Campbell Scientific CELL220

4G LTE CAT1 Cellular Module for Australia

Simple to Use, Easy to Maintain

Low-power option for use in Australia

Overview

Campbell Scientific's external cellular modules, including the CELL200 series, enable system integrators, OEMs, and large end users to avoid costly maintenance visits to remote devices. The CELL220 is a 4G LTE cellular device providing serial or CS I/O connectivity to various cellular networks, including Verizon, AT&T, T-Mobile USA, Rogers, Bell, Telstra, and Telus. Network and carrier selection is determined by the model and inserted SIM card. The CELL220 offers very low power consumption: 14 mA at idle, 39 mA when active, and 300 µA in low power mode. It is compatible with standard data SIMs and does not require additional services like VPNs or special APNs for remote access, thanks to the complimentary Konect Pakbus Router service. Currently, the CELL220 is an IP-only modem; SMS functionality will be added in a future operating system release and will be field-upgradeable. Cellular network availability is required for field firmware updates.

The CELL220 is part of the CELL200 series, which includes:

  • CELL205 for use with AT&T
  • CELL210 for use with Verizon
  • CELL215 for use in EMEA countries
  • CELL220 for use in Australia
  • CELL225 for use in Japan

Benefits and Features

  • Includes everything needed for use with a Campbell Scientific data logger or smart sensor.
  • Low power consumption, ideal for solar-powered sites.
  • Easy integration, setup, and installation.
  • No moving parts and low maintenance.
  • Fully integrated functionality with data loggers like CR300, CR1000X, CR6, and GRANITE series.
  • Compatible with older data loggers in PPP mode (CR800, CR1000, CR3000).
  • Compatible with Edlog-era data loggers in serial server mode.
  • 4G LTE networking (including LTE Band 28) with 3G fallback.

Detailed Description

The CELL220 is an industrial 4G LTE cellular module requiring a micro-SIM 3FF card and a 12 or 24 Vdc power source. It features an RS-232 serial port and a CS I/O port, usable for serial server, serial client, and PPP host services, commonly connecting to a data logger's RS-232 or CS I/O port. Two antenna connectors are provided for primary and diversity antennas, though operation is possible with only the primary antenna connected.

Internet Connectivity

The CELL220 provides Internet connectivity to any Campbell Scientific data logger within a compatible cellular network's range. This enables remote connections to Campbell Scientific software on PCs, mobile devices, and the cloud, and supports protocols such as FTP, DNP3, email, and web (HTTP).

Device Intelligence

The CELL220 offers highly reliable connectivity and remote device management, independent of the connected device. It includes embedded services like IP serial server and client.

Selecting a Data Service

A SIM card and data plan are necessary for telemetry systems. Telstra generally offers the best coverage in Australia, particularly in regional areas. Coverage maps are available on Telstra's and Optus' websites. The CELL220 works with standard data plans, and the complimentary Konect Pakbus Router service simplifies setup.

Configuring the CELL220

Configuration is done via a web-based tool hosted by the module, accessible remotely via cellular WAN (in serial server mode) using Internet Explorer or Firefox, or directly via USB. It can also be configured from a data logger using the Device Configuration Utility or CRBasic instructions when in PPP mode.

Data Logger Connection

Data loggers connect via serial or CS I/O cables. The CS I/O connection powers the modem and allows connection of two peripherals to a single data logger, such as a CELL220 and an RF412 radio.

Powering the CELL220

The CELL220 features extremely low power consumption. At 12 Vdc, average consumption is approximately 14 mA when idle. It can be powered on/off using a data logger's SW12V port or the IPNetPower() instruction (for CR1000X, CR300, CR6). Power can be supplied by a BP12 battery, CH150 charging regulator, and SP10 solar panel.

Antennas

Campbell Scientific offers two antenna options: an enclosure-mounted MIMO antenna (ANT-RV50(X)/CELL220-ENC-0.6M recommended) and an external whip antenna. For discrete antenna needs, a pair of ANT 6.5DB-4GX-N antennas can be used. External antennas may require surge suppression kits; contact Campbell Scientific for details.

SMS Functionality (coming soon)

The CELL220 will initially be released without SMS support. This feature will be added in a future operating system release and will be field-upgradeable. Cellular service and mobile data are required for over-the-air operating system updates.

Sample Programs

  • View a sample program for using terminal commands with CELL2XX modules.
  • View a sample program for using the SetSettings functionality with CR300, CR310, CR6, and CR1000X dataloggers.

