinforcement · Patented manufacturing process results in consistent, uniform helix configuration (US Patent: 7,269,987) · Batch number printed on each tie for easy identification and inspection HELIST254000: 1/4" x 40" stitching tie (special lengths are available upon request) Material: Type 304 stainless steel Ordering Information: Sold in tubes of 10 Installation Instructions · Chase bed joint 20" on either side of the affected area to a depth of approximately 1 1/4" with a rotary grinding wheel. Vertical spacing of installation sites should be 12" for red brick or "every other course" for concrete masonry units. · Clear bed joint of all loose debris. · Mix non-shrink repair grout or mortar per product instructions and place into the prepared bed joint, filling the void to approximately two-thirds of its depth. Simpson Strong-Tie RPS-263 Rapid-Hardening Vertical / Overhead Repair Mortar should be used. · Embed the tie at one-half the depth of the void. Trowel displaced grout to fully encapsulate the tie. · Fill any remaining voids and vertical cracks with non-shrink repair grout or other repair mortar to conceal repair site. 170 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Heli-TieTM Helical Stitching Tie Installation Sequence Restoration Solutions 20 in. 20 in. 20 in. 20 in. Watch how to install Heli-Tie helical wall ties at strongtie.com/videolibrary. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 171 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CSS V-WrapTM Composite Strengthening SystemsTM Smarter Strengthening Solutions Restoration Solutions A Strong Alliance for Stronger Structures Through their alliance, Simpson Strong-Tie and Structural Technologies offer one-stop, end-to-end concrete and masonry strengthening and repair solutions with the best products, installation and support available. Integrated Design-Build Solutions Simpson Strong-Tie, a leading provider of tested, code-listed, high-performance products and technical services for the construction industry, and Structural Technologies, a renowned provider of state-of-the-art infrastructure strengthening solutions and engineering support services, have formed a strategic alliance within North America. This new alliance enables both companies to jointly deliver complete end-to-end repair and strengthening solutions to engineering professionals, general contractors and owners across multiple construction and repair markets. The combination of innovative products, design support, engineering partners and contracting services allows us to deliver fully integrated design-build solutions from initial problem investigation through final installation. 172 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CSS V-WrapTM Composite Strengthening SystemsTM Simpson Strong-Tie offers decades of innovative engineersupported products, cutting-edge testing capabilities, relentless customer service and dedicated field-engineering support. Smarter Smart StrengtheSntirnegng SolutionsSoluti Structural Technologies brings their deep industry knowledge, solutions, design support and technical services, along with licensed installers, to the alliance. Together, we offer a uniquely integrated scope of technical knowledge and solutions for concrete and masonry strengthening and repair that ultimately better serves your needs and helps ensure stronger, safer, longer-lasting structures. Restoration Solutions One End-to-End Solution. Twice the Expertise. · Design, engineering and specification services · Innovative product solutions · Advanced testing capabilities · Expert installation and maintenance service by licensed installers · Dedicated customer service and onsite field engineers Let us help you find the right solution for your project and budget. For additional information, visit strongtie.com/alliance or call (800) 999-5099 to discuss your project with a local field engineer. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 173 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CSS V-WrapTM Composite Strengthening SystemsTM CSS Solutions CSS enhances the strength of existing structural elements which require additional strengthening, rehabilitation and repair in such applications as seismic retrofit, structural preservation, force protection, blast mitigation, and corrosion-related repair and rehabilitation. CSS increases strength without adding weight or mass like traditional strengthening methods. CSS Reinforcement Solutions for Structural Elements Reinforcement Type Slab Structural Element Beam Wall Column/Pile Externally Applied Laminates Flexural/Collector Flexural/Collector Tensile/Flexural Flexural Near-Surface Mounted Laminates Flexural/Collector Flexural/Collector Tensile/Flexural Flexural Fabrics Flexural/Collector Shear/Flexural/ Collector Shear/Flexural/ Tensile Shear/Flexural/ Confinement FRCM Flexural/Collector