IMPORTANT INSTRUCTIONS – RETAIN FOR FUTURE USE
Contents
- Safety Instructions
- Specific Information Regarding R290 Refrigerant Gas
- Symbols Explained
- Specification
- Parts
- Positioning Your Unit
- Operating Instructions
- Continuous Drainage
- Pro Breeze App Setup
- Error Codes
- Cleaning and Storage
- Declaration of Conformity
- PSTI Statement of Compliance
- Recycling and Disposal
Safety Instructions
PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS.
When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
WARNING: TO AVOID THE RISK OF ELECTRICAL SHOCK, FIRE OR INJURY TO PEOPLE, ALWAYS TURN THE APPLIANCE OFF, UNPLUG THE POWER CORD FROM THE ELECTRICAL OUTLET AND EMPTY THE WATER TANK BEFORE HANDLING, CLEANING OR SERVICING THE APPLIANCE.
- Use this dehumidifier only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to person.
- Always unplug the dehumidifier when not in use.
- Keep the dehumidifier out of reach of children and pets.
- Do not leave children alone or unattended in the area where the dehumidifier is in use.
- Children shall not play with the dehumidifier.
- Cleaning and user maintenance shall not be made by children without supervision.
- Dispose of water held by the dehumidifier. This water is not drinkable.
- This dehumidifier can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Never leave the dehumidifier unattended while in use.
- Always turn the dehumidifier off and disconnected from the power supply when not in use.
- Never place anything on top of the dehumidifier.
- Ensure that the mains supply (including voltage, frequency and power) complies with the rating label of the dehumidifier.
- Do not operate the dehumidifier with wet hands.
- Do not use this dehumidifier near water or in the immediate surroundings of a bath, shower or a swimming pool. Never place the dehumidifier where it may fall into a bathtub or other water container.
- Do not allow water or other liquids to run into the interior of the dehumidifier, as this could create a fire and/or electrical hazard.
- This dehumidifier is intended for indoor household use and similar applications. Do not use outdoors.
- The mains cable should not hang down from the surface on which the dehumidifier is placed in order to prevent the dehumidifier from being pulled down.
- To avoid a circuit overload when using this dehumidifier, do not operate another high-wattage dehumidifier on the same electrical circuit.
- Always plug the dehumidifier directly into a wall socket. Avoid using extension leads where possible as they may overheat and cause a risk of fire.
- Do not use this dehumidifier with an external programmer, timer switch or any other device which would switch the dehumidifier on automatically unless this has already been pre-built into the appliance by the manufacturer.
- Do not pull on the power cord. Never move, carry, or hang the dehumidifier by the power cord.
- Do not kink or wrap the power cord and plug around the dehumidifier, as this may cause the insulation to weaken or split, particularly where it enters the dehumidifier.
- Do not operate the dehumidifier with any safety guards removed.
- Do not operate the dehumidifier if there are any signs of damage to the appliance or accessories supplied.
- Do not attempt to repair or adjust any electrical or mechanical elements in the dehumidifier. Doing so may be unsafe and will void your warranty.
- The appliance shall be installed in accordance with national wiring regulations.
- Do not cover the dehumidifier whilst in use.
- When moving the dehumidifier, ensure it is kept in an upright position.
- The dehumidifier must have a minimum 50cm clearance around all sides.
- Avoid placing the power cord in areas where it can become a tripping hazard. Do not place the power cord under carpeting or cover it with rugs, runners or similar.
- Place the dehumidifier on a flat, stable and dry surface and always keep the appliance in an upright position. Operating the appliance in any other position could cause a hazard.
- There may be trace of odour during the first few minutes of initial use. This is normal and will quickly disappear.
- Do not place the dehumidifier against a wall or other appliances.
- Do not cover, obstruct or push objects into the vents and opening of the dehumidifier as this may cause an electric shock, fire or damage the dehumidifier.
- Do not operate the dehumidifier without the filter.
- Do not use mechanical devices to accelerate the appliance's defrosting process.
