ProCon® -- TB550 Series
Turbidity Sensor
Quick Start Manual

SS316 POM

RoHS
Compliant

Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice.

24-0321 © Icon Process Controls Ltd.

1

ProCon® -- TB550 Series
Turbidity Sensor
Product Introduction
3/4" NPT Thread

POM SS316 Body

SS316 Body

Fully Automatic Electrode Scraper

Dual Beam with Quartz Glass Lens

The turbidity sensor is based on infrared scattered light technology .The infrared light emitted by the light source will be scattered when it passes through the sample under test during transmission. The intensity of the scattered light is directly proportional to the turbidity.
The turbidity sensor is equipped with a scattered light receiver in a 90° direction. The turbidity value is obtained by analyzing the intensity of the scattered light. It can be widely used for turbidity monitoring in sewage plants, water plants, water stations, surface water and other industrial applications.

Technical Specifications

Sensor Model No. Power Supply Accuracy Pressure Range Working Temperature Measurement Range Output Resolution Response Time Waterproof Grade Housing Material Connection Cable Length Installation

TB550 9-36VDC ±5% of Measured Value 43.5Psi 32 - 113oF | 0 - 45oC 0.01-4000NTU MODBUS RS485 0.001 | 0.01 | 0.1 | 1 , When Matching the Controller 6s < 90s < 300s (Adjustable) IP68 | NEMA6P SS316L, POM 3/4" NPT 10m Immersed

24-0321 © Icon Process Controls Ltd.

2

ProCon® -- TB550 Series
Turbidity Sensor
Installation
Immerse the sensor into the sample and ensure that the tip is fully installed so as to avoid the sensor head being affected by air bubbles.

Calibration

The turbidity sensor has been calibrated before leaving the factory. Self-calibration is rarely required. If calibration is necessary, please see the standard liquid that is required for suspension concentration calibration. The specific configuration is as follows.
Preparation Method (Turbidity Standard Liquid 200mL 4000NTU) :

Serial No.

Material

Ammonium Chloride

A

Hydrazine Sulfate, N2H6SO4 (GR)

5.00g

B

Methenamine, C6H12N4 (AR)

50.00g

1. Accurately weigh 5.000g of Hydrazine Sulfate (GR) and dissolve it in zero turbidity water. The solution is then transferred to a 500ml volumetric flask, diluted to scale, shaken and filtered (filtered with 0.2m aperture, same below).
2. Accurately weigh 50.000g of Methenamine (AR), dissolve it in zero turbidity water and transfer it into a 500ml volumetric flask, dilute to scale, shake well.
3. Preparation of 4000NTU Formazine Standard Solution: Transfer 100ml of each of the above two solutions into a 200ml volumetric flask which is placed in a 25 ± 1°C incubator or constant temperature water bath. Let stand for 24 hours to make 4000NTU standard solution.

Turbidity Standard Solution
The total preparation volume was 200ml.

No.

Concentration (NTU)

1

10

2

100

3

400

4

700

5

1000

400NTU Absorb Quantity (ml) 2.5 2.5 ­ ­ ­

4000NTU Absorb Quantity (ml) ­ 2.5 10
17.5 25

24-0321 © Icon Process Controls Ltd.

3

ProCon® -- TB550 Series
Turbidity Sensor
Formulation Formula: A=K*B/C
 A: Absorb quantity (ml)  B: Concentration of the solution required to be formulated (NTU)  C: Proto-standard liquid concentration (NTU)  K: Total amount of preparation (ml) Example: 10 NTU turbidity standard solution configuration method Dissolve 2.5ml (The concentration was 400 NTU) solution transfer to a 100ml volumetric flask, add deionized water or distilled water and dilute to a 100ml scale line, shake well and use to measure.
Sensor Calibration 1. Sensor Read
Connect the digital turbidity sensor to the computer through the Modbus RS 485, and open the Modbus debugging software: mbpoll.exe, Set the address 1,9600, N, 8,1, then select "Float" at "Display", as shown in the figure below; where 00002 shows the temperature value, that is, the ambient temperature of the turbidity sensor is 14.5oC, 00004 shows the turbidity value, where the aqueous solution in which the turbidity sensor is located is 20.7 NTU.
2. Manual Start Brush
As shown in the figure below, after connecting the turbidity sensor, select 06 function code in the communication software, Address input: 20, Value input 66, click Send, to observe the sensor brush start.

24-0321 © Icon Process Controls Ltd.

4

ProCon® -- TB550 Series
Turbidity Sensor
3. Set Up Brush Time
As shown in the figure below, after connecting the turbidity sensor, select 06 function code in the communication software, Address input: 21, Value input 30, click Send, and the wiper of the sensor will start every 30 minutes. If you do not require the wiper, an input of 0 needs to be entered in the Value line.
4. Read the Automatic Brush Time
As shown in the figure below, after connecting the turbidity sensor, select Display in the communication software and select Signed (integer), and the communication address 11 displays 30, indicating that the sensor starts the scraping every 30 minutes.

24-0321 © Icon Process Controls Ltd.

5

ProCon® -- TB550 Series
Turbidity Sensor
5. Sensor Calibration
Connect the turbidity sensor to the computer. Select "Setup- -Poll Definition", then select 03 function code, Address: 100, Length: 60. Prepare the known concentration of the standard solution, stir well,. Place the turbidity sensor and double-click the calibration point address on the computer to view the dialog box. Input the standard liquid value. After confirming the sensor will begin to automatically calibrate, the calibration result is the corresponding voltage address bit data. The calibration is complete after 10s voltage stabilization.
Example : To calibrate the turbidity sensor of range 0-400 NTU, the calibration solution prepared is 250 NTU. Select the 06 function code, Address input is 00138, that is, the 9th calibration point, then enter 250 in the Value. After the voltage value of the 00150 is stable, the calibration is completed.

