Spot Check Evaluation
Report No.: 301717-03
Report Issued Date: Nov. 13, 2023
Test Subject Information
Applicant: Motorola Mobility LLC
Equipment: Mobile Cellular Phone
Brand Name: Motorola
Model Name: XT2423-3
FCC ID: IHDT56AP2
Standard: 47 CFR Part 2, 22(H), 24(E), 27(M), 47 CFR Part 15 Subpart C §15.247, 47 CFR Part 15 Subpart E §15.407
Sporton International Inc. (ShenZhen) declares that the tested sample has been evaluated in accordance with the test procedures and is in compliance with the applicable technical standards. The test results apply exclusively to the tested model/sample. Without written approval, the report shall not be reproduced except in full.
Approved by: Jason Jia
Sporton International Inc. (ShenZhen)
1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen, 518055
People's Republic of China
Revision History
REPORT NO. | VERSION | DESCRIPTION | ISSUED DATE |
---|---|---|---|
301717-03 | Rev. 01 | Initial issue of report | Nov. 13, 2023 |
Conformity Assessment Condition:
- The test results (PASS/FAIL) with all measurement uncertainty excluded are presented against the regulation limits or in accordance with the requirements stipulated by the applicant/manufacturer.
- Measurement uncertainty refers to the "Measurement Uncertainty" section.
Disclaimer:
Product specifications affecting test assessments are declared by the manufacturer, who takes full responsibility for authenticity.
General Description
Applicant
Motorola Mobility LLC
222 W. Merchandise Mart Plaza, Chicago IL 60654, USA
Manufacturer
Motorola Mobility LLC
222 W. Merchandise Mart Plaza, Chicago IL 60654, USA
Product Feature of Equipment Under Test
Equipment | Product Feature |
---|---|
Mobile Cellular Phone | Motorola |
Model Name | XT2423-3 |
FCC ID | IHDT56AP2 |
IMEI Code | Conducted: 351556610011195/351556610013902 Radiation: 351556610010239/351556610012946 |
HW Version | DVT2 |
SW Version | UTA34.66 |
EUT Stage | Identical Prototype |
Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications or user's manual for more detailed description.
Modification of EUT
No modifications were made to the EUT during all test items.
Testing Site
Sporton International Inc. (ShenZhen) is accredited to ISO/IEC 17025:2017 by American Association for Laboratory Accreditation with Certificate Number 5145.01.
Test Site 1
Test Firm: Sporton International Inc. (ShenZhen)
Address: 1/F, 2/F, Bldg 5, Shiling Industrial Zone, Xinwei Village, Xili, Nanshan, Shenzhen, 518055 People's Republic of China
TEL: +86-755-86379589
FAX: +86-755-86379595
Sporton Site No. | FCC Designation No. | FCC Test Firm Registration No. |
---|---|---|
TH01-SZ | CN1256 | 421272 |
Test Site 2
Test Firm: Sporton International Inc. (ShenZhen)
Address: 101, 1st Floor, Block B, Building 1, No. 2, Tengfeng 4th Road, Fenghuang Community, Fuyong Street, Baoan District, Shenzhen City, Guangdong Province 518103 People's Republic of China
TEL: +86-755-86066985
Sporton Site No. | FCC Designation No. | FCC Test Firm Registration No. |
---|---|---|
03CH01-SZ | CN1256 | 421272 |
Test Software
Item | Site | Manufacturer | Name | Version |
---|---|---|---|---|
1 | 03CH01-SZ | AUDIX | E3 | 6.2009-8-24 |
Applicable Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:
- FCC KDB 484596 D01 Referencing Test Data v02r01
- 47 CFR Part 2, 22(H), 24(E), 27(M)
- 47 CFR Part 15 Subpart C §15.247
- 47 CFR Part 15 Subpart E §15.407
- ANSI C63.10-2013
- ANSI C63.26-2015
Specification of Accessory
Accessory Type | Brand Name | Model Name |
---|---|---|
AC Adapter 1(US) | Motorola (Salcomp) | MC-201L |
