Important Safety Instructions
- WARNING: RISK OF ELECTRIC SHOCK - The pump must not be used while people are inside the pool.
- WARNING: TO REDUCE THE RISK OF INJURY - Do not permit children to use this product unless they are closely supervised at all times.
- WARNING: RISK OF ELECTRIC SHOCK - Connect only to a grounding type receptacle protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI.
- CAUTION – To reduce the risk of electric shock, the pool must be installed no closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.
- DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.
- WARNING - To reduce the risk of electric shock, the supply cord cannot be replaced. If the cord is damaged, the appliance should be scrapped.
- WARNING- To reduce the risk of electric shock, do not use an extension cord to connect the unit to the electric supply; provide a properly located outlet.
- CAUTION: This pump is for use with storable pools only. Do not use with permanently-installed pools.
- CAUTION- For continued protection against possible electric shock, this unit is to be mounted to the base in accordance with the installation instructions.
- IMPORTANT- Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of the pump.
- RISK OF ELECTRIC SHOCK- When working with electricity, turn the electrical power off at the circuit breaker and lock the breaker door. Failure to do so will result in increased risk of shock, injury, and possibly death.
- DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related to the validity of your plugs grounding.
Handle the pump with care. Do not pull or carry the pump by the power cord. Never pull a plug from the outlet by yanking the power cord. Keep cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the filter pump.
NOTE: Please examine equipment before use. Notify Bestway at the customer service address listed on this manual for any manufacturing defect or missing parts at the time of purchase. Verify that the equipment components represent the filter pump model that you had intended to purchase.
NOTE: Place pump on a solid and level ground. Pay attention to the position of the pool and pump so adequate ventilation, drainage, and access for cleaning is available. Never place the pump in an area that may accumulate water, or in an area where foot traffic will flow around the pool.
NOTE: Atmospheric conditions may affect the performance and life span of your filter pump. Unnecessary wear and tear may occur during periods of cold, heat, and exposure to sun. Whenever possible, shelter the pump from these conditions.
NOTE: Do not add chemicals in the filter pump.
NOTE: Assembly and disassembly by adults only.
The pump is to be supplied by an isolating transformer or supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA.
WARNING-This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Electric installations should follow national wiring rules; consult a qualified electrician with any questions.
- THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3
- FOR USE WITH SWIMMING POOLS ONLY.
- CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
- WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING TYPE RECEPTACLE PROTECTED BY A GROUND-FAULT CIRCUIT INTERRUPTER (GFCI).
- CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO NOT USE WITH PERMANENTLY-INSTALLED POOLS.
- CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
- CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC SHOCK, THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
SAVE THESE INSTRUCTIONS.
Parts Diagram and Assembly
The manual includes a parts list with corresponding part numbers and diagrams illustrating the assembly process. Key components include various seals, hoses, and the filter cartridge. The assembly steps are shown in numbered diagrams, indicating how to connect the pump to the pool and secure it.
Parts List:
Part Number | A | B | C | D | E | F |
P05425 | 1 | 1 | 1 | 1 | 1 | 1 |
P6(H1)115ASS16 | 1 | 1 | 1 | 1 | 1 | 1 |
P6119ASS16 | 1 | 1 | 1 | 1 | 1 | 1 |
90357 | 1 | 1 | 1 | 1 | 1 | 1 |
P06040 | 1 | 1 | 1 | 1 | 1 | 1 |
P6019ASS16 | 2 | 2 | 2 | 0 | 0 | 0 |
P6(H1)517ASS16 | 2 | 2 | 2 | 2 | 2 | 2 |
P6124ASS16 | 5 | 4 | 2 | 2 | 0 | 0 |
P6005ASS16 | 2 | 2 | 2 | 0 | 0 | 0 |
P6029ASS16 | 3 | 3 | 3 | 2 | 2 | 0 |
P6916ASS16 | 2 | 0 | 0 | 2 | 0 | 0 |
P61408ASS16 | 1 | 1 | 1 | 0 | 0 | 0 |
P6680ASS16 | 2 | 2 | 0 | 0 | 0 | 0 |
P61318ASS16 | 1 | 0 | 0 | 1 | 0 | 0 |
P61322ASS16 | 0 | 0 | 0 | 1 | 0 | 0 |
Assembly Steps:
- Diagrams show the connection of hoses and the filter pump to the pool structure.
- Specific part numbers are indicated for each connection point.
- Pedestal fixing is detailed, requiring two 9mm diameter holes spaced 163mm apart on a stable base weighing over 18kg.
Operation
- Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is released as water fills the Filter Pump.
- When water comes out of the Air Purge Valve, screw it closed and wipe away any water.
- To start the Filter Pump, insert the plug.
Pump Maintenance
- CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
- Unplug the Filter Pump.
- Stop water flowing to the Filter Pump (refer to pool's manual).
- Unscrew the Filter Cap Retainer and remove the Filter Cap.
- Clean the Filter Cartridge with a garden hose. If the filter cartridge remains soiled or discolored, it is necessary to replace it with a new one.
- Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
- Check that the Filter Cap Seal is in place.
- Replace the Filter Cap and screw the Filter Cap Retainer into position.
- Open the Valve A and B.
- Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT: To ensure pool water stays clean, please clean the filter cartridge every day. For sanitary reasons, it is suggested to replace the filter cartridge with a new one every two weeks.
Pump Storage
- Unplug the Filter Pump.
- Stop water flowing into the Filter Pump and remove the Filter Cartridge.
- Discard the Filter Cartridge.
- Detach all Hoses.
- Dry all components thoroughly.
- Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-40°C (39.2-104°F).
- Drain the pool according to the Pool Owner's Manual.
Pump Warranty
For information concerning pump warranty, please visit the Bestway website at: www.bestwaycorp.com
Manufacturer Information
©2020 The Coleman Company, Inc. Coleman® is a registered trademark of The Coleman Company, Inc., used under license. Manufactured by Bestway. ©2021 Bestway (USA) Inc. Trademarks used in some countries under license from Bestway Inflatables & Material Corp., Shanghai, China. Exported by Bestway (Hong Kong) International Ltd./Bestway Enterprise Company Limited, Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon, Hong Kong. www.bestwaycorp.com