Viessmann Vitodens 100-W/111-W Commissioning Quickstart Guide

This guide highlights the new and unique process for commissioning. For installation, please refer to the detailed steps in the Installation & Service Instructions.

User interface

Indicators:
  • Heating circuit 1 and 2
  • DHW temperature
  • System pressure
  • DHW ECO function
  • Reduced temperature level
  • Wifi connection
  • Service menu
  • Fault display
  • Burner status

The indicator display shows numerical values, e.g., 8:88.

Navigation:
  • OK: Confirm settings
  • Menu: Opens the main menu
  • Up & down: Change parameter

Navigation buttons are labeled OK, Menu, Up, and Down.

Getting started

Follow the step-by-step guide to commission the product using the control panel. Default parameters are highlighted for each step. The ViGuide mobile application can also be used for commissioning. To connect the boiler to the internet for ViGuide monitoring, or to connect a Viessmann ViCare Thermostat or Vitotrol 100-E, use ViGuide. Refer to the last page for more information.

Commissioning steps:

Access Point AP

Indicates the boiler is ready to be set up. Press the Menu button for 4 seconds to start commissioning from the panel.

C.1 Filling programme

ON > moves diverter valve to mid position for ease of filling via filling loop.

OFF - default > skips filling programme. Press OK to confirm the setting.

Press the Menu button for 4 seconds to interrupt the filling programme.

C.2 Venting programme

ON > pump runs in intervals and diverter moved to mid position; this can take up to 20 mins.

OFF – default > skips venting programme. Press OK to confirm the setting.

Press the Menu button for 4 seconds to interrupt the venting programme.

C.3 Gas Type

2 - default > natural gas, 3 > liquid gas. Press OK to confirm the setting.

C.5 Flue System Type

1 > room air dependent (60 mm), 2 - default > room sealed (60 mm/100 mm),

3 > room air dependent (80 mm), 4 > room sealed (80 mm/125 mm).

Press OK to confirm the setting.

C.6 Flue System Length

Press the Down arrow button to adjust the length in metres. The default setting is 1 m (an additional length of 1 m must be factored in for every flue bend). Press OK to confirm the setting.

C.7 Operating Mode

1 > built in time program, 4 > weather comp.,

13 - default > constant operation (switch live) with optional room thermostat,

14 > OpenTherm. Press OK to confirm the setting.

C.8 Hydraulic/System Scheme

1 > combi or system boiler on S/Y plan, 3 - default > system boiler with 4 pipe cylinder sensor or demand box. Additional options for mixed circuits and low loss header are available. Please refer to the commissioning section in the manual. Press OK to confirm the setting.

C.9 Activating Switch Live with Weather Compensation (only available if C.7 = 4)

To activate, plug 96 switch live with weather compensation, select 1.

For additional options, please refer to the commissioning section in the installation manual. Press OK to confirm the setting.

C.10 EM-EA1 settings

0 - default > no function. For additional options, please refer to the manual (refer to the commissioning section in the installation manual). Press OK to confirm the setting.

C.11 Date

Press the Up/Down arrow buttons to adjust the date (day, month, year). Press OK to confirm each setting.

C.12 Time

Press the Up/Down arrow buttons to adjust the time (hours, minutes). Press OK to confirm each setting.

C.13 Summer/ Winter Time changeover

ON > time will be changed automatically. OFF - default > constant time.

Press OK to confirm the setting.

C.14 Plug 96 additional options

For additional options, please refer to the commissioning section in the installation manual. Note: This step does not need to be adjusted for switch live activation.

C.15 Vitotrol 200-E

Only when C.7 is set to 4 (weather comp.), select ON to activate Vitotrol 200-E. Press OK to confirm the setting.

End

After completing the last step, an arrow will appear indicating commissioning is complete. Press OK to confirm the setting and start the flue gas sensor check. The boiler will restart.

FST will appear (the boiler is carrying out flue gas sensor check & will fire for a few seconds to raise sensor temperature). Please wait for this to complete. Once completed, the boiler set temperature will appear on the screen, and the boiler is ready to run.

