Preventa XCS-E XCSE7312 Safety Interlock Switch

Product Sheet Characteristics

XCSE7312

Preventa XCS-E - Metal safety position switch with key - 2NC+1NO 24V - 2xM20

Main Features

Product RangePreventa Safety Detection
Product FunctionSafety Interlock Switch
Component NameXCSE
Detector DesignRectangular
MaterialMetal
Head TypeKey Turret
Contact Description2 NC + 1 NO
Contact OperationSlow break, without short-circuit contact
Solenoid Contact Type and Composition1 NO + 1 NC (slow break, simultaneous)
Cable Entry2 tapped entries for M20 x1.5
Electromagnetic LockingLocking on de-energization and unlocking on energization of solenoid
Solenoid Rated Supply Voltage [Us]24 V AC/DC (supply voltage limits: 20...52 V)
Cable Outer Diameter7...13 mm
Electrical ConnectionTerminal block, clamping capacity: 1 x 0.5 to 2 x 1.5 mm² with or without cable end-sleeve
Number of Poles3
Optional LockingsWith locking, solenoid locking
Local SignalingOpen/closed and locked status indication: 2 LEDs (yellow or orange)
Signaling Circuit Voltage24/48 V (voltage limits: 20...52 V)

Complementary

Positive OpeningWith "O" contact
Supply Voltage TypeAC/DC
Supply Frequency50/60 Hz
Load Factor1
Power Consumption in VA10 VA (energized), 10 VA (sealed)
Signaling Circuit TypeAC/DC
Signaling Circuit Consumption7 mA
Mechanical Endurance1,000,000 cycles
Minimum Approach Speed0.01 m/s
Maximum Approach Speed0.5 m/s
[le] Rated Operational Current0.55 A at 125 V, DC-13, Q300 (conforming to EN/IEC 60947-5-1)
0.27 A at 250 V, DC-13, Q300 (conforming to EN/IEC 60947-5-1)
3 A at 120 V, AC-15, B300 (conforming to EN/IEC 60947-5-1)
1.5 A at 240 V, AC-15, B300 (conforming to EN/IEC 60947-5-1)
[Ithe] Thermal Rated Unenclosed Current6 A
[Ui] Rated Insulation Voltage50 V (conforming to EN/IEC 60947-1 for signaling circuit)
[Uimp] Rated Impulse Withstand Voltage6 kV (conforming to EN/IEC 60947-5-1)

Environmental Characteristics

Protection TypeOvervoltage protection for signaling circuit
Protection Against Short Circuits10 A cartridge fuse type gG (gl)
Forced Actuation for Extractible Key2000 N
Minimum Extraction Resistance20 N
Maximum Control Speed10 cycles/min for maximum viability
Safety LevelUp to Category 4 with appropriate surveillance system and wiring (conforming to EN/ISO 13849-1)
Up to PL = e with appropriate surveillance system and wiring (conforming to EN/ISO 13849-1)
Up to SIL 3 with appropriate surveillance system and wiring (conforming to EN/IEC 61508)
Reliability DataB10d = 5,000,000 cycles for a 20-year service life limited by wear or contact
Body MaterialZamak
Head MaterialZamak
Depth44 mm
Height146 mm
Width98 mm
Product Weight1.14 kg

Environment

StandardsEN/IEC 60947-5-1
EN/IEC 60204-1
EN 1088/ISO 14119
CSA C22.2 No 14
UL 508
EN/ISO 12100
Product CertificationsCSA
UL
Protective TreatmentTC
Operating Temperature-25...+40 °C
Ambient Storage Temperature-40...+70 °C
Vibration Resistance5 gn (f=10...500 Hz) (conforming to CEI 60068-2-6)
Mechanical Shock Resistance10 gn for 11 ms (conforming to CEI 60068-2-27)
Protection Class Against Electric ShockClass I (conforming to EN/IEC 61140)
IP Protection RatingIP67 (conforming to EN/IEC 60529 and EN/IEC 60947-5-1)

Offer Sustainability

Environmental Offer StatusGreen Premium Product
REACH RegulationREACH Declaration
EU RoHS DirectivePro-active Compliance (Product outside the scope of EU RoHS legal)
Mercury FreeYes
RoHS Exemption InformationYes
Environmental ProfileEnvironmental Product Profile
Circularity ProfileEnd of Life Information

Contractual Warranty

Warranty18 months

PDF preview unavailable. Download the PDF instead.

XCSE7312 document ?ts=1671249928501

Related Documents

Preview Schneider Electric XCSA/B/C Safety Interlock Switches - Technical Datasheet
Detailed technical specifications, dimensions, installation guidelines, and safety information for Schneider Electric XCSA, XCSB, and XCSC series safety interlock switches.
Preview Schneider Electric XCSLE/XCSLF Safety Interlock Switches - Technical Specifications and Installation Guide
Detailed technical specifications, wiring diagrams, installation instructions, and safety precautions for Schneider Electric XCSLE and XCSLF safety interlock switches. Covers product certifications, electrical characteristics, environmental resistance, and operational guidelines.
Preview Schneider Electric Preventa XPSAFL Safety Modules Catalog
Catalog for Schneider Electric's Preventa XPSAFL safety modules, designed for emergency stop, switch, and safety light curtain monitoring. Details operating principles, product certifications, and references.
Preview SoMachine Functions and Libraries User Guide
User guide for SoMachine, detailing functions, library management, and function block implementation. Covers library referencing methods, library manager editor, creating custom libraries, and library overviews.
Preview Schneider Electric XPS-AC Safety Relay for Emergency Stop Monitoring
This document provides comprehensive technical information, safety guidelines, and operational details for the Schneider Electric XPS-AC safety relay. It covers features, specifications, wiring diagrams, functional diagrams, and compliance standards for monitoring emergency stop circuits.
Preview Schneider Electric ABL8BBU24200 Battery Control Module Datasheet
Technical specifications, characteristics, dimensions, mounting, wiring, and sustainability information for the Schneider Electric ABL8BBU24200 battery control module, a 24-28.8 V DC, 20 A module for regulated SMPS.
Preview Schneider Electric TeSys Ultra Reverser Block LU6MB0BL - 38A/690V, 24VDC Coil
Technical data sheet for Schneider Electric TeSys Ultra reverser block, model LU6MB0BL. Features include 38A/690V rating, 24VDC coil, separate mounting, motor control application, and compliance with various international standards.
Preview Schneider Electric TeSys DF Fuse Carrier DF143VC - Product Data Sheet
Detailed product data sheet for the Schneider Electric TeSys DF fuse carrier, model DF143VC. Includes specifications, dimensions, environmental data, and packaging information for this 3-pole, 50A, 690VAC fuse carrier with a 14x51mm fuse size and blown fuse indicator.