Mitsubishi Electric Heating and Cooling

Submittal Data: PVA-A36AA7 & PUZ-HA36NKA

36,000 BTU/H Multi Position AHU Cold Climate Heat Pump System

Job Information

Job Name: Location:
Purchaser: Submitted By:
Submitted To: Reference: Approval: Construction:
Engineer: Date: Application:

Product Images

Images provided for reference purposes only.

Outdoor Unit: [Image of outdoor unit]

Indoor Unit: [Image of indoor unit]

Optional Controller: [Image of optional controller]

Outdoor Standard Features

Feature Description
Blue Fin Coating Prolongs condenser operating life
Inverter Motor Energy efficient operation with variable speed DC motor
Built in base pan heater Automated control to prevent premature failure of condenser coil
Auto mode Automatically switches between heating & cooling modes
Fast Auto restart Automatically restarts after power failure return
Auxiliary heat lock out Prevents premature activation of aux. heat
Automated compressor cutout Prevents inefficient operation & protects compressor
Cold climate heat pump

Indoor Standard Features

Feature Description
Multi position Increases application in tight spaces
Less than 2% air leakage At 1.0 in. WG, ASHRAE standard 193
Built in humidification & ventilation controls Controls humidifier and ventilator
Direct auxiliary heat control Heat pump system controls aux. heat
Condensate overflow fail safe CN4F, condensate overflow safety switch connector

Description (Optional Accessories)

Accessory Model No.
Front Windscreen CM-S-FR-NKMU (x2 required)
Front Windscreen Blocker CM-S-BLK-NKMU (x2 per box)
Rear Snow Guard SG-1-RE
Side Snow Guard SG-1-SD
Return Air Intake PV-RTN-36-42
Electric Heater Kit - 10kW EH10-MPA-LB
Electric Heater Kit - 15kW EH15-MPAS-LB
Terminal Block Kit SPTB1
Distribution Pipe used for Twinning MSDD-50TR-E (refer to manual)

Performance

Rating Unit Value
Cooling at 95°F¹ Rated Capacity Btu/h 33,000
Capacity Range Btu/h 15,500 - 36,000
Rated Power Input W 2,500
Power Input Range W 1,030 - 2,800
Moisture Removal pints/h 3.8
Sensible Heat Factor 0.87
Heating at 47°F² Rated Capacity Btu/h 38,000
Capacity Range Btu/h 18,600 - 40,000
Rated Power Input W 2,850
Power Input Range W 1,000 - 3,070
Maximum Capacity Btu/h 38,000
Rated Capacity Btu/h 24,600
Heating at 17°F³ Capacity Range Btu/h NA - 38,000
Maximum Power Input W 4,895
Rated Power Input W 2,825
Power Input Range W NA - 4,895
Maximum Capacity Btu/h 38,000
Maximum Power Input W 5,651
Heating at 5°F⁴ Maximum Capacity Btu/h 30,400
Maximum Power Input W 5,772
Heating at -13°F⁵ Maximum Capacity Btu/h 30,400
Maximum Power Input W 5,772

Efficiency

Rating Value
SEER¹ 18.2
EER 13.0
HSPF (IV) 11.2
COP at 47°F² 3.90
COP at 17°F³ 2.27
COP at 5°F / -13°F 2.17 / 1.50

Electrical

Parameter Details
Power Supply 208/230V, 1Ph, 60Hz
Voltage: Indoor - Outdoor, S1-S2 V AC, AC 208/230V
Voltage: Indoor - Outdoor, S2-S3 V DC, DC 24V
Short-circuit Current Rating (SCCR) 5 kA
Recommended Fuse/Breaker Size (Outdoor) 35 A
Recommended Wire Size (Indoor - Outdoor) 14 AWG

Operating Temperature Range

Condition Temperature Range
Cooling Operation Air Temp (Maximum / Minimum)* 0 to 115°F (-18 to 46°C)
Cooling Operation Thermal Lock-out / Re-start Temperatures -1 / 3°F (-18 / -16°C)
Heating Operation Air Temp (Maximum / Minimum) -13 to 75°F (-25 to 24°C)
Heating Operation Thermal Lock-out / Re-start Temperatures -22 / -13°F (-30 / -25°C)

Note: Windscreens required for cooling operations below 23°F (-5°C).