Shear/Flexural/ Collector Shear/Flexural/ Tensile Shear/Flexural/ Confinement Restoration Solutions 174 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Restoration Solutions Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry CSS V-WrapTM Composite Strengthening SystemsTM 2 4 3 1 6 5 1. Slab -- Adds collector reinforcement, negative (not shown) and positive moment flexural capacity 2. Slab opening -- Trim reinforcement 3. Beam -- Laminates, FRCM or fabrics for flexure and/or collector reinforcement, fabrics or FRCM for shear stirrup reinforcement and potential use of FRP anchors (shown in orange) 4. Wall -- Stiffening, flexural, shear or tensile reinforcement with FRCM, fabrics and/or laminates (FRCM shown above) 5. New wall opening -- Trim reinforcement 6. Column wrapping -- Full column wrap to achieve required strengthening, possibly with additional near-surface mounted laminates, FRCM or fabric for flexure; effective solution for under-reinforced column ties 7. Protective coating -- High-performance protection against exposure, corrosion, chemical attack, abrasion, fire resistance and other environmental factors S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 175 Carbide Drill Bits Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry SDS-plus® Drill Bits SDS-plus Shank Bits -- Retail Packs Diameter (in.) Drilling Depth (in.) Overall Length (in.) Quantity (per pack) 5/32 4 6 1/4 25 2 4 1/4 25 4 6 1/4 25 6 8 1/4 25 3/16 8 10 25 10 12 25 12 14 25 4 6 1/4 25 7/32 6 8 1/4 25 8 10 25 2 4 1/4 25 4 6 1/4 25 1/4 6 8 1/4 25 8 10 25 5/16 4 6 1/4 25 4 6 1/4 25 3/8 10 12 1/4 25 4 6 1/4 25 1/2 10 12 1/4 25 5/8 6 8 20 Model No. MDPL01506-R25 MDPL01804-R25 MDPL01806-R25 MDPL01808-R25 MDPL01810-R25 MDPL01812-R25 MDPL01814-R25 MDPL02106-R25 MDPL02108-R25 MDPL02110-R25 MDPL02504-R25 MDPL02506-R25 MDPL02508-R25 MDPL02510-R25 MDPL03106-R25 MDPL03706-R25 MDPL03712-R25 MDPL05006-R25 MDPL05012-R25 MDPL06208-R20 Carbide Drill Bits SDS-plus Retail Packs 178 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry SDS-plus® Drill Bits SDS-plus Shank Bit SDS-plus bits use an asymmetrical-parabolic flute for efficient energy transmission and dust removal. SDS-plus Shank Bits Diameter (in.) Drilling Depth (in.) 2 5/32 4 4 6 3/16 8 10 Overall Length (in.) 4 1/4 6 1/4 6 1/4 8 1/4 10 12 Model No. MDPL01504 MDPL01506 MDPL01806 MDPL01808 MDPL01810 MDPL01812 12 14 MDPL01814 4 6 1/4 6 8 1/4 7/32 8 10 MDPL02106 MDPL02108 MDPL02110 14 16 MDPL02116 2 4 1/4 MDPL02504 4 6 1/4 6 8 1/4 1/4 8 10 MDPL02506 MDPL02508 MDPL02510 12 14 MDPL02514 14 16 MDPL02516 4 6 1/4 5/16 10 12 MDPL03106 MDPL03112 4 6 1/4 MDPL03706 8 10 1/4 3/8 10 12 1/4 16 18 MDPL03710 MDPL03712 MDPL03718 22 24 4 6 1/4 7/16 10 12 1/4 MDPL03724 MDPL04306 MDPL04312 Table continues on the next page. SDS-plus Shank Bit Carbide Drill Bits S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 179 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry SDS-plus® Drill Bits SDS-plus Shank Bit (cont.) SDS-plus Shank Bits Diameter (in.) Drilling Depth (in.) 4 8 1/2 10 16 22 4 9/16 10 16 6 10 5/8 16 22 11/16 6 6 8 3/4 10 16 22 6 7/8 10 16 8 1 16 Overall Length (in.) 6 1/4 10 1/4 12 1/4 18 24 6 1/4 12 1/4 18 8 12 18 24 8 8 10 12 18 24 8 12 1/4 18 10 18 Model No. MDPL05006 MDPL05010 MDPL05012 MDPL05018 MDPL05024 MDPL05606 MDPL05612 MDPL05618 MDPL06208 MDPL06212 MDPL06218 MDPL06224 MDPL06808 MDPL07508 MDPL07510 MDPL07512 MDPL07518 MDPL07524 MDPL08708 MDPL08712 MDPL08718 MDPL10010 MDPL10018 SDS-plus Shank Bit Carbide Drill Bits 180 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry SDS-max® Drill Bits Carbide Drill Bits SDS-max and SDS-max Quad Head Shank Bits Diameter (in.) Drilling Depth (in.) Overall Length (in.) Model No. 3/8 7 1/2 13 MDMX03713 7 1/2 13 1/2 15 1/2 21 MDMX05013 MDMX05021 7 1/2 13 9/16 15 1/2 21 MDMX05613 MDMX05621 7 1/2 13 MDMX06213Q 5/8 15 1/2 21 MDMX06221Q 30 1/2 36 MDMX06236Q 11/16 15 1/2 21 MDMX06821Q 8 13 MDMX07513Q 3/4 17 21 MDMX07521Q 31 36 MDMX07536Q 13/16 17 21 MDMX08121Q 8 13 MDMX08713Q 7/8 17 21 MDMX08721Q 8 13 MDMX10013Q 1 17 21 MDMX10021Q 31 36 MDMX10036Q 1 1/16 18 23 MDMX10623Q 12 17 MDMX11217Q 1 1/8 17 21 MDMX11221Q 31 36 MDMX11236Q 1 3/16 18 23 MDMX11823Q 10 15 MDMX12515Q 1 1/4 18 23 MDMX12523Q 31 36 MDMX12536Q 12 1 3/8 18 17 MDMX13717Q 23 MDMX13723Q 1 1/2 18 23 MDMX15023Q 1 3/4 18 23 MDMX17523Q 2 18 23 MDMX20023Q Model numbers ending with "Q" denote Quad Head. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. SDS-max Shank Bit Quad Head 181 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Straight Shank Drill Bits Straight Shank Bits Diameter Drilling Depth Overall Length (in.) (in.) (in.) 1/8 1 3/8 3 3/16 4 6 2 1/8 4 1/4 4 6 10 12 5/16 4 6 4 6 3/8 10 12 7/16 4 6 4 6 1/2 10 12 5/8 3 1/2 6 3/4 4 6 Model No. MDB01203 MDB01806 MDB02504 MDB02506 MDB02512 MDB03106 MDB03706 MDB03712 MDB04306 MDB05006 MDB05012 MDB06206 MDB07506 Straight Shank Bits Retail Packs Diameter (in.) Drilling Depth (in.) Overall Length (in.) Quantity (per pack) 3/16 4 6 25 2 1/8 4 25 1/4 4 6 25 5/16 4 6 25 3/8 4 6 25 1/2 4 6 25 Model No. MDB01806-R25 MDB02504-R25 MDB02506-R25 MDB03106-R25 MDB03706-R25 MDB05006-R25 Straight Shank Bit Carbide Drill Bits Straight Shank Bits Retail Packs 182 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Core Bits Simpson Strong-Tie core bits are made to the same exacting standards as our standard carbide-tipped drill bits. They utilize a centering bit to facilitate accurate drilling in combination hammer/drill mode. Core Bits with Centering Bit -- SDS-max® Shank Diameter (in.) Drilling Depth (in.) Overall Length (in.) Model No. 2 6 1/4 22 CBMX20022 2 5/8 6 1/4 22 CBMX26222 3 1/8 6 1/4 22 CBMX31222 3 1/2 6 1/4 22 CBMX35022 4 6 1/4 22 CBMX40022 5 6 1/4 22 CBMX50022 Note: With one-piece bits, once coring is begun, the centering bit must be removed using ejector pin. Core bit bodies are 2 11/16" deep. Carbide Drill Bits Core Bit Transfers Energy Efficiently Core Bit Center Pilot Bit (CTRBTF04304) Ejector Key (CDBEJKEY) S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 183 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Demolition Bits Flat Chisels General Concrete and Masonry Demolition Shank Type Head Width Overall Length (in.) (in.) Model No. 1 SDS-max® 1 12 CHMXF10012 18 CHMXF10018 Flat Chisel Bull-Point Chisels General Concrete and Masonry Demolition Shank Type Overall Length (in.) Model No. SDS-plus® 10 CHPLBP10 SDS-max 12 CHMXBP12 18 CHMXBP18 Bull-Point Chisel Asphalt Cutters Asphalt, Hardpan and Compacted Soil Cutting Shank Type Head Width Overall Length (in.) (in.) Model No. SDS-max 3 1/2 16 CHMXAC35016 3/4" Hex 3 1/2 16 CHHAC35016 Asphalt Cutter Carbide Drill Bits Ground Rod Drivers Driving in Ground Rods Shank Type Head Width Overall Length (in.) (in.) Model No. SDS-max 7/8 10 1/4 CHMXRD08710 Ground Rod Driver 184 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Demolition Bits Scrapers Removing Tiles, Flooring and Other Materials Shank Type Head Width Overall Length (in.) (in.) Model No. 3/4 SDS-plus® 1 1/2 10 CHPLF07510 10 CHPLSC15010 SDS-max® 2 12 CHMXSCP20012 Scraper Bushing Tools One Piece Concrete and Asphalt Surface Roughening Shank Type Head Width Overall Length (in.) (in.) Model No. SDS-max 1 3/4 9 1/2 CHMXBT17509 Scalers Removing Large Quantities of Material Shank Type Head Width Overall Length (in.) (in.) Model No. 1 1/2 12 CHMXSC15012 SDS-max 2 12 CHMXSC20012 3 12 CHMXSC30012 Bushing Tool Head Scaler Carbide Drill Bits S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 185 Appendix Appendix Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Appendix Anchor Products for Corrosive Environments pp. 188193 Light-Frame Construction pp. 194195 Retrofit and Repair pp. 196197 Crack Injection pp. 198199 Wastewater / Water Treatment pp. 200201 Bridge and Marine pp. 202203 Manufacturing, Maintenance and Material Handling (OEM) Composite Strengthening SystemsTM pp. 204205 pp. 206207 Cold-Formed Steel Construction pp. 208209 Appendix S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 187 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Anchor Products for Corrosive Environments Appendix Trusted quality, code approved and innovative stainless-steel anchors that can be installed in exterior and corrosive environments. When it comes to anchorage, specifying a material that can withstand the environment is critical. Proper protection comes from materials that are capable of resisting corrosion while maintaining their strength. Most anchor products are made from carbon steel. This material is easy to form into a screw or an expansion anchor and can be heat treated to increase its strength and durability. Steel is versatile but can weaken in a corrosive environment. Left unprotected, the iron in the steel will react with oxygen and moisture to form iron oxide -- also known as rust. Environments There are four levels of corrosive environments (as shown below). Minimum Corrosion Resistance Recommendations Corrosion Resistance Classification by Environment Recommended Product Material or Coating Low Zinc plated Medium Mechanically galvanized (ASTM B695 -- Class 55) Hot-dip galvanized (ASTM A153 -- Class C) High Type 303 or 304 stainless steel Severe Type 316 stainless steel 188 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Anchor Products for Corrosive Environments Quick Guide to Choosing the Right Stainless-Steel Grade High to Severe A highly corrosive environment is a location where anchors are exposed to chemicals such as fertilizers, soil, acid rain and other corrosive elements. Examples of these environments include kitchens, industrial zones, food-processing facilities, wineries, breweries, outdoor facilities and severe exterior conditions. Typical high-corrosive