AC Adapter 1(EU) | Motorola (Salcomp) | MC-202L |
AC Adapter 1(UK) | Motorola (Salcomp) | MC-203L |
AC Adapter 1(AR) | Motorola (Salcomp) | MC-206L |
AC Adapter 1(AU) | Motorola (Salcomp) | MC-205L |
AC Adapter 2(US) | Motorola (Chenyang) | MC-201L |
AC Adapter 2(EU) | Motorola (Chenyang) | MC-202L |
AC Adapter 2(AR) | Motorola (Chenyang) | MC-206L |
AC Adapter 3(US) | Motorola (AOHAI) | MC-201L |
AC Adapter 3(EU) | Motorola (AOHAI) | MC-202L |
AC Adapter 3(UK) | Motorola (AOHAI) | MC-203L |
AC Adapter 3(AR) | Motorola (AOHAI) | MC-206L |
AC Adapter 3(AU) | Motorola (AOHAI) | MC-205L |
Battery 1 | Motorola (ATL) | QF50 |
Battery 2 | Motorola (sunwoda) | QF50 |
USB Cable 1 | Motorola (Juwei) | JWUB1614-T03H |
USB Cable 2 | Motorola (saibao) | STN-A128A |
Re-use of Measured Data
Introduction Section
This application re-uses data collected on a similar device. The subject device (Model: XT2423-3, FCC ID: IHDT56AP2) is electrically identical to the reference device (Model: XT2423-1, FCC ID: IHDT56AP1) for the portions of the circuitry corresponding to the data being re-used. Based on their similarity, the FCC Part 15C (equipment class: DTS, DSS) and FCC Part 15E (equipment class: NII) and FCC Part 22, 24, 27 (equipment class: PCE) reuse the original model's result and include spot-checks, following the FCC KDB 484596 D01 Referencing Test Data v02r01.
The applicant takes full responsibility that the test data as referenced in this report represent compliance for this FCC ID: IHDT56AP2.
Model Difference Information
The main differences between FCC ID: IHDT56AP2 and FCC ID: IHDT56AP1 (Model: XT2423-1) are:
- Removal of WCDMA Band IV, LTE B4/13/26/66.
- Addition of NFC function, LTE B20/41.
Other differences and details of similarity/difference can be found in the confidential documents (XT2423-3_Operational Description of Product Equality Declaration).
Reference Detail Section
Rule Part | Equipment Class | Frequency Band (MHz) | Reference FCC ID (Parent) | Type Grant/ Permissive Change | Reference Title | FCC ID Filling (Variant) | Report Title/Section |
---|---|---|---|---|---|---|---|
15C (DSS) | DSS (BR/EDR) | 2400~2483.5 | IHDT56AP1 | Original Grant | FR3O1717A | IHDT56AP2 | All sections applicable |
15C (DTS) | DTS (BLE) | 2400~2483.5 | IHDT56AP1 | Original Grant | FR3O1717B | IHDT56AP2 | All sections applicable |
15C (DTS) | DTS (WLAN) | 2400~2483.5 | IHDT56AP1 | Original Grant | FR3O1717C | IHDT56AP2 | All sections applicable |
15E (U-NII) | 5180~5240 | IHDT56AP1 | Original Grant | FR3O1717D | IHDT56AP2 | All sections applicable | |
5260~5320 | IHDT56AP1 | Original Grant | FR3O1717D FZ3O1717 | IHDT56AP2 | All sections applicable | ||
5500~5720 | IHDT56AP1 | Original Grant | FR3O1717D FZ3O1717 | IHDT56AP2 | All sections applicable | ||
5745~5825 | IHDT56AP1 | Original Grant | FR3O1717D | IHDT56AP2 | All sections applicable | ||
22, 24, 27 (PCE) | PCE (GSM) | GSM 850/1900 | IHDT56AP1 | Original Grant | FG3O1717A | IHDT56AP2 | All sections applicable |
PCE (WCDMA) | Band II, V | IHDT56AP1 | Original Grant | FG3O1717A | IHDT56AP2 | All sections applicable | |
PCE (LTE) | B2/7/38 | IHDT56AP1 | Original Grant | FG3O1717B | IHDT56AP2 | All sections applicable |
Spot Check Verification Data Section
Conducted power test and radiated spurious emission test against the variant model were performed based on the worst-case condition from the original model to demonstrate that the test data from the original model remains representative for the variant model. All test procedures followed the related section of the parent report.
