Mitsubishi Electric AE1250-SW 4P Air Circuit Breaker - Material Fact Sheet
Document Number: 193922
General Data
Product Hierarchy: ACB
Ext. Material Group: AE-SW Body
IAN Indicator: IAN20107
e-shop Link: https://mitsubishi-electric-eshop.mee.com/mee/FA_IA/EUR/en/p/000000000000588205
FA-ACB: Air Circuit Breaker Specifications
Specification | Value |
---|---|
Series | AE-SW SERIES |
Type | FIXED TYPE |
Frame Size | 1250 |
Rated Voltage (V) | 690 |
Number of Poles | 4 |
Rated Current (A) | 1250 |
Current Type | AC |
Current Range Ir (A) | 625-1250 |
Breaking Capacity at 500V (kA) | 65 |
Compliant with Standard(s) | EN60947-2, IEC60947-2, JIS C 8201-2-1 |
Cycles with Rated Current | 5000 |
Cycles without Rated Current | 25000 |
No of Auxiliary Contacts NO | 5 |
No of Auxiliary Contacts NC | 5 |
Internal Power Supply (V) | 100-240 AC / 100-125 DC |
Power consumption (W) | 38 |
Automatic Tripping Device | ELECTRONIC |
Product Dimensions & Weight
Dimension | Value |
---|---|
Width (mm) | 425 |
Height (mm) | 410 |
Depth (mm) | 290 |
Weight (kg) | 51 |
Logistic Dimensions & Gross Weight
Dimension | Value |
---|---|
Length (cm) | 65.0 |
Width (cm) | 57.0 |
Height (cm) | 61.0 |
Gross Weight (kg) | 67.000 |
Volume (cdm) | 226.005 |
Stock Data
Planned Delivery Time (Days): 92
Life Cycle
Sales Start: 26.12.2006
Predecessor: No Predecessor
Additional Product Information
Battery included: NO
Export Data
Commodity Code: 85365080
Legal Control (Dual Use List): Not Listed
Environmental & Conformity
Category | Detail |
---|---|
Country of Origin | Japan (JP) |
Preference Status (Supplier Declaration) | Non EU |
REACH Limit Exceeded | NO |
Dangerous Goods Class | NO |
Dangerous Goods Identifier | NO |
RoHS Compliance | COMPLIANT |
WEEE | B2B |
CE | COMPLIANT |
UL/cUL | NON-COMPLIANT |
EAC | NON-COMPLIANT |
Shipping Approvals | ABS, BV, CCS, DNV-GL, LR, NK |
UKCA | COMPLIANT |
Documentation & Media Data
- Manual URL: https://emea.mitsubishielectric.com/fa/advanced-search?ct=document&doc-cats=bltdae25c2bd5f2ff94&q=AE1250-SW%204P,%20BARE,%20FIXED,%20AX10&doc-lang=en
- Certificates URL: https://emea.mitsubishielectric.com/fa/advanced-search?ct=document&doc-cats=blt8050dd1408c11cc2&q=AE1250-SW%204P,%20BARE,%20FIXED,%20AX10&doc-lang=en
- CAD URL: https://emea.mitsubishielectric.com/fa/advanced-search?ct=document&doc-cats=blt26ecc97a31a841c1&q=AE1250-SW%204P,%20BARE,%20FIXED,%20AX10&doc-lang=en
Product Packaging
Material | Weight (g) |
---|---|
Cardboard | 3000 |
Other paper | 0 |
Aluminum | 0 |
Steel | 348 |
Styrofoam | 0 |
Other plastic | 0 |
Wood | 7500 |
Glass | 0 |
Others | 0 |
Compatible Products
Material | Description / Price List Text / Classification |
---|---|
168510 | SST-LOCK-W, Shutter lock (for padlock), Class 100100703: FA-ACB: Mechanical Option |
168512 | CL-4-W, Cell switch 2C1T1D, Class 100100704: FA-ACB: Electrical Option |
168513 | DF-W, Door frame, Class 100100703: FA-ACB: Mechanical Option |
168514 | MD-AD125-W, Motor charging device; AC/DC 100 - 125V, Class 100100704: FA-ACB: Electrical Option |
168515 | MD-AD250-W, Motor charging device; AC/DC 200 - 250V, Class 100100704: FA-ACB: Electrical Option |
168518 | MD-D024-W, Motor charging device; DC 24V, Class 100100704: FA-ACB: Electrical Option |
168519 | MD-D048-W, Motor charging device; DC 48V, Class 100100704: FA-ACB: Electrical Option |
168520 | CC-AD250-W, Closing coil; AC/DC 100 - 250V, Class 100100704: FA-ACB: Electrical Option |
168521 | CC-D048-W, Closing coil; DC 24 - 48V, Class 100100704: FA-ACB: Electrical Option |
168522 | SHT-AD250-W, Shunt release; AC/DC 100 - 250V, Class 100100704: FA-ACB: Electrical Option |
168523 | SHT-A500-W, Shunt release; AC/DC 380 - 500V, Class 100100704: FA-ACB: Electrical Option |
