DEWALT DS610 Wireless Indoor Motion Sensor

NOTE: This product works only with the DS600 Mobilelock Portable Alarm System.

GENERAL SAFETY RULES

⚠ WARNING: Read and understand all instructions and warnings for this product.

In addition, read and follow all instructions and warnings provided with the DS600 Mobilelock Portable Alarm System.

CAUTION: DANGER OF EXPLOSION, INJURY, OR FIRE.

Carefully follow all instructions and warnings on the battery label and package.

  • Never use a damaged or worn out battery.
  • Discharged batteries should be replaced only with type CR-123 3.0 Volt Lithium batteries.
  • Do not use re-chargeable batteries or attempt to change batteries.
  • Carefully remove the old, discharged battery.
  • Do not attempt to open battery.
  • Do not peel the label from the battery.
  • Never dispose of a battery in a fire.
  • Dispose of used batteries in accordance with local regulations.
  • Recycle batteries.
  • Always insert batteries correctly with regard to polarity (+ and -) marked on the battery and the equipment.
  • When installing the battery, do not use excessive force. If the battery does not fit, check to make sure that it matches the polarity markings.
  • Never expose the battery terminals to any other metal object. This can short circuit the battery.
  • Avoid exposure to temperature extremes.
  • When not in use store the battery in a cool, dark, dry place.
  • Keep batteries out of reach of children.

CAUTION: POTENTIAL EQUIPMENT MALFUNCTION OR FAILURE. Do not touch the electronic components inside the device, except the reset button and battery.

Components (Refer to Figure 1 for visual layout)

Figure 1 illustrates the DS610 sensor with its key components:

  • A. Sensitivity Dial
  • B. Reset Button
  • C. Tamper
  • D. Battery
  • E. Additional Alerts
  • F. Walk Test Button

Product Function (Refer to Figure 2 for detection pattern)

The DS610 Indoor Motion Sensor – PIR (Passive Infrared) is a low-current motion detector extremely sensitive to moving heat sources. This sensor provides a 50' (15.24m) range of protection with advanced digital scanning to recognize human movements and size to help prevent false alarms.

Figure 2 illustrates the detection pattern of the DS610. From a top view, the sensor covers a wide arc, extending up to 50-60 feet. From a side view, the detection pattern shows coverage from 2.1m (approximately 7 feet) up to 50-60 feet, indicating a conical or fan-shaped detection area.

NOTE: The DS610 signals an alert when motion is detected by the sensor. Once an alert is signaled, further alerts are inhibited for 90 seconds. This feature is designed to conserve battery life. Once activated, this device will work exclusively with the assigned DS600 Mobilelock GPS Locator with Anti-Theft Alarm.

  • The DS610 features BLE (Bluetooth Low Energy) that allows it to connect wirelessly to and only to the DS600 Mobilelock. Range between this sensor and the DS600 can be up to 100' if unobstructed (line of sight).
  • The DS610 features a tamper (C) that notifies the system when the sensor cover is removed.
  • The DS610 device uses a CR-123 3.0V Lithium battery (D) for long life.
  • The reset button (B) should be depressed after each time a battery is inserted.

NOTE: Metal objects blocking radio frequency (RF) transmission can affect the range of the sensor.

Prevention of False Alarms

The majority of alarms that occur are false. These situations happen every day due to user error, incorrect installation or improper maintenance of the system. False alarms will limit the responsiveness to the system and become a general inconvenience. As the number of false alarms increases, authorities have become less apt to respond to alarm systems due to this problem. Many of these situations can be avoided by following some very simple practices.

  • Ensure all users are properly trained on the operation of the system.
  • Always Disarm the DS600 Mobilelock before entering protected area.
  • Lock all protected doors, windows or any other asset attached to a sensor.
  • Check that motion detectors are not obstructed. Do not install them facing a window or near a heating/air conditioning vent.
  • Check that premises are cleared and assets secured before Arming the system.
  • Turn off all noise sources – radios, compressors, generators, heavy equipment, etc.
  • Know how to cancel an alarm or turn off the system before activating.
  • Test the system on a monthly basis to ensure proper functioning.
  • Check cellular signal, power supply, and that sensors are secured on a daily basis.