6. Change Sensor Address
After connecting the sensor and MODBUS software, select "06" function code, enter "17" in "Address", "Value" in "2" or the mailing address to be modified, click "Send", a popup shows "Response OK", indicating the sensor address modification is completed. Without knowing the sensor communication address, the sensor can be read using the broadcast address 255.

24-0321 © Icon Process Controls Ltd.

6

ProCon® -- TB550 Series
Turbidity Sensor
7. Read Instruction Parsing
The communication protocol adopts MODBUS (RTU) protocol. The communication content and address can be changed according to the customer's needs. The default configuration is network address 01, port rate 9600, no check, a stop bit. Users can set the change; Function code 04 instruction for example:  Temperature value =14.8ºC, Turbidity value=17.0NTU;  Host sent: FF 04 00 00 00 08 XX XX  Slave reply: FF 04 10 00 00 00 00 3E 8A 41 6D F9 6B 41 87 9C 00 44 5E XX XX Explanation:  [FF] Represents the sensor address address  [04] Represents function code 04  [10] Represents have 16 bytes of data  [3E 8A 41 6D]=14.8; | Temp. value; parsing order:41 6D 3E 8A  [09 18 41 88]=17.0; | Turbidity value; parsing order:41 88 09 18  [XX XX] Represents the CRC 16 check code.
8. Restore Factory Calibration
If the digital turbidity sensor calibration is wrong during the calibration process, select "06" function code, enter "200" in "Address" , "60" in "Value" , click "Send". A pop-up display "Response OK" appears.

24-0321 © Icon Process Controls Ltd.

7

ProCon® -- TB550 Series
Turbidity Sensor

Sensor Wiring
Color Red Black Green White

Description +VDC -VDC
RS485A RS485B

Maintenance
In order to obtain the best measurement results, regular maintenance is required. Maintenance mainly includes the sensor cleaning, check whether the sensor is damaged. The associated state of the sensor can also be viewed during maintenance and detection.
Sensor Cleaning
The two lenses on the sensor need to be cleaned. Please make regular cleaning and maintenance according to the actual use situation to ensure the accuracy of measurement. When cleaning, first rinse with clean water, and then use detergent & cloth to wipe inorder to remove stubborn stains.
Inspection of Sensor Damage
Check the appearance of the sensor. If there is any damage, contact ICON at 905-469-7283 to replace it in time to prevent the fault caused by water filling of the sensor due to damage.

Communication Protocol
The sensor is equipped with MODBUS RS485 communication function.

Sensor Read Address | Funciton Code 04 | Communication Configuration: 9600 N 8 1

Add

Items

Value

Authority

Type

Description

0

Reserved

2

Temperature

Read-Only Single Float

4

Turbidity

Sensor Calibration Address | Function Code 03

Add

Items

Value

Read-Only Single Float

Authority

Type

Range

11

Brush Time

0

Read-Write

Integer

1 - 10080 | Unit : Min

17

Address

20

Manual Brush

1

Read-Write

Integer

1 - 254

0

Write-Only

Signed

Send 66

21

Automatic Brush

0

Write-Only

Signed

1 - 10080 | Unit : Min

24-0321 © Icon Process Controls Ltd.

8

ProCon® -- TB550 Series
Turbidity Sensor

Sensor Calibration Address | Function Code 0x03 Read | Function code 0x10 Fix

Add

Items

Range

Authority

100

First Calibration Point

Read-Write

102

Fifth Calibration Point

104

Eighth Calibration Point

According to the Range

Read-Write Read-Write

106

Tenth Calibration Point

Read-Write

108

First Voltage

Read-Write

110

Fifth Voltage A

Read-Write

112

Fifth Voltage B

Read-Write

114

Eighth Voltage A

Read-Write

116

Eighth Voltage B

Read-Write

118

The Tenth Voltage

Read-Write

120

Dynamic Correction

0.000

Read-Write

122

Linear Compensation

1.000

Read-Write

124

Temperature Correction

0.000

Read-Write

126

Temperature Setting

25.0

Read-Write

128

Second Calibration Point

Read-Write

130

Third Calibration Point

Read-Write

132

Fourth Calibration Point

Read-Write

134

Sixth Calibration Point

Read-Write

136

Seventh Calibration Point

Read-Write

138

Ninth Calibration Point

Read-Write

140

Second Voltage

Read-Write

142

Third Voltage

Read-Write

144

Fourth Voltage

Read-Write

146

Sixth Voltage

Read-Write

148

Seventh Voltage

Read-Write

150

Ninth Voltage

Read-Write

200

Factory Calibration

60

Write-Only

Type Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float Single Float
Integer

Only Calibration Values are
Restored

24-0321 © Icon Process Controls Ltd.

9

ProCon® -- TB550 Series
Turbidity Sensor
Warranty, Returns and Limitations
Warranty
Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement.
Returns
Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective, go to www.iconprocon.com, and submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment.
Limitations
This warranty does not apply to products which: 1) are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2) have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3) have been modified or altered; 4) anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5) have been involved in accidents or natural disasters; or 6) are damaged during return shipment to Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1) there is evidence of a potentially hazardous material present with the product; or 2) the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada.
If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty.
For additional product documentation and technical support visit:
www.iconprocon.com | e-mail: sales@iconprocon.com or support@iconprocon.com | Ph: 905.469.9283

24-0321 © Icon Process Controls Ltd.

10



References

Adobe PDF Library 17.0 Adobe InDesign 19.4 (Windows)