Motorola Mobility LLC T56AQ2 Mobile Cellular Phone IHDT56AQ2 IHDT56AQ2 t56aq2
FCC RF Test Report Report No. : 392114-01 Spot Check Evaluation APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID STANDARD : Motorola Mobility LLC : Mobile Cellular Phone : Motorola : XT2363-3 : IHDT56AQ2 : 47 CFR Part 2, 22(H), 24(E), 27(M), 27(Q), 90(S) 47 CFR Part 15 Subpart C §15.225 47 CFR Part 15 Subpart C §15.247 47 CFR Part 15 Subpart E §15.407 We, Sporton International Inc. (Kunshan), would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval of Sporton International Inc. (Kunshan), the test report shall not be reproduced except in full. Approved by: Jason Jia Sporton International Inc. (Kunshan) No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 1 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 TABLE OF CONTENTS REVISION HISTORY..........................................................................................................................................3 1 GENERAL DESCRIPTION..........................................................................................................................4 1.1 Applicant ............................................................................................................................................ 4 1.2 Manufacturer......................................................................................................................................4 1.3 Product Feature of Equipment Under Test........................................................................................4 1.4 Modification of EUT ........................................................................................................................... 4 1.5 Testing Site ........................................................................................................................................ 5 1.6 Test Software.....................................................................................................................................5 1.7 Applicable Standards.........................................................................................................................5 1.8 Specification of Accessory.................................................................................................................6 2 RE-USE OF MEASURED DATA.................................................................................................................7 2.1 Introduction Section ........................................................................................................................... 7 2.2 Model Difference Information ............................................................................................................ 7 2.3 Reference detail Section: .................................................................................................................. 8 2.4 Spot Check Verification Data Section................................................................................................9 3 LIST OF MEASURING EQUIPMENT........................................................................................................11 4 MEASUREMENT UNCERTAINTY ............................................................................................................12 APPENDIX A. SETUP PHOTOGRAPHS Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 2 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report REVISION HISTORY REPORT NO. 392114-01 VERSION DESCRIPTION Rev. 01 Initial issue of report Report No. : 392114-01 ISSUED DATE Nov. 06, 2023 Conformity Assessment Condition: 1. The test results (PASS/FAIL) with all measurement uncertainty excluded are presented against the regulation limits or in accordance with the requirements stipulated by the applicant/manufacturer who shall bear all the risks of non-compliance that may potentially occur if measurement uncertainty is taken into account. 2. The measurement uncertainty please refer to each test result in the section "Measurement Uncertainty" Disclaimer: The product specifications of the EUT presented in the test report that may affect the test assessments are declared by the manufacturer who shall take full responsibility for the authenticity. Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 3 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 1 General Description 1.1 Applicant Motorola Mobility LLC 222 W,Merchandise Mart Plaza, Chicago IL 60654 USA 1.2 Manufacturer Motorola Mobility LLC 222 W,Merchandise Mart Plaza, Chicago IL 60654 USA 1.3 Product Feature of Equipment Under Test Product Feature Equipment Mobile Cellular Phone Brand Name Motorola Model Name XT2363-3 FCC ID IHDT56AQ2 IMEI Code Conducted: 352643330023178/352643330023186 Radiation: 352643330019572/352643330019580 HW Version DVT2 SW Version UUG34.30 EUT Stage Identical Prototype Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications or user's manual for more detailed description. 1.4 Modification of EUT No modifications are made to the EUT during all test items. Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 4 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 1.5 Testing Site Sporton International Inc. (Kunshan) is accredited to ISO/IEC 17025:2017 by American Association for Laboratory Accreditation with Certificate Number 5145.02. Test Firm Sporton International Inc. (Kunshan) Test Site Location No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China TEL : +86-512-57900158 Test Site No. Sporton Site No. 03CH02-KS 03CH04-KS TH01-KS FCC Designation No. CN1257 FCC Test Firm Registration No. 314309 1.6 Test Software Item 1. Site TH01-KS 2. TH01-KS 3. TH01-KS 4. TH01-KS 5. TH01-KS 6. 03CH02-KS 7. 03CH04-KS Manufacturer SPORTON SPORTON SPORTON SPORTON SPORTON AUDIX AUDIX Name FCC 15C-15E Test Tools Ver10.0_210607 FCC BT2.0 Ver3.0_For_CHINA_190111 FCC LTE_Ver2.0 Auto_china_210503 Part2224_Ver5.0 200330 FCC_5GNR_China_201027 E3 E3 Version 10.0 3.0 2.0 5.0 1.0 6.2009-8-24al 210616 1.7 Applicable Standards According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: FCC KDB 484596 D01 Referencing Test Data v01 47 CFR Part 2, 22(H), 24(E), 27(M), 27(Q), 90(S) 47 CFR Part 15 Subpart C §15.225 47 CFR Part 15 Subpart C §15.247 47 CFR Part 15 Subpart E §15.407 ANSI C63.10-2013 ANSI C63.26-2015 Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 5 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 1.8 Specification of Accessory AC Adapter 1(US) AC Adapter 1(EU) AC Adapter 1(UK) AC Adapter 1(AU) AC Adapter 1(AR) AC Adapter 1(IN) AC Adapter 2(US) AC Adapter 2(EU) AC Adapter 2(UK) AC Adapter 2(AU) AC Adapter 2(AR) AC Adapter 2(BR) AC Adapter 2(Chile) AC Adapter 3(BR) AC Adapter 4(BR local) AC Adapter 5(IN local) Battery 1 Battery 2 Battery 3 USB Cable 1 USB Cable 2 USB Cable 3 Specification of Accessory Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Chenyang) Model Name Brand Name Motorola (Cliptech) Model Name Brand Name Motorola (XIHI) Model Name Brand Name Motorola (ATL) Model Name Brand Name Motorola (SCUD) Model Name Brand Name Motorola (Sunwoda) Model Name Brand Name Motorola (Saibao) Model Name Brand Name Motorola (Juwei ) Model Name Brand Name Motorola (Washin) Model Name MC-201L MC-202L MC-203L MC-205L MC-206L MC-204 MC-201L MC-202L MC-203L MC-205L MC-206L MC-207L MC-209L MC-207L MC-207L MC-204 QF50 QF50 QF50 SZN-A026A JWUB1606-ZN01H HX-ZN-19 Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 6 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 2 Re-use of Measured Data 2.1 Introduction Section This application re-uses data collected on a similar device. The subject device of this application (Model: XT2363-3, FCC ID: IHDT56AQ2) is electrically identical to the reference device (Model: XT2363-2, XT2363-1, FCC ID: IHDT56AQ1) for the portions of the circuitry corresponding to the data being re-used. Based on their similarity, the FCC Part 15C (equipment class: DTS, DSS, DXX) and FCC Part 15E (equipment class: NII) and FCC Part 22, 24, 27, 90 (equipment class: PCE) reuse the original model's result and do spot-check, following the FCC KDB 484596 D01 Referencing Test Data v01. The applicant takes full responsibility that the test data as referenced in this report represent compliance for this FCC ID: IHDT56AQ2 . 