IHDT56AQ2 TestRpt Spot Check

Motorola Mobility LLC T56AQ2 Mobile Cellular Phone IHDT56AQ2 IHDT56AQ2 t56aq2

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=6917112
FCC RF Test Report

Report No. : 392114-01

Spot Check Evaluation

APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID STANDARD

: Motorola Mobility LLC
: Mobile Cellular Phone
: Motorola
: XT2363-3
: IHDT56AQ2 : 47 CFR Part 2, 22(H), 24(E), 27(M), 27(Q), 90(S)
47 CFR Part 15 Subpart C §15.225 47 CFR Part 15 Subpart C §15.247 47 CFR Part 15 Subpart E §15.407

We, Sporton International Inc. (Kunshan), would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards.
The test results in this report apply exclusively to the tested model / sample. Without written approval of Sporton International Inc. (Kunshan), the test report shall not be reproduced except in full.

Approved by: Jason Jia
Sporton International Inc. (Kunshan)
No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 1 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

TABLE OF CONTENTS
REVISION HISTORY..........................................................................................................................................3
1 GENERAL DESCRIPTION..........................................................................................................................4
1.1 Applicant ............................................................................................................................................ 4 1.2 Manufacturer......................................................................................................................................4 1.3 Product Feature of Equipment Under Test........................................................................................4 1.4 Modification of EUT ........................................................................................................................... 4 1.5 Testing Site ........................................................................................................................................ 5 1.6 Test Software.....................................................................................................................................5 1.7 Applicable Standards.........................................................................................................................5 1.8 Specification of Accessory.................................................................................................................6
2 RE-USE OF MEASURED DATA.................................................................................................................7
2.1 Introduction Section ........................................................................................................................... 7 2.2 Model Difference Information ............................................................................................................ 7 2.3 Reference detail Section: .................................................................................................................. 8 2.4 Spot Check Verification Data Section................................................................................................9
3 LIST OF MEASURING EQUIPMENT........................................................................................................11
4 MEASUREMENT UNCERTAINTY ............................................................................................................12 APPENDIX A. SETUP PHOTOGRAPHS

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 2 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

REVISION HISTORY

REPORT NO. 392114-01

VERSION

DESCRIPTION

Rev. 01 Initial issue of report

Report No. : 392114-01
ISSUED DATE Nov. 06, 2023

Conformity Assessment Condition:
1. The test results (PASS/FAIL) with all measurement uncertainty excluded are presented against the regulation limits or in accordance with the requirements stipulated by the applicant/manufacturer who shall bear all the risks of non-compliance that may potentially occur if measurement uncertainty is taken into account.
2. The measurement uncertainty please refer to each test result in the section "Measurement Uncertainty"
Disclaimer:
The product specifications of the EUT presented in the test report that may affect the test assessments are declared by the manufacturer who shall take full responsibility for the authenticity.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 3 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

1 General Description
1.1 Applicant
Motorola Mobility LLC 222 W,Merchandise Mart Plaza, Chicago IL 60654 USA
1.2 Manufacturer
Motorola Mobility LLC 222 W,Merchandise Mart Plaza, Chicago IL 60654 USA

1.3 Product Feature of Equipment Under Test

Product Feature

Equipment

Mobile Cellular Phone

Brand Name

Motorola

Model Name

XT2363-3

FCC ID

IHDT56AQ2

IMEI Code

Conducted: 352643330023178/352643330023186 Radiation: 352643330019572/352643330019580

HW Version

DVT2

SW Version

UUG34.30

EUT Stage

Identical Prototype

Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications

or user's manual for more detailed description.

1.4 Modification of EUT
No modifications are made to the EUT during all test items.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 4 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

1.5 Testing Site

Sporton International Inc. (Kunshan) is accredited to ISO/IEC 17025:2017 by American Association for

Laboratory Accreditation with Certificate Number 5145.02.

Test Firm

Sporton International Inc. (Kunshan)

Test Site Location

No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China TEL : +86-512-57900158

Test Site No.