- Do not place the continuous drainage hose outside when the temperature falls below 1°C.
- Do not use the dehumidifier near petrol, paints, flammable gases, ovens, or other heating sources.
- Do not operate the dehumidifier with the water tank removed.
- Ensure the mains cable is fully extended before use and arrange it so that it is not in contact with any part of the dehumidifier.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person in order to avoid a hazard.
- Never insert fingers or metal objects into the vents and openings of the appliance.
- The unit's circuit board (PCB) is designed with a fuse to provide overcurrent protection. The specifications of the fuse are printed on the circuit board.
Specific Information Regarding R290 Refrigerant Gas
CAUTION: RISK OF FIRE
WARNING: THE DEHUMIDIFIER MUST BE INSTALLED, OPERATED AND STORED IN A ROOM WITH A FLOOR AREA LARGER THAN 4M².
This appliance contains 0.054kg (54g) of R290 refrigerant gas.
R290 is a refrigerant gas that complies with the European directive on the environment.
- Do not puncture any part of the refrigerant circuit.
- Be aware that R290 refrigerant is odourless and does not have the odour normally associated with natural gas and propane tanks.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The dehumidifier must be placed in an area without any continuous sources of ignition such as open flames, gas, or electrical appliances in operation.
- Do not puncture and do not burn the refrigerant circuit.
- If the appliance is installed, operated or stored in a non-ventilated area, the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
- The appliance must be stored in such a way as to prevent mechanical failure.
- Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organisation that ensures competence in handling refrigerants according to a specific evaluation recognised by associations in the industry.
- Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrigerants.
Symbols Explained
- For indoor use only: Indicates the appliance is designed for indoor environments.
- Please read instruction manual and retain for future use: A symbol advising users to read the manual and keep it for future reference.
- UKCA Mark: Equipment complies with the applicable UK safety requirements and regulations.
- CE Mark: Equipment complies with the applicable EU safety requirements and regulations.
Specification
Parameter | Value |
---|---|
Model | PB-D-24-WF-UK |
Voltage | 220-240V~ |
Frequency | 50Hz |
Power | 330W |
Product Dimensions | 305 x 240 x 495mm |
Frequency Band(s) | 2400-2483.5MHz |
Net Weight | 13kg |
Fuse | AC 250V~, 3.15/2A |
Maximum RF Power | 18.2dBm |
Parts
The dehumidifier consists of the following parts:
- Front Panel: Contains the control panel, humidity light, and air outlet.
- Back Shell: Houses internal components.
- Handle: Located on the top and sides for carrying.
- Air Outlet: Where the dehumidified air is expelled.
- Air Inlet with Filter: Located at the rear, where air is drawn into the unit.
- Side Panel: Forms the sides of the unit.
- Control Panel: Features buttons and a display for operation.
- Water Tank: Collects condensed water.
- Casters: Wheels for easy transportation.
- Continuous Drainage Connection: Port for attaching a drain hose.
- Power Cord: Connects the unit to the electrical outlet.
Diagram shows a front view and a rear view of the dehumidifier, labeling the control panel, air outlet, air inlet, handle, water tank, casters, and power cord.
Positioning Your Unit
For optimal performance, follow these guidelines:
- Place the unit in an enclosed space with all doors, windows, and outside openings closed.
- The unit is designed to operate in temperatures between 5°C and 35°C.
- Avoid placing the unit where temperatures may fall below 5°C, as this can cause the coils to freeze and reduce performance.
- Place the unit on a smooth, level, and stable surface strong enough to support it with a full water tank.
- Ensure at least 50cm of space behind the air outlet (top of the unit) and 20cm of space on all other sides for adequate air circulation.
- If placed near an enclosed storage area (e.g., wardrobe, cupboard), ensure sufficient air circulation.
- The unit has four wheels for easy transportation; avoid forcing them over uneven surfaces like carpet.
Diagram illustrates the required clearances: 50cm behind the air outlet and 20cm on all other sides.
Operating Instructions
Quick Start Guide
- Turn Your Unit On: Plug in the unit and press the power button. It will start in auto mode with high speed and a default humidity level of 50%.
