Immergas VICTRIX PRO Range: Light Commercial Condensing Boilers

An overview of Immergas's advanced condensing boiler solutions for light commercial applications.

About Immergas

Immergas, founded on February 5, 1964, has a long history of developing reliable products in the Italian style. The company operates in over 40 countries with 9 branches and numerous partnerships, consistently investing in facilities and technology. Immergas focuses on environmental attention and consumption reduction through new technologies, emphasizing collaboration with installers and end customers.

VICTRIX PRO Range: Overview

The VICTRIX PRO range consists of wall-hung modular condensing boilers designed exclusively for heating. These boilers offer high heating output, a wide modulating ratio, and high efficiency, making them ideal for residential and commercial buildings, as well as private homes due to their new design and compact dimensions.

Key Features:

Models in the range include:

Model names indicate maximum boiler heating outputs at delivery/return temperatures of 50/30 °C.

Comfort & Technology

The VICTRIX PRO range offers advanced comfort and technology:

Support for Professionals

Immergas provides a technical team to offer guidance and regulations for the design and layout of hydraulic and electrical plant schemes, ensuring professionals get the most out of the VICTRIX PRO solutions.

Advantages

.01 New Control Panel

The boiler features a user-friendly control panel with a vertically sliding door protecting the display and board. It includes simple buttons and a backlit display.

High Seasonal Efficiency

The 1:10 modulation range optimizes generator function, even with reduced heating requirements during mid-seasons or in multi-zone systems.

New Remote Control

An optional kit allows exclusive communication with the cascade and zone regulator for remote control of the central heating system.

Complete Range of Optionals

A comprehensive selection of optional components is available to complete the central heating system, including hydraulic components, thermoregulation devices, flue systems, and condensate neutralizers.

.02 Modular Installation

Up to 5 boilers can be installed hydraulically in cascade, enabling high power outputs up to 700 kW.

Installation on Supporting Frame

VICTRIX PRO boilers can be installed on modular supporting frames, individually or in batteries of up to 5 units, in linear or back-to-back arrangements. Frames are equipped for hydraulic manifolds and can be wall or floor-mounted. They are also approved for outdoor installation.

Ideal Also for Outdoor Installations

High electrical protection (IPX5D) and cataphoresis treatment on the frame make VICTRIX PRO suitable for outdoor installations.

Technical Characteristics

.03 Module for Condensation in Stainless Steel

The condensation modules feature a stainless steel hydraulic circuit. For VICTRIX PRO 35 and 55 1 I versions, the outer shell is composite. It is crucial to thoroughly clean and flush the central heating system before fitting a VICTRIX PRO, using a cleaning agent and inhibitor to preserve system components like pipes and heat exchangers.

.04 Combustion System and Total Premixing

Advanced combustion system development allows a modulation field from 10% to 100% of thermal power across the range. Generators can operate on natural gas or LPG.

Integrated Trap for Condensation Disposal

A built-in trap collects condensation and ensures regular drainage via a polypropylene hose resistant to condensate action. Acid condensation discharged externally must comply with regulations.

Low Emissions of NOx and CO Pollutants

The range achieves a Class 5 rating for pollutant emissions, making it suitable for installations requiring high energy performance and low environmental impact.

Optimum Control of Adjustment

Two NTC probes (in delivery and return) ensure optimum control of the operating temperature.

Production of Domestic Hot Water Integrated with Solar Systems

VICTRIX PRO boilers can be combined with Immergas solar solutions for domestic hot water production, particularly with storage tanks of 200, 300, 500, 1000, 1500, and 2000 liters.

.05 Easy Control of Boilers in Cascade Installations

A cascade and zone regulator manages, controls, and programs boiler sequences, determining which boiler starts, its output, and operating sequence based on heating system demand.

Control of Solar Systems for Domestic Hot Water Production

The cascade regulator facilitates management of thermal solar systems for D.H.W. production, with special control probes available (see page 17).

Main Features (Cascade/Solar Control)

Electrical connection to the main boiler Temperature setting No. of boilers manageable Manageable zones Connection in series Connection to a solar system
2 BUS cables: max distance 50 meters Room heating: Comfort, less antifreeze
D.H.W. setting
8 3 (2 of which mixed) + 1 boiler unit Up to 5 cascade regulators of which only the main regulator (master) will be connected on the boiler Possibility of setting solar circuit parameters without the need of extra control units

.06 Remote Control of Heating System

The cascade and zone regulator allows connection via Ethernet to a company network or through a router/modem to an ADSL line, accessible via Internet Explorer.

