Complete LED Lighting Solutions

WARNING

TO AVOID RISK OF ELECTRICAL SHOCK, SHUT OFF POWER BEFORE INSTALLING OR SERVICING THIS FIXTURE

Assembly & Installation: GT-2PK-T8-SLH | T8 LED Bulb (2pk) Ballast Bypass

Safety Precautions

WARNING

⚠️ When using product, basic precautions should always be followed.

Read and follow these instructions and heed all warnings.

Carefully read and understand the information given in this manual before beginning installation. Failure to do so could lead to electric shock, fire, or other injuries which could be hazardous or even fatal.

Save these instructions and warnings.

CAUTION

⚠️ If the lamp or luminaire exhibits undesirable operation (buzzing, flickering, etc.) immediately turn off power, remove lamp from the luminaire, and contact manufacturer.

Risk of fire. Perform a visual inspection to ensure lampholders are not damaged or loose before installing and turning on this lamp.

If lamp does not light when the luminaire is energized, remove lamp from luminaire and contact lamp manufacturer or qualified electrician.

Reliable operating temperature: -4°F to +113°F (-20°C to +45°C).

These devices are not intended for use with emergency exit lights.

This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45 - 30MHZ.

Kit Includes

  • Installation Booklet
  • (2) T8 Ballast Bypass Bulbs

Compatibility

Compatible With:

  • Shunted Lampholder ✔️
  • Non-Shunted Lampholder ✔️

Fixture Compatibility:

  • These bulbs should only be installed in properly bypassed 48" T8 fixtures.
  • This bulb is only compatible with ballast bypass fixtures. The bulb will not operate correctly with any ballast.
  • This lamp can be used with shunted and non-shunted lamp holders, but requires different wiring schematics for each type of lampholder.
  • It is your responsibility to ensure that your fixture has been properly wired for this bulb. If you are unsure, contact a qualified electrician or the manufacturer.

Installation Instructions

General Precautions

IF NOT QUALIFIED DO NOT ATTEMPT INSTALLATION:

  • Contact a certified electrician to install these bulbs if you are not properly qualified.

Risk of Electric Shock or Fire

  • Risk of Electric Shock is present when working with electrical components.
  • Do not drill holes in the fixture that could affect the internal wiring.

Prevent Electric Wire Abrasions

  • Do not expose wiring to edges of the fixture or other sharp objects. This can cause abrasion and damage the wiring, greatly increasing risk of electrical shock or fire.

Bulb Installation Steps

  1. TURN OFF POWER AT THE BREAKER OR FUSE PANEL. (TURNING OFF POWER AT THE WALL SWITCH IS NOT A SUFFICIENT SAFETY PRECAUTION)
  2. Double check the rating of the lamp (120-277VAC) matches the voltage of the current circuit.
  3. Check to see if the fixture is compatible with the bulbs (Ballast Bypass, Shunted/Non-Shunted).
  4. Check all wires for proper connection with no loose ends.
  5. If Ballast is already bypassed, move on to step 5. If ballast is not bypassed, see Diagrams 1, 2, & 3 and follow instructions on the following page.
  6. Take out old bulbs.
  7. Install GT-2PK-T8-SLH bulbs into the new fixture.
  8. Turn Power back on and turn fixture on. If bulbs do not turn on, disconnect power from fixture and proceed to troubleshooting section.

Diagram 1: Bypass Install Steps

This diagram illustrates the ballast bypass installation process:

  • 1. Turn Off Power.
  • 2. Remove existing lamp.
  • 3. Cut all wires attached to ballast.*
  • 4. Connect one end of fixture to line power.
  • 5. Install LED tube.
  • 6. Turn on power.

Ballast Bypass Retrofit Instructions

  1. TURN OFF POWER AT THE BREAKER OR FUSE PANEL. (TURNING OFF POWER AT THE WALL SWITCH IS NOT SUFFICIENT SAFETY PRECAUTION)
  2. Double check the rating of the lamp (120-277VAC) matches the voltage of the current circuit.
  3. Check to see if the fixture has shunted, or non-shunted lampholders.
  4. Take out old bulbs and remove the ballast cover.
  5. Disconnect all wires attached to the ballast as close to the ballast as possible. It is best practice to leave the ballasts in place after doing this.
  6. For Non-Shunted Lampholders:
    • Connect one wire from each lampholder at only one end of the fixture to the back wire.
    • Separately connect the neutral wire (white) to the lampholder after.
    • At the opposite end of the fixture, cut all wires that connect to that lampholder.
    • ENSURE THIS FIXTURE REMAINS GROUNDED AFTER THE RETROFIT PROCESS.
  7. For Shunted Lampholders:
    • Connect one black wire to one lamp holder on one side of the light.
    • Connect the neutral (white) wire to a lamp holder on the opposite side of light.
    • Do this for each bulb in the light fixture.
  8. Replace any removed wiring covers or ballast covers.
  9. Install GT-2PK-T8-SLH bulbs into the new fixture.