environment -- central utility plants. Typical high-corrosive environment -- foodprocessing plants. Typical severe-corrosive environment -- wastewater treatment plants. Medium A medium-level corrosive environment is typically a general exterior location where chlorides or corrosive chemical elements are not present. Anchors installed in interior conditions where the anchor is attaching a treated lumber may also require a mediumlevel corrosive-resistive anchor. Examples of elements at risk to medium-exposure corrosion are stadium seating, exterior handrails, exterior facade anchorages and other components of outdoor facilities. Appendix Typical medium exposure -- outdoor seating. Typical medium-corrosive environment -- exterior anchorage. Low Finally, low-corrosive environments consist of interior dry spaces. Examples of such applications are warehouse racking, machinery installations, facility catwalk anchorage, interior furniture anchorages and so forth. Typical low-corrosive environment -- interior warehouse. S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 189 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Anchor Products for Corrosive Environments Types 304, 316 and 410 stainless-steel products for your job. Anchor -- Stainless-Steel Products Drop-In (DIA) internally threaded anchor Sleeve-All® sleeve anchor Stainless-steel Titen HD® heavy-duty screw anchor Strong-Bolt® 2 wedge anchor Titen® stainless-steel concrete and masonry screw Type 304 Type 316 Type 410 Stainless-Steel Titen HD Heavy-Duty Screw Anchor Stainless-Steel Titen HD Countersunk Heavy-Duty Screw Anchor Strong-Bolt 2 Wedge Anchor Stainless-Steel Titen Concrete and Masonry Screw Appendix Sleeve-All Sleeve Anchor Drop-In (DIA) Internally Threaded Anchor 190 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Anchor Products for Corrosive Environments Concrete Adhesives for Stainless-Steel Threaded Rod Appendix SET-3GTM High-Strength Epoxy Adhesive · Excellent bond strengths in all applications including submerged, waterfilled, damp and dry holes at temperatures between 40°F and 100°F. · NSF/ANSI standard 61 approved SET-XP® High-Strength Epoxy Adhesive · Install in dry and water saturated holes in base materials with temperatures between 50°F and 110°F · NSF/ANSI/CAN 61 approved AT-XP® High-Strength, Fast-Cure, All-Weather Acrylic Adhesive · Can be used in cold temperatures as low as 14°F · NSF/ANSI standard 61 approved Adhesive Anchor -- Stainless-Steel Rods ASTM A193, Grade B8 and B8M (Types 304 and 316) ASTM A593 CW (Types 304 and 316) SET-3G SET-XP AT-XP ASTM A193, Grade B6 (Type 410) S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 191 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Anchor Products for Corrosive Environments When designing strong and durable anchorage solutions for high and severe corrosive environments, the two most commonly considered materials are Types 304 and 316 stainless steel. Type 300 Series stainless-steel screw anchors have different corrosion-resistant properties for different environments. When matched to the appropriate environment and application, anchors made from Type 300 Series stainless steel will resist the effects of corrosion and maintain their strength and integrity. Type 316 is the optimal choice for applications in severe corrosive or extreme environments such as salt water, or when chemical or corrosive solutions are present. Type 304 is a cost-effective solution for high corrosive applications where the environment may be wet, moist or damp. Type 316 Stainless Steel · Wastewater treatment · Fertilizer storage buildings · Sill plates in coastal environments · Marine/port restoration · Light rail (transportation) · Agricultural facilities · Pulp and paper mills · Parking structures · Tunnels · Balconies in coastal environments · Outdoor railings in coastal environments Appendix 192 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Anchor Products for Corrosive Environments Type 304 Stainless Steel · Stadium seating · Curtain walls · Clean rooms · Central utility plant facilities · Food-processing facilities · Ledger bolts for decks · DOT signs and fixtures · Cooling towers · Scaffolding · Parking structures · Balconies · Refineries · Breweries and wineries · Fencing · Outdoor railings Appendix S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 193 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Light-Frame Construction Anchoring Adhesives SET-3GTM AT-XP® SET-XP® Mechanical Anchors ET-HP® Appendix Titen HD® Titen HD SS Titen HD Strong-Bolt® 2 Titen TurboTM Washer Head Direct Fastening Systems Powder-Actuated Systems PDPAWL PDPA 194 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Light-Frame Construction Carbide Drill Bits Framing Hardware (New and Retrofit) Post Bases for Decks, Railings and Patio Covers Titen HD®, Strong-Bolt® 2, Titen