User Manual for Fresca models including: ORA-01 Fresca Fan, ORA-01, Fresca Fan, Fan
Fresca Fan White - OneX Products
Installation - Connecting the power cables 3. Electrical wiring a. Locate the two DC power terminals at the bottom of the fan unit marked ( ) Positive and (-) Negative. Positive
ORA-01 The fan for your RV RV 1 Items supplied in package Unpacking the product Carefully unpack the box and confirm that the following items are included: 1 2 3 4 1. 01 x Main Fresca Fan unit 2. 01 x Back mounting plate 6 3. 02 x Screws Mounting parts 4. 02 x 3.2 mm stainless steel nuts 7 5 5. 01 x DC Power cable pair 6. 02 x Locking washer 7. 02 x 2.2 mm brass nuts Wiring parts 8. 01 x Double sided tape 8 Equipment required for installation (Not included in package) · Adjustable wrench (to assemble cables to bottom of unit) · Phillips head screw driver · 06 x 6 mm diameter mounting screws 2 Installation - Preparing back mounting plate 1. Preparing of back mounting plate a. Identify the intended mounting location for the fan. b. Insert the 2 stainless steel (Item 4) nuts into the nut recess holes on both sides of the back mounting plate. c. Peel backing off from double sided tape (Item 8) supplied, and stick it onto the back of the back mounting plate. Peel backing off from double sided tape This is how the back of the plate will look like with the two nuts and double sided tape applied. 3 Installation - Mounting of back mounting plate 2. Mounting of back mounting plate a. Place the back mounting plate with the double sided tape facing towards the mounting location and stick the back mounting plate in place. Use 6 mm screws (not supplied) suitable for use in mounting of fan 1 2 3 5 4 6 b. Secure the back plate permanently at the intended location with 06 x 6 mm screws (not supplied) that is suitable for the wall at the mounting position. 4 Installation - Connecting the power cables 3. Electrical wiring a. Locate the two DC power terminals at the bottom of the fan unit marked (+) Positive and (-) Negative. Take Note: Marking to be used in fan orientation during mounting - Negative + Positive (Red dot marking) b. Connect the supplied DC power cable pair (Item 5), onto the two terminals - with the DC power cable pair (Item 5), locking washers (Item 6) and brass nuts (Item 7) in the correct order as shown. -Negative Cable (Black) · 2.2 mm brass nuts · Locking washer · DC Power cable + Positive Cable (Red) c. Tighten all brass nuts on the two (+) Positive & (-) Negative terminals with a pliers or wrench. Do not tighten by hand ONLY. 5 Installation - Routing the cable and mounting d. There are three options to routing of the DC power cables, depending on how you are wiring the power cables. Option 2: Via top groove notch Option 3: Via hole on the back mounting plate (May need to cut a hole for wires to pass through the double sided mounting tape if this position is chosen for cable routing. + Positive Terminal (Red dot marking) Take Note: Marking to be used in fan orientation during mounting Option 1: Via bottom groove notch e. Once the wiring has been done, mount the fan unit onto the back mounting plate by sliding it onto the corresponding 6 key-slots & secure the fan with the two screws provided (Item 3). Correct orientation Take Note: Ensure the "L" marking is on the bottom when mounting the fan. 6 Operation - Using the fan Keep the fan blades clear of any obstructions during operation. The fan MUST be locked in position before turning on. 3. Fan directional angle adjustment Locking Lever Adjust the fan and lock in place by locking the Locking Lever Timer indicator LEDs Timer Button Power Indicator LED (blue) When fan is ON, these two LED will be ON Power & Speed Button a) Timer Press to cycle through Timer b) Power & Speed Press to cycle through Speed Timer LED indicators Timer LED Off Timer button · 3 hrs Fan is Off Speed button · Low Timer button · 6 hrs Speed button · Medium Timer button · 9 hrs Timer button · 12 hrs Timer button · Timer LED Off Speed button · High Speed button · Power Off Turning fan OFF at mid-timer 7 Safety · The Fresca fan unit includes an over-current protection that protects the motor from short circuit. · The Fresca fan unit includes a reverse polarity protection that protects the fan against any accidental reverse polarity. 8 Care & Maintenance · The Fresca fan unit is designed for low maintenance. · Turn off power to unit before any cleaning operations. · The fan can be cleaned by wiping off accumulated dust or dirt with a dry cloth. · Do not use cleaning solvent on any of the fan's parts and surfaces. 9 User Warnings & Reminders · Do not obstruct moving fan blades during operation. · Do not use the fan outdoors (this fan is ONLY for indoor use). · Do not use on wet surfaces or immerse in water. · Do not place any objects close to the fan that may be sucked in or drawn onto the blades. · Do not use near open fires, fireplace, stoves or any high heat source. · Children must be supervised to ensure that they do not play with the fan. · Do not use fan when any of the power cables to the fan is frayed or damaged. 10 Specification Fan Speed LOW MEDIUM HIGH Current Draw in Amperes (A) 12 Volts 24 Volts 0.12 0.06 0.22 0.11 0.35 0.21 RPM 12 Volts & 24 Volts 1100 + 100 1400 + 100 1700 + 100 Maximum Airflow: · 140 CFM (Cubic Feet Per Minute) · 238 m3/h (Cubic Feet Per Hour) Version (F)Adobe PDF Library 17.0 Adobe InDesign 18.2 (Macintosh)