- Select A Mode: Press the mode button to cycle through:
- Auto Mode: Lowers humidity to the set level, turns off when reached, and reactivates if humidity rises.
- Laundry Mode: Continuous operation for efficient clothes drying, with high fan speed.
- Night Mode: Similar to Auto Mode, with low fan speed and dimmed lights for a restful night.
- Choose Your Ideal Humidity: In Auto or Night mode, use the humidity button to set your desired humidity level (30-80%). The setting becomes active after 5 seconds. A recommended level for a healthy home is 40%-50%.
Control Panel Functions
The control panel features several buttons and a display:
- Power Button: Turns the unit on or off. In standby, it shows the current room humidity.
- Fan Speed Button: In Auto mode, switches between high and low fan speeds.
- Timer Button: Sets a turn-on or turn-off timer (1-24 hours). The display shows the set hours. Pressing the humidity button cycles through hours. '00' deactivates the timer. Long press enters Wi-Fi pairing mode.
- Humidity Button: Sets the preferred humidity level (30-80%) in Auto or Night mode. Long press displays the room temperature briefly.
- Lock Button: Activates/deactivates child lock by long pressing. The child lock indicator will be on when active.
- Mode Button: Cycles through Auto, Laundry, and Night modes.
- Colour Display: The light indicates ambient humidity: Blue (below 45%), Green (45%-65%), Red (above 65%). Red also indicates error codes.
Diagram shows the control panel with buttons labeled: Power, Lock, Timer, Humidity, Speed, Mode, and indicators for Timer, Auto, Laundry, Night, On/Off, Low Fan Speed, High Fan Speed, Humidity, Target/Current Humidity, Tank Full, and Lock.
Continuous Drainage
To Connect the Drain Hose to the Unit:
- Remove the water tank by pulling on the handles at the rear of the unit.
- Insert one end of the hose into the continuous drainage hole of the unit, ensuring a secure connection.
- Place the other end of the hose into a bucket or a drain.
- Ensure the hose is not bent or blocked.
Note: Gravity will pull water into the drainage area. Ensure the chosen area is not higher than the unit.
Emptying the Water Tank:
- When the water tank is full, the unit will beep 5 times, the 'Tank Full' indicator will turn on, and the display will show 'FL'.
- Press the power button to turn off the unit.
- Slide the water tank out by its handles.
- Empty the water into a sink or drain and clean the inside and outside of the tank.
- Replace the empty tank in the unit.
- Press the power button to resume operation.
- If the 'Water Full' light does not turn off, check that the water tank is correctly in place.
Diagrams show how to remove the water tank and connect a drain hose.
Pro Breeze App Setup
Control your Pro Breeze dehumidifier remotely using the Pro Breeze app. Ensure your Wi-Fi network is set to 2.4GHz for successful pairing.
Pair Your Device in 4 Simple Steps:
- Register: Download the Pro Breeze app from the Google Play or Apple app store and sign in/register.
- Prepare your device: Hold down the timer button for 5 seconds until the Wi-Fi indicator shows on the control panel.
- Add your device: Open the Pro Breeze app, press '+' in the top right corner, and select 'add device'.
- Pair your device: The app will scan for devices. Select your unit and enter your Wi-Fi password.
Your unit is now connected. You can set the unit's mode, target humidity, fan speed, and schedules via the app.
Connecting to Smart Assistants:
- Amazon Echo Set-Up: Ensure Pro Breeze app and Amazon Alexa app are downloaded and paired. Follow steps within the Amazon Alexa app (Skills section) to enable Pro Breeze and link your account. Then, add the appliance as a device in the Alexa app.
- Google Home Set-Up: Ensure Pro Breeze app and Google Home app are downloaded and paired. Follow steps within the Google Home app (Set up device > Have something already set up?) to link your Pro Breeze account. Then, assign the appliance to a room and control it via Google Assistant.
A QR code is provided for downloading the Pro Breeze app.