HD rod coupler, anchoring adhesives Ledgers Appendix Titen HD SS (exterior), Titen HD (interior), Strong-Bolt 2, anchoring adhesives Titen HD SS, Strong-Bolt 2, anchoring adhesives S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 195 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Retrofit and Repair Anchoring Adhesives Mechanical Anchors SET-3GTM AT-XP® SET-XP® ET-HP® Titen HD® Titen HD Titen HD Titen HD Titen SS CS CS SS TurboTM Opti-Mesh Screen Tube Steel Screen Tube Piston Plug CI Structural Injection Epoxy Strong-Bolt® 2 Strong-Bolt 2 Sleeve-All Sleeve-All SS SS Appendix Drop-In Drop-In SS Hollow Drop-In Heli-TieTM Available in five formulations (CI-SLV, CI-LV, CI-LV FS, CI-LPL and CI-GV) for cracks ranging from 0.002" to 1/4" (0.05 mm to 6.4 mm). 196 RPS-263 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Retrofit and Repair Composite Strengthening SystemsTM (CSS V-WrapTM) FRP, FRCM, Laminate, FRP Anchors, Epoxy Saturant, Paste, Coatings Smarter Strengthening Solutions Rebar and Smooth Dowelling Seismic Retrofit / Structural Renovation Anchoring adhesives Architectural Attachments Titen HD®, Strong-Bolt® 2, anchoring adhesives Concrete Formwork Titen HD, Strong-Bolt 2, Titen TurboTM, anchoring adhesives Titen HD, DSD, StrongBolt 2 Concrete / Unreinforced Masonry (URM) Retrofit Appendix CSS laminates and CSS-EP Carbon and E-glass FRP Fabrics Fabric-Reinforced Cementitious Matrix (FRCM) S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 197 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection CI Structural Injection Epoxy Crack Injection Appendix CI-SLV CI-LV CI-LV FS CI-LPL Paste-Over and Crack Sealants CI-GV Crack-Pac® Crack-Pac Flex-H2OTM Accessories Optimix® Mixing Nozzle CIP-LO CIP-F E-Z-ClickTM Ports and Injection Fitting ETR-16 EIPX-EZ Corner-Mount/ EIP-EZA Drilled-In Port Flush-Mount Port 198 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Crack Injection Crack Injection in Concrete Slabs, Walls, Columns and Beams to Restore Structural Integrity Gravity Feed for Cracks in Floors CI-LV, CI-LV FS, CI-GV, CI-SLV, CI-LPL Crack Injection in Swimming Pools CI-LV, CI-LV FS, CI-SLV, CI-LPL, Crack-Pac®, Crack-Pac Flex-H2OTM Dowels to Reinforce Replaced Concrete CI-LV, CI-LV FS, CI-GV, CI-SLV, CI-LPL, Crack-Pac, Crack-Pac Flex-H2O Anchoring adhesives Appendix S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 199 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Wastewater / Water Treatment For more information, please visit strongtie.com/solutions/wastewater. Products and Solutions for Water/Wastewater Facilities Anchoring Adhesives Mechanical Anchors High-Strength Adhesives Composite Strengthening SystemsTM and Crack Repair S-A-WWT18.indd 1 Flier S-A-WWT 10/3/18 11:27 AM SET-3GTM AT-XP® Mechanical Anchors SET-XP® ET-HP® Appendix Titen HD® SS Titen HD CS SS Strong-Bolt® 2 SS Sleeve-All SS Drop-In SS CI Structural Injection Epoxy Crack Injection Available in five formulations (CI-SLV, CI-LV, CI-LV FS, CI-LPL and CI-GV) for cracks ranging from 0.002" to 1/4" (0.05 mm to 6.4 mm). 200 Crack-Pac® Flex-H2OTM S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Wastewater / Water Treatment Composite Strengthening SystemsTM (CSS V-WrapTM) FRP, FRCM, Laminate, FRP Anchors, Epoxy Saturant, Paste, Coatings Smarter Strengthening Solutions Crack Injection -- Paste-Over and Crack Sealants CIP-LO CIP-F Carbide Drill Bits ETR-16 Pumps and Equipment Concrete / URM Retrofit Appendix Titen HD® SS, Strong-Bolt® 2 SS, anchoring adhesives Gates CSS laminates and CSS-EP Pipe Supports Titen HD® SS, Strong-Bolt® 2 SS, anchoring adhesives Titen HD, Titen HD threaded rod hanger, Strong-Bolt 2, Wedge-All, Drop-In S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 201 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Bridge and Marine Anchoring Adhesives CI Structural Injection Epoxy SET-3GTM AT-XP® SET-XP® ET-HP® Available in five formulations (CI-SLV, CI-LV, CI-LV FS,CI-LPL and CI-GV) for cracks ranging from 0.002" to 1/4" (0.05 mm to 6.4 mm). Mechanical Anchors Appendix Titen HD® SS Titen HD CS SS Strong-Bolt® 2 SS Sleeve-All SS Drop-In SS Composite Strengthening SystemsTM (CSS V-WrapTM) FRP, FRCM, Laminate, FRP Anchors, Epoxy Saturant, Paste, Coatings Smarter Strengthening Solutions 202 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Bridge and Marine Concrete Formwork Barriers and Guardrails Titen HD® SS, StrongBolt® 2 SS Heavy- and Light-Duty Signs Titen HD SS, Strong-Bolt 2 SS, anchoring adhesives Attaching Precast Elements Titen HD SS, Strong-Bolt 2 SS, anchoring adhesives Dowels for Jersey Barriers Titen HD SS, Strong-Bolt 2 SS, anchoring adhesives Glare Screens Appendix Anchoring adhesives Composite Strengthening SystemsTM (CSS V-WrapTM) Titen HD SS, Strong-Bolt 2 SS, anchoring adhesives Underwater and marine coatings S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 