GSM/GPRS Connection

If no ADSL line is available, the remote control gateway can connect to a router (modem with SIM card) for GSM/GPRS connection.

Technical Data

Detailed technical specifications for VICTRIX PRO models (35 1 I to 120 1 I) are provided in the table below, covering CE certificate, heat output, efficiency, losses, NOx class, gas flow rates, fan head, flue exhaust, CO2/CO levels, temperatures, pressure, power supply, insulation rating, weight, and water capacity.

Code Unit of measurement VICTRIX PRO 35 1 I VICTRIX PRO 55 1 I VICTRIX PRO 80 1 I VICTRIX PRO 100 1 I VICTRIX PRO 120 1 I
N.G. L.P.G.3.024488
3.024488GPL
3.024489
3.024489GPL
3.024490
3.024490GPL
3.024491
3.024491GPL
3.024492
3.024492GPL
CE certificate0051CO44050051CO44050051CO44050051CO44050051CO4405
Maximum heat outputkW34,951,375,392,3114,1
Minimum heat outputkW3,95,57,69,411,4
Maximum nominal heat output (80/60 °C)kW34,049,973,090,0111,0
Maximum nominal heat output (50/30 °C)kW37,354,880,398,8121,7
Minimum nominal heat output (80/60 °C)kW3,45,07,29,011,0
Minimum nominal heat output (50/30 °C)kW3,75,58,110,112,2
Efficiency at nominal heat output (80/60 °C)%97,397,397,097,597,3
Efficiency at minimum heat output (80/60 °C)%86,391,294,896,296,4
Efficiency at nominal heat output (50/30 °C)%107,0106,8106,6107,0106,7
Efficiency at minimum heat output (50/30 °C)%94,799,7106,9107,4107,2
Efficiency at nominal heat output (40/30 °C)%107,3107,4107,3107,4107,2
Efficiency at minimum heat output (40/30 °C)%100,2103,5107,2107,6107,5
Stack losses with burner on 100% Pn (80/60 °C)%1,61,82,21,92,0
Stack losses with burner OFF%0,040,030,010,010,01
Casing losses with burner ON 100% Pn (80/60 °C)%1,10,90,80,60,7
Casing losses with burner OFF%0,440,300,340,410,28
NOx class55555
Weighted NOxmg/kWh25,039,025,020,033,0
Weighted COmg/kWh8,015,016,012,018,0
Gas flow rate to burner at max, and min. heat output with methane (G20)m³/h3,70 - 0,425,44 - 0,587,96 - 0,809,77 - 0,9912,07 - 1,21
Maximum fan available head (max/min)Pa50/1110/1230/6208/4145/5
Flue exhaust mass flow rate at nominal heat output (G20)Kg/h5581115144178
CO₂ at nominal/minimum heat output (G20)%9,40/9,109,40/9,109,85/8,859,60/8,909,60/9,00
CO at 0% of O₂ (G20)ppm84157229180190
Maximum fume temperature°C4852625456
Maximum operating temperature°C9090909090
Heating system adjustable temperature°C20-8520-8520-8520-8520-85
Maximum operating pressure of heating circuitbar4,44,44,44,44,4
Electric powerV/Hz230 - 50230 - 50230 - 50230 - 50230 - 50
Max power supplyW140195290370440
Electrical insulation ratingIPX5DX5DX5DX5DX5D
Gross weightkg51,251,481,095,9102,5
Boiler water capacitylitres2,82,84,010,111,7

Dimensions and Connections

VICTRIX PRO 35/55

Diagram Description: Front and side views of the VICTRIX PRO 35/55 boiler showing dimensions and connection points. Key labels include V (Electrical connection), G (Gas supply), SC (Condensate drain Ø 13 mm), M (System delivery), and R (System return). Key dimensions are provided in mm. The diagram also shows horizontal outlet kits (Ø 80) and horizontal concentric kits (Ø 80/125).

Flow Rate/Head Graph: A graph illustrates the relationship between flow rate (l/h) and head (kPa) for the VICTRIX PRO 35/55, showing performance at top speed and second speed.

