Midea Remote Controller Manual
Thank you for purchasing a Midea air conditioner. Please read this manual carefully before operating your new unit. Save this manual for future reference.
Remote Controller Specifications
Model | RG10F(B)/BGEF, RG10F1(B)/BGEF, RG10F2(B1)/BGEFU1, RG10F3(B1)/BGEFU1 |
Rated Voltage | 3.0V (Dry batteries R03/LR03x2) |
Signal Receiving Range | 8m |
Environment | -5°C ~ 60°C (23°F ~ 140°F) |
Quick Start Guide
- FIT BATTERIES: Slide the back cover down, insert batteries matching (+) and (-) ends, slide cover back.
- SELECT MODE: Press MODE button to cycle through AUTO, COOL, DRY, HEAT, FAN.
- SELECT TEMPERATURE: Use TEMP ▲ or TEMP ∨ buttons to adjust temperature.
- SELECT FAN SPEED: Use FAN SPEED button to select AUTO, LOW, MED, or HIGH.
- POINT REMOTE TOWARD UNIT: Ensure the remote is directed at the air conditioner.
- PRESS POWER BUTTON: Press ON/OFF to turn the unit on or off.
Special Note: Button designs may vary. If a function is not available on the unit, pressing the corresponding button on the remote will have no effect. In case of discrepancies between the "Remote Controller Manual" and the "USER'S MANUAL", the "USER'S MANUAL" description prevails.
Handling the Remote Controller
Inserting and Replacing Batteries
Your air conditioning unit may come with two batteries. Insert batteries before use:
- Slide the back cover downward to expose the battery compartment.
- Insert batteries, matching the (+) and (-) ends with the symbols inside the compartment.
- Slide the battery cover back into place.
Battery Notes
- For optimal performance, do not mix old and new batteries, or batteries of different types.
- Remove batteries if the remote control will not be used for more than 2 months.
Battery Disposal
Do not dispose of batteries as unsorted municipal waste. Refer to local laws for proper disposal.
Tips for Using Remote Control
- The remote control must be used within 8 meters of the unit.
- The unit will beep when a remote signal is received.
- Curtains, other materials, and direct sunlight can interfere with the infrared signal receiver.
- Remove batteries if the remote will not be used for more than 2 months.
Notes for Using Remote Control (Compliance)
The device complies with local national regulations. In Canada, it complies with CAN ICES-3(B)/NMB-3(B). In the USA, it complies with Part 15 of the FCC Rules, subject to two conditions: (1) it may not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with Class B digital device limits per FCC Rules, designed to provide reasonable protection against harmful interference in residential installations. If interference occurs, users are encouraged to try correcting it by reorienting/relocating the receiving antenna, increasing separation between equipment and receiver, connecting to a different circuit, or consulting a dealer/technician. Unauthorized modifications may void the user's authority to operate the equipment.
Buttons and Functions
Familiarize yourself with the remote control. Refer to "How to Use Basic Functions" for operating instructions.
ON/OFF: Turns the unit on or off.
TEMP ▲: Increases temperature in 1°C increments. Max. temperature is 30°C.
SET: Scrolls through operation functions (Fresh, I Sense, AP mode). The selected symbol flashes; press OK to confirm.
TEMP ∨: Decreases temperature in 1°C increments. Min. temperature is 17°C.
FAN SPEED: Selects fan speeds: AUTO → LOW → MED → HIGH.
TIMER ON: Sets timer to turn the unit on.
MODE: Scrolls through operation modes: AUTO → COOL → DRY → HEAT → FAN. (Note: HEAT mode may not be supported by cooling-only units).
SHORTCUT: Restores current or previous settings.
OK: Confirms selected functions.
SWING: Starts/stops horizontal louver movement. Hold for 2 seconds for vertical louver auto swing.
TIMER OFF: Sets timer to turn the unit off.
I SENSE: Activates I SENSE mode.
SLEEP: Saves energy during sleeping hours.
LED: Turns the indoor unit's LED display and buzzer on/off for a comfortable environment.
Models: RG10F(B)/BGEF, RG10F1(B)/BGEF (Fresh feature not available)
Remote Screen Indicators
Information displayed when the remote controller is powered up:
- Transmission Indicator: Lights up when sending a signal.
- TIMER ON/OFF display: Indicates timer status.
- Silence feature display: Indicates silence mode.
- FAN SPEED display: Shows selected fan speed (LOW, MED, HIGH, AUTO). Note: Fan speed cannot be adjusted in AUTO or DRY mode.
- Fresh feature display: (Some units) Shows when Fresh feature is active.
- Sleep mode display: Shows when Sleep mode is active.
- Follow me feature display: Shows when Follow me feature is active.
- Wireless control feature display: Shows wireless control status.
- Low battery detection display: Flashes when battery is low.
- MODE display: Shows current mode (AUTO, COOL, DRY, HEAT, FAN).
- ECO display: Not available for this unit.
- GEAR display: Not available for this unit.
- LOCK display: Shows when the LOCK feature is activated.
- Temperature/Timer/Fan speed display: Shows set temperature, fan speed, or timer setting. Temperature range: 17°C-30°C (62°F-86°F). Timer setting range: 0-24 hours. Display is blank in FAN mode.
Note: Indicators shown are for presentation; actual operation displays relative function signs.
How to Use Basic Functions
Basic Operation
ATTENTION! Ensure the unit is plugged in and power is available before operation.
Setting Temperature
Operating temperature range: 17°C-30°C (62°F-86°F). Increase or decrease temperature in 1°C (1°F) increments.
AUTO Mode
- Press MODE to select AUTO.
- Set desired temperature using TEMP ▲ or TEMP ∨.
- Press ON/OFF to start the unit.
