Wolf Pro Hoods Internal Blower Installation

For assistance, visit www.subzero-wolf.com or call 800.222.7820.

Contents

  1. Assembly, blower

Mounting Plate (Single Blower Only)

Secure the mounting plate (shipped with the blower) to the blower with four nuts.

Diagram showing mounting plate secured to blower with four nuts.

24" and 27" Pro Wall Hoods

  1. For single blowers only, remove the center section from the hood discharge.

    Diagram illustrating the removal of the center section from the hood discharge.
  2. Install each blower using four nuts per blower.

    Diagram showing blowers being installed with four nuts each.

Pro Island, Pro Chimney, Pro Liner, and Outdoor Hoods

  1. Remove the two nuts from the blower mounting bracket, then remove the bracket from the hood.

    Diagram showing the removal of nuts and bracket from the hood.
  2. For single blowers only, remove the center section from the bracket.

    Diagram illustrating the removal of the center section from the bracket.
  3. Install each blower on the bracket using four nuts per blower.

    Diagram showing blowers installed on the bracket with four nuts each.
  4. Align the tabs on the back of the bracket with the notches at the back of the discharge, then rotate the front of the assembly upward and secure the assembly with the two existing nuts.

    Diagram showing alignment of bracket tabs with discharge notches and securing the assembly.
Models: PW482418, 48-Inch Pro Wall Hood, PW482418 48-Inch Pro Wall Hood

File Info : application/pdf, 1 Pages, 849.95KB

PDF preview unavailable. Download the PDF instead.

frgkpikiqpod

References

AH XSL Formatter V6.3 MR4 for Windows (x64) : 6.3.5.25707 (2016/08/29 16:48JST) (C) 2018 Retailer Web Services LLC, all rights reserved.

Related Documents

Preview WOLF Down Draft 14" Riser Series Blower Motor Data
Technical data for WOLF Down Draft 14" Riser Series blowers, including internal, inline, and remote models, detailing speed, wattage, voltage, and amperage.
Preview Wolf CT Hoods and DD Ventilation: Access & Removal Guide
This guide provides detailed instructions for accessing and removing components from Wolf Pro Series CT Hoods and DD Ventilation units. It covers procedures for filter removal, halogen bulb and light assembly, heat sentry, lamp-holder support, user interface switch mounting bracket, ribbon cable, power outlet, transformer, fuse, internal blower, and control board.
Preview WOLF CT Hoods and DD Ventilation Controls and Operation Guide
This document outlines the controls and operation for WOLF CT Hoods and DD Ventilation systems, including details on lighting, blower speeds, delay features, and the Heat Sentry Mode.
Preview Wolf V-Series Cooktop Hood Component Access and Removal Guide
Detailed guide for accessing and removing components of the Wolf V-Series Cooktop Hood, including filters, LED lights, internal blower, and touch control board. Service and installation information.
Preview Wolf CT Hoods and DD Ventilation Wiring Schematics
Detailed wiring schematics for Wolf CT Hoods and DD Ventilation models, including DD30, DD36, and various INT/EXT blower configurations.
Preview Wolf CT Hoods and DD Ventilation Troubleshooting Guide
Comprehensive troubleshooting guide for Wolf CT Hoods and Downdraft Ventilation systems, providing diagnostic steps, common issues, and repair solutions for service technicians.
Preview Wolf V-Series Cooktop Hoods Troubleshooting Guide
A comprehensive troubleshooting guide for Wolf V-Series Cooktop Hoods, detailing diagnostic tests and resolutions for common issues related to lights, blower motor, and overall functionality. Includes step-by-step procedures for electrical testing.
Preview Wolf CT Hoods and DD Ventilation Technical Data
Technical data for Wolf CT Hoods and DD Ventilation, including supply voltage requirements, temperature parameters, component output levels, and fuse specifications.