168524 | SHT-D048-W, Shunt release; DC 24 - 48V, Class 100100704: FA-ACB: Electrical Option |
168526 | UCONLABEL-W, Label for Under voltage trip controller, Class 100100704: FA-ACB: Electrical Option |
168535 | TCA-AL-W, Trip coil (Auto reset type) with OCR alarm, Class 100100704: FA-ACB: Electrical Option |
168536 | TCM-AL-W, Trip coil (Manual reset type) with OCR alarm, Class 100100704: FA-ACB: Electrical Option |
168537 | BCL-W, Push button cover, Class 100100703: FA-ACB: Mechanical Option |
168538 | CNT-W, Counter, Class 100100704: FA-ACB: Electrical Option |
168539 | CYL-WK-W, Cylinder lock with key No. (#R0220) - Standard, Class 100100703: FA-ACB: Mechanical Option |
168540 | CYL-WK1-W, Cylinder lock with key No. (#R501), Class 100100703: FA-ACB: Mechanical Option |
168541 | CYL-WK2-W, Cylinder lock with key No. (#R502), Class 100100703: FA-ACB: Mechanical Option |
168542 | CYL-WK3-W, Cylinder lock with key No. (#R503), Class 100100703: FA-ACB: Mechanical Option |
168543 | CYL-WK4-W, Cylinder lock with key No. (#R504), Class 100100703: FA-ACB: Mechanical Option |
168544 | CYL-NK-W, Castell lock without key, Class 100100703: FA-ACB: Mechanical Option |
168545 | DI-F-W, Door interlock for fixed type, Class 100100703: FA-ACB: Mechanical Option |
168547 | MIP-W, Mis insertion preventer (up to AE4000-SWA frame), Class 100100703: FA-ACB: Mechanical Option |
168548 | SBC-1-W, Shorting b-contact for 1 NC Auxiliary switch (mountable at cradle), Class 100100704: FA-ACB: Electrical Option |
168552 | WS1-W, Main setting module for general protection use, Class 100100704: FA-ACB: Electrical Option |
168554 | WM1-W, Main setting module for generator protection use, Class 100100704: FA-ACB: Electrical Option |
168558 | G1-W, Optional setting module for ground fault protection, Class 100100704: FA-ACB: Electrical Option |
168559 | E1-W, Optional setting module for earth leakage protection, Class 100100704: FA-ACB: Electrical Option |
168560 | AP-W, Optional setting module for 2nd Additional Pre-alarm, Class 100100704: FA-ACB: Electrical Option |
168561 | N5-W, Optional setting module for Neutral pole 50% protection, Class 100100704: FA-ACB: Electrical Option |
168562 | PW4-W, Power supply DC 24 - 60V with output contact, Class 100100704: FA-ACB: Electrical Option |
168563 | PW5-W, Power supply DC 100 - 240V with output contact, Class 100100704: FA-ACB: Electrical Option |
168564 | EX1-W, Extension module for display and interface function, Class 100100704: FA-ACB: Electrical Option |
168565 | DP1-W, Display module, Class 100100704: FA-ACB: Electrical Option |
168566 | DP2-W, Display module onto panel board, Class 100100704: FA-ACB: Electrical Option |
168567 | VT-W, VT unit enable to measures, Class 100100704: FA-ACB: Electrical Option |
168570 | MCS-W, MCR Switch for MCR function, Class 100100704: FA-ACB: Electrical Option |
168571 | BIF-CC-W, Interface Unit - CC-Link, Class 100100704: FA-ACB: Electrical Option |
168573 | BIF-MD-W, Interface Unit - Modbus, Class 100100704: FA-ACB: Electrical Option |
168574 | BIF-CON-W, I/O Unit for breaker remote control, Class 100100704: FA-ACB: Electrical Option |
168575 | BIF-CL-W, Drawout position switch for network, Class 100100704: FA-ACB: Electrical Option |
168960 | DUC-W, Dust cover IP54, Class 100100703: FA-ACB: Mechanical Option |
168961 | HAX-10-W, Auxiliary switch; 5a5b for high DC capacity, Class 100100704: FA-ACB: Electrical Option |
168962 | AX-10-W, Auxiliary; switch 5a5b, Class 100100704: FA-ACB: Electrical Option |
168964 | MI-204F-W, Mech.I interlock for 4-pole fixed breakers AE1000-SW - AE1600-SW, AE2000-SWA, Class 100100703: FA-ACB: Mechanical Option |
168971 | MI-IW-W, Wire set for among 3 breakers, Class 100100703: FA-ACB: Mechanical Option |
168972 | TTC-F-W, Terminal cover - transparent for control terminal, Class 100100703: FA-ACB: Mechanical Option |
