Milwaukee M12™ Green Cross Line & 4-Points Laser

Cat. No. / No de cat.: 3624-20

Operator's Manual / Manuel de l'Utilisateur / Manual del Operador

⚠️ To reduce the risk of injury, user must read and understand operator's manual.

General Power Tool Safety Warnings

⚠️ Read all safety warnings, instructions, illustrations and specifications provided with this power tool. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.

The term "power tool" in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.

Laser Safety

⚠️ The device produces visible laser beams, which are emitted from the tool.

Work Area Safety

Personal Safety

Battery Tool Use and Care

Specific Safety Rules for Laser Levels

CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

Be sure to power off instrument after use. When instrument will not be used for a long period, place it in storage after removing batteries.

Federal Communications Commission

⚠️ Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Functional Description

The laser level has the following components:

Symbology

Specifications

Assembly

⚠️ Recharge only with the charger specified for the battery. For specific charging instructions, read the operator's manual supplied with your charger and battery.

Removing/Inserting the Battery

To remove the battery, push in the release buttons and pull the battery pack away from the tool.

⚠️ Always remove the battery pack anytime the tool is not in use.

To insert the battery, slide the pack into the body of the tool. Make sure it latches securely into place.

⚠️ Only use accessories specifically recommended for this tool. Others may be hazardous.

Power Save

Use power save mode to extend the battery run time. Power save mode is indicated by dimmed laser beams and the Power Save Indicator pulsing. Visual range is decreased in power save mode. Power Save Indicator will change from pulsing to solid Green when turned OFF. The tool will automatically switch to power save mode if less than 7% of battery charge remains.

Fuel Gauge

To determine the amount of charge left in the battery, turn the tool ON. When less than 7% of charge is left, 1 light on the fuel gauge will flash continuously. To signal the end of charge, the fuel gauge will flash 4 times and then the tool will shut off. Charge the battery pack. If the battery becomes too hot, the fuel gauge lights will flash. Allow the battery to cool down.

⚠️ To reduce the risk of injury or damage, securely mount/attach the laser before starting an operation. Injury/damage may occur if the laser falls.

Mounting/Adjusting the Laser Level

The pivot bracket can be used to mount the laser level in multiple ways:

Operation

⚠️ To reduce the risk of injury or temporary effects on vision, do not look directly into the laser when it is on.

CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

NOTICE: Perform the Accuracy Field Check procedure immediately upon unboxing of each new Laser Level and before exposure to jobsite conditions. See "Accuracy Field Check" for information.

Turning On/Off

To turn on the laser and unlock the pendulum, rotate the On/Off dial to the desired position. The remaining battery life will be displayed. ⚠️ Do not look directly into laser apertures. Horizontal level line and left/right plumb points will immediately be emitted from aperture in the laser housing.

NOTICE: The ON mode disables self-leveling and therefore is not intended for projecting a level or plumb lines/points.

Use the MODE button to cycle through the three laser modes:

Using the Laser Level

  1. For best results, place the tool on a work surface that is:
    • sturdy
    • level (within 4 degrees of true level)
    • free of vibrations
    • 90° to the work area
  2. Turn on the tool.
  3. The tool will self-level when placed on surfaces within 4 degrees of true level when dial is unlocked and on.
  4. The tool is ready once the emitted lines are continuous and no longer moving on the work surface.
  5. If the tool cannot achieve a level state (i.e., the work surface is > 4 degrees off true level), the laser beams will flash rapidly (3 flashes per second). Relocate or adjust the work surface.

Troubleshooting

If the tool does not turn on:

If problem persists, please contact a MILWAUKEE service facility for support.

Accuracy Field Check

NOTICE: Perform the Accuracy Field Check procedure immediately upon unboxing of each new Laser Level and before exposure to jobsite conditions. See "Accuracy Field Check" for information. Should any deviation from listed product accuracy be found, please contact a MILWAUKEE service facility. Failure to do so could result in rejection of warranty claim.

Influences on Accuracy

Ambient temperature gradients can impact laser accuracy. For accurate and repeatable results, the following procedure should be conducted with the laser elevated off the ground and placed in the center of the working area.

Abusive treatment of the Laser Level, such as excessive impacts from drop, can also lead to deviations in product accuracy. Therefore, it is recommended to conduct the Field Check procedure after any impact or before completing any critical jobs.

Horizontal Height Accuracy

A free measuring distance of approximately 66' on a firm surface between two walls or structures A and B is required for this check. It is also suggested to mount the Laser Level to a Tripod for easy adjustment.

  1. Securely mount the tool within 1' of wall A.
  2. Turn the tool to ON and to Perpendicular Level, Plumb Points, & Horizontal Points mode.
  3. Direct the front laser beam against the nearest wall A and allow to self-level. Mark the center of the laser cross on the wall (point I).
  4. Rotate the tool 180° without changing the height, allow it to self-level, and mark the center of the laser cross on the opposite wall B (point II).