AHRI Rated Conditions

Cooling (Indoor // Outdoor): 80°F (26.6°C) DB, 67°F (19.4°C) WB // 95°F (35°C) DB, 75°F (23.9°C) WB

Heating at 47°F (8.3°C) (Indoor // Outdoor): 70°F (21.1°C) DB, 60°F (15.6°C) WB // 47°F (8.3°C) DB, 43°F (6.1°C) WB

Heating at 17°F (-8.3°C) (Indoor // Outdoor): 70°F (21.1°C) DB, 60°F (15.6°C) WB // 17°F (-8.3°C) DB, 15°F (-9.4°C) WB

Heating at 5°F (-15°C) (Indoor // Outdoor): 70°F (21.1°C) DB, 60°F (15.6°C) WB // 5°F (-15°C) DB, 4°F (-15.6°C) WB

Heating at -13°F (-25°C) (Indoor // Outdoor): 70°F (21.1°C) DB, 60°F (15.6°C) WB // -13°F (-25°C) DB, -15°F (-26.1°C) WB

Indoor Unit Specifications

Parameter Unit Value
MCA A 5.5
MOCP (only used with SPTB1 powering Indoor separately) A 15
Blower Motor Full Load Amperage A 4.40
Blower Motor Output W 431
External Static Pressure in. WG 0.30 - 0.50 - 0.80
Airflow Rate at Cooling, Dry CFM 788 - 956 - 1,125
Airflow Rate at Cooling, Wet CFM NA
Airflow Rate at Heating, Dry CFM 788 - 956 - 1,125
Sound Pressure Level (Cooling) dB(A) 32 - 36 - 40
Sound Pressure Level (Heating) dB(A) 32 - 36 - 40
Drain Pipe Size In. (mm) 3/4 (19)
External Finish Color Galvanized steel cabinet - Powder coated Slate Gray
Unit Dimensions W: In. (mm) 25 (635)
D: In. (mm) 21-5/8 (548)
H: In. (mm) 59-1/2 (1,511)
Unit Weight Lbs. (kg) 172 (78)

Outdoor Unit Specifications

Parameter Unit Value
MCA A 26
MOCP A 42
Fan Motor Output W 74 + 74
Airflow Rate (Cooling/Heating) CFM 3,880 / 3,880
Sound Pressure Level, Cooling¹ dB(A) 52
Sound Pressure Level, Heating² dB(A) 53
Refrigerant Control LEV
Compressor Oil Type / Charge oz. FV50S / 47 oz
External Finish Color Ivory Munsell No.3Y 7.8/1.1
Unit Weight Lbs. (kg) 261 (118)
Unit Dimensions W: In. (mm) 41-11/32 (1,050)
D: In. (mm) 12-63/64 + 63/64 (330 +25)
H: In. (mm) 52-43/64 (1,338)
Gas Pipe Size O.D. (Flared) In. (mm) 5/8 (15.88)
Liquid Pipe Size O.D. (Flared) In. (mm) 3/8 (9.52)
Maximum Piping Length Ft. (m) 245 (75)
Maximum Height Difference Ft. (m) 100 (30)

Optional Controls

Description Model No.
Building automated system DDC Interface MELCO-RETAIL-MINI
Building automated system BacNet Interface MELCO-BEMS-MINI
Simple thermostat Interface PAC-US444CN-1
Operation/error display adapter PAC-SA88HA-EP
Remote ON/OFF control PAC-SE55RA-E
Remote compress ON/OFF control PAC-SC36NA-E
Wireless remote receiver PAR-FA32MA-E
Wired wall mounted remote control PAR-40MAA
Wireless wall mounted remote control MHK1
Touch screen wired wall mounted control PAR-CT01MAU-SB
Basic wired wall mounted control PAC-YT53CRAU-J
External heat control adapter PAC-YU25HT-G
Heater control relay PAM-4
Deluxe thermostat interface RMF-CA100-V1
MNet adapter (BacNet/LonWorks BAS sub interface) PAC-SJ95MA-E

Fan Performance and Corrected Airflow

The following charts illustrate fan performance for various external static pressures and airflow rates for the specified voltage.

