Installation Guide for WINK HAUS models including: BS TI BlueSmart Reader, BS TI, BlueSmart Reader, Reader
File Info : application/pdf, 6 Pages, 240.39KB
DocumentDocumentInstallation manual blueSmart Reader BS TI and BS TE (except BS TI/TE SR) For a contactless read-out of blueSmart keys, blueSmart cards and HSH keys. With the release of a relay contact, optionally closed-circuit operations or normal operations. Technical data and pin configuration: Supply voltage at V1 and V2: Switch outputs: Additional switch outputs for BS TE operation (Control unit): Protection class: Temperature range BS TE: Temperature range BS TI: Reading distance: Assembly: 7,5V to 25V DC or 10V to 18V AC 50 Hz Maximum power consumption at 12V DC 200 mA (Limited Power Source max. 8 A; max. 100VA) Relay connection NO = normal open, operating side Relay connection COM = common, middle pin On release of the relay COM is switched to NO. Switching current max: 1.5A @ 20 °C Switching voltage max: 30V DC, 20V AC 50 Hz Relay connection NC = normal closed, non-operating side. If the relay is disabled, COM is switched to NC. Reader unit: e.g. Siedle or Elcom IP54, Gira TX44 IP44 other designs IP20 acc. to DIN EN 60529 Control unit: IP20 acc. to DIN EN 60529 Reader unit: -25 °C to +70 °C Control unit: 0 °C to +50 °C Control unit: 0 °C to +50 °C with blueSmart key: typically 10 mm with blueSmart card: typically 40 mm preferably in standard flush mounted box (UP55) or surface-mounted box combined with a suitable switch design (e. g. Gira, Siedle, bticino) Important: Connection of a higher voltage will cause the destruction of the reader. It is recommended to use a regulated power supply which provides an output voltage of 12 V. The device is not suited for a voltage supply from IT networks. The following note only applies to the BS TE control unit: In a voltage-free condition of the reader no contact exists between "NC" and "COM"! Aug. Winkhaus GmbH & Co. KG · Hessenweg 9 · 48157 Münster · T +49251-4908-0 · F +49251-4908-145 www.winkhaus.de Cabling: Max. cable length between reader and control unit: 100 m. Max. cable length between control unit and intrusion detection system: 30 m. The reader and control units communicate via an RS 485 interface. The RS 485 data lines of the reader unit and the inputs of the control unit must be equipped with a shielded cable. As regards cable lengths of more than 3 m, the bus should be terminated with a resistance between A and B near the endpoints of the line. Suitable values are between 470 and 220 ohm (>= 1/8 W). The shield must be connected to ground potential at one point. If the control unit is installed in a distribution / flush-mounted box, the voltage should be smaller than 40V. The reader can be configured for various operating modes: Standard: Only relay 1 is released on presentation of an authorised identification medium. Presence authorisation: On short presentation (standard: shorter 3 seconds) of an authorised identification medium relay 1 is released. If an authorised identification medium is presented for a time longer than 3 seconds, relay 2 is also released. Additional authorisation: It is possible for an identification medium to possess the basic authorisation and the additional authorisation. On presentation of an identification medium having a basic authorisation relay 1 is released. On presentation of an identification medium that possesses also the additional authorisation, both relays are released. Authorisation of intrusion detection systems: It is also possible to control (arming and disarming) intrusion detection systems by means of a relay. This requires a long presentation of an identification medium with a system authorisation. Installation instructions: - Mounting, programming and disassembly may only be performed by specialised staff according to IEC 62368-1. - It is recommended to provide a turn-off device for the power supply. - If several readers are being installed, a minimum distance of at least 20 cm must be maintained between the readers. - If inductive loads are switched, the attached extinguishing diode (free- wheeling diode) must be installed parallel to the load for protecting the contacts. Aug. Winkhaus GmbH & Co. KG · Hessenweg 9 · 48157 Münster · T +49251-4908-0 · F +49251-4908-145 www.winkhaus.de Wiring of the blueSmart BS TI reader: V1 12 V AC/DC V2 Terminal block: Reader unit BS TI LED ribbon cable only for Siedle readers Ribbon cable reader Optional Relay 2 Optional Touch Terminal (RS 485) Wiring of the blueSmart BS TE reader: V1 12 V AC/DC V2 Terminal block: Reader unit BS TE LED ribbon cable only for Siedle readers Ribbon cable reader 15 14 13 12 11 10 1 23 4 5 6 RS485 B Touch Terminal (optional) RS485 A Touch Terminal (optional) recovery diode door opener 1 bipolar 12 V AC recovery diode door opener 2 bipolar 12 V AC RS485 B Touch Terminal (optional) RS485 A Touch Terminal (optional) 15 14 13 12 11 10 1 23 4 5 6 PIN assignment control unit, see following page V1 V2 RS 485 A RS 485 B Optional Touch Terminal (RS 485) blueSmart Reader BS TI Terminal block: PIN assignment 1 Supply voltage VIN 1 2 Supply voltage VIN 2 3 RS 485 A (M) 4 RS 485 B (M) 5 RS 485 A (IO) 6 RS 485 B (IO) 10 COM Relay 2 11 not occupied 12 NO Relay 2 13 COM Relay 1 14 not occupied 15 NO Relay 1 blueSmart Reader BS TE Supply voltage VIN 1 Supply voltage VIN 2 RS 485 A (M) RS 485 B (M) RS 485 A (IO) RS 485 B (IO) - Aug. Winkhaus GmbH & Co. KG · Hessenweg 9 · 48157 Münster · T +49251-4908-0 · F +49251-4908-145 www.winkhaus.de Pin assignment on control unit (only for BS TE): Terminal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Configuration Relay 1 NO Relay 1 NC Relay 1 COM Relay 2 NO Relay 2 NC Relay 2 COM V1 V2 Ground RS 485 A RS 485 B RS 485 COM Input 1 Input 2 Input 3 Input 4 Input COM NO COM NC NO COM NC 1 2 3 4 5 6 Relay 1 Relay 2 LED Supply voltage 7 8 No internal connection 