EBERLE Thermostats: EU Regulation 2024/1103 Compliance
This document details the compliance of EBERLE Controls GmbH thermostats with EU Regulation 2024/1103, outlining their control functions and technical specifications.
Product Information
Manufacturer: EBERLE Controls GmbH
Address: Klingenhofstraße 71, 90411 Nürnberg
Model Identification: FR-E 525 31/i, FR-E 525 31/i 30°C
These regulators fulfill the following control functions as per EU Regulation 2024/1103:
- TE: (1/0/0/0/0/0/0/8)
- i.V.m. ext. Wochenzeitschaltuhr: TW (0/0/0/0/0/0/0/8)
Power Consumption
Specification | Symbol | Value | Unit | Description | |
---|---|---|---|---|---|
Off-state | PO | N/A | W | Single-stage heating, no room temperature control | No |
Standby state | PSM | 0.39 | W | Two or more manual stages, no room temperature control | No |
Idle state | Pidle | N/A | W | Room temperature controller with mechanical thermostat | No |
Networked standby operation | PNSM | N/A | W | Electronic room temperature controller | Yes |
Standby state with information or status display | Electronic room temperature controller with time-of-day control | No | |||
Electronic room temperature controller with weekly control | No |
Control Functions and Codes
Table 7 details the codes for the control functions:
Type of Temperature Control | Control Code (TC) | Control Functions | |||||||
---|---|---|---|---|---|---|---|---|---|
f1 | f2 | f3 | f4 | f5 | f6 | f7 | f8 | ||
Single-stage, no temperature control | NC | ||||||||
Two or more manual stages, no temperature control | TX | ||||||||
Room temperature controller with mechanical thermostat | TM | ||||||||
Electronic room temperature controller | TE | ||||||||
Electronic room temperature controller with time-of-day control | TD | ||||||||
Electronic room temperature controller with weekly control | TW | ||||||||
Control Functions | Presence detection | 1 | |||||||
Open window detection | 2 | ||||||||
Remote control option | 3 | ||||||||
Adaptive learning of the heating start | 4 | ||||||||
Operating time limitation | 5 | ||||||||
Black bulb sensor | 6 | ||||||||
Self-learning function | 7 | ||||||||
Control accuracy with CA < 2 Kelvin and CSD < 2 Kelvin | 8 |
Other Control Options
Specification | |
---|---|
Presence detection | Yes |
Open window detection | No |
Remote control option | No |
Adaptive learning of the heating start | No |
Operating time limitation | No |
Black bulb sensor | No |
Self-learning function | No |
Control accuracy | Yes |