In AUTO mode, the unit selects COOL, FAN, or HEAT based on set temperature. Fan speed cannot be set in AUTO mode.
COOL Mode
- Press MODE to select COOL.
- Set desired temperature using TEMP ▲ or TEMP ∨.
- Press FAN button to select fan speed: AUTO, LOW, MED, or HIGH.
- Press ON/OFF to start the unit.
DRY Mode (dehumidifying)
- Press MODE to select DRY.
- Set desired temperature using TEMP ▲ or TEMP ∨.
- Press ON/OFF to start the unit.
Note: FAN SPEED cannot be changed in DRY mode.
FAN Mode
- Press MODE to select FAN mode.
- Press FAN button to select fan speed: AUTO, LOW, MED, or HIGH.
- Press ON/OFF to start the unit.
Note: Temperature cannot be set in FAN mode. The remote control's LCD screen will not display temperature.
HEAT Mode
- Press MODE to select HEAT.
- Set desired temperature using TEMP ▲ or TEMP ∨.
- Press FAN button to select fan speed: AUTO, LOW, MED, or HIGH.
- Press ON/OFF to start the unit.
Note: As outdoor temperature drops, HEAT function performance may be affected. Consider using other heating appliances in conjunction.
Setting the TIMER
TIMER ON/OFF
Set the time after which the unit will automatically turn on/off.
TIMER ON setting:
Press TIMER ON button. Use UP/DOWN buttons to set desired ON time. Point remote to unit and wait 1 second for activation.
TIMER OFF setting:
Press TIMER OFF button. Use TEMP UP/DOWN buttons to set desired OFF time. Point remote to unit and wait 1 second for activation.
Note: Time increases in 30-minute increments up to 10 hours, then in 1-hour increments up to 24 hours. Timer reverts to 0.0 after 24 hours. Cancel by setting timer to 0.0h.
TIMER ON & OFF setting (example)
Example: If current time is 1:00 PM, setting ON timer for 2.5 hours and OFF timer for 5 hours means the unit will turn on at 3:30 PM and turn off at 6:00 PM.
How to Use Advanced Functions
SHORTCUT function
Press SHORTCUT button: Restores previous settings (operating mode, temperature, fan speed, sleep feature). Pressing for more than 2 seconds restores current operation settings.
Swing function
Press Swing button: Horizontal louvers swing up/down. Press again to stop. Keep pressing for more than 2 seconds for vertical louver auto swing (model dependent).
°C/°F (some models)
Press this button to alternate temperature display between °C and °F.
LED DISPLAY
Press LED button: Turns the indoor unit's display and buzzer on/off.
SLEEP Function
Press SLEEP button: Decreases energy usage during sleep. This function can only be activated via remote control. Not available in FAN or DRY mode.
I SENSE (some models)
Press I SENSE button: Remote display shows actual temperature at its location. Signal sent to air conditioner every 3 minutes until I SENSE button is pressed again.
LOCK function
Press and hold LED and I SENSE (or LED and °C/°F) buttons simultaneously for more than 5 seconds to activate Lock function. All buttons become unresponsive except for the combination used to activate it, which can be used to disable locking.
SET function
Press SET button to enter function setting. Use SET, TEMP ∨, or TEMP ▲ to select desired function. Selected symbol flashes; press OK to confirm. To cancel, repeat the procedure. Functions include Fresh (lonizer/Plasma Dust Collector for impurity removal), and AP mode (wireless network configuration). For AP mode, some units require pressing the LED button seven times in 10 seconds.
File Info : application/pdf, 16 Pages, 607.08KB
DocumentDocumentRelated Documents
![]() |
Midea Air Conditioner Remote Controller Illustration This document provides a detailed illustration and explanation of the Midea air conditioner remote controller, covering function buttons, LCD screen indicators, and basic and advanced operating functions. |
![]() |
Midea RM12F1 Remote Controller: Operation and Installation Manual Comprehensive guide for installing and operating the Midea RM12F1 remote controller for air conditioners. Includes setup, functions, and field settings. |
![]() |
Midea Air Conditioner Remote Controller Owner's Manual Comprehensive owner's manual for Midea air conditioner remote controllers (models RG51A(2)/E, RG51B(2)/E), detailing specifications, button functions, operation modes, screen indicators, and advanced features like timers and energy-saving modes. Includes instructions for basic and advanced operations, troubleshooting tips, and FCC compliance information. |
![]() |
Midea KJR-29B/BK-E Wired Controller Manual User manual for the Midea KJR-29B/BK-E touch-style key wired controller, detailing its specifications, functions, installation, and initial parameter settings for Midea air conditioning systems. |
![]() |
Midea WDC-120G/WK(A) Wired Remote Controller Installation Manual This manual provides detailed instructions for the installation and operation of the Midea WDC-120G/WK(A) wired remote controller. It covers safety precautions, main parameters and functions, controller outlook, operation instructions, and technical requirements. |
![]() |
Midea Remote Controller Owner's Manual - Operation Guide Learn how to operate your Midea air conditioner with this comprehensive owner's manual for the Midea remote controller. Covers all functions, modes, and settings for optimal comfort and efficient use. |
![]() |
Midea Mobile Air Conditioner Owner's Manual & Installation Guide - CP002UI-PT User and installation manual for Midea mobile air conditioners, model CP002UI-PT. Covers safety, setup, operation, maintenance, and troubleshooting. |
![]() |
Midea Portable Air Conditioner User Manual: Installation, Operation, and Safety Comprehensive user manual for Midea portable air conditioners (MAP08S1XWT, MAP10S1XWT, MAP10HS1XWT) detailing installation, operation, safety precautions, troubleshooting, and warranty. Learn how to set up and use your Midea AC efficiently. |