Hydraulic Connections:

Gas Heating Condensate drain
G (3/4")R (1 1/2"), M (1 1/2")SC (25 mm)

VICTRIX PRO 80

Diagram Description: Front and side views of the VICTRIX PRO 80 boiler, similar to the 35/55 model, detailing dimensions and connection points (V, G, SC, M, R). Key dimensions are provided in mm. Horizontal outlet kits (Ø 80) and horizontal concentric kits (Ø 80/125) are also illustrated.

Flow Rate/Head Graph: A graph shows the flow rate (l/h) versus head (kPa) for the VICTRIX PRO 80, differentiating between top speed and second speed.

Hydraulic Connections:

Gas Heating Condensate drain
G (3/4")R (1 1/2"), M (1 1/2")SC (25 mm)

VICTRIX PRO 100/120

Diagram Description: Front and side views of the VICTRIX PRO 100/120 boilers, showing dimensions and connection points (V, G, SC, M, R). Key dimensions are provided in mm. Horizontal outlet kits (Ø 80) and horizontal concentric kits (Ø 80/125) are illustrated.

Flow Rate/Head Graphs: Two graphs display the flow rate (l/h) versus head (kPa) for VICTRIX PRO 100 and VICTRIX PRO 120 respectively, indicating performance at top and second speeds.

Hydraulic Connections:

Gas Heating Condensate drain
G (1")R (1 1/2"), M (1 1/2")SC (25 mm)

Thermoregulation System

Systems of Control and Heat Adjustment for Individual Installation

Various accessories are available for individual installations to optimize climate management:

Type Description Code
Remote control for single VICTRIX PROModulating control unit for optimizing room temperature management. For systems with a single temperature control.3.020358
CRONO 7 (weekly digital chronothermostat)ON-OFF control based on time and temperature settings (comfort and economy).3.021622
CRONO 7 WIRELESS (wireless weekly digital chronothermostat)Same functions as CRONO 7, usable where wired connection is impossible.3.021624
External probeOptimizes energy consumption by correcting delivery temperature for smooth operation.3.015266
System delivery probe kit for the boiler (available in June 2014)Measures delivery temperature after the hydraulic manifold.3.024245
Anti freeze protection kit -15 °CFor outdoor installations, usable down to -15 °C.3.024513

Systems of Control and Heat Adjustment for Installation in Battery

For central heating systems or cascade installations, these accessories manage heat adjustment and climatic regulation:

Type Description Code
Cascade and zone regulator kitManages VICTRIX PRO in cascade (max 8 boilers), controls climatic zones (max 3 + 1 for hot tap water).3.015244
Wall box kit for cascade and zone regulatorFor installing the cascade and zone regulator inside an electrical box.3.015265
Zone manager kitElectrically connected to cascade/zone regulator, manages climatic conditions of one zone, allows remote control.3.015264
Modulating room thermostatManages climatic conditions of one zone, allows room temperature control only.3.015245
Flow probePositioned on the delivery pipe, allows control of system and mixed zone temperatures.3.015267
Storage tank sensor kit (for managing the storage tank as a zone)Manages storage tank as a zone, connected to cascade regulator. Two probes needed for solar installations.3.015268
Solar collector temperature probe kitPositioned on solar manifolds, controls solar fluid temperature.3.019374
External probeOptimizes energy consumption by correcting delivery temperature for smooth function.3.024511
Anti freeze protection kit -15 °CFor outdoor installations, usable down to -15 °C. One kit per boiler.3.024513
Tele-management kitConnects cascade and zone regulator to Ethernet or ADSL for remote system connection.3.024244

Optional Hydraulic Accessories

For Single Installation

Type Description Code
Safety kit single boilerIncludes thermometer, lock, thermostat, pressure gauge tap, pressure switch, gas intercepting valve, expansion vessel connection, minimum pressure switch. Insulation standard.3.023949
Three-way valve kit connection to a separate storage tankIncludes storage tank probe. Power supply 230 Vac. Insulation standard.3.023950
Hydraulic manifold kit for VICTRIX PRO 35-55Specially sized for large thermal systems with high water content. Equipped with sludge collection filter. Insulation standard.3.023951
Hydraulic manifold kit for VICTRIX PRO 80-100-120Insulation standard.3.023952
IPX4D protection box kit for single boiler safety kit3.024028
By-pass kit for VICTRIX PRO 35-55For systems where hydraulic flow is under 850 l/h (without hydraulic manifold). Insulation standard.3.024677
Condensate neutralizer kit for single installationNeutralizes condensation acidity. Includes granulate.3.019857
Granulate for condensate neutralizerExtra granulate for condensation passivator kit.3.019865
"Free standing" support frame kit VICTRIX PRODesigned for situations where wall mounting is not possible. Modular construction. Approved for outdoor installation.3.024246