Note: Charts are for Vertical, Horizontal Right, Horizontal Left, and Downflow airflow directions.

[Fan performance chart for 0.30 in. WG]

[Fan performance chart for 0.50 in. WG]

[Fan performance chart for 0.80 in. WG]

Indoor Unit Outline and Dimensions

Diagrams showing the outline and dimensions of the indoor unit, including knockout hole locations, drain pipe connections, terminal blocks, and air filter dimensions.

Top View: [Diagram of indoor unit top view with dimensions]

Front View: [Diagram of indoor unit front view with dimensions]

Bottom View: [Diagram of indoor unit bottom view with dimensions]

Right Side View: [Diagram of indoor unit right side view with dimensions]

Left Side View: [Diagram of indoor unit left side view with dimensions]

Nominal Filter Size Table:

Model Filter Size (Inches)
PVA-A12AA7 20 x 16 x 1
PVA-A18AA7 20 x 20 x 1
PVA-A24AA7 20 x 24 x 1
PVA-A30AA7 20 x 24 x 1
PVA-A36AA7 20 x 24 x 1
PVA-A42AA7 20 x 24 x 1

Duct Connection Table:

Model Dimensions (Inches)
PVA-A12AA7 376 x 402 (14-13/16 x 15-7/8)
PVA-A18AA7 477 x 402 (18-13/16 x 15-7/8)
PVA-A24AA7 579 x 402 (22-13/16 x 15-7/8)
PVA-A30AA7 579 x 402 (22-13/16 x 15-7/8)
PVA-A36AA7 579 x 402 (22-13/16 x 15-7/8)
PVA-A42AA7 579 x 402 (22-13/16 x 15-7/8)

Dimensions Table:

Model A B C D E F G H J Gas Pipe Liquid Pipe
PVA-A12AA7 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8-7/8) 1275 (50-1/4) 680 (26-13/16) 823 (32-7/16) 735.5 (29) 360 (14-3/16) Φ 12.7 (1/2) Φ 6.35 (1/4)
PVA-A18AA7 534 (21) 477 (18-13/16) 382.6 (15-1/8) 266.5 (10-1/2) 1378 (54-1/4) 737 (29-1/16) 953.5 (37-9/16) 792 (31-3/16) 461 (18-3/16) Φ 15.88 (5/8) Φ 9.52 (3/8)
PVA-A24AA7 534 (21) 477 (18-13/16) 382.6 (15-1/8) 317.5 (12-1/2) 1378 (54-1/4) 737 (29-1/16) 953.5 (37-9/16) 792 (31-3/16) 461 (18-3/16) Φ 15.88 (5/8) Φ 9.52 (3/8)
PVA-A30AA7 635 (25) 579 (22-13/16) 484.6 (19-1/8) 317.5 (12-1/2) 1511 (59-1/2) 798.5 (31-7/16) 1053 (41-1/2) 853.5 (33-5/8) 563 (22-3/16) Φ 15.88 (5/8) Φ 9.52 (3/8)
PVA-A36AA7 635 (25) 579 (22-13/16) 484.6 (19-1/8) 317.5 (12-1/2) 1511 (59-1/2) 798.5 (31-7/16) 1053 (41-1/2) 853.5 (33-5/8) 563 (22-3/16) Φ 15.88 (5/8) Φ 9.52 (3/8)
PVA-A42AA7 635 (25) 579 (22-13/16) 484.6 (19-1/8) 317.5 (12-1/2) 1511 (59-1/2) 798.5 (31-7/16) 1053 (41-1/2) 853.5 (33-5/8) 563 (22-3/16) Φ 15.88 (5/8) Φ 9.52 (3/8)

Outdoor Unit Outline and Dimensions

Diagrams showing the outline and dimensions of the outdoor unit, including air intake, terminal block connections, and overall unit measurements.

