Product Function Manual
Smart Home HJH173 Ble
Remote Control Button Map
The remote control features the following buttons:
- UBL: Bedside Lamp On/Off
- LOCK: Key Lock
- ZGRAV: Zero Gravity Position
- HEAD: Head Up/Down adjustment
- FOOT: Foot Up/Down adjustment
- SNORE: Snore Position
- M1: Memory Position 1
- PILLOW: Pillow Up/Down adjustment
- LUMBAR: Lumbar Up/Down adjustment
- M2: Memory Position 2
- FLAT: One-key Reset to Flat Position
- HEAD MASSAGE: Head Massager Control
- FOOT MASSAGE: Foot Massager Control
- + / - : Strength Adjustment
- Mode Switch: Controls massager wave modes (Constant, Low Speed Wave, Medium Speed Wave, High Speed Wave)
Note: Specific button numbering from diagrams is omitted for clarity, focusing on function labels.
Remote Control Function Description
Button Label | Features |
---|---|
1 (UBL) | Bedside lamp on/off (always on). |
2 (Flashlight) | Flashlight on/off (default 15s). Reuse Function: Press and hold the flashlight button for 5 seconds; the backlight will flash, entering memory mode. Release the flashlight, then press M1/M2/TV/ZG/SNORE within 2 seconds. The control box will beep, memorizing the current position (back leg motor, light band, massager mode/intensity, etc.). If M1 or M2 is not pressed within 2 seconds, the edit memory position mode exits. Multiplexing Function: Press and hold FLAT + flashlight for 3s simultaneously; the backlight flashes 3 times, entering continuous pressing mode. |
(Implicit Button for Continuous Pressing) | At this time, keys at all positions enter continuous pressing mode. Releasing the key stops the motor. |
(Implicit Button for One-Button Release) | Reuse Function: Press and hold flashlight + lock keys simultaneously for about 3s; the backlight flashes once, entering one-button release mode. All keys enter one-button release mode, and memory positions can be reset to factory default settings simultaneously. |
3 (LOCK) | Key Lock Function: Press and hold this key for 5 seconds; the backlight flashes 3 times, locking the remote control keys. Pressing any other key will cause the remote control backlight to flash 3 times, and the remote control key will be unavailable. Press and hold this button for 5 seconds again; the backlight flashes 3 times, unlocking the remote control button, making it usable again. |
4 (HEAD UP) | The head motor extends and stops when released. |
5 (HEAD DOWN) | The head motor retracts and stops when released. |
6 (FOOT UP) | The foot motor extends and stops when released. |
7 (FOOT DOWN) | The foot motor retracts and stops when released. |
8 (ZG) | The motor runs to ZG (Zero Gravity) position with one key (with initial value). Multiplexing Function: Press and hold the flashlight for about 5s; the backlight flashes. Press ZG within 2s; the buzzer rings 3 times, recording the current motor position and the status of the massager and light bar to ZG. (Power off does not clear). |
9 (SNORE) | The motor runs to the SNORE position with one key (with initial value). When the key is released, it will be timed for 15 minutes, and then the massager will be flattened and closed. Press any key that can operate the motor to exit the timing. No timing for continuous pressing mode. Multiplexing Function: Press and hold the flashlight for about 5s; the backlight flashes. Press SNORE within 2s; the buzzer rings 3 times, recording the current motor position and the status of the massager and light bar to SNORE. (Power off does not clear). |
10 (PILLOW UP) | "PILLOW" motor extends, releases and stops. |
11 (PILLOW DOWN) | "PILLOW" motor descends, releases and stops. |
12 (LUMBAR UP) | "LUMBAR" motor extends, releases and stops. |
13 (LUMBAR DOWN) | "LUMBAR" motor descends, releases and stops. |
14 (M1/MEN) | The motor runs to M1 or MEN position with one key (with initial value). Multiplexing Function: Press and hold the flashlight for about 5s; the backlight flashes. Press M1 or MEN within 2s; the buzzer sounds 3 times, recording the current motor position and the status of the massager and light bar to M1 or MEN. (Power off does not clear). |
15 (M2) | The motor runs to M2 position with one key (with initial value). Multiplexing Function: Press and hold the flashlight for about 5s; the backlight flashes. Press M2 within 2s; the buzzer rings 3 times, recording the current motor position and the status of the massager and light bar to M2. (Power off does not clear). |
16 (FLAT) | Head Massager: If the head massager is not turned on, press the key to turn it on. The massager defaults to the state when it was last turned off. If the massager is turned on, press the key to increase the strength of the head massager. Strength levels are 3 (low > medium > high). Default time is 15 minutes; it continues to run at maximum strength. Reduce Head Massager Strength: Press the button for 3 strengths. Press the massager again to close when minimum strength is reached. Foot Massager: If the foot massager is not turned on, press the key to turn it on. The massager defaults to the state when it was last turned off. If the massager is turned on, press the key to increase the strength of the foot massager. Strength levels are 3 (low > medium > high). Default time is 15 minutes; it continues to run at maximum strength. Reduce Foot Massager Strength: Reduce strength by 3 times. Press the massager again to close when minimum strength is reached. |
20 (FLAT Reset) | FLAT one-key reset: all motors retract to the minimum travel position (power-on does not reset). (If the massager is on, turn off the massager; do not turn off the bedside lamp). |
21 (Mode Switch) | Mode Switch: CONSTANT - LOW SPEED WAVE - MEDIUM SPEED WAVE - HIGH SPEED WAVE. Press and hold for 5s to turn off the massager. The intensity remains unchanged after mode switching. |
Code Checking Method
Single control box/single remote control: Continue to press the head up and foot down buttons until the backlight flashes to clear the remote control code information. Power on the control box again; the control box will be in the code checking state within 60 seconds. Press the head down + foot up button of the remote control continuously; the buzzer will sound, indicating successful code checking. When any key on the successfully checked remote control is pressed, the control box will exit the code checking state.
Precautions
To protect the reliability and safety of the motor and control box, do not switch the buttons frequently.
Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.