For Cascade Installation

Type Description Code
Hydraulic manifold kit G 2 1/2" for 2 VICTRIX PRO 35/55 in cascadeKit for connecting 2 VICTRIX PRO 35/55 boilers in cascade. Includes 2-way valves, 3-way interception valve, non-return valve per generator. Insulation standard.3.023953
Hydraulic manifold kit G 2 1/2" for additional VICTRIX PRO 35/55 in cascadeConnects 3 to 5 VICTRIX PRO 35/55 boilers in cascade (one kit per additional boiler). Includes 2-way interception valve, 3-way interception valve, non-return valve. Insulation standard.3.023954
Safety kit G 2" ½ for VICTRIX PRO 35/55 in cascadeIncludes thermometer, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection, and pressure switch for minimum pressure. Insulation standard.3.023955
Hydraulic manifold kit DN 100 for 2 VICTRIX PRO 80/100/120 in cascadeKit to connect 2 VICTRIX PRO 80/100/120 boilers in cascade. Includes 2-way interception valve, 3-way interception valve, and non-return valve per generator. Insulation standard.3.023959
Hydraulic manifold kit DN 100 for additional VICTRIX PRO 80/100/120 in cascadeIn combination with kit 3.023959, connects 3 to 5 VICTRIX PRO 80/100/120 boilers in cascade (one kit per additional boiler). Includes 2-way interception valve, 3-way interception valve, and non-return valve. Insulation standard.3.023960
Safety kit DN 100 for VICTRIX PRO 80/100/120 in cascadeIncludes thermometer, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection, and pressure switch for minimum pressure. Insulation standard.3.023961
IPX4D protection box kit for cascade safety kit3.024038

Hydraulic Optional for Cascade Installation

Type Description Code
Condensate neutralizer kit for cascade installationNecessary to neutralize condensation acidity. Inclusive of granulate.3.019464
Granulate for condensate neutralizerExtra granulate for condensation passivator kit (suggest buying 2 kits for cascade installation).3.019865
Hydraulic separator for 100 kW installationsSeparator with G2 1/2" threaded connectors. Insulation as standard.3.020839
Hydraulic separator for 200 kW installationsSeparator with G2 1/2" threaded connectors. Insulation as standard.3.021377
Hydraulic separator for 400 kW installationsSeparator with G2 1/2" threaded connectors on boiler side - DN 100 on system side. Insulation as standard.3.021378
Hydraulic separator for 350 kW installationsSeparator with threaded connectors - DN 100. Insulation as standard.3.023965
Hydraulic separator for 600 kW installationsSeparator with threaded connectors - DN 100. Insulation as standard.3.023962
"Free standing" support frame kit VICTRIX PRODesigned for situations where wall mounting is not possible. Modular construction. Approved for outdoor installation.3.024246

Flue System

"Green Series" Fitted Flue System

VICTRIX PRO boilers are approved type "B23" (open chamber, fan assisted), requiring a single flue exhaust outlet. This can be configured as "C" for sealed chamber operation. The kits offer high resistance to corrosion and ease of installation.

Configuration B23 - Open Chamber, Fan Assisted

Maximum flue distances (metres) for various outlet types:

Type VICTRIX PRO 35 1 I VICTRIX PRO 55 1 I VICTRIX PRO 80 1 I VICTRIX PRO 100 1 I VICTRIX PRO 120 1 I
Terminal vertical outlet kit Ø 80 (Code 3.015256)243028148,5
Terminal vertical outlet outdoor kit Ø 80 (Code 3.024295)243028148,5
Horizontal kit Ø 80 (to discharge in the chimney) (Code 3.015254)243028148,5
Terminal horizontal outlet kit Ø 80 (to discharge horizontally) (Code 3.015255)243028148,5

Configuration C - Sealed Chamber, Fan Assisted

Maximum flue distances (metres) for various outlet types:

Type VICTRIX PRO 35 1 I VICTRIX PRO 55 1 I VICTRIX PRO 80 1 I VICTRIX PRO 100 1 I VICTRIX PRO 120 1 I
Vertical concentric kit Ø 80/125 (Code 3.015243)11,51815116
Horizontal concentric kit Ø 80/125 (Code 3.015242)814,41185

* Additional flue system parts may decrease maximum admissible length.