203 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Manufacturing, Maintenance and Material Handling (OEM) Anchoring Adhesives SET-3GTM AT-XP® SET-XP® ET-HP® Mechanical Anchors Appendix Titen HD® Titen HD SS Titen HD CS Strong-Bolt® 2 Strong-Bolt 2 SS Titen TurboTM 204 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Manufacturing, Maintenance and Material Handling (OEM) Racking Dock Doors and Bumpers Titen® HD, Strong-Bolt® 2 Conveyors and Rollers Titen HD SS, Strong-Bolt 2 SS, anchoring adhesives Steel Beams / Columns Titen HD, Strong-Bolt 2, anchoring adhesives Stadium Seating Titen HD, Strong-Bolt 2, anchoring adhesives Awnings Titen HD, Strong-Bolt 2, anchoring adhesives Titen HD, Strong-Bolt 2, anchoring adhesives Appendix S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 205 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Composite Strengthening SystemsTM (CSS V-WrapTM) Smarter Strengthening Solutions A Strong Alliance for Stronger Structures Through their alliance, Simpson Strong-Tie and Structural Technologies offer one-stop, end-to-end concrete and masonry strengthening and repair solutions with the best products, installation and support available. CI Structural Injection Epoxy Crack Injection Appendix CI-SLV CI-LV CI-LV FS CI-LPL CI-GV Paste-Over and Crack Sealants Crack-Pac® Crack-Pac Flex-H2OTM 206 CIP-LO CIP-F ETR-16 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Composite Strengthening SystemsTM (CSS V-WrapTM) Applications: Seismic Retrofit · Shear strengthening · Displacement/ductility · Life safety Load Rating Upgrade · Increased loads · New equipment · Change of use Damage Repair · Deterioration/corrosion · Blast/vehicle impact Defect Remediation · Size/layout errors · Low concrete strengths Blast Mitigation · Hardening · Progressive collapse Buildings Underwater Bridges Piers and Wharfs Tanks / Silos Tunnels Parking Structures Pipes Appendix S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 207 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Cold-Formed Steel Construction Mechanical Anchors Titen HD® Strong-Bolt® 2 Crimp Drive® Titen TurboTM CSD Zinc NailonTM Split-Drive Direct Fastening Systems Appendix Powder-Actuated Systems Gas-Actuated System PDPAWL PDPA PDPAT GDP GDPS 208 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Cold-Formed Steel Construction CFS Curtain Walls Concrete Floor Slab Bypass Steel Connections Titen TurboTM screw Bypass Connections (Concrete or Steel) Direct fastening systems Bottom Track Titen HD®, Strong-Bolt® 2 to concrete and direct fastening systems to steel Ceiling Track Appendix Split-Drive, Crimp Drive®, Zinc NailonTM, direct fastening systems Low-Post or Kneewall Framing Split-Drive, Crimp Drive®, Zinc NailonTM, direct fastening systems Bypass Floor Slab or Steel Attachment RCKW kneewall connection with Titen HD, Strong-Bolt 2 or anchoring adhesives Titen HD to concrete and direct fastening systems to steel S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 209 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Length Identification Head Marks General Installation Guide / Instructions The following tables define the length of various Simpson Strong-Tie® mechanical anchors based upon the letter stamped on the anchor head. The lengths represented are in inches. This information pertains to the following Simpson Strong-Tie mechanical anchors: · Strong-Bolt® 2 · Sleeve-All® Length Identification Head Marks Mark Units A B C D E F G H I From in. 11/2 2 21/2 3 31/2 4 41/2 5 51/2 Up To But Not Including in. 2 21/2 3 31/2 4 41/2 5 51/2 6 Length Identification Head Marks Mark Units J K L M N O P Q R From in. 6 61/2 7 71/2 8 81/2 9 91/2 10 Up To But Not Including in. 61/2 7 71/2 8 81/2 9 91/2 10 11 Length Identification Head Marks Mark Units S T U V W X Y Z From in. 11 12 13 14 15 16 17 18 Up To But Not Including in. 12 13 14 15 16 17 18 19 Appendix 210 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Acceptable Hole Diameter Mechanical Anchors Pre-Load Relaxation Expansion anchors that have been set to the required installation torque in concrete will experience a reduction in pre-tension (due to torque) within several hours. This is known as pre-load relaxation. The high compression stresses placed on the concrete cause it to deform, which results in a relaxation of the pre-tension force in the anchor. Tension in this context refers to the internal stresses induced in the anchor as a result of applied torque and does not refer to anchor capacity. Historical data shows it is normal for the initial tension values to decrease by as much as 4060% within the first few hours after installation. Retorquing the anchor to the initial installation torque is not recommended or necessary. Adhesive Anchors Installation into Green Concrete The strength design data for adhesive anchors in this catalog