For any given test, the maximum identified difference between spot check and reference data shall be no larger than 25%, in linear units.
The formula used is: |spot check data – reference data| / |reference data| ≤ 0.25, where "|" denotes the absolute value of the measured quantity.
Summary for Power and RSE Spot Check
Conducted Power (dBm)
Test Item | Mode | IHDT56AP1 Parent Worst Result | IHDT56AP2 Variant Check Test Result | Difference | Limit |
---|---|---|---|---|---|
BT BR/EDR | 11.75 | 11.49 | 0.058 | 0.25 | |
BLE 1M | 3.04 | 3.02 | 0.005 | 0.25 | |
BLE 2M | 3.03 | 3.01 | 0.005 | 0.25 | |
11b 2.4G | 20.78 | 19.98 | 0.168 | 0.25 | |
11g_2.4G | 25.11 | 24.97 | 0.032 | 0.25 | |
11n20 2.4G | 25.31 | 25.13 | 0.041 | 0.25 | |
11n40 2.4G | 25.18 | 24.92 | 0.058 | 0.25 | |
11a 5G | 17.84 | 17.71 | 0.029 | 0.25 | |
11n20 5G | 17.84 | 17.41 | 0.094 | 0.25 | |
11n40 5G | 16.87 | 16.39 | 0.105 | 0.25 | |
11ac80 5G | 15.80 | 15.37 | 0.094 | 0.25 | |
GSM 850 | 32.39 | 32.13 | 0.058 | 0.25 | |
PCS1900 | 29.54 | 29.88 | 0.081 | 0.25 | |
WCDMA Band II | 22.88 | 23.28 | 0.096 | 0.25 | |
WCDMA Band V | 22.92 | 22.94 | 0.005 | 0.25 | |
LTE Band 2 | 22.91 | 22.98 | 0.016 | 0.25 | |
LTE Band 7 | 22.99 | 22.86 | 0.029 | 0.25 | |
LTE Band 38 | 23.03 | 22.80 | 0.052 | 0.25 |
For example: BT BR/EDR (dBm): mW = 10^(dBm/10). Difference = |spot check data – reference data| / |reference data| = |10^(11.49/10) - 10^(11.75/10)| / |10^(11.75/10)| = 0.058
Radiated Spurious Emission
Test Item | Mode | IHDT56AP1 Parent Worst Result | IHDT56AP2 Variant Check Result | Difference (dB) |
---|---|---|---|---|
Radiated Spurious Emission (dBuV/m) | BT BR/EDR | 48.79 | 49.20 | -0.41 |
BLE | 42.13 | 39.99 | 2.14 | |
11n20 2.4G | 50.58 | 50.84 | -0.26 | |
11n20 5G U-NII-2C | 65.26 | 64.13 | 1.13 | |
Radiated Spurious Emission (dBm) | GSM 850 | -49.71 | -47.43 | -2.28 |
WCDMA Band II | -53.61 | -53.03 | -0.58 | |
LTE Band 7 | -51.24 | -51.31 | 0.07 |
Remark: The ECR was approved by FCC, although the RSE difference exceeds the 0.25 limit.
Conclusion
Radiated spurious emission tests against the variant model, based on the worst-case condition from the original model, were performed to demonstrate that the test data from the original model remains representative for the variant model. The power level and RSE spot checks are shown within expected levels compliant to the limit line.
Power and ERP/EIRP measurements from the original parent model reports are used for the grant.
The same DFS detection is used in the variant; therefore, there is no spot check data for DFS.
We confirm that the test data reuse policy of FCC KDB 484596 D01 Referencing Test Data v02r01 has been followed, and the test data referenced from the parent model report represents compliance with the new FCC ID.