Sporton Site No.
03CH02-KS 03CH04-KS
TH01-KS

FCC Designation No. CN1257

FCC Test Firm Registration No.
314309

1.6 Test Software

Item 1.

Site TH01-KS

2.

TH01-KS

3.

TH01-KS

4.

TH01-KS

5.

TH01-KS

6.

03CH02-KS

7.

03CH04-KS

Manufacturer SPORTON
SPORTON
SPORTON SPORTON SPORTON AUDIX AUDIX

Name FCC 15C-15E Test Tools Ver10.0_210607 FCC BT2.0 Ver3.0_For_CHINA_190111 FCC LTE_Ver2.0 Auto_china_210503
Part2224_Ver5.0 200330
FCC_5GNR_China_201027
E3
E3

Version 10.0
3.0
2.0 5.0 1.0 6.2009-8-24al 210616

1.7 Applicable Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:  FCC KDB 484596 D01 Referencing Test Data v01  47 CFR Part 2, 22(H), 24(E), 27(M), 27(Q), 90(S)  47 CFR Part 15 Subpart C §15.225  47 CFR Part 15 Subpart C §15.247  47 CFR Part 15 Subpart E §15.407  ANSI C63.10-2013  ANSI C63.26-2015

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 5 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

1.8 Specification of Accessory

AC Adapter 1(US) AC Adapter 1(EU) AC Adapter 1(UK) AC Adapter 1(AU) AC Adapter 1(AR) AC Adapter 1(IN) AC Adapter 2(US) AC Adapter 2(EU) AC Adapter 2(UK) AC Adapter 2(AU) AC Adapter 2(AR) AC Adapter 2(BR) AC Adapter 2(Chile) AC Adapter 3(BR) AC Adapter 4(BR local) AC Adapter 5(IN local) Battery 1 Battery 2 Battery 3 USB Cable 1 USB Cable 2 USB Cable 3

Specification of Accessory

Brand Name Motorola (Aohai)

Model Name

Brand Name Motorola (Aohai)

Model Name

Brand Name Motorola (Aohai)

Model Name

Brand Name Motorola (Aohai)

Model Name

Brand Name Motorola (Aohai)

Model Name

Brand Name Motorola (Aohai)

Model Name

Brand Name Motorola (Salcomp)

Model Name

Brand Name Motorola (Salcomp)

Model Name

Brand Name Motorola (Salcomp)

Model Name

Brand Name Motorola (Salcomp)

Model Name

Brand Name Motorola (Salcomp)

Model Name

Brand Name Motorola (Salcomp)

Model Name

Brand Name Motorola (Salcomp)

Model Name

Brand Name Motorola (Chenyang)

Model Name

Brand Name Motorola (Cliptech)

Model Name

Brand Name Motorola (XIHI)

Model Name

Brand Name Motorola (ATL)

Model Name

Brand Name Motorola (SCUD)

Model Name

Brand Name Motorola (Sunwoda)

Model Name

Brand Name Motorola (Saibao)

Model Name

Brand Name Motorola (Juwei )

Model Name

Brand Name Motorola (Washin)

Model Name

MC-201L MC-202L MC-203L MC-205L MC-206L MC-204 MC-201L MC-202L MC-203L MC-205L MC-206L MC-207L MC-209L MC-207L MC-207L MC-204 QF50 QF50 QF50 SZN-A026A JWUB1606-ZN01H HX-ZN-19

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 6 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

