R. STAHL 9180/21-77-11s Resistance Temperature Detector Isolating Transducer

Article No.: 160502

Product Overview

The R. STAHL 9180/21-77-11s is an Ex i resistance transducer for the intrinsically safe operation of resistance thermometers of type Pt100 (9180/.0) or Pt1000 (9180/.1). The resistance measured at the input is transferred to the output and can thus be measured by an I/O card. Auxiliary power, output, and intrinsically safe input are galvanically isolated.

Technical Data

Explosion Protection

ParameterValue
Explosion Protection (Zones)2
Ex Interface Zone0, 1, 2, 20, 21, 22
IECEx Certification GasIECEx BVS 10.0055 X
IECEx Gas Explosion ProtectionEx ec nC [ia Ga] IIC T4 Gc
IECEx Certification DustIECEx BVS 10.0055 X
IECEx Dust Explosion Protection[Ex ia Da] IIIC
ATEX Certification GasBVS 05 ATEX E 176 X
ATEX Gas Explosion ProtectionII 3 (1) G Ex ec nC [ia Ga] IIC T4 Gc
ATEX Certification DustBVS 05 ATEX E 176 X
ATEX Dust Explosion ProtectionII (1) D [Ex ia Da] IIIC
FMus CertificationFM16US0122X
cFM CertificationFM16CA0067X
cFM MarkingClass I, Div. 2, Groups A,B,C,D;
Class I, Zone 2, AEx/Ex nA nC Group IIC
AIS Class I,II,III, Div. 1, Groups A,B,C,D,E,F,G;
Class I, Zone 0, [AEx ia]/[Ex ia] IIC
T4 at Ta = 70°C
CertificationsSee Doc. 9180 6 031 001 1
ATEX (BVS), Brasilien (ULB), IECEx (BVS), Indien (PESO), Kanada (FM), Korea (KTL), USA (FM), Volksrepublik China (NEPSI)
Marine ApprovalCCS, EU RO MR (DNV)
Conformity DeclarationsATEX (EUK), Volksrepublik China (CCC)

Safety Data

ParameterValue
Maximum Voltage Ui6.5 V
Maximum Current Ii16.5 mA
Maximum Power Pi27 mW
Max. permissible external capacitance Co for IIC25 μF
Max. permissible external inductance Lo for IIC120 mH
Max. permissible external capacitance Co for IIB570 μF
Max. permissible external inductance Lo for IIB450 mH
Max. permissible external capacitance Co for IIIC570 μF
Max. permissible external inductance Lo for IIIC450 mH
Internal Capacitance CiNegligible
Internal Inductance LiNegligible
Safety technical voltage max.253 V
Intrinsically safe limits Inductance Lo/Capacitance CoCommonly connectable Inductance Lo/Capacitance Co
IIC Inductance Lo [mH]50, 5, 1, 0.200
IIC Capacitance Co [μF]1,100, 1,700, 2,300, 3,400
IIB Inductance Lo [mH]100, 20, 2, 0.500
IIB Capacitance Co [μF]5,300, 6,900, 11, 1,500
IIIC Inductance Lo [mH]100, 20, 2, 0.500
IIIC Capacitance Co [μF]5,300, 6,900, 11, 1,500

Electrical Data

ParameterValue
Number of Channels2
LFD RelaysYes
Measuring Range180 ... 3910 Ω
Auxiliary Power
Nominal Voltage24 V DC
Auxiliary Power Voltage Range18 ... 31.2 V
Residual Ripple Voltage Range≤ 3.6 VSS
Nominal Current37 mA
Power Consumption0.89 W
Max. Power Dissipation0.72 W
Reverse Polarity ProtectionYes
Undervoltage MonitoringYes
Operation IndicatorGreen LED "PWR"

Galvanic Isolation

ParameterValue
Test Voltage per StandardEN IEC 60079-11
Ex i Input to Output1.5 kV AC
Ex i Input to Auxiliary Power1.5 kV AC
Ex i Input to Fault Signal Contact1.5 kV AC
Test Voltage per StandardEN 50178
Output to Auxiliary Power350 V AC
Output to Output350 V AC
Fault Signal Contact to Auxiliary Power350 V AC
Fault Signal Contact to Output350 V AC

Input

ParameterValue
Sensor SettingDIP Switch
Resolution0.2 Ω
Input Resistance Temperature DetectorPt 1000
Connection Type RTD Input2-, 3-, 4-wire circuit
2-wire Calibration Settingvia DIP Switch ADJ
RTD Current200 uA ... 0.5 mA
Max. Line Resistance per Wire RTD50 Ω (2-wire circuit) / 100 Ω (3-, 4-wire circuit)

Output

ParameterValue
Output SignalSame as input signal (resistance value)
Connection Type RTD Output2-, 3-, 4-wire circuit
Output Settling Time< 10 ms
Output Response Time< 1 s
Current Source Range200 uA ... 0.5 mA
Switch Setting Line Faultenabled / disabled
Wire Break Detection Input> 3940 Ω
Short Circuit Detection Input< 160 Ω
Output Behavior on Line Fault> 10 kΩ
Line Fault IndicatorRed LED "LF"
Switching Capacity Fault Signal Contact30 V / 100 mA
Fault Message and Auxiliary Power FailureContact (30 V / 100 mA), closed to ground in case of fault
Deviations / Error IndicationBus-Bus, potential-free contact (30 V / 100 mA)
Mean Measurement ErrorValues in % of measuring span (20 mA) at Un, 23 °C
Temperature Influence< 0.1% / 10K