[Diagram of outdoor unit outline and dimensions]

Notes:

Unit: mm (in)

Dimensions: [Table with outdoor unit dimensions]

Certifications

AHRI CERTIFIED® Unitary Small HP. Certification applies only when the complete system is listed with AHRI Directory. AHRI Standard 210/240.

ETL LISTED C US Intertek

Models: PVA-A36AA7, PUZ-HA36NKA, PVA-A36AA7 Multi Position AHU Cold Climate Heat Pump System, PVA-A36AA7, Multi Position AHU Cold Climate Heat Pump System, AHU Cold Climate Heat Pump System, Heat Pump System, Pump System, System

PDF preview unavailable. Download the PDF instead.

SB PVA-A36AA7 PUZ-HA36NKA 202401 Acrobat Distiller 20.0 (Windows)

Related Documents

Preview Mitsubishi Electric MSZ-FS09NA-U1 & MUZ-FS09NAH-U1 Cold Climate Heat Pump System Submittal Data
Technical specifications and performance data for the Mitsubishi Electric MSZ-FS09NA-U1 and MUZ-FS09NAH-U1 Wall-Mounted Cold Climate Heat Pump System, including cooling and heating capacities, efficiency ratings, electrical specifications, dimensions, and optional controls and accessories.
Preview Mitsubishi P-Series PKA-A36KA7 & PUZ-A36NKA7 Heat Pump System Submittal Data
Detailed submittal data, specifications, features, and dimensions for the Mitsubishi Electric P-Series PKA-A36KA7 indoor unit and PUZ-A36NKA7/(-BS) outdoor unit, a 36,000 BTU/h wall-mounted heat pump system.
Preview Mitsubishi Electric PVA-AA48NL & PUZ-AK48NLHZ: Air Handler & Heat Pump Specs
Explore the technical specifications, features, and performance data for the Mitsubishi Electric PVA-AA48NL indoor air handler and PUZ-AK48NLHZ outdoor Hyper Heat Pump unit.
Preview Mitsubishi Electric Air to Water Heat Pump Parts Catalog R32
Comprehensive parts catalog for Mitsubishi Electric R32 split-type air to water heat pumps, including structural and electrical components, with part numbers and quantities for various models.
Preview Mitsubishi Electric Residential Product Data Charts
Comprehensive data charts for Mitsubishi Electric's residential HVAC products, including specifications for ZUBA Cold Climate and Hybrid systems, covering cooling and heating capacities, power consumption, efficiency ratings, dimensions, and operating ranges.
Preview Mitsubishi Electric PVA-AA48NL & PUZ-AK48NL Air Handler and Heat Pump Specifications
Detailed specifications, features, and dimensions for the Mitsubishi Electric PVA-AA48NL Multi-Position Air Handler Indoor Unit and PUZ-AK48NL Heat Pump Outdoor Unit, including performance data and accessory information.
Preview Mitsubishi Electric Heat Pump Product Information and Technical Data
Comprehensive technical specifications and energy efficiency data for Mitsubishi Electric heat pump systems, including space heaters and combination heaters, compliant with EU regulations.
Preview Mitsubishi Electric 36,000 BTU/h Ceiling Cassette: PLA-A36EA7 & PUZ-HA36NKA
Detailed specifications and features for the Mitsubishi Electric 36,000 BTU/h Ceiling Cassette air conditioning system, including the PLA-A36EA7 indoor unit and PUZ-HA36NKA outdoor unit. Covers indoor and outdoor unit features, technical specifications, and available accessories.