are based on installations into concrete that is at least 21 days old. For anchors installed into concrete that has cured for less than 21 days, refer to the following modification factors that should be applied to the published adhesive bond strength. Products SET-3G SET-XP AT-XP ET-HP Concrete Age When Installed 14 days 7 days Concrete Age When Loaded 21 days 14 days 21 days 7 days Bond Strength Factor 1.0 0.9 1.0 0.7 Oversized Holes The performance data for adhesive anchors are based upon anchor tests in which holes were drilled with carbide-tipped drill bits of the same diameter listed in the product's load table. Additional static tension tests were conducted to qualify anchors installed with SET-3GTM, SET-XP® and ET-HP® adhesives for installation in holes with diameters larger than those listed in the load tables. The tables indicate the acceptable range of drilled hole sizes and the corresponding tension-load reduction factor (if any). The same conclusions also apply to the published shear load values. Drilled holes outside of the accepted range shown in the charts are not recommended. SET-3G Adhesive -- Acceptable Hole Diameter Insert Diameter (in.) Acceptable Hole Diameter Range (in.) 1/2 9/16 3/4 5/8 11/16 7/8 3/4 7/8 1 7/8 1 1 1/8 1 1 1/8 1 1/4 1 1/4 1 3/8 1 1/2 Acceptable Load Reduction Factor 1.0 1.0 1.0 1.0 1.0 1.0 Appendix S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 211 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Acceptable Hole Diameter Adhesive Anchors (cont.) Oversized Holes (cont.) SET-XP® and ET-HP® Adhesives -- Acceptable Hole Diameter Insert Diameter (in.) Acceptable Hole Diameter Range (in.) Acceptable Load Reduction Factor 1/2 5/8 3/4 1.0 5/8 3/4 15/16 1.0 3/4 7/8 1 1/8 1.0 7/8 1 1 5/16 1.0 1 1 1/8 1 1/2 1.0 1 1/4 1 3/8 1 7/8 1.0 AT-XP® Adhesive -- Acceptable Hole Diameter Insert Diameter (in.) Acceptable Hole Diameter Range (in.) 3/8 7/16 1/2 1/2 9/16 5/8 5/8 11/16 3/4 Acceptable Load Reduction Factor 1.0 1.0 1.0 Core-Drilled Holes The performance data for adhesive anchors are based upon anchor tests in which holes were drilled with carbide-tipped drill bits. Additional static tension tests were conducted to qualify anchors installed with SET-3GTM, SET-XP and ET-HP anchoring adhesives for installation in holes drilled with diamond-core bits. In these tests, the diameter of the diamond-core bit matched the diameter of the carbide-tipped drill bit recommended in the product's load table. SET-3G, SET-XP, and ET-HP anchoring adhesive require a reduction factor of 0.7 applied to the characteristic bond strength (k). The same conclusions also apply to the published allowable shear loads. Tests conducted in core-drilled holes are for non-IBC jurisdictions. Appendix 212 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Acceptable Hole Diameter Adhesive Anchors (cont.) Installation in Water-Saturated Concrete, Water-Filled Holes and Submerged Environments SET-3GTM, SET-XP®, ET-HP® and AT-XP®: The performance data for adhesive anchors using SET-3G, SET-XP, ET-HP and AT-XP adhesives are based upon tests according to ICC-ES AC308. This criteria requires adhesive anchors that are to be installed in outdoor environments to be tested in water-saturated concrete holes that have been cleaned with less than the amount of hole cleaning recommended by the manufacturer. A product's sensitivity to this installation condition is considered in determining the product's "Anchor Category" (strength reduction factor). SET-XP, ET-HP and AT-XP may be installed in dry or water-saturated concrete. SET-3G may be installed in dry or water-saturated concrete, in water-filled holes and in submerged concrete. Reliability Testing per ICC-ES AC308 Is Defined As: · Dry Concrete -- Cured concrete whose moisture content is in equilibrium with surrounding non-precipitate atmospheric conditions. · Water-Saturated Concrete -- Concrete that has been exposed to water over a sufficient length of time to have the maximum possible amount of absorbed water into concrete pores to a depth equal to the anchor embedment. · Submerged Concrete -- Water-saturated concrete that is fully submerged at the time of hole drilling and anchor installation. · Water-Filled Hole -- Drilled hole in water-saturated concrete that is clean yet contains standing water at the time of installation. Appendix S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 213 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Alphabetical Index of Products 3GWSP Opti-Mesh Adhesive-Anchoring Screen Tube 36 ADT Acrylic Dispensing Tool 29 AMN Acrylic Mixing Nozzle 30 ARC Adhesive Retaining Caps 35 AT-XP Acrylic Adhesive 26 ATR All Thread Rod 41 ATS Acrylic Screens 38 AWSP Opti-Mesh Adhesive-Anchoring Screen Tube 36 CD Crimp Drive® Anchor 102 CDT10S Adhesive Dispensing Tool 28 CI-SLV Super-Low-Viscosity Injection Epoxy 140 CI-LV