Immergas VICTRIX PRO V2: Light Commercial Condensing Gas Boiler

For 60 years, Immergas has been a leader in providing energy solutions. The VICTRIX PRO V2 is a new, BIM-ready wall-hung light commercial condensing gas boiler designed for efficient central heating in residential and commercial buildings, featuring Hydrogen Ready technology.

Product Overview

The VICTRIX PRO V2 is a modular condensing boiler with a sealed chamber and forced draught, designed for heating-only applications. It is ideal for centralized heating systems in residential and commercial buildings, offering high efficiency and flexibility.

The compact and linear design, featuring a vertical scrolling lid for panel protection, characterizes the entire VICTRIX PRO V2 range. The boilers are available in nine versions, with outputs ranging from 35 kW to 180 kW.

Key Features and Benefits

High Installation Flexibility

The VICTRIX PRO V2 offers significant installation flexibility thanks to its reduced dimensions. It supports 5-generator cascade installations, allowing for a total output of up to 900 kW. The design minimizes space requirements for cascade setups.

Floor-Standing and Outdoor Installation

Versions up to 150 V2 can be installed using a dedicated floor-standing support kit, suitable for linear or back-to-back arrangements in limited spaces. The structure includes supports for hydraulic manifolds and can be fixed to the floor or wall. The frame kit is also certified for outdoor installation. An optional cabinet kit allows for outdoor installation in a floor-standing configuration, with cascade setups possible using multiple cabinets. The boilers feature IPX5D protection and cataphoresis treatment for outdoor durability, with anti-freeze protection down to -15°C available with an optional kit.

High Performance and Efficiency

The wide modulation range, up to 1:10 (on the 120 kW version), optimizes generator performance even with low heating demands, such as during spring/autumn or partial system usage. The VICTRIX PRO V2 boilers achieve an A+ energy efficiency class when paired with an advanced Immergas thermoregulation panel, such as the Modulating Remote Panel (code 3.020358). The seasonal efficiency can reach 94% (up to the 120 V2 version).

Low NOx Emissions

The complete range meets NOx Class 6 standards for polluting emissions, making it suitable for buildings with high energy performance standards and a low environmental impact.

Hydrogen Ready Technology

VICTRIX PRO V2 boilers have obtained Hydrogen Ready certification, enabling them to operate with natural gas, LPG, and up to a 20% blend of hydrogen. This technology is presented as a key solution for reducing CO2 and greenhouse gas emissions, contributing to a zero-pollution future.

Advanced Components

The boilers feature a stainless steel condensing module with stainless steel hydraulic circuits (or composite plastic for certain models). The total pre-mixing combustion system allows for high output power modulation. Optimal regulation is achieved through two NTC temperature reading probes for precise control over functioning temperatures.

Technical Characteristics

The VICTRIX PRO V2 series incorporates a low-consumption modulating pump that adjusts speed to maintain a constant ΔT, reducing electrical absorption and noise. An integrated condensate discharge syphon ensures proper drainage. Safety valves are standard, rated at 4 bar for 35-80 models and 5.4 bar for 100-180 models. The new control electronics offer enhanced installation possibilities, managing up to two water distribution zones and a DHW circuit. It supports on/off thermostats or OpenTherm for temperature control and can manage DHW requests via an NTC sensor or on/off contact. An anti-legionella function is available with a tank probe. Timeslots for heating and DHW can be set (ECO, COMFORT, OFF).

Boiler cascade management is simplified with the Cascade and Zones Regulator Kit, allowing control over boiler activation, power, and sequence based on heat demand. The kit also facilitates management of thermal solar systems for DHW production. Remote monitoring is possible with an optional kit.

Main Characteristics Summary

Electrical connection to the master boiler Temperature settings Maximum number of boilers Water distribution zones Connection in series Thermal solar system connection
2 BUS wires: max length 50 meters Central heating: COMFORT, ECO, Anti-Freeze
DHW temperature
8 3 (1 direct and 2 mixed) + 1 DHW pump Up to n°3 Cascade and Zones Regulator kits and n°6 expansion kits. Only the master panel will be connected to the boiler Possibility to install and manage a thermal solar system without an additional external control unit

Technical Data

The following tables provide detailed technical specifications for the VICTRIX PRO V2 range.