Diagram Description: Two parallel walls, A and B, are shown. A laser level is mounted near wall A. A line is projected from the laser onto wall A (point I) and then onto wall B (point II) after rotating the tool 180°. The distance between walls is indicated as 66'.

Horizontal Leveling Accuracy

A free measuring space of approximately 33'x33' on a firm surface between two walls or structures A and B is required for the check. It is also suggested to mount the Laser Level to a Tripod for easy adjustment.

Securely mount the tool on one side of the room and centered between walls A and B. Direct the laser lines toward the other side of the room such that the horizontal line appears on both walls A and B. Allow the laser to Self-Level.

  1. Turn the tool to ON and to Horizontal Level Line mode and Horizontal Points mode.
  2. Mark the center of the plumb point on the wall (point I). Also, mark the center of the plumb point on the opposite wall (point II).
  3. Rotate the tool 180°. Align the center point of the laser beam directly onto the wall point II.
  4. Mark the center point of the laser beam on wall A (point III).
  5. The distance d between marked points I and III on wall A indicates the actual deviation (d) of the tool.

Diagram Description: A room with walls A and B. A laser level is positioned. Points are marked on the walls (I, II, III). Distances are indicated: 16.5' and 33'. The diagram illustrates the process of marking points on opposite walls after rotating the laser level.

Accuracy Calculation Example: For a measuring distance of 2 x 33' = 66', the maximum allowable deviation (d) is: 66' x ±1/8" ÷ 33' = ±1/4". Thus, the difference d between points I and III should not exceed 1/4" (max.) at 66'.

Vertical Leveling Accuracy

A door opening with approximately 8' of space on each side of the opening is required for this check.

  1. Securely mount the tool 8' from one side of the door opening.
  2. Turn the tool to ON and to Vertical Plumb Line & Plumb Points Mode or Perpendicular Level, Plumb Points, and Horizontal Points mode.
  3. Position the tool with the laser towards the door opening. Allow the tool to self-level.
  4. Mark the center of the vertical laser line on the floor in the middle of the door opening (point I), at a distance of 8' beyond the door opening (point II), and at the upper edge of the door opening (point III).

Diagram Description: A doorway is shown. Points I, II, and III are marked along the vertical line projected by the laser. Distances of 8' are indicated.

  1. Move the laser level directly behind point II on the other side of the door. Align the vertical laser line so the center is directly aligned with points I and II.
  2. Mark the center of the vertical line at the upper edge of the door opening (point IV).
  3. Measure the height of the door opening.
  4. The distance between points III and IV on the upper door opening is the vertical deviation (d) of the tool.

Accuracy Calculation Example: The maximum vertical deviation (d) is: dmax = 2 x H (door opening) x ±1/8" ÷ 33'. For a door opening height of 7', the maximum permitted deviation (d) is: dmax = 2 x 7' x ±1/8" ÷ 33' = ±0.05". Therefore, the measurement between points III and IV on the upper door opening should not exceed 0.05" in a 7' doorway.

Plumb Dot Accuracy

A free measuring distance of approximately 16.5' between floor and ceiling on a firm surface is required for this check.

  1. Place the tool within 1' of the floor.
  2. Turn the tool to ON and to Vertical Plumb Line Mode or Perpendicular Level, Plumb Points, and Horizontal Points mode.
  3. Set tool on ground and mark the center of the plumb point on the ceiling (point I). Also, mark the center of the plumb point on the floor (point II).

Diagram Description: A vertical space between floor and ceiling is shown. Points I (ceiling) and II (floor) are marked by the laser's plumb points. The distance is indicated as 16.5'.

  1. Rotate the tool 180°. Align the center point of the laser beam directly onto the floor point II.
  2. Mark the center of the top plumb point on the reference line on the ceiling (point III).
  3. The distance between points I and III on the ceiling is the deviation (d) of the tool. This distance should not exceed 1/8" (max.) at 33'.

Accuracy Calculation Example: For the measuring distance of 2 x 16.5' = 33', the maximum allowable deviation (d) is: 33' x ±1/8" ÷ 33' = ±1/8".

Squaring Procedure

1. Mark a reference (point x) on the floor that is equidistant from each wall in the center of a room. Turn ON the laser and switch to the "Unlocked" position. Ensure that laser is in Perpendicular Level, Plumb Points, and Horizontal Points mode (all lasers ON). Using the down plumb point, align the laser directly over the center of point (x) on the floor. With the laser in place, mark point (I) at the intersection of the lines directly in front of the laser on wall A. Without moving the laser, also mark the center of the right Horizontal point (II) on wall B.

Diagram Description: A room corner is shown with walls A and B. A reference point 'x' is marked on the floor. The laser is positioned over 'x', projecting lines onto walls A (point I) and B (point II).

2. Rotate the laser 90 degrees clockwise around plumb point (x) and align the left Horizontal dot with the previously marked point A. With the laser in position, mark point (III) on wall B at the intersection of the perpendicular lines directly in front of the laser. Without moving the laser, mark point (IV) on wall C using the right horizontal point. The deviation (d) between points II & III should be no more than 1/8" at 33'.