Low-Viscosity Injection Epoxy 142 CI-LV FS Low-Viscosity Fast-Setting Injection Epoxy 144 CI-LPL Low-Viscosity Long-Pot-Life Injection Epoxy 146 CI-GV Gel-Viscosity Injection Epoxy 148 CIP-F Crack Injection Paste Over 154 CIP-LO Low Odor Crack Injection Paste Over 154 CPFH Crack-Pac® Flex-H2OTM Crack Sealer 152 CSD Countersunk Split Drive 105 CSS V-WrapTM Composite Strengthening SystemsTM 172 DIA Drop-In Anchor 94 DIAB Drop-In Anchor 88 DSD Duplex Head Split Drive 105 EDT Epoxy Dispensing Tool 28 EIF Injection Fitting 156 EIP Injection Port 156 EMN Epoxy Mixing Nozzle 30 ET-HP® Epoxy Adhesive 24 ETB Hole-Cleaning Brush 32 Alphabetical Index of Products 214 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Alphabetical Index of Products ETBR ETBS ETIPAC ETR ETS EWSP EZAC E-Z-ClickTM GAC GCC GCL GCN-MEP GCT GDP GDPS GDPSK GFC GMR GRH GTH GTS GW GWL HDIA HELI P22AC P25SL P27LVL P27SL Hole-Cleaning Brush Hole-Cleaning Brush Crack-Pac® Injection Epoxy Concrete Repair and Paste-Over Epoxy Epoxy Screens Opti-Mesh Adhesive-Anchoring Screen Tube Easy-Set Pin-Drive Anchor Injection System Gas-Actuated Ceiling 90° Clip Gas-Actuated Conduit Clip Gas-Actuated Conduit Clamp Gas-Actuated Concrete Nailer Gas-Actuated Tie-Strap Holder Collated Gas-Drive Pins Collated Gas-Drive Step-Shank Pins Collated Spiral-Knurled Gas Pins Gas Fuel Cell Magnetic Ring for GCN-MEPMAGKT Gas-Actuated Threaded Rod Hanger Gas-Actuated Top-Hat Pin Gas-Actuated 1/4" Threaded Stud Gas-Actuated Dome Washer Pin Lathing Washer for GCN-MEPMAGKT Hollow Drop-In Anchor Heli-Tie Helical Wall and Stitching Tie 0.22 Caliber "A" Crimp Loads -- Single Shot 0.25 Caliber Plastic 10-Shot Strip Loads 0.27 Caliber Single-Shot Loads -- Long 0.27 Caliber Plastic 10-Shot Strip Loads S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 32 31 150 155 38 36 71 156 119 119 119 114 119 116 116 117 118 117 119 119 119 119 117 96 166 129 129 130 130 215 Alphabetical Index of Products Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Alphabetical Index of Products PBXDP PCC PCL PCLDPA PDPA PDPAS PDPAT PDPAWL PECLDPA PEPT PHBC PHD PHT-38 PINW PINWP PKP PP PPFT PSLV3 PT-22A PT-22HA PT-27 PTP-27L PTRHA RFB RND RSH RSV RWH BX Cable Strap 135 Conduit Clip 135 90° Ceiling Clip (no pin) 133 90° Ceiling Clip Angle with Pin 133 0.157" Shank Diameter Drive Pin 132 Collated 0.157" Shank Diameter Drive Pin 133 0.157" Shank Diameter Top-Hat Fastener 133 0.157" Shank Diameter with 1" Metal Washer 132 120° Ceiling Clip Angle with Pin 133 Extension Poles for PT-27, PTP-27L and GCN-MEPMAGKT 120 Highway Basket Clip 135 1/4"-Headed Hammer Drive Fastener 136 Manual Hammer Tool 136 0.145" Shank Diameter Drive Pin with 1 7/16" Metal Washer 134 0.145" Shank Diameter Drive Pin with 13/8" Plastic Washer 134 Concrete Forming Pin 136 Piston Plug 33 Piston Plug Flexible Tubing 34 3/8" Threaded Stud 135 0.22 Cal. Powder-Actuated Tool 126 0.22 Cal. Single-Shot Hammer-Actuated Tool 128 0.27 Cal. Semi-Automatic Powder-Actuated Tool 124 0.27 Cal. Automatic Powder-Actuated Tool 122 0.157" Shank Diameter Threaded Rod Hanger 134 Retrofit Bolt 40 Rod Hanger Nut Driver 83 Steel Rod Hanger Horizontal 83 Steel Rod Hanger Vertical 83 Wood Rod Hanger Horizontal 86 Alphabetical Index of Products 216 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Alphabetical Index of Products RWV Wood Rod Hanger Vertical 86 SDS-max® Drill Bits 181 SDS-plus® Drill Bits 178 SET-3GTM Epoxy Adhesive 20 SET-XP® Epoxy Adhesive 22 SL Sleeve-All® Anchor 68 STB2 Strong-Bolt® 2 Wedge Anchor 64 STB2 SS Strong-Bolt 2 Type 304 Stainless-Steel Wedge Anchor 64 SWN Sure Wall Anchor Nylon 107 SWZ Sure Wall Anchor Zinc 107 THD Titen HD® Heavy-Duty Screw Anchor 52 THD CS Titen HD Countersunk Screw Anchor 54 THD CS SS Stainless-Steel Titen HD Countersunk Screw Anchor 60 THD RC Titen HD Rod Coupler 62 THD RH Titen HD Rod Hanger 81 THD SS Stainless-Steel Titen HD Heavy-Duty Screw Anchor 58 THD-WH Titen HD Washerhead Screw Anchor 55 TNT Titen TurboTM Screw Anchor 74 TTN SS Titen® Stainless-Steel Concrete and Masonry Screw 79 TW Tie Wire Anchor 73 ZN Zinc NailonTM 100 Alphabetical Index of Products S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. 217 Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry Notes 218 S-A-PG22 © 2022 SIMPSON STRONG-TIE COMPANY INC. Strength runs in the family. The Titen® family of concrete and masonry anchoring solutions from Simpson Strong-Tie. Our broad range of versatile and innovative screw anchors is designed for maximum ease and efficiency -- ensuring a quick, smooth installation every time. And our skilled field support teams are always available to assist on the jobsite. To learn more about our full line of easy-to-install Titen solutions, visit go.strongtie.com/titenfamily or call (800) 999-5099. S-A-PG22 Effective 6/1/22 Expires 12/31/25 © 2022 Simpson Strong-Tie Company Inc.iLovePDF