VICTRIX PRO V2 EU - Models 35 to 80 kW

Technical characteristics Unit VICTRIX PRO 35 V2 EU VICTRIX PRO 55 V2 EU VICTRIX PRO 60 V2 EU VICTRIX PRO 68 V2 EU VICTRIX PRO 80 V2 EU
Natural gas boiler article number 3.034431 3.033857 3.033858 3.033859 3.033860
LPG gas boiler article number 3.034431GPL 3.033857GPL 3.033858GPL 3.033859GPL 3.033860GPL
Energy class A A A A A
Template article number 1.047417 1.047417 1.047417 1.047417 1.047417
Maximum heat input kW 34,9 51,0 59,9 65,0 75,0
Minimum heat input kW 3,9 5,4 7,8 7,8 7,8
Maximum effective heat output (80/60°C) kW 33,9 49,8 58,5 63,4 73,2
Minimum effective heat output (80/60°C) kW 3,7 5,1 7,5 7,5 7,5
Maximum effective heat output (50/30°C) kW 36,9 54,2 63,9 69,2 79,4
Minimum effective heat output (50/30°C) kW 4,1 5,7 8,3 8,3 8,3
Central heating seasonal efficiency ηs % 94 94 94 94 94
Efficiency at 100% Pn (80/60°C) % 97,0 97,6 97,7 97,5 97,6
Efficiency at 100% Pn (50/30°C) % 105,8 106,2 106,8 106,5 105,9
Efficiency at 100% Pn (40/30°C) % 107,7 106,8 108,3 107,8 105,8
Efficiency at partial load 30% (return flow temperature 30°C) % 109,2 109,6 109,6 109,4 109,5
Chimney losses with burner on (100% Pn) (80/60°C) % 2,69 2,3 2,2 2,3 2,3
Chimney losses with burner off % 0,03 0,02 0,017 0,020 0,01
Casing losses with burner on (100% Pn) (80/60°C) % 0,31 0,10 0,1 0,1 0,10
Casing losses with burner off % 0,32 0,23 0,2 0,2 0,16
NOx class 6 6 6 6 6
Weighted NOx mg/kWh 37 39 41 39 33
Weighted CO mg/kWh 27 24 17 17 24
Gas flow rate to burner at max, and min. heat output with methane (G20) m³/h 3,69/0,41 5,40/0,57 6,34/0,83 6,88/0,83 7,94/0,83
Maximum fan available head (max/min) Pa 86-2 197-2 195-4 230-4 306-3
Flue exhaust mass flow rate at nominal heat output (G20) kg/h 54/6 82/9 96/13 104/13 121/13
CO₂ at nominal/minimum heat output (G20) % 9,6/9,1 9,2/8,7 9,3/9,0 9,3/9,0 9,2/9,0
CO at nominal/minimum heat output (G20) mg/kWh 257/3 235/3 171/3 192/3 246/3
Maximum/Minimum fume temperature (G20) °C 79/60 74/60 71/65 74/65 79/65
Maximum operating temperature °C 95 95 95 95 95
Heating system adjustable temperature °C 15-90 15-90 15-90 15-90 15-90
Maximum operating pressure of heating circuit bar 4,4 4,4 4,4 4,4 4,4
Electric power supply V/Hz 230/50 230/50 230/50 230/50 230/50
Nominal power absorption A 1,0 1,8 2,2 2,3 2,5
Installed electric power W 130 158 295 300 320
Power absorbed by pump W 77,8 73,0 182,0 182,0 182,0
Power absorbed by fan W 45,0 65,0 95,0 103,0 120,0
Electrical insulation rating IP X5D X5D X5D X5D X5D
Full appliance weight (empty) kg 52,4 (50,0) 59,8 (57,0) 64,2(61,0) 64,2 (61,0) 64,2 (61,0)
Appliance water content litres 2,4 2,8 3,2 3,2 3,2

