ABB M251021CR / M251022CR Display Module with Card Reader
Operating Instructions
Safety Information
⚠️ WARNING
Dangerous currents flow through the body when coming into direct or indirect contact with live components. This can result in electric shock, burns or even death.
- Disconnect the mains power supply prior to installation and/or disassembly!
- Permit work on the 110-240 V supply system to be performed only by specialist staff.
Addressing
The diagram displays the module with several numbered connectors and switches for configuration. Key components include:
- 1. Addressing Switch (Outdoor Station): A rotary switch used to set the address for the outdoor station, with options from 1 to 9.
- 2. Addressing Switch (Indoor Station - Default Outdoor): A DIP switch on the left side, used to set the address of the default outdoor station, with options from 1 to 9.
- 3. Addressing Switches (Indoor Station): Three DIP switches that collectively set the specific address for the indoor station, defining hundreds, tens, and units digits (e.g., 001).
- 4. Wiegand Output Connector: A connector for Wiegand data output.
- 5. USB Connector: Used for connecting to a PC to download or upload configuration settings.
- 6. Next Module Connector: A connector for linking to the subsequent module in a system.
For outdoor stations: Use switch 1 to set the address (1-9).
For indoor stations: Use the left switch 2 to set the address of the default outdoor station (1-9). Then, use the remaining three switches 3 to set the address (hundreds, tens, and units digits, e.g., 001) of the indoor station.
Settings / Parameters
Setting | Description |
---|---|
1. "Program" button | "Program" button |
2. Connector for previous module | Connector for previous module |
3. Connector for device software update | Connector for device software update |
4. Connector for wiegand output | Connector for wiegand output |
5. USB connector for the connection to the PC: download/upload the configuration | USB connector for the connection to the PC: download/upload the configuration |
6. Connector for next module | Connector for next module |
Operation / Functionality
Operation | Description |
---|---|
1. LCD display | LCD display |
2. Support ID or IC card. | Swipe the registered card to release the door lock. The card can be programmed from the module itself, or using a PC to download the programming file. (M251021CR is with ID card reader, while M251022CR is with IC card reader.) |
3. Support Wiegand output. | Default wiegand format is 26 bits, also it can be extended to 34 bits. |
Related Documents
![]() |
Voltronics Repairs List: ABB and Other Industrial Components A comprehensive list of repairable industrial components, primarily focusing on ABB products including inverters, servo drives, control units, and PCBs, alongside items from other manufacturers like Allen Bradley, Alfa Laval, and AEG. |
![]() |
ABB Welcome IP Display Module: Specifications and Overview Comprehensive details on the ABB Welcome IP Display Module, covering its connections, technical data, and compliance with EU and FCC regulations. Includes model numbers 51381CR and 51382CR. |
![]() |
ABB S500 IO Modules: Integration Guide with Smart Communication Card and Node-RED This application note from ABB guides users through the integration of S500 IO modules with the Smart Communication Card (SCC). It provides detailed instructions on establishing connections via Modbus TCP and utilizing Node-RED for implementing sophisticated control logic and enabling seamless cloud-based monitoring. |
![]() |
ACS850 Drive Modules Quick Installation Guide - ABB This guide provides essential information for the mechanical and electrical installation of ABB ACS850-04 drive modules (0.37 to 45 kW), covering safety, mounting, and connection procedures. |
![]() |
ABB OneTouch 7 Technical Specifications and Features Detailed technical specifications, terminal descriptions, and control elements for the ABB OneTouch 7 system, including multilingual information. |
![]() |
DELTAplus/DELTAmax Meter User Manual - ABB Comprehensive user manual for ABB's DELTAplus and DELTAmax electronic electricity meters, covering features, installation, technical specifications, and communication protocols. |
![]() |
ABB IP Touch Lite 7 H8249-1: Technical Specifications and Compliance Discover the technical specifications and EU declaration of conformity for the ABB IP Touch Lite 7 H8249-1. This document provides details on its control elements, terminal descriptions, and technical data including voltage, resolution, and wireless transmission standards. |
![]() |
ABB-Welcome Door Entry System Manual - Overview and Features A comprehensive overview of the ABB-Welcome door entry system, detailing its 2-wire technology, modular design, application flexibility, and extensive product range for residential and commercial installations. The manual covers planning, installation, operation, and technical specifications. |