Recommended Locations

Recommended for use in enclosed areas, offices, climate controlled storage, and monitoring interior spaces.

  • The DS610 functions best when areas being protected are bounded by solid barriers. Walls and floors provide good back-drops for detecting moving heat (infrared) sources.
  • For best detection, locate the motion sensor so that intruders move across detection zone patterns, rather than toward or away from the sensor (refer to Figure 2).
  • Check areas for potential sources of false alarms. Remember that the sensor responds to quick changes in heat patterns within its coverage pattern. Avoid placing in direct or reflected sunlight, or near objects that can be heated quickly by sunlight. Do not place the DS610 looking at windows. Do not place it near heating or cooling sources, like heater ducts or air conditioners, which might direct hot or cold air onto the sensor. Avoid appliances such as space heaters which can rapidly heat up.
  • Take into consideration the normal use of the area. Are there bats, mice or other animals that could activate the sensor?
  • Do not obstruct the coverage pattern with furniture or other equipment.

Installing & Changing Battery

This wireless sensor requires a non-rechargeable CR-123 3.0 Volt Lithium battery.

CAUTION: POTENTIAL EQUIPMENT MALFUNCTION OR FAILURE. Do not touch the electronic components inside the device, except the reset button and battery.

TO INSTALL BATTERY

  1. Using a flat screwdriver, open the housing. Insert the screwdriver about .25" (6mm) at the tab on the bottom of the unit (refer to Figure 3). The screwdriver will enter the slot at about a 45° angle. Pry downward on the handle of the screwdriver until the latch holding the cover to the housing base releases.
  2. Install the battery using the polarity (+ and -) markings on the battery and equipment. Do not use excessive force. If the battery does not fit, ensure that it matches the polarity markings (refer to Figure 1).
  3. Press the Reset Button (B) on the device. After resetting the sensor (see Device Registration), replace the cover.

TO CHANGE THE BATTERY

CAUTION: Never use a damaged or worn-out battery.

  1. Carefully remove the old, discharged battery. Dispose of the battery according to local regulations.
  2. Install new battery using the polarity (+ and -) markings on the battery and equipment. Do not use excessive force. If the battery does not fit, ensure that it matches the polarity markings (refer to Figure 1).
  3. Press the Reset Button (B) on the device. After resetting the sensor, replace the cover.

Device Registration

To activate this sensor, it must first be assigned to the DS600 Mobilelock Device. Instructions for assigning your sensor can be found within your online Mobilelock account.

NOTE: This sensor can be assigned to only one DS600 Mobilelock device at a time.

  1. Log into your online Mobilelock account.
  2. Select the Mobilelock device you wish to pair this sensor to and go to the Configure Units page.
  3. Click the link titled "Manage Bluetooth" in the Sensors section.
  4. Click to "Enable" Bluetooth.
  5. After the Mobilelock device's Bluetooth is confirmed "Enabled", click "Add Sensor". After the battery is installed in the sensor hold it close to the DS600 and click "Scan for available sensors".
  6. When the website shows the sensor click on it to confirm your selection.
  7. Then configure the sensor: Give it a name (e.g., "Downstairs Motion").
  8. Select any optional alerts desired and click "Save and Close".
  9. Make sure the sensor is selected as "Enabled".
  10. After registration, Arm the DS600 Mobilelock and test the sensor.

WALK TEST

DS610 walk test mode is a feature available to help confirm the proper location for installation. With the cover off hold down the button found in the lower left of the board until a double beep is heard. More than two beeps may be heard since it will be detecting motion as soon as this mode is enabled. Now replace the cover and place in the proposed location. Enter and leave the detection zone and listen for the beep. Every time motion is detected there will be a beep followed by a 1 to 2 second mask period as the detector re-arms. This will continue for approximately 5 minutes. After the allotted time, the DS610 will sound a series of at least 3 rapid beeps and will automatically leave test mode and resume normal operating mode.

