File Info : application/pdf, 4 Pages, 663.93KB
DocumentDocumentInstallation and Setting Instructions TP6000M & TP6000MA Electronic Programmable Thermostats Specification Power supply: 230 volt powered models - 20-250 Vac, 50/60Hz Temperature range: Off-5-30°C Temperature accuracy: ± 0.5°C Voltage rating of contacts: 20-250 Vac, 50/60Hz Current rating of contacts: 0mA - 3A resistive, A inductive Switching action: Voltage free SPDT contacts, Type B Time accuracy: ± minute Memory retention: 5 days IP rating: IP30 Dimensions (mm): 30 x 00 x 38 (W x H x D) Control pollution situation: Degree 2 Rated impulse voltage: 2.5 KV Ball pressure test: 75°C Ordering Details Type TP6000M TP6000MA Code No. 087N728600 087N728700 Description 5/2 day programmable room thermostat with built-in sensor 5/2day programmable room thermotat with remote sensor Applications + or - Installation 1. Thermostat Location 2. Unpacking the Thermostat 3. Separating the Wallplate 4. Fitting the Thermostat to the Wall 5. Wiring Access - Incorrect 6. Wiring Access - Correct 2 7. Cable Size Max cable size .5mm2 Wiring Connections DIL Switch Settings (see rear of circuit board) ON/OFF 4 EVENTS EACH DAY * CHRONOPROPORTIONAL 2 EVENTS EACH DAY Fitting the Thermostat to the Wallplate Ensure unit is firmly in place 3 Danfoss can accept no responsibilty for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed. Danfoss Randall Limited Ampthill Road, Bedford, MK2 9ER Tel: (023) 3662 Fax: (023 29705 Email: danfossrandall@danfoss.com Website: www.danfoss-randall.co.uk Part No: 33075v0 0/07