Environmental Conditions

ParameterValue
Ambient Temperature (Single Device)-20 °C ... +70 °C (-4°F ... +158°F)
Ambient Temperature (Group Mounting)-20 °C ... +60 °C (-4°F ... +140°F)
Ambient Temperature (Note)Installation conditions influence ambient temperature. Please refer to "Installation Manual Control Cabinet".
Storage Temperature-40 °C ... +80 °C (-40°F ... +176°F)
Maximum Relative Humidity95%
Max. Relative Humidity (Additional)No condensation
Usage at Altitude< 2000 m
Overvoltage CategoryII
Pollution Degree2
Electromagnetic CompatibilityTested according to the following standards and regulations: EN 61326-1 Use in industrial areas; NAMUR NE 21

Mechanical Data

ParameterValue
Enclosure Type (IP)IP30
Enclosure Type (IP) TerminalsIP20
Flammability Rating (UL 94)VO
Housing MaterialPolyamide
Connection Cross-Section0.2-2.5 mm² flexible / 0.25-2.5 mm² flexible with ferrule / 0.2-2.5 mm² solid
Module Width17.6 mm (0.69 in)
Height114.5 mm (4.51 in)
Depth108 mm (4.25 in)
Installation Depth (Zoll)4.51 in
Weight180 g (0.4 lb)

Mounting / Installation

ParameterValue
Mounting TypeDIN rail NS35/15, NS35/7.5
Mounting PositionVertical / Horizontal
Connection TypeScrew terminal
Conductor Cross-Section Solid Min.0.2 mm²
Conductor Cross-Section Solid Max.2.5 mm²
Conductor Cross-Section Flexible Min.0.2 mm²
Conductor Cross-Section Flexible Max.2.5 mm²
Connection Cross-Section AWG24 ... 14

Technical Drawing - Subject to change

Ex - Area

Field Device

Safe Area

Dimensional Drawing (all dimensions in mm [inch]) - Subject to change

[Diagram showing dimensions of the device and its components]

ISpac Series 9143, 9146, 9147, 9160, 9162, 9163, 9165, 9167, 9170, 9172, 9175, 9176, 9180, 9182, 9193, ISbus Series 9412 with screw terminal

Accessories

DescriptionArticle No.
Clear Cover
for ISpac Module 91xx
Yellow, transparent
For clear identification of the device for SIL applications.
(Packaging unit: 10 pieces)
200914

Spare Parts

DescriptionArticle No.
3-pole connector, screw terminal
Screw thread: M3
Stripping length: 7 mm
Color: Black
112816
3-pole connector, screw terminal
Screw thread: M3
Stripping length: 7 mm
Color: Blue
112818
3-pole connector, screw terminal
Screw thread: M3
Stripping length: 7 mm
Color: Green
112817
3-pole connector with test socket, screw terminal
Screw thread: M3
Stripping length: 7 mm
Color: Blue
113004
3-pole connector with test socket, screw terminal
Screw thread: M3
Stripping length: 7 mm
Color: Black
113005

Changes to technical data, dimensions, weights, designs, and delivery options are reserved. The illustrations are non-binding.

PDF preview unavailable. Download the PDF instead.

ex-ficha-tecnica-individual-repetidor-aislador-resistencia-circuito-de-campo-ex-i-ispac-9180-21-77-11s-160502-de-de-rstahl Adobe PDF Library 17.0

Related Documents

Preview R. STAHL 9180A Series Ex i Resistance Isolator - Technical Data and Specifications
Detailed technical specifications for the R. STAHL 9180A Series Ex i resistance isolator, including explosion protection, technical data, safety data, mechanical data, and accessories. Suitable for Pt100 and Pt1000 resistance temperature detectors in hazardous areas.
Preview R. STAHL 9180/10-77-11s Resistance Temperature Detector Isolating Transducer for Hazardous Areas
Technical specifications and features of the R. STAHL 9180/10-77-11s, an Ex i resistance transducer for Pt100 and Pt1000 resistance thermometers in hazardous areas. Includes explosion protection data, electrical and mechanical specifications, and connection diagrams.
Preview R. STAHL 9180A Ex i Resistance Isolator for Pt100/Pt1000
Technical specifications and data for the R. STAHL 9180A Ex i resistance isolator, designed for intrinsically safe operation of Pt100 and Pt1000 resistance temperature detectors. Features include galvanic isolation, various explosion protection certifications, and detailed electrical and mechanical data.
Preview R. STAHL 9180/21-77-11s Isolator Barrier: Technical Specifications
Detailed technical specifications for the R. STAHL 9180/21-77-11s resistance isolator, including explosion protection, safety data, electrical data, and mechanical data for Ex i field circuits.
Preview R. STAHL 9180/11-77-11s Ex i ISpac Resistance Isolator for Field Circuits
Technical specifications and features of the R. STAHL 9180/11-77-11s Ex i ISpac resistance isolator, designed for intrinsic safety in resistance thermometer circuits.
Preview R. STAHL 9180/11-77-11s: Resistance Signal Conditioner for Hazardous Areas
Detailed technical specifications and features of the R. STAHL 9180/11-77-11s resistance signal conditioner, designed for intrinsically safe field circuits in Ex i applications. Learn about its explosion protection, electrical data, and mechanical properties.
Preview R. STAHL 9180A Series Ex i Resistance Isolator: Technical Specifications
Detailed technical specifications for the R. STAHL 9180A series Ex i field circuit resistance isolator (ISpac), including explosion protection, technical data, input/output specifications, mechanical data, and accessories.
Preview R. STAHL 9180/20-77-11k Ex i Field Circuit Isolator Barrier - Technical Data
Detailed technical specifications and data for the R. STAHL 9180/20-77-11k Ex i field circuit resistance isolator barrier, including explosion protection, safety data, electrical data, input/output specifications, mechanical data, and accessories.