2 Re-use of Measured Data
2.1 Introduction Section
This application re-uses data collected on a similar device. The subject device of this application (Model: XT2363-3, FCC ID: IHDT56AQ2) is electrically identical to the reference device (Model: XT2363-2, XT2363-1, FCC ID: IHDT56AQ1) for the portions of the circuitry corresponding to the data being re-used. Based on their similarity, the FCC Part 15C (equipment class: DTS, DSS, DXX) and FCC Part 15E (equipment class: NII) and FCC Part 22, 24, 27, 90 (equipment class: PCE) reuse the original model's result and do spot-check, following the FCC KDB 484596 D01 Referencing Test Data v01.
The applicant takes full responsibility that the test data as referenced in this report represent compliance for this FCC ID: IHDT56AQ2 .
2.2 Model Difference Information
The main difference between FCC ID: IHDT56AQ1 and FCC ID: IHDT56AQ2 is as below: · Remove WCDMA IV, LTE B4/12/13/17/25/66 and 5G NR n2/n66. · Add LTE B20/32 and 5G NR n8/n20/n77.
Other differences and all the details of similarity and difference can be found in the confidential documents (XT2363-3_Operational Description of Product Equality Declaration).

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 7 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

2.3 Reference detail Section:

Rule Equipment Part Class
DSS (BR/EDR)
DTS (BLE) 15C DTS (WLAN)
DXX (NFC)

Frequency Band (MHz)
2400~2483.5
2400~2483.5
2400~2483.5
13.56
5180~5240

15E U-NII

5260~5320 5500~5720

PCE (GSM)

PCE (WCDMA)

22,

PCE

24,

(LTE)

27,

PCE

90

(LTE)

PCE (LTE)

PCE (NR)

5745~5825
GSM 850/1900
Band II, V
B2/5/7/26 ULCA 7C
B26 (90S) B42 (Part27Q)
n5/n7/n26/n38/n41

Reference FCC ID (Parent)
IHDT56AQ1

Type Grant/ Permissive
Change
Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

IHDT56AQ1

Original Grant

Reference Title
FR392114A
FR392114B
FR392114C
FR392114D
FR392114E FR392114E FZ392114 FR392114E FZ392114 FR392114E
FG392114A
FG392114A FG392114B FG392114C FG392114D
FG392114E
FG392114G

FCC ID Filling (Variant) IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2

Report Title/Section
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable
All sections applicable

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 8 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

2.4 Spot Check Verification Data Section

Conducted power test and radiated spurious emission test against the variant model based on the

worst-case condition from the original model was performed in this filing to demonstrate the test data

from original model remains representative for the variant model.

All test procedures follow the related section of parent report.

Summary for power and RSE spot check for each rule entry and technology is listed as below:

Test Item

Mode

IHDT56AQ1 Parent
Worst mode Test Result

IHDT56AQ2 Variant
Check Test Result

Difference (dB)

BT BR/EDR

17.22

16.21

1.01

BLE 1M

10.43

10.39

0.04

BLE 2M

10.64

10.61

0.03

WLAN 2.4G 11b

21.66

21.41

0.25

WLAN 2.4G 11g

23.43

23.39

0.04

WLAN 2.4G 11n20

23.43

23.28

0.15

WLAN 2.4G 11n40

22.37

22.24

0.13

WLAN 5G 11a UNII-1

18.19

18.11

0.08

WLAN 5G 11a UNII-2A

18.65

18.57

0.08

WLAN 5G 11a UNII-2C

18.66

18.41

0.25

WLAN 5G 11a UNII-3

18.59

18.31

0.28

WLAN 5G 11n20 UNII-1

17.99

17.95

0.04

WLAN 5G 11n20 UNII-2A

18.50

18.42

0.08

WLAN 5G 11n20 UNII-2C

18.55

18.23

0.32

WLAN 5G 11n20 UNII-3

18.49

18.28

0.21

WLAN 5G 11n40 UNII-1

16.48

16.46

0.02

WLAN 5G 11n40 UNII-2A

16.89

16.83

0.06

WLAN 5G 11n40 UNII-2C

16.93

16.53

0.40

Conducted

WLAN 5G 11n40 UNII-3

16.78

16.56

0.22

Power

WLAN 5G 11ac20 UNII-1

18.00

17.88

0.12

(dBm)