Cascade Installation - "Green Series" Exhaust Manifolds

For cascade installations (up to 5 units), Immergas supplies special exhaust manifolds with flue lock to prevent backflow. The system is modular, with kits for two boilers and for additional boilers.

Type Description Code
Exhaust manifold kit 2 VICTRIX PRO 35/55 Ø 160 with flue lockServes for exhaust connection of two boilers in cascade.3.024279
Exhaust manifold kit 2 VICTRIX PRO 80/100/120 Ø 200 with flue lockServes for exhaust connection of two boilers in cascade.3.024281
Additional exhaust manifold kit VICTRIX PRO 35/55 Ø 160 with flue lockFor connection of an additional boiler (see also page 23).3.024280
Additional exhaust manifold kit VICTRIX PRO 80/100/120 Ø 200 with flue lockFor connection of an additional boiler (see also page 23).3.024282
Additional exhaust manifold kit VICTRIX PRO 100/120 Ø 250 with flue lock for 4 VICTRIX PRO 100/1203.024666
Additional exhaust manifold kit VICTRIX PRO 100/120 Ø 250 with flue lock for 5 VICTRIX PRO 100/1203.024667
Extension pipe Ø 160 kit 0,5 m long for flue manifold3.024659
Extension pipe Ø 200 kit 0,5 m long for flue manifold3.024663
Extension pipe Ø 160 kit 1 m long for flue manifold3.024516
Extension pipe Ø 200 kit 1 m long for flue manifold3.024662
Extension pipe Ø 250 kit 1 m long for flue manifold3.024668
87° bend kit Ø 160 for flue manifold3.024517
87° bend kit Ø 200 for flue manifold3.024665
87° bend kit Ø 250 for flue manifold3.024670
No. 2 45° bend kit Ø 160 for flue manifold3.024518
No. 2 45° bend kit Ø 200 for flue manifold3.024664
No. 2 45° bend kit Ø 250 for flue manifold3.024669

Exhaust Manifold Kit Quantities for Cascade Installations:

VICTRIX PRO 35/55

Number of boilers Exhaust manifold kit 2 VICTRIX PRO 35/55 Ø 160 with flue lock (Code 3.024279) Additional exhaust manifold kit VICTRIX PRO 35/55 Ø 160 with flue lock (Code 3.024280)
2 VICTRIX PRO 35-5511
3 VICTRIX PRO 35-5512
4 VICTRIX PRO 35-5513
5 VICTRIX PRO 35-5514

VICTRIX PRO 80/100/120

Number of boilers Exhaust manifold kit 2 VICTRIX PRO 80/100/120 Ø 200 with flue lock (Code 3.024281) Additional exhaust manifold kit VICTRIX PRO 80/100/120 Ø 200 with flue lock (Code 3.024282)
2 VICTRIX PRO 8011
3 VICTRIX PRO 8012
4 VICTRIX PRO 8013
5 VICTRIX PRO 8014

VICTRIX PRO 100/120 (using Ø 200 and Ø 250 kits)

Number of boilers Exhaust manifold kit 2 VICTRIX PRO 100/120 Ø 200 with flue lock (Code 3.024281) Additional exhaust manifold kit VICTRIX PRO 100/120 Ø 200 with flue lock (Code 3.024282) Additional exhaust manifold kit VICTRIX PRO 100/120 Ø 250 with flue lock for 4 VICTRIX PRO 100/120 (Code 3.024666) Additional exhaust manifold kit VICTRIX PRO 100/120 Ø 250 with flue lock for 5 VICTRIX PRO 100/120 (Code 3.024667)
2 VICTRIX PRO 100-1201
3 VICTRIX PRO 100-12011
4 VICTRIX PRO 100-120111
5 VICTRIX PRO 100-1201111

Dimension Diagrams

Single Installation

VICTRIX PRO 35/55: Diagrams show front and side views with dimensions and connection points (Boiler, Safety kit, Three-way valve kit, Hydraulic separator, External probe, CRONO 7). Key connections are labeled for Storage tank delivery/return and System delivery/return.

VICTRIX PRO 80/100/120: Diagrams show front and side views with dimensions and connection points (Boiler, Safety kit, Three-way valve kit, Hydraulic separator, External probe, CRONO 7). Key connections are labeled for Storage tank delivery/return and System delivery/return.