VICTRIX PRO V2 EU - Models 100 to 180 kW

Technical characteristics Unit VICTRIX PRO 100 V2 EU VICTRIX PRO 120 V2 EU VICTRIX PRO 150 V2 EU VICTRIX PRO 180 V2 EU
Natural gas boiler article number 3.033861 3.033862 3.033863 3.033864
LPG gas boiler article number 3.033861GPL 3.033862GPL 3.033863GPL 3.033864GPL
Energy class A A A A
Template article number 1.047417 1.047417 1.047417 1.047417
Maximum heat input (80/60°C) kW 93,0 114,5 141,0 170,0
Minimum heat input (80/60°C) kW 10,1 11,7 29,0 34,7
Maximum effective heat output (80/60°C) kW 90,9 112,3 138,3 166,9
Minimum effective heat output (80/60°C) kW 9,8 11,3 28,3 33,8
Maximum effective heat output (50/30°C) kW 98,8 121,7 149,9 180,2
Minimum effective heat output (50/30°C) kW 10,7 12,4 30,8 36,8
Central heating seasonal efficiency ηs % 94 94 93 93
Efficiency at 100% Pn (80/60°C) % 97,7 98,1 98,1 98,2
Efficiency at 100% Pn (50/30°C) % 106,2 106,3 106,3 106,0
Efficiency at 100% Pn (40/30°C) % 108,2 108,4 107,2 107,5
Efficiency at partial load 30% (return flow temperature 30°C) % 109,4 109,7 109,5 109,9
Chimney losses with burner on (100% Pn) (80/60°C) % 2,2 1,8 1,8 1,7
Chimney losses with burner off % 0,02 0,02 0,02 0,02
Casing losses with burner on (100% Pn) (80/60°C) % 0,10 0,10 0,10 0,10
Casing losses with burner off % 0,18 0,18 0,18 0,18
NOx class 6 6 6 6
Weighted NOx mg/kWh 34 30 34 42
Weighted CO mg/kWh 23 19 20 25
Gas flow rate to burner at max, and min. heat output with methane (G20) m³/h 9,84/1,07 12,12/1,24 14,92/3,07 17,99/3,67
Maximum fan available head (max/min) Pa 221-3 341-4 340-16 41-2
Flue exhaust mass flow rate at nominal heat output (G20) kg/h 149/17 185/19 226/48 277/60
CO₂ at nominal/minimum heat output (G20) % 9,3/8,9 9,2/8,9 9,3/8,9 9,1/8,5
CO at nominal/minimum heat output (G20) mg/kWh 235/7 219/4 230/7 224/11
Maximum/Minimum fume temperature (G20) °C 74/60 71/60 73/60 72/60
Maximum operating temperature °C 95 95 95 95
Heating system adjustable temperature °C 15-90 15-90 15-90 15-90
Maximum operating pressure of heating circuit bar 6 6 6 6
Electric power supply V/Hz 230/50 230/50 230/50 230/50
Nominal power absorption A 2,7 3,0 3,2 2,8
Installed electric power W 330 410 580 520
Power absorbed by pump W 183,0 183,0 258,0 298,0
Power absorbed by fan W 155,0 220,0 247,0 200,0
Electrical insulation rating IP X5D X5D X5D X5D
Full appliance weight (empty) kg 104,0 (95,0) 111,0 (101,0) 124,0 (112,0) 163,0 (148,0)
Appliance water content litres 9,0 10,0 12,0 15,0

Dimensions and Connections

Detailed dimensional drawings and connection specifications are provided for different model series.

VICTRIX PRO 35/55/60/68/80 V2 EU Dimensions and Connections

Key: V: Electrical connection, G: Gas supply, SC: Condensate drain (minimum internal diameter Ø 13 mm), M: System flow, R: System return, A: Air intake, A/S: Intake/expulsion.

Connections: Gas G: 3/4", System R: 1½", System M: 1½".

Separator kit distances: Ø 80/80.

Concentric kit dimensions: Ø 80/125.

VICTRIX PRO 100/120/150 V2 EU Dimensions and Connections

Key: V: Electrical connection, G: Gas supply, SC: Condensate drain (minimum internal diameter Ø 13 mm), M: System flow, R: System return, A: Air intake, A/S: Intake/expulsion, P: VICTRIX PRO 100/120 V2 mm 557, B: VICTRIX PRO 100/120 V2 mm 250.

Connections: Gas G: 1", System R: 1½", System M: 1½".

Separator kit distances: Ø 100/100.

Concentric kit dimensions: Ø 110/160.

VICTRIX PRO 180 V2 EU Dimensions and Connections

Key: V: Electrical connection, G: Gas supply, SC: Condensate drain (minimum internal diameter Ø 13 mm), M: System flow, R: System return, A: Air intake, A/S: Intake/expulsion.

Connections: Gas G: 1", System R: 1½", System M: 1½".