Diagram Description: The laser is rotated. A new point (III) is marked on wall B, and point (IV) on wall C. Distances of 33' are indicated.

3. Lastly, rotate the laser 180° clockwise around plumb point (x) so that the right horizontal point is aligned with the previously marked point I. Without moving the laser, using the left horizontal point mark (V) on wall C. The deviation (d) between points IV & V should be no more than 1/8" at 33'.

Diagram Description: The laser is rotated again. A new point (V) is marked on wall C. Distances of 33' are indicated.

Maintenance

⚠️ To reduce the risk of injury, always remove the battery before performing any maintenance. Never disassemble the tool.

Maintain Laser Level

Maintain tools. If damaged, have the tool repaired before use. Accidents may be caused by poorly maintained tools.

⚠️ To reduce the risk of personal injury and damage, never immerse your tool in liquid or allow a liquid to flow inside them.

Cleaning

Clean dust and debris from any vents. Keep tool clean, dry and free of oil or grease. Use only mild soap and a damp cloth to clean, since certain cleaning agents and solvents are harmful to plastics and other insulated parts. Some of these include gasoline, turpentine, lacquer thinner, paint thinner, chlorinated cleaning solvents, ammonia and household detergents containing ammonia. Never use flammable or combustible solvents around tools.

Cleaning the Lenses

Blow off loose particles with clean compressed air. Carefully wipe the surface with a cotton swab moistened with water.

Repairs

For repairs, return the tool, battery pack and charger to the nearest authorized service center.

Accessories

⚠️ Use only recommended accessories. Others may be hazardous.

For a complete listing of accessories, go online to www.milwaukeetool.com or contact a distributor.

Service - United States

1-800-SAWDUST (1.800.729.3878)

Monday-Friday, 7:00 AM - 6:30 PM CST

or visit www.milwaukeetool.com

Contact Corporate After Sales Service Technical Support with technical, service/repair, or warranty questions.

Email: metproductsupport@milwaukeetool.com

Become a Heavy Duty Club Member at www.milwaukeetool.com to receive important notifications regarding your tool purchases.

Service - Canada

Milwaukee Tool (Canada) Ltd

1.800.268.4015

Monday-Friday, 7:00 AM - 4:30 PM CST

or visit www.milwaukeetool.ca

Models: 3624-20 M12 12 Volt Lithium Ion Cordless Green Cross Line and 4 Points Laser, 3624-20 M12, 12 Volt Lithium Ion Cordless Green Cross Line and 4 Points Laser, Cordless Green Cross Line and 4 Points Laser, Green Cross Line and 4 Points Laser, Line and 4 Points Laser

File Info : application/pdf, 7 Pages, 2.81MB

PDF preview unavailable. Download the PDF instead.

919256 KKMsEo

References

PDFium PDFium

Related Documents

Preview Milwaukee M12 3PL Laser Level User Manual
User manual for the Milwaukee M12 3PL laser level, providing comprehensive safety instructions, technical specifications, operating procedures, and maintenance guidelines for professional use.
Preview Milwaukee M12 3PL Laser Level Quick Start Guide
This guide provides an overview of the Milwaukee M12 3PL laser level, including its features, operation modes, and battery information. It details how to use the self-leveling and manual modes, change the battery, and interpret the LED indicators.
Preview Milwaukee M12 Cordless Rotary Tool Operator's Manual
Operator's manual for the Milwaukee M12 Cordless Rotary Tool (Model 2460-20), providing comprehensive safety warnings, operating instructions, assembly procedures, maintenance guidelines, specifications, and warranty information.
Preview Milwaukee RD1200 Rotary Detector 1,220M Operator's Manual
Comprehensive operator's manual for the Milwaukee RD1200 Rotary Detector 1,220M. Includes detailed safety warnings, assembly instructions, operation guide, specifications, troubleshooting tips, and maintenance procedures for accurate laser detection.
Preview Milwaukee M12 FUEL 1/4" Hex Impact Driver Operator's Manual
Operator's manual for the Milwaukee M12 FUEL 1/4" Hex Impact Driver (Model M12 FID2), covering safety warnings, operation, assembly, maintenance, and specifications.
Preview Milwaukee 48-35-1211: 165' Laser Line Detector - Operator's Manual
This operator's manual provides essential safety, operating, and maintenance instructions for the Milwaukee 165' Laser Line Detector (Model 48-35-1211). Learn how to use the laser detector effectively and safely for various construction and measurement tasks.
Preview Milwaukee M12 FUEL ProPEX Expander Operator's Manual
Comprehensive operator's manual for the Milwaukee M12 FUEL ProPEX Expander (Model 2532-20), covering safety warnings, operation, maintenance, troubleshooting, specifications, and assembly instructions.
Preview Milwaukee M12 FUEL Straight Die Grinder (M12 FDGS) Operator's Manual
Comprehensive operator's manual for the Milwaukee M12 FUEL Straight Die Grinder (Model M12 FDGS), covering safety warnings, operation, maintenance, specifications, and assembly instructions.