Viessmann Controls & ViGuide Monitoring

ViGuide

  • Full text explanation assisting in commissioning the product.
  • Connect appliances to the internet and monitor the product remotely.
  • Add Viessmann thermostat solutions like the Vitotrol 100-E.
  • Guided spare part replacement supporting with step-by-step instructions.

The application can be downloaded from the Google Play Store or Apple App Store. Scan the QR code for further information.

[QR code for ViGuide download]

[QR code for ViGuide download]

Viessmann Account

The Viessmann Account is a single sign-on for all Viessmann applications. Once set up, access all tools including ViGuide & PartnerPortal. To sign up, scan the QR code or visit www.viessmann.co.uk/account. The link directs to the application form. After processing, an email will be sent for account verification.

[QR code for Viessmann Account sign-up]

[Viessmann logo]

[QR code for Viessmann Account sign-up]

PartnerPortal

  • Stay informed with the latest news & access video content.
  • Register installations with Gas Safe.
  • Benefit from the VPlus loyalty scheme & collect points with every installation.
  • Book courses with the academy team or use the video tutorial library.
  • Discover all software applications, tools & services.

Once your Viessmann Account is set up, access the Partner Portal via the QR code.

[QR code for Partner Portal access]

Further Information & Support

For more information, visit the support page for detailed explanations, FAQs & video tutorials. Scan the QR code or visit viessmann.co.uk/vitodensgetstarted to access the page.

[QR code for support page]

Models: VITODENS 100-W 111-W Wall Mounted Gas Condensing Boilers, VITODENS 100-W 111-W, Wall Mounted Gas Condensing Boilers, Gas Condensing Boilers, Condensing Boilers, Boilers

File Info : application/pdf, 4 Pages, 840.12KB

PDF preview unavailable. Download the PDF instead.

Quickstart Guide Vitodens 100-W

References

Adobe PDF Library 15.0 Adobe InDesign 16.1 (Windows)

Related Documents

Preview Viessmann Vitodens 100-W/111-W Commissioning Quickstart Guide
A quickstart guide for commissioning Viessmann Vitodens 100-W and 111-W boilers, detailing user interface, setup steps, and essential settings for optimal operation.
Preview Viessmann Vitodens Gas Boiler Guide: Efficient Heating Solutions
Explore the Viessmann Vitodens range of high-efficiency gas condensing boilers, including models 050-W, 100-W, 111-W, 200-W, 222-F, and 242-F. Learn about their features, benefits, technical specifications, installation accessories, and control systems for optimal home comfort and energy savings.
Preview Viessmann Vitodens 100-W & 111-W Gas Condensing Boilers: Efficient Home Heating
Discover the Viessmann Vitodens 100-W and 111-W wall-mounted gas condensing boilers. Featuring advanced MatriX Plus burner technology, Inox-Radial heat exchangers, and smart connectivity via the ViCare app for efficient, reliable, and cost-effective home heating.
Preview Viessmann Burner Assembly Installation Instructions
Detailed installation instructions for Viessmann burner assembly, including safety requirements, removal, replacement, and reinstallation procedures for components like the electrode block, burner refractory, and burner tube. For use with Vitodens 100-W, WB1B, B1HA, and B1KA boilers.
Preview Viessmann Vitodens 111-W Installation and Service Instructions for Contractors
Comprehensive guide for contractors on installing, servicing, and maintaining the Viessmann Vitodens 111-W gas condensing storage combi boiler. Covers safety, setup, operation, and troubleshooting.
Preview Viessmann Vitodens 100-W System Boiler Wiring Instructions
Detailed wiring instructions for the Viessmann Vitodens 100-W system boiler, covering various installation options including 4-pipe systems with unvented and vented cylinders, and traditional Y or S-plan systems. Includes electrical wiring examples and component descriptions.
Preview Viessmann Burner Gaskets Installation Instructions
Installation instructions for Viessmann burner gaskets, including safety requirements, installation procedures, and torque specifications for various gasket models used with Viessmann boilers.
Preview Vitodens 100-W Operating Instructions
Comprehensive operating instructions for the Viessmann Vitodens 100-W wall-mounted, gas-fired condensing boiler, covering installation, operation, troubleshooting, and maintenance.