Cascade Installation

5 VICTRIX PRO 35/55: Diagram illustrates a cascade setup of five boilers, showing dimensions and connections for Boiler, Hydraulic manifold kit, Safety kit, Hydraulic separator, Condensate neutralizer kit, Exhaust manifold kit, Cascade and zone regulator kit, Flow probe, External probe, and Storage tank sensor kit. Includes connection to a Unit DHW tank.

5 VICTRIX PRO 80/100/120: Diagram illustrates a cascade setup of five boilers, showing dimensions and connections for Boiler, Hydraulic manifold kit, Safety kit, Hydraulic separator, Condensate neutralizer kit, Exhaust manifold kit, Cascade and zone regulator kit, Flow probe, External probe, and Storage tank sensor kit. Includes connection to a Unit DHW tank.

Cascade Installation - "Free Standing" Support Frame

5 VICTRIX PRO 35/55 - "FREE STANDING" SUPPORT FRAME INSTALLATION: Diagram shows a cascade setup of five boilers on a free-standing frame, detailing dimensions and connections for all components, including connection to a Unit DHW tank.

5 VICTRIX PRO 80/100/120 - "FREE STANDING" SUPPORT FRAME INSTALLATION: Diagram shows a cascade setup of five boilers on a free-standing frame, detailing dimensions and connections for all components, including connection to a Unit DHW tank.

PDF preview unavailable. Download the PDF instead.

CARACTERISTICI-TEHNICE-IMMERGAS-GAMA-VICTRIX-PRO Adobe InDesign CS6 (Macintosh) Adobe PDF Library 10.0.1

Related Documents

Preview Immergas VICTRIX PRO RANGE: High-Efficiency Condensing Boilers
Discover the Immergas VICTRIX PRO RANGE of wall-hung modular condensing boilers, offering high heating output, wide modulation, and energy efficiency for residential and commercial applications. Learn about their features, installation flexibility, and technical specifications.
Preview Immergas Victrix Pro Plate Heat Exchanger Kit Installation Guide
This document provides installation instructions and technical data for the Immergas Victrix Pro plate heat exchanger kits, designed for use with Victrix Pro boilers. It includes safety warnings, installation procedures, technical specifications, and pressure drop graphs.
Preview Immergas VICTRIX PRO V2 EU: High Power Condensing Boilers
Discover the Immergas VICTRIX PRO V2 EU range of high-power, wall-hung condensing boilers. Engineered for efficiency, flexibility, and reduced emissions, these boilers are ideal for modern heating systems.
Preview Immergas VICTRIX PRO V2: High-Efficiency Light Commercial Condensing Gas Boilers
Discover the Immergas VICTRIX PRO V2 series, a range of wall-hung condensing gas boilers designed for light commercial and residential applications. Featuring high efficiency, hydrogen-ready technology, and flexible installation options, these boilers offer advanced performance and environmental benefits.
Preview Immergas VICTRIX PRO V2 EU: High Power Condensing Boilers Technical Sheet
Explore the Immergas VICTRIX PRO V2 EU range of high-power, wall-hung condensing boilers. Discover advanced features, technical specifications, installation flexibility, and environmental benefits for efficient heating solutions.
Preview Immergas VICTRIX PRO V2 EU: High Power Condensing Boilers Technical Sheet
Comprehensive technical sheet for the Immergas VICTRIX PRO V2 EU series of high-power, wall-hung condensing boilers. Details specifications, features, models (35-180 EU), installation options, accessories, and technical data for efficient heating solutions.
Preview Immergas VICTRIX PRO V2: Caldaie a Condensazione di Alta Potenza
La gamma VICTRIX PRO V2 di Immergas offre caldaie a condensazione pensili ad alta potenza per riscaldamento efficiente. Ideali per grandi spazi residenziali, commerciali e industriali, vantano ampia modulazione, basse emissioni, flessibilità di installazione e compatibilità con miscele di idrogeno.
Preview Immergas VICTRIX PRO 2 ErP Condensing Boilers: Technical Specifications and Manual
Explore the Immergas VICTRIX PRO 2 ErP series of wall-hung condensing boilers. This technical manual details specifications, dimensions, installation, and features for models 35-55, 80, 100, and 120 ErP, highlighting their high efficiency and versatility for various heating needs.