WOLF CT Hoods and DD Ventilation

Controls / Operation

ELECTRONIC CONTROL FOR COOKTOP WALL HOODS

Wolf ventilation hoods utilize a 6 button control panel with LED indicators, mounted along the right front edge of the unit. (See Figure 3-1)

The LIGHT button turns the halogen lights on and off, and allows the user to choose from three lighting levels: high, medium, and low.

The HIGH, MEDIUM, and LOW buttons control the operational speed of the remote or internal blower. An LED indicator below the button indicates the speed of blower operation.

To turn the blower off, depress the button over the illuminated LED.

The DELAY button activates the delay feature, which allows the blower to continue running at the selected speed for a programmed time period after the button is depressed.

When in Delay mode, both the Delay LED and the corresponding blower speed LED will be illuminated.

The FILTER button monitors the use of the hood. After 30 hours of use at medium speed, the Filter LED will illuminate, indicating the filters should be removed and cleaned. Depress the Filter button to reset the Filter clean LED.

LED Indicators

Figure 3-1 illustrates the controls and their corresponding LED indicators for Wall and Island Hoods.

HEAT SENTRY MODE

Heat Sentry Mode is always on standby and is activated when the exhaust temperature from the hood reaches 206°F (97°C). When this temperature is reached, the blower motor speed will automatically adjust to the next highest speed, or turn on if the blower motor was off. The LED of the corresponding blower speed will flash on and off to indicate Heat Sentry Mode.

Once in Heat Sentry Mode, the hood will continue to monitor exhaust temperatures every three minutes. If the exhaust temperature is at or exceeds 206°F (97°C), the blower speed will be increased to the next highest speed, and the corresponding LED will begin to flash. If, after three minutes, the exhaust temperature falls below 174°F (79°C), the blower speed will decrease to the next lowest speed. If the blower was off prior to Heat Sentry Mode, the unit will turn off when exiting Heat Sentry Mode.

When the blower speed returns to its original setting prior to Heat Sentry Mode activation, the corresponding LED will stop flashing and remain constant.

ELECTRONIC CONTROL FOR LOW PROFILE HOODS

The Wolf cooktop low-profile hood is operated using the touch control pads on the front face of the hood. (Figure 3-3)

LIGHTS: Touch the pad once to turn the lights ON, touch a second time to turn the lights ON to a brighter level, and touch a third time to turn the lights OFF.

0-1: Touch activates the blower motor at the first speed (icon is illuminated). Press the pad for about two seconds to turn the blower OFF.

2: Activates the blower at the second speed.

3: Activates the blower at the third speed.

4: Activates the blower at the fourth speed.

A: Touch the pad to set a TIMER which keeps the blower operating at the current speed for 10 minutes.

F - FILTER: After 30 hours of operation, the icon is illuminated to indicate that the grease filter(s) must be cleaned. After 120 hours, the icon flashes to indicate that the grease filter(s) must be cleaned and the charcoal filter replaced. To reset the hour counter, touch (F) while the icon is illuminated or flashing.

Models: DD30 CT Hoods and DD Ventilation, DD30, CT Hoods and DD Ventilation, Hoods and DD Ventilation, DD Ventilation, Ventilation

PDF preview unavailable. Download the PDF instead.

Service Manual - CT, CTE Hoods & 9 Down -22-23 iTextSharp™ 5.5.5 ©2000-2014 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.5 ©2000-2014 iText Group NV (AGPL-version)

Related Documents

Preview Wolf CT Hoods and DD Ventilation Troubleshooting Guide
Comprehensive troubleshooting guide for Wolf CT Hoods and Downdraft Ventilation systems, providing diagnostic steps, common issues, and repair solutions for service technicians.
Preview Wolf CT Hoods and DD Ventilation General Information and Installation
This document provides general information, warranty details, model descriptions, and installation dimensions for Wolf CT Hoods and DD Ventilation products. It includes safety warnings, technical assistance contact information, and a breakdown of the model numbering system.
Preview Wolf CT Hoods and DD Ventilation Technical Data
Technical data for Wolf CT Hoods and DD Ventilation, including supply voltage requirements, temperature parameters, component output levels, and fuse specifications.
Preview Wolf CT Hoods and DD Ventilation: Access & Removal Guide
This guide provides detailed instructions for accessing and removing components from Wolf Pro Series CT Hoods and DD Ventilation units. It covers procedures for filter removal, halogen bulb and light assembly, heat sentry, lamp-holder support, user interface switch mounting bracket, ribbon cable, power outlet, transformer, fuse, internal blower, and control board.
Preview Wolf CT Hoods and DD Ventilation Wiring Schematics
Detailed wiring schematics for Wolf CT Hoods and DD Ventilation models, including DD30, DD36, and various INT/EXT blower configurations.
Preview Wolf M Series Ovens Design Guide
Explore the Wolf M Series Ovens Design Guide for detailed specifications, installation requirements, and electrical information for various models including single and double ovens in transitional, professional, and contemporary styles. Learn about planning, electrical needs, and dimensions for seamless integration into your kitchen design.
Preview Wolf V-Series Cooktop Hoods - General Information and Warranty
General information, technical assistance, and warranty details for Wolf V-Series Cooktop Hoods, including model number key and information plate specifications.
Preview Wolf V-Series Cooktop Hoods Technical Data
Technical data for Wolf V-Series Cooktop Hoods, including blower specifications, general use and care information, and specific instructions for black hoods and stainless steel/glass hoods.