Separator kit distances: Ø 160/160.

Performance Curves

The following graphs illustrate the head-flow rate performance curves for various VICTRIX PRO V2 models, indicating available head and pump power absorption at different speeds (100% and 77%).

Head-Flow rate curve VICTRIX PRO 35 V2 EU

Displays head in kPa against flow rate in l/h, with pump power absorption in Watts shown for 100% and 77% speeds.

Head-Flow rate curve VICTRIX PRO 55 V2 EU

Displays head in kPa against flow rate in l/h, with pump power absorption in Watts shown for 100% and 77% speeds.

Head-Flow rate curve VICTRIX PRO 80 V2 EU

Displays head in kPa against flow rate in l/h, with pump power absorption in Watts shown for 100% and 77% speeds.

Head-Flow rate curve VICTRIX PRO 100 V2 EU

Displays head in kPa against flow rate in l/h, with pump power absorption in Watts shown for 100% and 77% speeds.

Head-Flow rate curve VICTRIX PRO 120 V2 EU

Displays head in kPa against flow rate in l/h, with pump power absorption in Watts shown for 100% and 77% speeds.

Head-Flow rate curve VICTRIX PRO 150 V2 EU

Displays head in kPa against flow rate in l/h, with pump power absorption in Watts shown for 100% and 77% speeds.

Head-Flow rate curve VICTRIX PRO 180 V2 EU

Displays head in kPa against flow rate in l/h, with pump power absorption in Watts shown for 100% and 77% speeds.

Thermoregulation and Control Options

Immergas offers a range of thermoregulation devices to enhance seasonal efficiency. These include:

Stand Alone Installation (without Cascade and Zones Regulator Kit)

  • Remote Control: A modulating control unit for single temperature control systems. Requires Clip-in kit code 3.034122. Dimensions: 138 x 90 x 28 mm. Code: 3.020358.
  • Clip-in for VICTRIX PRO V2: For use with the remote control. Code: 3.034122.
  • CRONO 7: Weekly digital chronothermostat. Dimensions: 103 x 142 x 31 mm. Code: 3.021622.
  • CRONO 7 WIRELESS: Wireless weekly digital chronothermostat. Dimensions: 103 x 142 x 31 mm. Code: 3.021624.
  • External Probe Kit: Optimizes energy consumption by adjusting delivery temperature. Code: 3.015266.
  • System Delivery Probe Kit: Measures delivery temperature after the hydraulic manifold. Code: 3.024245.
  • DHW Probe Kit: Measures DHW temperature of a storage tank. Code: 3.025467.

Technical Note: When used without a Cascade and Zones Regulator, and with optional probe kits, the boiler can control DHW secondary pumps and HEATING SYSTEM secondary pumps (for 2 direct zones or 1 direct + 1 mixed). Simple cascades of up to 5 appliances with uniform power can also be controlled.

Cascade Installation with Cascade and Zones Regulator Kit

  • Cascade and Zones Regulator Kit: Manages up to 3 water distribution zones, external storage tank, and thermal solar for DHW. Requires a Clip-in kit (3.034122) for each boiler. Code: 3.034119.
  • Clip-in for VICTRIX PRO V2: For use with the Cascade and Zones Regulator kit. Code: 3.034122.
  • Expansion Kit for Cascade and Zones Regulator Kit: Manages up to 5 additional zones. Code: 3.034124.
  • Zone Manager Kit: Modulating temperature control with backlit display and remote management. Code: 3.034120.
  • Tools Kit for Tele-management 2.0 VICTRIX PRO V2: For remote system monitoring. Code: 3.034121.

Additional Thermoregulation Accessories

  • CRONO 7: Weekly digital chronothermostat. Code: 3.021622.
  • CRONO 7 WIRELESS: Wireless weekly digital chronothermostat. Code: 3.021624.
  • Flow Probe Kit: Manages delivery temperature. Code: 3.015267.
  • Storage Tank Probe Kit: Manages water tank temperature. Code: 3.015268.
  • Probe Kit for PT 1000 Solar Collector: Manages solar plant. Code: 3.019374.
  • External Probe Kit: Optimizes energy consumption. Code: 3.024511.

Flue Systems

Immergas offers a dedicated set of flue kits for air suction/fume exhaust, designed for high resistance to corrosion and ease of installation.