168974 | SST-204-W, Safety shutter for AE1000-1600-SW, AE2000-SWA 4-poles, Class 100100703: FA-ACB: Mechanical Option |
168977 | TJ-W, Test jumper, Class 100100704: FA-ACB: Electrical Option |
168978 | VTA-02-W, Vertical terminal adapter for AE1000-SW - AE1600-SW (1 pcs.), Class 100100704: FA-ACB: Electrical Option |
168985 | PW3-W, Power supply AC 100-240V / DC 100-125V with output contact, Class 100100704: FA-ACB: Electrical Option |
168988 | NCT-12-W, Current transformer for neutral pole; 1250A, Class 100100704: FA-ACB: Electrical Option |
168997 | ZT-15B-W, Zero phase Current transformer for transformer ground wire 15mm diameter, Class 100100704: FA-ACB: Electrical Option |
168998 | ZT-30B-W, Zero phase Current transformer for transformer ground wire 30mm diameter, Class 100100704: FA-ACB: Electrical Option |
168999 | ZT-40B-W, Zero phase Current transformer for transformer ground wire 40mm diameter, Class 100100704: FA-ACB: Electrical Option |
169000 | ZT-60B-W, Zero phase Current transformer for transformer ground wire 60mm diameter, Class 100100704: FA-ACB: Electrical Option |
169001 | ZT-80B-W, Zero phase Current transformer for transformer ground wire 80mm diameter, Class 100100704: FA-ACB: Electrical Option |
169002 | ZT-100B-W, Zero phase Current transformer for transformer ground wire 100mm diameter, Class 100100704: FA-ACB: Electrical Option |
169332 | FTA-164F-W, Front terminal adapter set for AE1000-SW - 1600-SW 4-pole fixed type (8 pcs.), Class 100100703: FA-ACB: Mechanical Option |
169338 | FTA-164D-W, Front terminal adapter set for AE1000-SW - 1600-SW 4-pole drawout type (8 pcs.), Class 100100703: FA-ACB: Mechanical Option |
170079 | CRD164-W, Cradle with horizontal connections for AE1000-1600-SW 4 poles, Class 100100703: FA-ACB: Mechanical Option |
202337 | SBC-2-W, Shorting b-contact for 2 NC Auxiliary switch (mountable at cradle), Class 100100704: FA-ACB: Electrical Option |
202338 | SBC-3-W, Shorting b-contact for 3 NC Auxiliary switch (mountable at cradle), Class 100100704: FA-ACB: Electrical Option |
202340 | SBC-5-W, Shorting b-contact for 5 NC Auxiliary switch (mountable at cradle), Class 100100704: FA-ACB: Electrical Option |
203340 | UCON-A240A-W(INST), Controller; AC 200 - 240V Inst. trip (Time delay adj.), a-contact, Class 100100704: FA-ACB: Electrical Option |
203341 | UCON-D024B-W(INST), Controller; DC 24V Inst. trip (Time delay adj.), b-contact, Class 100100704: FA-ACB: Electrical Option |
203342 | UCON-D048B-W(INST), Controller; DC 48V Inst. trip (Time delay adj.), b-contact, Class 100100704: FA-ACB: Electrical Option |
203343 | UCON-D110B-W(INST), Controller; DC 100 - 110V Inst. trip (Time delay adj.), b-contact, Class 100100704: FA-ACB: Electrical Option |
203344 | UCON-D125B-W(INST), Controller; DC 120 - 125V Inst. trip (Time delay adj.), b-contact, Class 100100704: FA-ACB: Electrical Option |
203345 | UCON-D250B-W(INST), Controller; DC 220 - 250V Inst. trip (Time delay adj.), b-contact, Class 100100704: FA-ACB: Electrical Option |
203346 | UCON-A120B-W(INST), Controller; AC 100 - 120V Inst. trip (Time delay adj.), b-contact, Class 100100704: FA-ACB: Electrical Option |
203347 | UCON-A240B-W(INST), Undervoltage Trip Device; AC200-240V; Inst. trip (Time delay adj.); b-contact, Class 100100704: FA-ACB: Electrical Option |
203348 | UCON-A460B-W(INST), Controller; AC 380 - 460V Inst. trip (Time delay adj.), b-contact, Class 100100704: FA-ACB: Electrical Option |
233426 | Y-2005, Portable tester unit to check of tripmechanism and relay adjustment, Class 100100704: FA-ACB: Electrical Option |
588205 | UCON-A460A-W(INST), Controller; AC 380 - 460V Inst. trip (Time delay adj.), a-contact, Class 100100704: FA-ACB: Electrical Option |