9 RS485 A 10 RS485 B 11 RS 485 COM 12 17 16 15 14 13 blueSmart reader BS TI/TE: LED and buzzer signals Display of system status Normal state, continuous release inactive Green LED Normal state, continuous release active Behaviour of the blueSmart reader, in the event of a normal state entry Red LED Yellow LED Buzzer Authorised key Release time 200 ms Unauthorised key Authorised key (continuous release active) Timeout Unauthorised key (continuous release active) Activation of continuous release Deactivation of continuous release (Red LED blinks along with a buzzer signal, after that yellow LED blinks) Display of an error condition This condition leads to the deactivation of the continuous release Error clock time, continuous release inactive Error time, continuous release active Behaviour of the blueSmart reader, in the event of a transaction during an error state Error No transaction is possible in this state Error time Alternating with the signalling of a normal transaction Behaviour on the blueSmart reader during a programming procedure 3 ms yellow LED signal after each received data frame 750 ms 12 ms 12 ms 2 x 200 ms 2 x 750 ms 10 x 50 ms 750 ms LED on LED blinks Aug. Winkhaus GmbH & Co. KG · Hessenweg 9 · 48157 Münster · T +49251-4908-0 · F +49251-4908-145 www.winkhaus.de Operating information for controlling an intrusion detection system: Inputs of control unit: The BS TE control unit has four inputs. These inputs analyse the status of the connected intrusion detection system. A logical zero (low signal) is detected in case the voltage is smaller than 3V. A logical one (high signal) is detected in case the voltage is higher than 3V. The input voltage must not exceed 24V. In this case the signal current is 4mA. The COM input must be connected to ground. The control unit inputs are configurated as follows: Input 1 status of intrusion detection system: A logical one (high signal) is interpreted as "armed system". A logical zero (low signal) is interpreted as "disarmed system". Input 2 alarm: A logical one (high signal) is interpreted as "system gives no alarm". A logical zero (low signal) is interpreted as "system gives alarm". Input 3 readiness to be armed: A logical one (high signal) is interpreted as "system not ready to be armed". In this state activation of the intrusion detection system is not possible, not even with an authorised identification medium! A logicial zero (low signal) is interpreted as "system ready to be armed". Only then the intrusion detection system is ready to be activated with an authorised identification medium. Input 4 is without function in this configuration. In the mode "system authorisation" the BS TE reader is configurated with a pulse period of 500 ms in the pulse mode. This means a long presentation (more than 3 seconds) of an authorised identification medium will give a switch-over pulse to relay 1 of the system. Relay 2 switches from the normal state (NC) to the NO state for 500 ms and after that returns to the normal state (NC). A short presentation (less than 3 seconds) of an authorised identification medium will cause relay 1 to be released for a parameterisable time (standard: 2 seconds). Before the relay is released the status of the intrusion detection system (input 1) is retrieved. Release of the relay requires the state "disarmed". Signalling of intrusion detection system: System is armed 4 seconds: LED 2 red, buzzer on System is disarmed 4 seconds: LED 2 green, buzzer on Alarm signalling in idle state If the intrusion detection system indicates triggering of an alarm, this is signalled by the reader unit as follows: 400 ms: LED 1 red, LED 2 red, buzzer off 400 ms: LED 1 off, LED 2 off, buzzer off Alarm signalling in case of a locking event If the intrusion detection system indicates an alarm during a locking event, this is signalled to the user acoustically and visually. The following signalling is repeated for 2 seconds: 200 ms: LED 1 red, LED 2 red, buzzer on 50 ms: LED 1 off, LED 2 off, buzzer off Aug. Winkhaus GmbH & Co. KG · Hessenweg 9 · 48157 Münster · T +49251-4908-0 · F +49251-4908-145 www.winkhaus.de Signalling of errors: No access due to armed intrusion detection system During each aufhorised locking event, the state of the system is controlled. If the system is armed, opening is not possible. LED 1 is switched to "permanent red". The following signalling is repeated 3 times 100 ms: LED 2 red, buzzer on 10 ms: LED 2 off, buzzer off Intrusion detection system not ready to be armed / no switch-over The following signalling is repeated for 8 seconds: 200 ms: LED 2 red, buzzer on 50 ms: LED 2 off, buzzer off Error during access to control unit The control unit cannot be reached for authorisation check. The following signalling is repeated 10 times: 100 ms: LED 2 red, buzzer on 10 ms: LED 2 off, buzzer off Invalid time LED 1 blinks red ZO MW 082021 Print-no. 997 000 162 ENG | All rights, including the right of alteration, are reserved. Environmental damage caused by electronic components that are improperly disposed of! - It is forbidden to dispose of the product with house- hold waste, the disposal must be performed according to the regulations. Therefore, dispose of the product in accordance with European Directive 2012/19/ EU at a municipal collection point for electrical waste or have it disposed of by a specialist company. - The product can alternatively be returned to Aug. Winkhaus GmbH & Co. KG, Entsorgung/Verschrottung, Hessenweg 9, 48157 Münster, Germany. Aug. Winkhaus GmbH & Co. KG herewith declares that the device is compliant with the basic requirements and the relevant rules of the directive 2014/53/EU. The complete version of the EU declaration of conformity is available at: www.winkhaus.com/konformitaetserklaerungen Aug. Winkhaus GmbH & Co. KG · Hessenweg 9 · 48157 Münster · T +49251-4908-0 · F +49251-4908-145 www.winkhaus.de