Flue Systems "GREEN SERIES" for VICTRIX PRO V2

Configuration B23 - Open Chamber, Fan Assisted

  • Vertical Terminal Outlet Kits: Available for Ø 80, Ø 100, and Ø 160 mm diameters, for roof discharge. Outdoor versions in stainless steel are also available.
  • Stub-pipe Kits: For air intake, available for Ø 80, Ø 100, and Ø 160 mm.
  • Horizontal Kits: For discharge into chimney or horizontally, available for Ø 80, Ø 100, and Ø 160 mm.
  • Extension Pipes Kits: Available in various lengths (0.5m, 1m, 2m) and diameters (Ø 80, Ø 100, Ø 160).
  • Bends Kits: 45°, 90°, and 87° bends available for different diameters.
  • Gasket Kits DN100: For VICTRIX PRO 100/120/150 V2.
  • Clapet Valve Kits: For outdoor installation, available in stainless steel for Ø 80 and Ø 125 mm.
  • Cover Kits: IPX5D protection kits for outdoor installation.

Configuration C - Sealed Chamber, Fan Assisted

  • Horizontal Concentric Kits: For Ø 80/125 and Ø 110/160 mm.
  • Vertical Concentric Kits: For Ø 80/125 and Ø 110/160 mm, available in black with converse for pitched roofs.
  • Flashing Kits: For flat roofs, available for Ø 80/125 mm.
  • Twin Pipes Complete Kits: For Ø 80/80, Ø 100/100, and Ø 160/160 mm.
  • Extension Pipes: Available in 1m and 2m lengths for Ø 80/125 and Ø 110/160 mm.
  • Bend Kits: 2 x 45° bends and 87° bends for Ø 80/125 and Ø 110/160 mm.
  • Gasket Kits: Available for various diameters.

Ducting Solutions: The ducting system allows reuse of internal space and is designed for vertical development compartments. Maximum allowed pipe lengths vary by model (e.g., 12m for 35/55 V2, 8m for 60/68/80 V2). Specific configurations for bends and kits are detailed.

Exhaust Manifolds

For installations in boiler rooms with multiple VICTRIX PRO V2 units (up to 5), Immergas supplies special exhaust manifolds in PP equipped with flue locks to prevent backflow. These are modular and available for two boilers or additional boilers.

  • Exhaust Manifold Kits: Available for Ø 160 mm (35-80 V2) and Ø 200 mm (100-150 V2) with flue lock DN 80/125. Additional kits for connecting more boilers are also available, including kits for 4 or 5 VICTRIX PRO 150 V2 units with Ø 250 mm manifolds.
  • Extension Pipes and Bends: Various lengths and bend types are available for flue manifolds.
  • Stub-pipe Kits: For air intake, available for Ø 80 and Ø 100 mm.

Option Kits

Immergas offers a wide range of optional accessories to enhance system functionality and reliability.

Cabinet Installation

  • VICTRIX PRO Cabinet Kit: For outdoor installation, includes support feet and a 180° opening door with lock. Code: 3.033680.
  • Hydraulic Manifold and Safety Kit for VICTRIX PRO V2 Cabinet: For single and cascade installations, includes manifold, safety kit, and condensate discharge manifold. Code: 3.033681.

Free-Standing Installation

  • "Free standing" Support Frame Kit: For VICTRIX PRO 35/55/60/68/80 V2 and 100/120/150 V2, designed for installations where wall mounting is not feasible. Approved for outdoor use. Codes: 3.032347 (35-80 V2), 3.033686 (100-150 V2).

Hydraulic Optional for Single Installation

  • Safety Kit Single Boiler: Includes thermometer, lock, thermostat, pressure switch, etc. Code: 3.023949.
  • Three-way Valve Kit: For connection to a separate storage tank. Code: 3.023950.
  • Hydraulic Manifold Kits: Available for different model series, sized for large thermal systems. Codes: 3.023951, 3.023952.
  • IPX4D Protection Box Kit: For single boiler safety kit. Code: 3.024028.
  • Adapter Kit: For replacement of older Immergas models. Code: 3.023966.
  • Anti-freeze Protection Kit: For -15°C. Code: 3.034125.
  • Condensate Neutralizers: Available for up to 80 kW and 180 kW, including granulate. Codes: 3.033687, 3.033688. Granulate for 180 kW: 3.034920.
  • Condensate Discharge Pump Kit: For installations with opposite slope. Code: 3.020002.
  • Magnetic Dirt Separator Kit: For single installation. Code: 3.033673.
  • Plate Heat Exchanger Kits: For single installation on the right side of VICTRIX PRO models. Codes: 3.033676, 3.033677.