Error Codes
ERROR CODE | CAUSE | SOLUTION |
---|---|---|
E0 | The wiring has malfunctioned. | Contact Pro Breeze Customer Care by sending an email to help@probreeze.com or via their website www.probreeze.com. |
E1/2 | The humidity sensor is unable to detect the humidity of the environment. | (No specific solution provided in manual, implies contacting support if persistent) |
Cleaning and Storage
WARNING: ALWAYS TURN THE APPLIANCE OFF AND UNPLUG THE POWER CORD FROM THE ELECTRICAL OUTLET BEFORE HANDLING OR CLEANING IT.
CAUTION: DO NOT ALLOW WATER OR OTHER LIQUIDS TO RUN INTO THE INTERIOR OF THE APPLIANCE, AS THIS COULD CREATE A FIRE AND/OR ELECTRICAL HAZARD.
CAUTION: DO NOT USE ANY ABRASIVE CLEANERS OR SOLVENTS, AS THIS CAN DAMAGE THE APPLIANCE.
- Do not attempt to clean the dehumidifier in any way other than that detailed by the manufacturer.
- Never leave water in the water tank when the appliance is not in use.
Cleaning the body of the dehumidifier:
- Turn the dehumidifier off and unplug the power cord.
- Clean the exterior by wiping with a soft, damp cloth.
- Dry the dehumidifier with a soft clean cloth.
Cleaning the air filter:
Note: As the filter gets clogged, the dehumidifying capacity is lowered. Clean the rear air filter every 2 weeks.
- Remove the air filter by gently pulling on the handle at the top of the filter cover.
- To extend the filter's lifespan, use a vacuum cleaner with a brush attachment to remove dust from the filter surface.
- Return the clean filter to the dehumidifier.
Diagram shows how to remove the air filter by pulling its handle and using a vacuum cleaner.
Cleaning the water tank:
- Remove and empty the water tank as per the 'Emptying the water tank' instructions.
- Remove the water tank's lid by removing the handle and lifting the lid upwards.
- Clean the water tank with warm tap water and mild detergent (e.g., washing up liquid). Do not use boiling water.
- Ensure any scale or deposits inside the tank are removed.
- Wipe all surfaces dry before replacing the water tank's lid handle.
- Return the water tank to the unit.
Storage:
- Store the product in its original or a similar-sized box in a safe, clean, and dry place, away from direct sunlight and out of reach of children.
- Always empty the water tank, and clean and dry the appliance when not in use to prevent mould.
- Empty and clean the dehumidifier before storage. Clean the appliance before the next use post-storage.
Declaration of Conformity
One Retail Group Limited declares that the radio equipment type PB-D-24-WF-UK complies with the Radio Equipment Regulations 2017. The full UK Declaration of Conformity is available at: https://probreeze.com/pages/ec-declaration-of-conformity/
PSTI Statement of Compliance
One Retail Group Limited declares that PB-D-24-WF-UK complies with The Product Security and Telecommunications Infrastructure (Security Requirements for Relevant Connectable Products) Regulations 2023. The full UK PSTI Statement of Compliance is available at: https://probreeze.com/pages/psti-compliance/
Recycling and Disposal
Waste electrical and electronic products (WEEE), batteries, accumulators, and packaging should not be disposed of with general household waste. This is to protect the environment and human well-being, and to conserve natural resources. Most electrical products with a plug, battery, or cable can be recycled.
- Waste Electrical and Electronic Equipment (WEEE): This symbol indicates that Waste Electrical products (WEEE) under Directive 2012/19/EU should not be disposed of with general household waste.
- The Mobius Loop: This symbol indicates that the product or packaging is capable of being recycled.
Contact your local council, household waste disposal service, or the store where you purchased the product for information regarding collection schemes.
Waste electrical products (WEEE) can be sent to One Retail Group for recycling and disposal when purchasing a new product from them, on a like-for-like basis. For more information on how to recycle this product, visit www.probreeze.com.
The end-user is responsible for deleting personal user data from WEEE products before disposal, especially for app-linked products.