List of Measuring Equipment
Instrument | Manufacturer | Model No. | Serial No. | Characteristics | Calibration Date | Test Date | Due Date | Remark |
---|---|---|---|---|---|---|---|---|
Spectrum Analyzer | R&S | FSV40 | 101078 | 10Hz~40GHz | Apr. 06, 2023 | Nov. 07, 2023 | Apr. 05, 2024 | Conducted (TH01-SZ) |
Pulse Power Sensor | Anritsu | MA2411B | 1339473 | 30MHz~40GHz | Dec. 27, 2022 | Nov. 07, 2023 | Dec. 26, 2023 | Conducted (TH01-SZ) |
Power Meter | Anritsu | ML2495A | 1542004 | 50MHz Bandwidth | Dec. 27, 2022 | Nov. 07, 2023 | Dec. 26, 2023 | Conducted (TH01-SZ) |
Power Divider | TOJOIN | PS-2SM-0426 | 60.06.020.007 | 0.4GHz~26.5GHz | Dec. 25, 2022 | Nov. 07, 2023 | Dec. 24, 2023 | Conducted (TH01-SZ) |
EMI Test Receiver&SA | Agilent | N9038A | MY52260185 | 20Hz~26.5GHz | Dec. 26, 2022 | Oct. 30, 2023 | Dec. 25, 2023 | Radiation (03CH01-SZ) |
EXA Spectrum Analyzer | KEYSIGHT | N9010A | MY55150213 | 10Hz~44GHz | Jul. 07, 2023 | Oct. 30, 2023 | Jul. 06, 2024 | Radiation (03CH01-SZ) |
Loop Antenna | R&S | HFH2-Z2 | 100354 | 9kHz~30MHz | Jul. 28, 2022 | Oct. 30, 2023 | Jul. 27, 2024 | Radiation (03CH01-SZ) |
Bilog Antenna | TeseQ | CBL6112D | 35407 | 30MHz~2GHz | Oct. 24, 2023 | Oct. 30, 2023 | Oct. 23, 2025 | Radiation (03CH01-SZ) |
Double Ridge Horn Antenna | ETS-Lindgren | 3117 | 00119436 | 1GHz~18GHz | Jul. 08, 2023 | Oct. 30, 2023 | Jul. 07, 2024 | Radiation (03CH01-SZ) |
SHF-EHF Horn | com-power | AH-840 | 101071 | 18Ghz~40GHz | Apr. 08, 2023 | Oct. 30, 2023 | Apr. 07, 2024 | Radiation (03CH01-SZ) |
LF Amplifier | Burgeon | BPA-530 | 002709 | 0.01~3000Mhz | Apr. 04, 2023 | Oct. 30, 2023 | Apr. 03, 2024 | Radiation (03CH01-SZ) |
HF Amplifier | MITEQ | AMF-7D-0010-1800-30-10P-R | 1943528 | 1GHz~18GHz | Oct. 18, 2023 | Oct. 30, 2023 | Oct. 17, 2024 | Radiation (03CH01-SZ) |
HF Amplifier | KEYSIGHT | 83017A | MY53270105 | 0.5GHz~26.5GHz | Oct. 18, 2023 | Oct. 30, 2023 | Oct. 17, 2024 | Radiation (03CH01-SZ) |
HF Amplifier | MITEQ | TTA1840-35-HG | 1871923 | 18GHz~40GHz | Jul. 07, 2023 | Oct. 30, 2023 | Jul. 06, 2024 | Radiation (03CH01-SZ) |
AC Power Source | Chroma | 61601 | 616010001985 | N/A | Oct. 18, 2023 | Oct. 30, 2023 | Oct. 17, 2024 | Radiation (03CH01-SZ) |
Turn Table | EM | EM1000 | N/A | 0~360 degree | NCR | Oct. 30, 2023 | NCR | Radiation (03CH01-SZ) |
Antenna Mast | EM | EM1000 | N/A | 1 m~4 m | NCR | Oct. 30, 2023 | NCR | Radiation (03CH01-SZ) |
NCR: No Calibration Required.
Measurement Uncertainty
Uncertainty of Conducted Measurement
Test Item | Uncertainty |
---|---|
Conducted Power | ±1.34 dB |
Part 15C/15E: Uncertainty of Radiated Emission Measurement
Measurement Type | Uncertainty |
---|---|
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) (30 MHz ~ 1000 MHz) | 4.2dB |
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) (1 GHz ~ 18 GHz) | 5.0dB |
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) (18 GHz ~ 40 GHz) | 4.3dB |
Part 22/24/27: Uncertainty of Radiated Emission Measurement
Measurement Type | Uncertainty |
---|---|
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) (30 MHz ~ 1000 MHz) | 2.48dB |
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) (1 GHz ~ 18 GHz) | 3.53dB |
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) (18 GHz ~ 40 GHz) | 4.02dB |