Hydraulic Optional for Cascade Installation

  • Hydraulic Manifold Kits: Available for 2 boilers and additional boilers in cascade, for different model series (35-80 V2, 100-150 V2, 180 V2). Includes 2-way and 3-way interception valves and non-return valves. Codes: 3.032338, 3.033669, 3.023955 (Safety Kit), 3.033667, 3.033668, 3.034938, 3.034939, 3.023961 (Safety Kit DN 100), 3.024038 (IPX4D Protection Box).
  • Hydraulic Separators: For various kW ratings (100, 200, 350, 400, 600 kW) with different connector types. Codes: 3.020839, 3.021377, 3.021378, 3.023965, 3.023962.
  • Anti-freeze Protection Kit: Code: 3.034125.
  • Condensate Neutralizers: For up to 80 kW, 180 kW, and 1500 kW. Codes: 3.033687, 3.033688, 3.023662. Granulate for 180 kW: 3.034920.
  • Magnetic Dirt Separator Kits: For cascade installation. Codes: 3.033674, 3.033675.
  • Plate Heat Exchanger Kits: For cascade installation on the right side of VICTRIX PRO models. Codes: 3.033678, 3.033679.

PDF preview unavailable. Download the PDF instead.

catalogo VICTRIX PRO V2 EU Adobe PDF Library 17.0 Adobe InDesign 19.4 (Windows)

Related Documents

Preview Immergas VICTRIX PRO V2 EU: High Power Condensing Boilers
Discover the Immergas VICTRIX PRO V2 EU range of high-power, wall-hung condensing boilers. Engineered for efficiency, flexibility, and reduced emissions, these boilers are ideal for modern heating systems.
Preview Immergas VICTRIX PRO V2 EU: High Power Condensing Boilers Technical Sheet
Explore the Immergas VICTRIX PRO V2 EU range of high-power, wall-hung condensing boilers. Discover advanced features, technical specifications, installation flexibility, and environmental benefits for efficient heating solutions.
Preview Immergas VICTRIX PRO V2 EU: High Power Condensing Boilers Technical Sheet
Comprehensive technical sheet for the Immergas VICTRIX PRO V2 EU series of high-power, wall-hung condensing boilers. Details specifications, features, models (35-180 EU), installation options, accessories, and technical data for efficient heating solutions.
Preview IMMERGAS VICTRIX PRO V2 EU: Cazane pe gaz în condensare - Prezentare tehnică
Descoperiți gama de cazane pe gaz în condensare IMMERGAS VICTRIX PRO V2 EU. Aflați despre caracteristicile precum eficiența energetică ridicată, designul compact, flexibilitatea și pregătirea pentru hidrogen (până la 20%), potrivite pentru încălzirea rezidențială și comercială.
Preview Immergas VICTRIX PRO V2: Caldaie a Condensazione di Alta Potenza
La gamma VICTRIX PRO V2 di Immergas offre caldaie a condensazione pensili ad alta potenza per riscaldamento efficiente. Ideali per grandi spazi residenziali, commerciali e industriali, vantano ampia modulazione, basse emissioni, flessibilità di installazione e compatibilità con miscele di idrogeno.
Preview Specifiche Tecniche Caldaie a Condensazione Immergas VICTRIX PRO V2 EU ad Alta Potenza
Scopri la gamma di caldaie a condensazione murali ad alta potenza Immergas VICTRIX PRO V2 EU. Offrono elevate prestazioni, flessibilità di installazione e soluzioni efficienti per il riscaldamento residenziale e commerciale.
Preview Immergas VICTRIX PRO V2 EU: Caldaie a Condensazione Murali ad Alta Potenza
Scopri la gamma di caldaie a condensazione murali ad alta potenza Immergas VICTRIX PRO V2 EU. Soluzioni efficienti per riscaldamento domestico, commerciale e industriale, con modulazione avanzata e basse emissioni.
Preview Immergas Victrix Pro IPX5D Outdoor Cover Kit Installation Guide
This document provides installation instructions for the Immergas Victrix Pro IPX5D outdoor cover kit, detailing the assembly process and compatible boiler models.