WLAN 5G 11ac20 UNII-2A

18.51

18.29

0.22

WLAN 5G 11ac20 UNII-2C

18.56

18.17

0.39

WLAN 5G 11ac20 UNII-3

18.50

18.13

0.37

WLAN 5G 11ac40 UNII-1

15.59

15.54

0.05

WLAN 5G 11ac40 UNII-2A

15.99

15.94

0.05

WLAN 5G 11ac40 UNII-2C

15.99

15.82

0.17

WLAN 5G 11ac40 UNII-3

15.96

15.59

0.37

WLAN 5G 11ac80 UNII-1

12.71

12.61

0.10

WLAN 5G 11ac80 UNII-2A

13.83

13.64

0.19

WLAN 5G 11ac80 UNII-2C

14.65

14.62

0.03

WLAN 5G 11ac80 UNII-3

14.63

14.51

0.12

GSM850

32.40

32.17

0.23

GSM1900

28.89

28.73

0.16

WCDMA B2

23.17

23.02

0.15

WCDMA B5

23.16

23.00

0.16

LTE B2

22.79

22.63

0.16

LTE B7

23.54

23.38

0.16

LTE B7 CA

21.45

21.33

0.12

LTE B5/26(Part22H)

23.25

23.05

0.20

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 9 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

LTE B26(Part90S)

23.21

23.10

0.11

LTE B42

22.86

22.75

0.11

5G NR n5

23.76

23.47

0.29

5G NR n7

23.42

23.25

0.17

5G NR n26(Part22H)

23.65

23.51

0.14

5G NR n26(Part90S)

23.68

23.49

0.19

5G NR n38

23.99

23.58

0.41

5G NR n41

23.53

23.41

0.12

Test Item
Radiated Spurious Emission (dBm)

Mode
GSM1900 WCDMA B2 LTE B2 LTE B7

Test Item

Mode

Field Strength (dBuV/m)

NFC 13.56MHz

IHDT56AQ1 Parent
Worst Result -53.66 -53.85 -54.05 -61.50
IHDT56AQ1 Parent
Worst Result
54.32

IHDT56AQ2 Variant
Check Result -53.49 -53.63 -53.62 -61.38
IHDT56AQ2 Variant
Check Result
54.68

Difference (dB) -0.17 -0.22 -0.43 -0.12
Difference (dB)
-0.36

Conclusion: Radiated spurious emission test against the variant model based on the worst-case condition from the original model was performed in this filing to demonstrate the test data from original model remains representative for the variant model.

Based on the spot check test result, the test data from the original model is representative for the variant model. The power level and RSE spot check are shown within expected level compliant to limit line.

We are using power and ERP/EIRP measurements from the original parent model reports to list on the grant.

The same DFS detection is used in the variant. Hence, there is no spot check data for DFS.

We confirm that the test data reuse policy of FCC KDB 484596 D01 Referencing Test Data v01 has been followed and the test data as referenced from the parent model report represents compliance with new FCC ID.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 10 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

3 List of Measuring Equipment

Instrument
Spectrum Analyzer Pulse Power
Senor
Power Meter
Power divider
EXA Spectrum Analyzer
Loop Antenna

Manufacturer R&S
Anritsu Anritsu
STI Keysight

Model No. FSV40
MA2411B ML2495A STI08-0055 N9010B

Calibration Serial No. Characteristics
Date

Test Date

Due Date

101040

10Hz~40GHz

Oct. 11, 2023

Oct. 19, 2023~ Oct. 30, 2023

Oct. 10, 2024

0917070

300MHz~40GH z

Jan. 05, 2023

Oct. 19, 2023~ Oct. 30, 2023

Jan. 04, 2024

1005002

50MHz Bandwidth

Jan. 05, 2023

Oct. 19, 2023~ Oct. 30, 2023

Jan. 04, 2024

-

0.5~40GHz

NCR

Oct. 19, 2023~ Oct. 30, 2023

NCR

MY574710 10Hz-44G,MAX

79

30dB

Oct. 10, 2023

Oct. 20, 2023

Oct. 09, 2024

R&S

HFH2-Z2E 101125 9kHz~30MHz Sep. 11 2023 Oct. 20, 2023 Sep. 10, 2024

Bilog Antenna

TeseQ

CBL6111D 49922 30MHz-1GHz Apr. 09, 2023 Oct. 20, 2023 Apr. 08, 2024

Horn Antenna Schwarzbeck BBHA9120D 1284 1GHz~18GHz Oct. 10, 2023 Oct. 20, 2023 Oct. 09, 2024

