Mitsubishi Electric AE1600-SW Air Circuit Breaker

Material Fact Sheet - Document ID: 703298

Model: AE1600-SW 3P F TAL ETRBASE-P3 AX10 1600A

General Data

Product HierarchyIAN20107
Ext. Material GroupACB
ABC IndicatorAE-SW Body
e-shophttps://mitsubishi-electric-eshop.mee.com/mee/FA_IA/EUR/en/p/000000000000588205
CategoryFA-ACB: Air Circuit Breaker
SeriesAE-SW SERIES
TypeFIXED TYPE
Frame Size1600
Rated Voltage (V)690
Number of Poles3
Rated Current (A)1600
Current TypeAC
Current Range Ir (A)800-1600
Breaking Capacity at 500V (kA)65
Compliant with Standard(s)EN60947-2
Compliant with Standard(s) (2)IEC60947-2
Compliant with Standard(s) (3)JIS C 8201-2-1
Cycles with Rated Current5000
Cycles without Rated Current25000
No of Auxiliary Contacts NO5
No of Auxiliary Contacts NC5
Internal Power Supply (V)100-240 AC / 100-125 DC
Power consumption (W)41
Automatic Tripping DeviceELECTRONIC

Logistic Dimensions & Gross Weight

Length (cm)53.0
Width (cm)60.0
Height (cm)58.0
Gross Weight (kg)45.000
Volume (cdm)184.440

Stock Data

Planned Delivery Time (Days)92

Life Cycle

Sales Start01.12.2023
PredecessorNo Predecessor

Additional Product Information

Battery includedNO

Export Data

Commodity Code85365080
Legal Control (Dual Use List)Not Listed
Country of OriginJapan (JP)
Preference Status (Supplier Declaration)Non EU

Environmental

Dangerous Goods ClassNO
Dangerous Goods IdentifierNO

Conformity

RoHS ComplianceCOMPLIANT
WEEEB2B
CECOMPLIANT
UL/cULNON-COMPLIANT
EACNON-COMPLIANT
Shipping ApprovalsABS, BV, CCS, DNV-GL, LR, NK
UKCACOMPLIANT