Mounting

  • The DS610 has two mounting holes on the back of the sensor for easy installation. Use two #8 screws or mounting tape (not provided). For mounting tape placement, see Figure 4.
  • Mount the sensor 3-6' (.9-1.8m) from the floor. Any height outside of this range will decrease the sensitivity of the motion detector.
  • Be sure that the sensor is secure so it will not be bumped or otherwise moved.

Figure 4 shows the back of the DS610 sensor with an area indicated for mounting tape, suggesting a flat surface for attachment.

Adjustable Sensitivity

  • The DS610 is factory set to a motion sensitivity that is best for most applications. To make it more or less sensitive to motion detection, turn the sensitivity dial (A).
  • This adjustment changes the analog amplifier gain which will increase or decrease the detection range.
  • Turn to less sensitive to reduce false alarms.

Adding LED flash and/or Buzzer with motion

Audible and visual alerts (E) can be added whenever motion is detected.

  • #1- BUZZER: Enables audible "BEEP" indication when motion alarm has been tripped.
  • #2 - LED: Enables RED LED that will flash when motion alarm has been tripped.

Note: Switching #1 and/or #2 to ON will increase battery drain and shorten battery run time.

Adding a Filter

  • #3- FILTER (E): When ON, a two-phase digital filter is employed to reduce false alarms from transient electrical noise. OFF removes the filter and is the most sensitive.

Full One Year Warranty

The DeWALT Mobilelock Portable Alarm System is warranted for one year from date of purchase. Mobilelock LLC will repair, without charge, any defects due to faulty materials or workmanship. For warranty repair information, visit www.dewaltmobilelock.com or email info@dewaltmobilelock.com. This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives specific legal rights and there may be other rights which vary in certain states or provinces.

PDF preview unavailable. Download the PDF instead.

DS610 Redesign Instruction Manual FINAL ?v=1622569302 Microsoft Word for Microsoft 365

Related Documents

Preview DeWalt DCH273 18V Cordless Hammer Drill | SDS Plus, Brushless, Tool Only
Explore the DeWalt DCH273, an 18V cordless SDS Plus hammer drill featuring a brushless motor. This catalog entry details specifications, package contents (tool only, 1 battery, case), and key features for professional use.
Preview DEWALT D1000 Series Full Body Adjustment Harness Instruction Manual
Comprehensive instruction manual for the DEWALT D1000 Series Full Body Adjustment Harness, covering safety, applications, inspection, donning, fitting, maintenance, and technical specifications. Includes warnings and guidelines for safe use.
Preview DEWALT DCD991 & DCD996 Cordless Drill/Driver/Hammerdrill Instruction Manual
Comprehensive instruction manual for DEWALT DCD991 and DCD996 20V Max* Brushless Cordless Drill/Driver and Hammerdrill. Includes safety guidelines, operating instructions, maintenance, and warranty information.
Preview DEWALT Jobsite Pro-X1 True Wireless Earbuds Instruction Manual
Learn how to use and troubleshoot your DEWALT Jobsite Pro-X1 True Wireless Earbuds with Charging Case. This manual covers setup, controls, pairing, technical specifications, and safety guidelines for the DXMA1902092 model.
Preview DEWALT AC200+ Adhesive Anchoring System with Smooth Dowel Bars Technical Data
Technical specifications and performance data for the DEWALT AC200+ Adhesive Anchoring System when used with smooth dowel bars, including bond capacity and embedment details.
Preview DEWALT DCS438 Cut Off Tool: User Manual and Safety Instructions
This document provides comprehensive user instructions, safety warnings, technical specifications, and operating guidelines for the DEWALT DCS438 Cut Off Tool. It covers safe usage, maintenance, and product details for professional and consumer users.
Preview DEWALT DC900-XE Heavy-Duty 36V Cordless Hammerdrill Instruction Manual
Official instruction manual for the DEWALT DC900-XE Heavy-Duty 36V Cordless Hammerdrill. Includes safety guidelines, operating instructions, maintenance, and warranty information.
Preview DeWALT Jobsite Pro Wireless Earphones Safety Recall
Safety recall notice for DeWALT Jobsite Pro Wireless Earphones due to overheating hazard. Affected models and contact information for free replacement are provided.