APC Performance Surge Protector

Models: PM8, PMF83VT

Safety Precautions

  • Do not install this device during a lightning storm.
  • For indoor use only.
  • Do not install the surge protector in a hot or excessively moist location.
  • Do not use with aquarium equipment.

Installation

Follow these steps to install your surge protector:

  1. Plug the surge protector into a grounded outlet only.
  2. Plug the power cord from your electrical equipment into the surge protector outlets [outlet_group_symbol]. Verify the device to be protected operates correctly before plugging it into the surge protector.
  3. For PMF83VT series models, connect the supplied modular telephone cord between the telephone wall outlet and the surge protector jack [telephone_jack_symbol] marked . Connect another modular telephone cord between the surge protector jack [telephone_jack_symbol] marked and the telephone, modem, or fax machine.
  4. All PMF83VT series models provide coaxial connectors. Connect the supplied coaxial cable from the cable source to the connector [coaxial_connector_symbol] marked . Connect another coaxial cable from the connector [coaxial_connector_symbol] marked to the equipment to be protected (cable TV box, VCR, TV, cable modem).
  5. Press the Power switch [power_switch_symbol] to the "I" position.

Indicators and Controls

  • Circuit Breaker [circuit_breaker_symbol]: When an output overload condition occurs, power automatically turns off, disconnecting all equipment. Unplug connected equipment, then press the circuit breaker to reset the surge protector.
  • Surge Protection Indicator [surge_protection_indicator_symbol]: When the unit is plugged in and turned on, the green indicator illuminates to show the surge protector is capable of protecting equipment from harmful electrical surges. If the indicator does not illuminate, the unit is damaged and no longer protects equipment; return it according to Schneider Electric IT (SEIT) Technical Support instructions.
  • Ground OK Indicator [ground_ok_indicator_symbol]: When the surge protector is plugged in and power is turned on, the green indicator illuminates to show that the power source outlet is properly grounded. If the indicator does not illuminate, there is a problem with the building wiring; consult a qualified electrician.
  • Overload Indicator [overload_indicator_symbol]: If this indicator illuminates, disconnect devices until the indicator extinguishes.
  • Cord Management Guide [cord_management_guide_symbol]: Keeps power cords connected to the unit neat and organized. It can also be wall mounted [wall_mount_symbol] with the surge protector.

Specifications

Feature PM8 PMF83VT
Input Voltage 250V 250V
Secondary Protection N/A Coaxial 1 in /1 out, Telephone 1 in /1 out
Input Frequency 50Hz + 5Hz 50Hz + 5Hz
Maximum Line Current per phase 10A 10A
Cord Length 2 meters (6.56 ft.) 3 meters (9.84 ft.)
Joule Rating 2754 Joules 2754 Joules
EMI/RFI Noise rejection < 60db < 60db
Dimensions (WxDxH) 110.3 x 326.5 x 61.7 mm (4.34 x 12.85 x 2.43 in.) 110.3 x 326.5 x 61.7 mm (4.34 x 12.85 x 2.43 in.)

Warranty and Protection Policies

Limited Warranty

SEIT warrants its products to be free from defects in materials and workmanship under normal use and service by the original owner for the lifetime of the product (in Germany, the period is 20 years from the purchase date). For units purchased and/or used in countries not belonging to the European Community, the warranty period is 2-5 years from the date of purchase. SEIT's obligation is limited to repairing or replacing defective products at its sole option. To obtain warranty service, a Returned Material Authorization (RMA) number from SEIT or a SEIT Service Center is required. The product must be shipped prepaid with a brief problem description and proof of purchase. More details are available at www.apc.com.

Equipment Protection Policy

This policy covers damage to connected electronic equipment from power line transients (spikes and surges) when properly connected to an APC by Schneider Electric product. It is valid in EU member states, Norway, Switzerland, Iceland, and Liechtenstein. For coverage, the connected equipment must have a CE mark, and the installation must comply with all applicable electrical and safety codes. Claims must be made within 10 days of alleged damage. SEIT reserves the right to inspect the damaged equipment. Specific dollar and period limits apply, details available in the full policy document.

Data Recovery Policy

If data is lost from the hard drive in the protected computer due to a malfunction of a properly connected APC by Schneider Electric product, SEIT will provide data recovery services from Ontrack® data recovery labs, at its sole discretion. Recovery is not guaranteed. This policy applies to physical hard drives within protected computing equipment, excluding external storage devices. SEIT reserves the right to inspect the damaged equipment.

Models: APC PM8-GR Performance Surge Protector, APC PM8-GR, Performance Surge Protector, Surge Protector, Protector

File Info : application/pdf, 7 Pages, 2.08MB

PDF preview unavailable. Download the PDF instead.

SCHNEIDER ELECTRIC APC PM8-GR (01)

References

Related Documents

Preview APC SurgeArrest 6 + USB: Specifications and Features
Comprehensive details on the APC SurgeArrest 6 + USB power strip, including its surge protection capabilities, number of sockets, connector types, and physical specifications.
Preview APC PM6-GR Performance SurgeArrest 6-Outlet Surge Protector - Technical Specifications
Detailed technical specifications for the APC PM6-GR Performance SurgeArrest 6-outlet surge protector, including input/output details, physical characteristics, surge protection, and environmental compliance.
Preview APC Back-UPS BX Series User Manual: Installation, Operation, and Troubleshooting
Comprehensive user manual for APC Back-UPS BX Series (500VA to 2200VA) from Schneider Electric, covering safety instructions, product description, operational features, installation, troubleshooting, service, and warranty information.
Preview APC Back-UPS BX Series User Manual: Power & Surge Protection for Computers
Comprehensive user manual for APC Back-UPS BX Series (500VA to 2200VA). Learn about safety, installation, features, specifications, status indicators, and troubleshooting for reliable power protection.
Preview APC Back-UPS Pro BR1000G Installation and Operation Guide
Comprehensive guide for installing and operating the APC Back-UPS Pro BR1000G, covering setup, features, safety, troubleshooting, and specifications. Learn how to connect equipment, manage power saving, and understand warnings.
Preview APC Back-UPS BR1000G-IN / BR1500G-IN: Installation and Operation Manual
Comprehensive guide for installing and operating the APC Back-UPS BR1000G-IN and BR1500G-IN Uninterruptible Power Supply (UPS), covering specifications, connections, features, troubleshooting, and service.
Preview APC Back-UPS Pro 900: Premium Battery Backup & Surge Protector
Discover the APC Back-UPS Pro 900, offering reliable battery backup, surge protection, and automatic voltage regulation for your electronics. Features LCD display, green outlets, and auto-shutdown software.
Preview APC Back-UPS BE550G/BE700G User Manual: Installation, Operation, and Troubleshooting
Comprehensive user manual for APC Back-UPS BE550G and BE700G models, covering installation, setup, power-saving features, status indicators, troubleshooting, specifications, and support.