Compatible Products

MaterialDescription / Price List Text / Classification
168510SST-LOCK-W - Shutter lock (for padlock) - Class 100100703: FA-ACB: Mechanical Option
168512CL-4-W - Cell switch 2C1T1D - Class 100100704: FA-ACB: Electrical Option
168513DF-W - Door frame - Class 100100703: FA-ACB: Mechanical Option
168514MD-AD125-W - Motor charging device; AC/DC 100 - 125V - Class 100100704: FA-ACB: Electrical Option
168515MD-AD250-W - Motor charging device; AC/DC 200 - 250V - Class 100100704: FA-ACB: Electrical Option
168518MD-D024-W - Motor charging device; DC 24V - Class 100100704: FA-ACB: Electrical Option
168519MD-D048-W - Motor charging device; DC 48V - Class 100100704: FA-ACB: Electrical Option
168520CC-AD250-W - Closing coil; AC/DC 100 - 250V - Class 100100704: FA-ACB: Electrical Option
168521CC-D048-W - Closing coil; DC 24 - 48V - Class 100100704: FA-ACB: Electrical Option
168522SHT-AD250-W - Shunt release; AC/DC 100 - 250V - Class 100100704: FA-ACB: Electrical Option
168523SHT-A500-W - Shunt release; AC/DC 380 - 500V - Class 100100704: FA-ACB: Electrical Option
168524SHT-D048-W - Shunt release; DC 24 - 48V - Class 100100704: FA-ACB: Electrical Option
168526UCONLABEL-W - Label for Under voltage trip controller - Class 100100704: FA-ACB: Electrical Option
168535TCA-AL-W - Trip coil (Auto reset type) with OCR alarm - Class 100100704: FA-ACB: Electrical Option
168536TCM-AL-W - Trip coil (Manual reset type) with OCR alarm - Class 100100704: FA-ACB: Electrical Option
168537BCL-W - Push button cover - Class 100100703: FA-ACB: Mechanical Option
168538CNT-W - Counter - Class 100100704: FA-ACB: Electrical Option
168539CYL-WK-W - Cylinder lock with key No. (#R0220) - Standard - Class 100100703: FA-ACB: Mechanical Option
168540CYL-WK1-W - Cylinder lock with key No. (#R501) - Class 100100703: FA-ACB: Mechanical Option
168541CYL-WK2-W - Cylinder lock with key No. (#R502) - Class 100100703: FA-ACB: Mechanical Option
168542CYL-WK3-W - Cylinder lock with key No. (#R503) - Class 100100703: FA-ACB: Mechanical Option
168543CYL-WK4-W - Cylinder lock with key No. (#R504) - Class 100100703: FA-ACB: Mechanical Option
168544CYL-NK-W - Castell lock without key - Class 100100703: FA-ACB: Mechanical Option
168545DI-F-W - Door interlock for fixed type - Class 100100703: FA-ACB: Mechanical Option
168547MIP-W - Mis insertion preventer (up to AE4000-SWA frame) - Class 100100703: FA-ACB: Mechanical Option
168548SBC-1-W - Shorting b-contact for 1 NC Auxiliary switch (mountable at cradle) - Class 100100704: FA-ACB: Electrical Option
168552WS1-W - Main setting module for general protection use - Class 100100704: FA-ACB: Electrical Option
168554WM1-W - Main setting module for generator protection use - Class 100100704: FA-ACB: Electrical Option
168558G1-W - Optional setting module for ground fault protection - Class 100100704: FA-ACB: Electrical Option
168559E1-W - Optional setting module for earth leakage protection - Class 100100704: FA-ACB: Electrical Option
168560AP-W - Optional setting module for 2nd Additional Pre-alarm - Class 100100704: FA-ACB: Electrical Option
168561N5-W - Optional setting module for Neutral pole 50% protection - Class 100100704: FA-ACB: Electrical Option
168562PW4-W - Power supply DC 24 - 60V with output contact - Class 100100704: FA-ACB: Electrical Option
168563PW5-W - Power supply DC 100 - 240V with output contact - Class 100100704: FA-ACB: Electrical Option
168564EX1-W - Extension module for display and interface function - Class 100100704: FA-ACB: Electrical Option
168565DP1-W - Display module - Class 100100704: FA-ACB: Electrical Option
168566DP2-W - Display module onto panel board - Class 100100704: FA-ACB: Electrical Option
168567VT-W - VT unit enable to measures - Class 100100704: FA-ACB: Electrical Option
168570MCS-W - MCR Switch for MCR function - Class 100100704: FA-ACB: Electrical Option
168573BIF-MD-W - Interface Unit - Modbus - Class 100100704: FA-ACB: Electrical Option
168574BIF-CON-W - I/O Unit for breaker remote control - Class 100100704: FA-ACB: Electrical Option
168575BIF-CL-W - Drawout position switch for network - Class 100100704: FA-ACB: Electrical Option
168960DUC-W - Dust cover IP54 - Class 100100703: FA-ACB: Mechanical Option
168961HAX-10-W - Auxiliary switch; 5a5b for high DC capacity - Class 100100704: FA-ACB: Electrical Option
168962AX-10-W - Auxiliary; switch 5a5b - Class 100100704: FA-ACB: Electrical Option
168963MI-203F-W - Mech.l interlock for 3-pole fixed breakers AE1000-SW - AE1600-SW, AE2000-SWA - Class 100100703: FA-ACB: Mechanical Option
168971MI-IW-W - Wire set for among 3 breakers - Class 100100703: FA-ACB: Mechanical Option
168972TTC-F-W - Terminalcover - transparent for control terminal - Class 100100703: FA-ACB: Mechanical Option
168973SST-203-W - Safety shutter for AE1000-1600-SW, AE2000-SWA 3-poles - Class 100100703: FA-ACB: Mechanical Option
168977TJ-W - Test jumper - Class 100100704: FA-ACB: Electrical Option
168978VTA-02-W - Vertical terminal adapter for AE1000-SW - AE1600-SW (1 pcs.) - Class 100100704: FA-ACB: Electrical Option
168985PW3-W - Power supply AC 100-240V / DC 100-125V with output contact - Class 100100704: FA-ACB: Electrical Option
168989NCT-16-W - Current transformer for neutral pole; 1600A - Class 100100704: FA-ACB: Electrical Option
168997ZT-15B-W - Zero phase Current transformer for transformer ground wire 15mm diameter - Class 100100704: FA-ACB: Electrical Option
168998ZT-30B-W - Zero phase Current transformer for transformer ground wire 30mm diameter - Class 100100704: FA-ACB: Electrical Option
168999ZT-40B-W - Zero phase Current transformer for transformer ground wire 40mm diameter - Class 100100704: FA-ACB: Electrical Option
169000ZT-60B-W - Zero phase Current transformer for transformer ground wire 60mm diameter - Class 100100704: FA-ACB: Electrical Option
169001ZT-80B-W - Zero phase Current transformer for transformer ground wire 80mm diameter - Class 100100704: FA-ACB: Electrical Option
169002ZT-100B-W - Zero phase Current transformer for transformer ground wire 100mm diameter - Class 100100704: FA-ACB: Electrical Option
169331FTA-163F-W - Front terminal adapter set for AE1000-SW - 1600-SW 3-pole fixed type (6 pcs.) - Class 100100703: FA-ACB: Mechanical Option
169333FTA-253F-W - Front terminal adapter set for AE2000-SW - 2500-SW 3-pole fixed type (6 pcs.) - Class 100100703: FA-ACB: Mechanical Option
170078CRD163-W - Cradle with horizontal connections for AE1000-1600-SW 3 poles - Class 100100703: FA-ACB: Mechanical Option
202337SBC-2-W - Shorting b-contact for 2 NC Auxiliary switch (mountable at cradle) - Class 100100704: FA-ACB: Electrical Option
202338SBC-3-W - Shorting b-contact for 3 NC Auxiliary switch (mountable at cradle) - Class 100100704: FA-ACB: Electrical Option
202340SBC-5-W - Shorting b-contact for 5 NC Auxiliary switch (mountable at cradle) - Class 100100704: FA-ACB: Electrical Option
203340UCON-A240A-W(INST) - Controller; AC 200 - 240V Inst. trip (Time delay adj.), a-contact - Class 100100704: FA-ACB: Electrical Option
203341UCON-D024B-W(INST) - Controller; DC 24V Inst. trip (Time delay adj.), b-contact - Class 100100704: FA-ACB: Electrical Option
203342UCON-D048B-W(INST) - Controller; DC 48V Inst. trip (Time delay adj.), b-contact - Class 100100704: FA-ACB: Electrical Option
203343UCON-D110B-W(INST) - Controller; DC 100 - 110V Inst. trip (Time delay adj.), b-contact - Class 100100704: FA-ACB: Electrical Option
203344UCON-D125B-W(INST) - Controller; DC 120 - 125V Inst. trip (Time delay adj.), b-contact - Class 100100704: FA-ACB: Electrical Option
203345UCON-D250B-W(INST) - Controller; DC 220 - 250V Inst. trip (Time delay adj.), b-contact - Class 100100704: FA-ACB: Electrical Option
203346UCON-A120B-W(INST) - Controller; AC 100 - 120V Inst. trip (Time delay adj.), b-contact - Class 100100704: FA-ACB: Electrical Option
203347UCON-A240B-W(INST) - Undervoltage Trip Device; AC200-240V; Inst. trip (Time delay adj.); b-contact - Class 100100704: FA-ACB: Electrical Option
203348UCON-A460B-W(INST) - Controller; AC 380 - 460V Inst. trip (Time delay adj.), b-contact - Class 100100704: FA-ACB: Electrical Option
233426Y-2005 - Portable tester unit to check of tripmechanism and relay adjustment - Class 100100704: FA-ACB: Electrical Option
588205UCON-A460A-W(INST) - Controller; AC 380 - 460V Inst. trip (Time delay adj.), a-contact - Class 100100704: FA-ACB: Electrical Option

