Finder 13.61 Multifunction Step/Monostable Relay
Model: 13.61.0.024.0000
Standards: EN 60669-1 / EN 60669-2-1
Product Overview
The Finder 13.61 is a multifunction step/monostable relay designed for 35 mm rail mounting (EN 60715) and is suitable for 3 or 4 wire systems. It features set and reset commands for operation.
Specifications
- Supply Voltage (UN): 12...24 V AC (50/60 Hz) / DC
- Minimum Supply Voltage (Umin): 10.2 V AC / DC
- Maximum Supply Voltage (Umax): 26.4 V AC / DC
- Power Consumption (P): 1 VA / 0.5 W
- Output Contacts: 1 CO (SPDT)
- Contact Rating (AC1): 16 A 250 V AC / 4000 VA
- Contact Rating (AC15): 750 VA (230 V AC)
- Maximum Switching Power (AC1): 2000 W (230 V AC)
- Maximum Switching Power (AC15): 750 W (230 V AC)
- CFL LED Rating: 400 W (230 V AC)
- Operating Temperature: -10...+60 °C
- Protection Rating: IP20
Connection Diagram
1 CONNECTION DIAGRAM
- ON: SET (centralized switch on)
- OFF: RESET (centralised switch off)
The diagram shows a relay with terminals labeled A1, A2, and switch contacts.
Front View
2 FRONT VIEW
- A: Function rotary selector
- B: Time adjustment trimmer (0.5-20 minutes)
- C: LED status indicator (continuous = relay ON, blinking = relay OFF)
Dimensions are provided: 88.8 mm height, 60.8 mm width, 17.5 mm depth.
Functions
3 FUNCTIONS
- 3a: RI Step relay
- 3b: IT Timing step relay
- 3c: RM Monostable relay
- 3d: Light on
Timing diagrams illustrate the operation of the step and timing step relays, showing ON/OFF states and time delays (T≥3s, T≥1s).
Notes and Working Conditions
- Note: Maximum cable length for push-button connection is 200 m. Maximum impulse duration is continuous.
- WORKING CONDITIONS: In conformity with the European Directive on EMC (2014/30/EU), the relay exhibits a high level of immunity to radiated and conducted disturbances, exceeding the requirements of EN 60669-1 and EN 60669-2-1 standards.
- To prevent potential disturbances or damage to the electronic circuit from devices like transformers, motors, contactors, switches, and power cables, it is recommended to keep wiring cables as short as possible. Where necessary, protect the timer with an RC network, varistor, or surge voltage protector.
Terminal and Wire Specifications
- Terminal Size: 1x6 / 2x4 mm² for solid wire, 1x10 / 2x12 AWG for flexible wire.
- Terminal Size: 1x4 / 2x2.5 mm² for solid wire, 1x12 / 2x14 AWG for flexible wire.
- Torque: 0.8 Nm