2.2 Model Difference Information The main difference between FCC ID: IHDT56AQ1 and FCC ID: IHDT56AQ2 is as below: · Remove WCDMA IV, LTE B4/12/13/17/25/66 and 5G NR n2/n66. · Add LTE B20/32 and 5G NR n8/n20/n77. Other differences and all the details of similarity and difference can be found in the confidential documents (XT2363-3_Operational Description of Product Equality Declaration). Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 7 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 2.3 Reference detail Section: Rule Equipment Part Class DSS (BR/EDR) DTS (BLE) 15C DTS (WLAN) DXX (NFC) Frequency Band (MHz) 2400~2483.5 2400~2483.5 2400~2483.5 13.56 5180~5240 15E U-NII 5260~5320 5500~5720 PCE (GSM) PCE (WCDMA) 22, PCE 24, (LTE) 27, PCE 90 (LTE) PCE (LTE) PCE (NR) 5745~5825 GSM 850/1900 Band II, V B2/5/7/26 ULCA 7C B26 (90S) B42 (Part27Q) n5/n7/n26/n38/n41 Reference FCC ID (Parent) IHDT56AQ1 Type Grant/ Permissive Change Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant IHDT56AQ1 Original Grant Reference Title FR392114A FR392114B FR392114C FR392114D FR392114E FR392114E FZ392114 FR392114E FZ392114 FR392114E FG392114A FG392114A FG392114B FG392114C FG392114D FG392114E FG392114G FCC ID Filling (Variant) IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 IHDT56AQ2 Report Title/Section All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 8 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 2.4 Spot Check Verification Data Section Conducted power test and radiated spurious emission test against the variant model based on the worst-case condition from the original model was performed in this filing to demonstrate the test data from original model remains representative for the variant model. All test procedures follow the related section of parent report. Summary for power and RSE spot check for each rule entry and technology is listed as below: Test Item Mode IHDT56AQ1 Parent Worst mode Test Result IHDT56AQ2 Variant Check Test Result Difference (dB) BT BR/EDR 17.22 16.21 1.01 BLE 1M 10.43 10.39 0.04 BLE 2M 10.64 10.61 0.03 WLAN 2.4G 11b 21.66 21.41 0.25 WLAN 2.4G 11g 23.43 23.39 0.04 WLAN 2.4G 11n20 23.43 23.28 0.15 WLAN 2.4G 11n40 22.37 22.24 0.13 WLAN 5G 11a UNII-1 18.19 18.11 0.08 WLAN 5G 11a UNII-2A 18.65 18.57 0.08 WLAN 5G 11a UNII-2C 18.66 18.41 0.25 WLAN 5G 11a UNII-3 18.59 18.31 0.28 WLAN 5G 11n20 UNII-1 17.99 17.95 0.04 WLAN 5G 11n20 UNII-2A 18.50 18.42 0.08 WLAN 5G 11n20 UNII-2C 18.55 18.23 0.32 WLAN 5G 11n20 UNII-3 18.49 18.28 0.21 WLAN 5G 11n40 UNII-1 16.48 16.46 0.02 WLAN 5G 11n40 UNII-2A 16.89 16.83 0.06 WLAN 5G 11n40 UNII-2C 16.93 16.53 0.40 Conducted WLAN 5G 11n40 UNII-3 16.78 16.56 0.22 Power WLAN 5G 11ac20 UNII-1 18.00 17.88 0.12 (dBm) WLAN 5G 11ac20 UNII-2A 18.51 18.29 0.22 WLAN 5G 11ac20 UNII-2C 18.56 18.17 0.39 WLAN 5G 11ac20 UNII-3 18.50 18.13 0.37 WLAN 5G 11ac40 UNII-1 15.59 15.54 0.05 WLAN 5G 11ac40 UNII-2A 15.99 15.94 0.05 WLAN 5G 11ac40 UNII-2C 15.99 15.82 0.17 WLAN 5G 11ac40 UNII-3 15.96 15.59 0.37 WLAN 5G 11ac80 UNII-1 12.71 12.61 0.10 WLAN 5G 11ac80 UNII-2A 13.83 13.64 0.19 WLAN 5G 11ac80 UNII-2C 14.65 14.62 0.03 WLAN 5G 11ac80 UNII-3 14.63 14.51 0.12 GSM850 32.40 32.17 0.23 GSM1900 28.89 28.73 0.16 WCDMA B2 23.17 23.02 0.15 WCDMA B5 23.16 23.00 0.16 LTE B2 22.79 22.63 0.16 LTE B7 23.54 23.38 0.16 LTE B7 CA 21.45 21.33 0.12 LTE B5/26(Part22H) 23.25 23.05 0.20 Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 9 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 LTE B26(Part90S) 23.21 23.10 0.11 LTE B42 22.86 22.75 0.11 5G NR n5 23.76 23.47 0.29 5G NR n7 23.42 23.25 0.17 5G NR n26(Part22H) 23.65 23.51 0.14 5G NR n26(Part90S) 23.68 23.49 0.19 5G NR n38 23.99 23.58 0.41 5G NR n41 23.53 23.41 0.12 Test Item Radiated Spurious Emission (dBm) Mode GSM1900 WCDMA B2 LTE B2 LTE B7 Test Item Mode Field Strength (dBuV/m) NFC 13.56MHz IHDT56AQ1 Parent Worst Result -53.66 -53.85 -54.05 -61.50 IHDT56AQ1 Parent Worst Result 54.32 IHDT56AQ2 Variant Check Result -53.49 -53.63 -53.62 -61.38 IHDT56AQ2 Variant Check Result 54.68 Difference (dB) -0.17 -0.22 -0.43 -0.12 Difference (dB) -0.36 Conclusion: Radiated spurious emission test against the variant model based on the worst-case condition from the original model was performed in this filing to demonstrate the test data from original model remains representative for the variant model. Based on the spot check test result, the test data from the original model is representative for the variant model. The power level and RSE spot check are shown within expected level compliant to limit line. We are using power and ERP/EIRP measurements from the original parent model reports to list on the grant. The same DFS detection is used in the variant. Hence, there is no spot check data for DFS. We confirm that the test data reuse policy of FCC KDB 484596 D01 Referencing Test Data v01 has been followed and the test data as referenced from the parent model report represents compliance with new FCC ID. Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 10 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 3 List of Measuring Equipment Instrument Spectrum Analyzer Pulse Power Senor Power Meter Power divider EXA Spectrum Analyzer Loop Antenna Manufacturer R&S Anritsu Anritsu STI Keysight Model No. FSV40 MA2411B ML2495A STI08-0055 N9010B Calibration Serial No. Characteristics Date Test Date Due Date 101040 10Hz~40GHz Oct. 11, 2023 Oct. 19, 2023~ Oct. 30, 2023 Oct. 10, 2024 0917070 300MHz~40GH z Jan. 05, 2023 Oct. 19, 2023~ Oct. 30, 2023 Jan. 04, 2024 1005002 50MHz Bandwidth Jan. 05, 2023 Oct. 19, 2023~ Oct. 30, 2023 Jan. 04, 2024 - 0.5~40GHz NCR Oct. 19, 2023~ Oct. 30, 2023 NCR MY574710 10Hz-44G,MAX 79 30dB Oct. 10, 2023 Oct. 20, 2023 Oct. 09, 2024 R&S HFH2-Z2E 101125 9kHz~30MHz Sep. 11 2023 Oct. 20, 2023 Sep. 10, 2024 Bilog Antenna TeseQ CBL6111D 49922 30MHz-1GHz Apr. 09, 2023 Oct. 20, 2023 Apr. 08, 2024 Horn Antenna Schwarzbeck BBHA9120D 1284 1GHz~18GHz Oct. 10, 2023 Oct. 20, 2023 Oct. 09, 2024 SHF-EHF Horn Com-power AH-840 101070 18GHz~40GHz Jan. 08, 2023 Oct. 20, 2023 Jan. 07, 2024 Amplifier SONOMA Amplifier MITEQ high gain Amplifier EM Amplifier Agilent AC Power Source Chroma Turn Table ChamPro 310N 380827 EM18G40GG A 060728 EM01G18GA 060840 8449B 61601 3008A023 70 F1040900 04 EM 1000-T 060762-T 9KHz-1GHz 18~40GHz 1Ghz-18Ghz 1Ghz-18Ghz N/A 0~360 degree Jul. 06, 2023 Oct. 20, 2023 Jul. 05, 2024 Jan. 05, 2023 Oct. 20, 2023 Jan. 04, 2024 Oct. 10, 2023 Oct. 20, 2023 Oct. 09, 2024 Oct. 10, 2023 Oct. 20, 2023 Oct. 09, 2024 NCR Oct. 20, 2023 NCR NCR Oct. 20, 2023 NCR Antenna Mast ChamPro EMI Test Receiver R&S Bilog Antenna TeseQ EM 1000-A ESR7 CBL6111D 060762-A 1 m~4 m NCR Oct. 20, 2023 NCR 101403 9kHz~7GHz;Ma x 30dBm Oct. 10, 2023 Nov. 01, 2023 Oct. 09, 2024 44483 30MHz-1GHz Dec. 23, 2022 Nov. 01, 2023 Dec. 22, 2023 Amplifier SONOMA AC Power Source Chroma Turn Table MF 310N 61601 MF7802 380826 9KHz-1GHz 616010002 473 N/A N/A 0~360 degree Jul. 06, 2023 Nov. 01, 2023 Jul. 05, 2024 NCR Nov. 01, 2023 NCR NCR Nov. 01, 2023 NCR Antenna Mast MF MF7802 N/A 1 m~4 m NCR Nov. 01, 2023 NCR Remark Conducted (TH01-KS) Conducted (TH01-KS) Conducted (TH01-KS) Conducted (TH01-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) Radiation (03CH02-KS) NCR: No Calibration Required. Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 11 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 392114-01 4 Measurement Uncertainty The measurement uncertainties shown below were calculated in accordance with the requirements of ANSI 63.26-2015. All the measurement uncertainty value were shown with a coverage K=2 to indicate 95% level of confidence. The measurement data show herein meets or exceeds the CISPR measurement uncertainty values specified in CISPR 16-4-2 and can be compared directly to specified limit to determine compliance. Uncertainty of Conducted Measurement Test Item Conducted Power Uncertainty ±0.46 dB Uncertainty of Radiated Emission Measurement (9 kHz ~ 30 MHz) Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) 3.30 dB Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz) Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) 3.82dB Uncertainty of Radiated Emission Measurement (1 GHz ~ 18 GHz) Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) 3.56dB Uncertainty of Radiated Emission Measurement (18 GHz ~ 40 GHz) Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) 3.54dB -THE END- Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 12 of 12 Report Issued Date : Nov. 06, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0Microsoft Word 2019 Microsoft Word 2019