Document last updated: 19.08.2025 - Subject to change

PDF preview unavailable. Download the PDF instead.

000000000000703298 20250819 mitsubishi factsheet Adobe LiveCycle Designer 11.0 Adobe XML Form Module Library

Related Documents

Preview Mitsubishi Electric AE2500-SW Air Circuit Breaker - Material Fact Sheet
Comprehensive material fact sheet for the Mitsubishi Electric AE2500-SW 3P F TAL ETRBASE-P3 AX10 2500A air circuit breaker, detailing technical specifications, dimensions, compliance, and compatible accessories.
Preview Mitsubishi Electric AE630-SW Air Circuit Breaker - Technical Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric AE630-SW 3P F TAL ETRBASE-P3 AX10 630A Air Circuit Breaker, including specifications, dimensions, compliance, and product data.
Preview Mitsubishi AE4000-SWA 3P F 4000A Air Circuit Breaker - Technical Datasheet
Comprehensive technical datasheet for the Mitsubishi Electric AE4000-SWA 3P F 4000A Air Circuit Breaker. Details specifications, dimensions, compliance, and compatible accessories for industrial applications.
Preview Mitsubishi Electric AE1000-SW 3P F 1000A Air Circuit Breaker - Material Fact Sheet
Material fact sheet for the Mitsubishi Electric AE1000-SW 3P F 1000A Air Circuit Breaker, detailing technical specifications, dimensions, weight, stock data, environmental compliance, and compatible products.
Preview Mitsubishi Electric AE2000-SWA 3P F 2000A Air Circuit Breaker Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric AE2000-SWA 3P F 2000A Air Circuit Breaker, including specifications, dimensions, environmental compliance, conformity, documentation links, and compatible accessories.
Preview Mitsubishi Electric AE6300-SW 4P F 6300A HN Air Circuit Breaker Material Fact Sheet
Comprehensive material fact sheet for the Mitsubishi Electric AE6300-SW 4P F 6300A HN Air Circuit Breaker, detailing technical specifications, dimensions, stock information, export data, environmental compliance, and conformity certifications.
Preview Mitsubishi Electric AE1250-SW 4P Air Circuit Breaker - Material Fact Sheet
Detailed material fact sheet for the Mitsubishi Electric AE1250-SW 4P Air Circuit Breaker, including specifications, dimensions, weight, and compatible accessories.
Preview Mitsubishi Electric DSN1600-SW 4P 1600A Material Fact Sheet
Technical specifications and material fact sheet for the Mitsubishi Electric DSN1600-SW 4P 1600A Moulded-Case Circuit Breaker (MCCB), detailing dimensions, weight, stock data, life cycle, export information, environmental compliance, and product packaging.