Diagram 2: Wiring Schematics

This diagram shows typical wiring for non-shunted and shunted lampholders:

Non-Shunted: Illustrates power from the building (Hot/Line, Neutral) connected to the fixture, bypassing the ballast. Wires are connected to lampholders, with specific connections for shunted/non-shunted types.

Shunted: Shows AC100-277V input, Neutral (N), Line (L) connected to an LED tube, indicating a dual-end ballast bypass configuration.

Diagram 3: Before and After Retrofit

This diagram visually compares the wiring before and after the ballast bypass retrofit:

Before Retrofit: Shows a typical fluorescent fixture with Line (120-277VAC), Neutral, Ballast, and multiple FLUORESCENT LAMPS connected.

After Retrofit: Shows the same fixture with Line (120-277VAC), Neutral, AC INPUT connected to GT-Lite BULBs, indicating the ballast has been removed or bypassed and the LED tubes are directly wired to the power source.

Troubleshooting

Refer to Diagram 4 for troubleshooting common issues:

SymptomCauseRemedy
No Light from LED tubes when powered onFixture wired improperly or loose connections exist
  • Go back over instructions provided in this booklet.
  • Check wire-nuts to make sure connection is strong.
  • Check lampholders at powered end of the fixture to make sure that both bulb pins are receiving power.
  • Contact GT Industrial Products at 1-800-865-6799.
Circuit Breaker detects a fault condition when light switch turned onFixture Wired Improperly
  • Go back over instructions provided in this booklet.
  • Check wire-nuts to make sure connection is strong.
  • Check to make sure your fixture is wired in accordance to its lampholders.
  • Contact GT Industrial Products at 1-800-865-6799.
Only part of the LED tube is lighting upFaulty LED tubeContact GT Industrial Products at 1-800-865-6799.
All Other IssuesNAContact GT Industrial Products at 1-800-865-6799.

Important Safety Notes

[eye-protection-symbol] Do not look directly at the LED lights for any length of time.

[lens-icon] Do not remove protective lens covering LED lights.

GT-Lite Limited Warranty

This product is guaranteed against failure due to factory defects in material and workmanship for 1 year from the date of purchase. Warranty is non-transferable and applies only to the original owner. Warranty is based on 3 hours per day/7 days per week average when product is used as directed only. Warranty does not cover normal wear and tear of parts, or damage resulting from misuse of the product (i.e. using in extreme weather, alterations made to product, neglect, or abuse).

For refund or replacement, call GT-Lite at: 1-800-865-6799 or submit the form at http://gtledlighting.com/contact-us/. Owner must provide proof of purchase and return lamp to GT-Lite to be considered for replacement or refund of original purchase price.

REPLACEMENT OR REFUND IS YOUR SOLE REMEDY, EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW. ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states do not allow exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.

Contact Us

Question/Comment/Missing Part?

Contact GT-Lite: 1-800-865-6799

Visit us online: www.GTLEDLIGHTING.com

Models: GT-2PK-T8-SLH T8 LED Bulb 2pk Ballast Bypass, GT-2PK-T8-SLH, T8 LED Bulb 2pk Ballast Bypass, 2pk Ballast Bypass, Ballast Bypass, Bypass

File Info : application/pdf, 4 Pages, 1,000.90KB

PDF preview unavailable. Download the PDF instead.

GT-LITE GT-2PK-T8-SLH (01)

References

Related Documents

Preview GT-2PK-T8-3IN1 T8 LED Tube Installation Guide
Comprehensive assembly and installation instructions for the GT-2PK-T8-3IN1 T8 LED Tube 5000k (2pk) from GT-Lite. Learn about compatibility, safety precautions, and wiring diagrams for ballast bypass retrofits.
Preview GT-A19-3710-BW 3-Way LED Bulb Installation and Troubleshooting Guide
Comprehensive guide for the GT-A19-3710-BW 3-Way LED Bulb, covering installation, troubleshooting, cleaning, and warranty information. Learn about specifications, safety warnings, and FCC compliance.
Preview GT-Lite GT-BU-G150M Motion Sensing LED Garage Light Installation and Troubleshooting
Comprehensive guide for the GT-Lite GT-BU-G150M 15,000LM/140W Motion Sensing LED Garage Light. Includes installation instructions, troubleshooting tips, safety warnings, and product specifications.
Preview GT-Lite GT-NL-SMS-3 Motion Sensor LED Night Lights - User Guide & Features
Comprehensive guide for GT-Lite GT-NL-SMS-3 3-Pack Motion Sensor LED Night Lights. Learn about installation, usage, warranty, troubleshooting, and FCC compliance for these energy-efficient lights.