OVATION F-165WW Quick Reference Guide

About this Guide

The OVATION F-165WW Quick Reference Guide (QRG) provides basic product information including connection, mounting, menu options, and DMX values. For more detailed information, download the User Manual from www.chauvetprofessional.com.

Disclaimer

The information and specifications in this QRG are subject to change without notice.

Safety Notes

  • DO NOT open this product. It contains no user-serviceable parts.
  • DO NOT look at the light source when the product is on.
  • To prevent unnecessary wear and prolong lifespan, disconnect the product from power during periods of non-use (via breaker or unplugging).
  • CAUTION: When transferring the product between extreme temperature environments (e.g., from a cold truck to a warm, humid ballroom), condensation may form on internal electronics. To avoid failure, allow the product to fully acclimate to the surrounding environment before connecting to power.
  • CAUTION: This product's housing may be hot when lights are operating.
  • Mount this product in a location with adequate ventilation, at least 20 inches (50 cm) from adjacent surfaces.
  • DO NOT place flammable material within 50 cm of this product while operating or connected to power.
  • USE a safety cable when mounting this product overhead.
  • DO NOT operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect it.
  • DO NOT operate this product if the housing, lenses, or cables appear damaged.
  • DO NOT connect this product to a dimmer or rheostat.
  • ONLY connect this product to a grounded and protected circuit.
  • ONLY use the hanging bracket to carry this product.
  • In case of a serious operating problem, stop using immediately.
  • The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.

Contact Information

For support or returns outside the U.S., United Kingdom, or Ireland, contact your distributor. Visit www.chauvetlighting.com for contact details.

What is Included

  • OVATION F-165WW fixture
  • Neutrik® powerCON® power cord
  • Safety Cable
  • Gel frame (7.5 in/191 mm accessories)
  • Warranty Card
  • Quick Reference Guide

AC Power

This product features an auto-ranging power supply compatible with input voltage ranges of 100–240 VAC, 50/60 Hz.

Power Linking

Up to 4 OVATION F-165WW products can be linked at 120 VAC, or 7 products at 230 VAC. Do not exceed this number. Power linking cords are sold separately.

AC Plug Wiring

ConnectionWire (U.S.)Wire (Europe)Screw Color
AC LiveBlackBrownYellow/Brass
AC NeutralWhiteBlueSilver
AC GroundGreen/YellowGreen/YellowGreen

Replacing the Fuse

  1. Disconnect the product from power.
  2. Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from the housing.
  3. Remove the blown fuse and replace it with a good fuse of the same type and rating.
  4. Screw the fuse holder cap back in place and reconnect power.

DMX Linking

The OVATION F-165WW works with a DMX controller via a standard DMX serial connection. A DMX Primer is available at www.chauvetprofessional.com.

DMX Connection

The OVATION F-165WW supports DMX data connections for its DMX personalities: UNO, DOS, and STD.P. Refer to the User Manual for connection and configuration details.

Master Control

The OVATION F-165WW can control other OVATION F-165WW products using a standard DMX data connection. Consult the User Manual for Master Control configuration.

Master/Slave Connection

The OVATION F-165WW uses the DMX data connection for its Master/Slave mode. Refer to the User Manual for connection and configuration.

Mounting

Product Diagram

The product diagram illustrates the OVATION F-165WW fixture. It shows the mounting yoke and points for attaching a safety cable. The safety cable should be secured using the passageway on the side of the product.

Overhead Mounting

When mounting overhead, ensure the safety cable is securely attached to the designated point on the fixture.

Control Panel

Description

Button/KnobFunction
<MENU>Exits the current menu or function.
<ENTER>Enables the currently displayed menu or sets the currently selected value into the selected function.
<UP>Navigates upwards through the menu list and increases the numeric value when in a function.
<DOWN>Navigates downwards through the menu list and decreases the numeric value when in a function.
<DIM>Press twice rapidly to access the dimmer function. Use the knob to adjust dimmer intensity.
<ZOOM>Press twice rapidly to access the zoom function. Use the knob to adjust the zoom.

Passcode

When prompted, enter the following password: <UP>, <DOWN>, <UP>, <DOWN>, <ENTER>. This password cannot be changed and must be used whenever prompted.

Menu Options

Main Level: STAT

Programming LevelsDescription
DIMLocal control of output
ZOOMLocal control of zoom lens

Main Level: RUN

Programming LevelsDescription
DMXSets the mode to Master/Slave
SLAVSets the mode to Master/Slave

Main Level: ADDR

Programming LevelsDescription
D.001-D.512Sets the starting address

Main Level: MOTR

Programming LevelsDescription
YESResets the Zoom motor
NOResets the Zoom motor

Main Level: SET

Programming LevelsDescription
KEY OFFSets the key lock (password mode).
KEY ONSets the key lock (password mode).
DIMX DIM1Slow (DIM4) to fast (DIM1) dimmer speeds.
DIMX DIM2Slow (DIM4) to fast (DIM1) dimmer speeds.
DIMX DIM3Slow (DIM4) to fast (DIM1) dimmer speeds.
DIMX DIM4Slow (DIM4) to fast (DIM1) dimmer speeds.
CURV CV1Large (CV3) to small (CV1) dimmer curves.
CURV CV2Large (CV3) to small (CV1) dimmer curves.
CURV CV3Large (CV3) to small (CV1) dimmer curves.
CURV OFFLarge (CV3) to small (CV1) dimmer curves.