Specifications

FeatureDetails
CertificationsIC (Industry Canada) 10224A-201611EC21A
Host InterfaceCS I/O communications port, DB9 male
RS-232 serial port, DB9 female
USB version 2.0 with micro-B connector
RF Connectors2 SMA antenna connectors (primary and diversity)
SIM Interface3FF (6 position/contacts)
Supports SIMs that require 1.8 or 3 Vdc.
Dimensions13.46 x 8.1 x 2.86 cm (5.3 x 3.19 x 1.13 in.)
Weight215.5 g (7.6 oz)
Cellular WAN Network Technology4G LTE CAT-1 (with automatic fallback to 3G)
Carrier ApprovalTelstra
LTE Bands2100(B1), 1800(B3), 850(B5), 2600(B7), 700(B28)
WCDMA Bands1900(B1), 850(B5)
Data Speeds LTEMax 5 Mbps (upload)
Data Speeds WCDMAMax 10 Mbps (download)
Max 384 Kbps (upload)
Data Speeds GSM EDGEMax 384 Kbps (download)
Max 296 Kbps (download)
Max 236.8 Kbps (upload)
Data Speeds GSM GPRSMax 85.6 Kbps (upload)
Max 107 Kbps (download)
Data Speeds RS-232 or CS I/O9600 bps to 460.8 kps
Power Consumption: Low Power Mode300 µA
Power Consumption: Idle14 mA
Power Consumption: Active39 mA
Radio Output Power24 dBm on UMTS
23 dBm on LTE
Radio Sensitivity Range-99.5 to 110.5 dBm (10 M)

For comprehensive details, visit: www.campbellsci.com.au/cell220

PDF preview unavailable. Download the PDF instead.

b cell220 RealObjects PDFreactor(R) 10.1.10722.3, Serial No: 4019, Licensed for: Campbell Scientific, Inc. RealObjects PDFreactor(R) 10.1.10722.3, Serial No: 4019, Licensed for: Campbell Scientific, Inc.

Related Documents

Preview CR9000X Measurement and Control System Instruction Manual
The CR9000X Measurement and Control System Instruction Manual from Campbell Scientific provides detailed guidance on installing, operating, and programming this robust data acquisition system. It covers system components, measurement modules, data handling, and software tools like RTDAQ and LoggerNet, essential for scientific and industrial applications.
Preview Campbell Scientific CDM-A100 Series: Instruction Manual for CDM-A108 and CDM-A116
This instruction manual details the Campbell Scientific CDM-A100 Series analog input modules, specifically the CDM-A108 (8-channel) and CDM-A116 (16-channel) models. It covers essential information on product specifications, installation procedures, operational guidance, and maintenance requirements for these data acquisition devices, including features like analog input, excitation, and communication interfaces.
Preview CR6 Measurement and Control Datalogger Product Manual
Comprehensive product manual for the Campbell Scientific CR6 Measurement and Control Datalogger, detailing its features, setup, operation, measurements, communications protocols, maintenance, and specifications.
Preview Raven X Airlink Cellular Modem Instruction Manual
Instruction manual for the Raven X Airlink Cellular Modem (V4221-T) by Campbell Scientific, detailing its specifications, configuration, activation, and connection procedures for data logging applications.
Preview Campbell Scientific IR100/IR120 Infra-red Remote Temperature Sensor User Manual
This manual provides detailed information on the Campbell Scientific IR100 and IR120 Infra-red Remote Temperature Sensors. It covers specifications, installation, principles of measurement, programming examples for data loggers, and maintenance procedures.
Preview CSI Toro Toolbox Instruction Manual - Campbell Scientific
Comprehensive instruction manual for the CSI Toro Toolbox by Campbell Scientific, covering setup, operation, troubleshooting, and maintenance of the data logger system.
Preview BDR301 Basic Data Recorder Operator's Manual | Campbell Scientific
Operator's Manual for the Campbell Scientific BDR301 Basic Data Recorder. Covers operation, programming, maintenance, commands, and specifications for this programmable datalogger/controller.
Preview Campbell Scientific SMP10 Pyranometer Manual: Solar Radiation Measurement
Comprehensive guide to the Campbell Scientific SMP10 Pyranometer, covering specifications, installation, wiring, Modbus and analog programming, maintenance, troubleshooting, and safety. Ideal for solar resource assessment and environmental monitoring.