SHF-EHF Horn Com-power

AH-840

101070 18GHz~40GHz Jan. 08, 2023 Oct. 20, 2023 Jan. 07, 2024

Amplifier

SONOMA

Amplifier

MITEQ

high gain Amplifier

EM

Amplifier

Agilent

AC Power Source Chroma

Turn Table

ChamPro

310N

380827

EM18G40GG A

060728

EM01G18GA 060840

8449B 61601

3008A023 70
F1040900 04

EM 1000-T 060762-T

9KHz-1GHz 18~40GHz 1Ghz-18Ghz 1Ghz-18Ghz
N/A 0~360 degree

Jul. 06, 2023 Oct. 20, 2023 Jul. 05, 2024

Jan. 05, 2023 Oct. 20, 2023 Jan. 04, 2024

Oct. 10, 2023 Oct. 20, 2023 Oct. 09, 2024

Oct. 10, 2023 Oct. 20, 2023 Oct. 09, 2024

NCR

Oct. 20, 2023

NCR

NCR

Oct. 20, 2023

NCR

Antenna Mast

ChamPro

EMI Test Receiver

R&S

Bilog Antenna

TeseQ

EM 1000-A ESR7
CBL6111D

060762-A 1 m~4 m

NCR

Oct. 20, 2023

NCR

101403

9kHz~7GHz;Ma x 30dBm

Oct. 10, 2023

Nov. 01, 2023

Oct. 09, 2024

44483 30MHz-1GHz Dec. 23, 2022 Nov. 01, 2023 Dec. 22, 2023

Amplifier

SONOMA

AC Power Source Chroma

Turn Table

MF

310N 61601 MF7802

380826 9KHz-1GHz

616010002 473

N/A

N/A

0~360 degree

Jul. 06, 2023 Nov. 01, 2023 Jul. 05, 2024

NCR

Nov. 01, 2023

NCR

NCR

Nov. 01, 2023

NCR

Antenna Mast

MF

MF7802

N/A

1 m~4 m

NCR

Nov. 01, 2023

NCR

Remark
Conducted (TH01-KS) Conducted (TH01-KS) Conducted (TH01-KS) Conducted (TH01-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) Radiation (03CH02-KS)

NCR: No Calibration Required.

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 11 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0

FCC RF Test Report

Report No. : 392114-01

4 Measurement Uncertainty
The measurement uncertainties shown below were calculated in accordance with the requirements of ANSI 63.26-2015. All the measurement uncertainty value were shown with a coverage K=2 to indicate 95% level of confidence. The measurement data show herein meets or exceeds the CISPR measurement uncertainty values specified in CISPR 16-4-2 and can be compared directly to specified limit to determine compliance.

Uncertainty of Conducted Measurement Test Item
Conducted Power

Uncertainty ±0.46 dB

Uncertainty of Radiated Emission Measurement (9 kHz ~ 30 MHz)
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

3.30 dB

Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz)

Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

3.82dB

Uncertainty of Radiated Emission Measurement (1 GHz ~ 18 GHz)
Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

3.56dB

Uncertainty of Radiated Emission Measurement (18 GHz ~ 40 GHz)

Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y))

3.54dB

-THE END-

Sporton International Inc. (Kunshan) TEL : +86-512-57900158

Page Number

: 12 of 12

Report Issued Date : Nov. 06, 2023

Report Version

: Rev. 01

Report Template No.: SCE Version 1.0


Microsoft Word 2019 Microsoft Word 2019