Main Level: SET (Cont.)

Programming LevelsDescription
REST (Enter Passcode) REST OKResets fixture to factory defaults.
PERS UNOSelects DMX personality.
PERS DOSSelects DMX personality.
PERS STD.PSelects DMX personality.
SLCK OFFSET menu level access lock.
SLCK ONSET menu level access lock.
DERR BLAKBlacks out fixture upon loss of DMX.
DERR SAVEContinues with last command upon loss of DMX control.
ZOOM BASESets default zoom position (full movement).
ZOOM POS1Sets position 1 setting for zoom limit.
ZOOM POS2Sets position 2 setting for zoom limit.
PERF LIVEBalances LED cooling using fans and output power level.
PERF STDOMaintains LED cooling by limiting output power level.
PERF POWRMaintains LED cooling using fans allowing full power output.
MCON SELFNo DMX data is sent in standalone operation.
MCON MASTSends DMX data to other OVATION F-165WW during standalone operation.

Main Level: CAL

Programming LevelsDescription
**** (Enter Passcode) CALZ POS1Sets min/max position of zoom (000-255).
**** (Enter Passcode) CALZ POS2Sets min/max position of zoom (000-255).

DMX Values

UNO

ChannelFunctionValuePercent/Setting
1Dimmer000 – 2550–100%

DOS

ChannelFunctionValuePercent/Setting
1Dimmer000 – 2550–100%
2Dimmer Fine000 – 2550–100%

STD.P

ChannelFunctionValuePercent/Setting
1Dimmer000 – 2550–100%
2Dimmer Fine000 – 2550–100%
3Strobe000 – 009No Function
010 – 099Strobe (slow to fast)
100 – 109No Function
110 – 179Lighting Effect
180 – 189No Function
190 – 255Random Strobe
4Zoom000 – 2550–100%
5Motor Reset000 – 200No Function
201 – 220Motor Reset
221 – 255No Function

PDF preview unavailable. Download the PDF instead.

Ovation F-165WW QRG Rev4 ML WO Daniel Couppe Adobe PDF Library 10.0

Related Documents

Preview Ovation B-1965FC User Manual - CHAUVET Professional
Comprehensive user manual for the CHAUVET Professional Ovation B-1965FC, detailing installation, setup, operation, programming, and technical specifications for this advanced LED lighting fixture.
Preview Chauvet Professional Ovation E-2 FC User Manual: Installation, Operation, and Specifications
Comprehensive user manual for the Chauvet Professional Ovation E-2 FC LED ellipsoidal spotlight, covering installation, setup, operation, DMX control, maintenance, and technical specifications.
Preview CHAUVET Professional COLORado Solo Bar 6 Quick Reference Guide
This guide provides essential information for the installation, use, and maintenance of the CHAUVET Professional COLORado Solo Bar 6 LED lighting fixture. It covers safety precautions, power specifications, mounting instructions, and control panel functions.
Preview CHAUVET PROFESSIONAL Rogue Outcast 1L Beam User Manual | Setup, Operation, Maintenance
Comprehensive user manual for the CHAUVET PROFESSIONAL Rogue Outcast 1L Beam IP65 moving head beam fixture. Details installation, setup, DMX control, operation, maintenance, and technical specifications for professional stage lighting.
Preview Chauvet Professional COLORado PXL Curve 12 User Manual
Comprehensive user manual for the Chauvet Professional COLORado PXL Curve 12, detailing installation, operation, programming, technical specifications, and maintenance procedures for this professional LED lighting fixture.
Preview Chauvet Rogue R1 Wash DMX Chart
A comprehensive DMX chart detailing the channel assignments, functions, values, and settings for the Chauvet Rogue R1 Wash lighting fixture.
Preview Chauvet Professional Maverick Storm 3 BeamWash User Manual
Comprehensive user manual for the Chauvet Professional Maverick Storm 3 BeamWash lighting fixture, covering installation, operation, and maintenance for professional lighting applications. Features dual-zone zoom, RGBW LEDs, and IP65 rating.
Preview CHAUVET PROFESSIONAL WELL Fit DMX Chart
Detailed DMX value chart for the CHAUVET PROFESSIONAL WELL Fit lighting fixture, covering 10-channel, 6-channel, 4-channel, HSV, and HSI modes.