Truper 102141 PROVO-2 Non-contact Voltage Tester
Model: 102141 PROVO-2
Warranty Policy
Duration: 1 year.
Coverage: Parts, components, and workmanship against manufacturing or operating defects. Excludes defects from use under abnormal conditions, improper operation per instructions, or unauthorized repair/alteration by personnel not authorized by Truper®.
To validate the warranty, present the product along with the stamped policy, invoice, or receipt at the point of purchase. You may also visit the service center at Corregidora 22, Centro, Cuauhtémoc, CDMX, 06060, where parts, components, consumables, and accessories can be purchased.
Transportation costs for warranty fulfillment are covered by Truper's service network.
Customer Service Phone: 800-018-7873.
Origin: Made in China. Imported by Truper, S.A. de C.V., Parque Industrial 1, Parque Industrial Jilotepec, Jilotepec, Edo. de Méx. C.P. 54257.
Contact Phone: 761 782 9100.
Warranty Service Locations
Baja California | Tijuana: AV. LA ENCANTADA, LOTE #5, PARQUE INDUSTRIAL EL FLORIDO II, C.P 22244, TIJUANA, B.C. TEL.: 66 4969 5100
Chihuahua | Chihuahua: AV. SILVESTRE TERRAZAS #128-11, PARQUE INDUSTRIAL BAFAR, CARRETERA MÉXICO CUAUHTÉMOC, C.P. 31415, CHIHUAHUA, CHIH. TEL. 61 4434 0052
Coahuila | Torreón: CALLE METAL MECÁNICA #280, PARQUE INDUSTRIAL ORIENTE, C.P. 27278, TORREÓN, COAH. TEL.: 87 1209 6823
Estado de México | Centro Jilotepec: PARQUE INDUSTRIAL 1, PARQUE INDUSTRIAL JILOTEPEC, JILOTEPEC, EDO. DE MÉX. C.P. 54257. TEL: 76 1782 9101 EXT. 5728 Y 5102
Jalisco | Guadalajara: AV. ADOLFO B. HORN # 6800, COL: SANTA CRUZ DEL VALLE, C.P.: 45655, TLAJOMULCO DE ZUÑIGA, JAL. TEL.: 33 3606 5285 AL 90
Nuevo León | Monterrey: CARRETERA LAREDO #300, 1B MONTERREY PARKS, COLONIA PUERTA DE ANÁHUAC, C. P. 66052, ESCOBEDO, NUEVO LEÓN, N.L. TEL.: 81 8352 8791 / 81 8352 8790
Puebla | Puebla: AV PERIFERICO #2-A, SAN LORENZO ALMECATLA, C.P. 72710, CUAUTLACINGO, PUE. TEL.: 22 2282 8282 / 84 / 85 / 86
Sinaloa | Culiacán: AV. JESÚS KUMATE SUR #4301, COL. HACIENDA DE LA MORA, C.P. 80143, CULIACÁN, SIN. TEL.: 66 7173 9139 / 66 7173 8400
Tabasco | Villahermosa: CALLE HELIO LOTES 1, 2 Y 3 MZ. #1, COL. INDUSTRIAL, 2A ETAPA, C.P. 86010, VILLAHERMOSA, TAB. TEL.: 99 3353 7244
Yucatán | Mérida: CALLE 33 #600 Y 602, LOCALIDAD ITZINCAB Y MULSAY, MPIO. UMÁN, C.P. 97390, MÉRIDA, YUC. TEL.: 99 9912 2451
Product Overview
The Truper 102141 PROVO-2 is a non-contact voltage tester designed to detect live electrical circuits without direct contact.
Important Safety Information
⚠️ IMPORTANT NOTE: This product must not be exposed to dripping or splashing by liquids.
⚠️ ATTENTION: READ THESE OPERATING INSTRUCTIONS AND FOLLOW ALL SAFETY AND OPERATING INSTRUCTIONS BEFORE USE.
Battery Assembly
To assemble the battery:
- Open the cover by pressing the button on the top of the clip and slide the top and bottom sections of the tester apart.
- Remove old batteries and insert two new AAA 1.5V batteries, ensuring correct polarity as shown in the diagram.
- Engage the two housing sections and slide them together until the clip clicks into place.
Description of Diagram: The process involves pressing a button on the clip to open the tester, separating it into two parts. New batteries are inserted, observing the '+' and '-' terminals. The two parts are then rejoined until they lock.
Operating Instructions
Manual Operation
- Test Run: Perform a test by pressing the power button and bringing the tip close to an energized contact. The LED will illuminate and a buzzer will sound.
- Power/LED Button:
- Press the LED button once to turn on the tester. A short beep will sound, and the green LED will light up.
- Press again to turn on the lamp.
- Press once more to turn off the lamp.
- Press and hold for one second to turn off the tester.
- Live Detection: Bring the probe close to live parts; the red LED will turn on.
- Alerts: When the green LED turns off, an alert will sound. A higher frequency of alerts indicates a stronger electric field, allowing the user to distinguish between null and live lines via sound and light alarms.
- Automatic Shutdown: The tester automatically shuts down after 2 minutes of inactivity to save power.
- Low Battery Indicator: When the battery is low, the green LED will not illuminate, the detector will not operate, and the buzzer will emit a faint sound.
Specifications
- Operating Voltage: 3 V d.c. (Requires 2 x AAA Carbon-Zinc 1.5 V d.c. batteries, included)
- Ambient Temperature and Humidity: 10 °C - 50 °C; < 95% relative humidity
- Storage Temperature: -10 °C - 50 °C
- Sensing Range: 90 V~ - 1000 V~ (Standby current after power off ≤ 1 µA)
Functions
- Evaluate neutral and live lines on a.c.
- Detect magnetic field.
- Illumination function (LED lamp).
- Automatic shutdown in 2 minutes.
- Sound and light alarm.
Warnings
- Never use in circuits with voltages higher than 1000 V.
- Test voltage range: 90 V~ - 1000 V~.
Safety Precautions
This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or by inexperienced persons, unless they are supervised by a responsible adult or have received prior instruction in its use.
⚠️ CAUTION: Children should be supervised to ensure they do not play with the appliance. Close supervision is necessary when disabled persons or children use or are near any electrical appliance.