Quick Installation Guide

Use this Quick Installation Guide as a reference to install your Track Light with Monitor. Reference the corresponding Track Light with Monitor Installation Guide for more details and dimensional specifications for the proper installation of this product.

Models Applicable

Applies to Models: 1531017 (-000 thru -008), 1531018 (-010 thru -018), 153963 (-000 thru -008), 153964 (-010 thru -018), 153829 (000 thru -008), 153906 (-010 thru -018), 153830 (-000 thru -008), 153907 (-010 thru -018)

? Equipment Alert: This installation requires at least two service technicians. Track with Light and Monitor weight (max.) is 157 Lbs. (71 kgs).

©2017 Midmark Corp. 60 Vista Drive Versailles, OH 45380 USA | 1.937.526.3662 | 1.800.643.6275 | Document ID: 003-10003-00 Rev. AA8 (3/18/24)

Before You Begin Checklist

Reference the Installation Guide for more detailed information about each of the steps shown in this Quick Installation Guide.

? Equipment Alert: This installation requires at least two service technicians. Track with Light and Monitor weight (max.) is 157 Lbs. (71 kgs).

Step 1: Mount the Track Assembly on the Ceiling

Use all six lag bolts and washers provided to mount the track assembly.

Diagram Description (Step 1): Depicts mounting a ceiling track. Key labels include "Head End", "End", "Right Side", "Left Side", and "Video Input Source Box". The diagram shows "6 Lag Bolts & Washers" being used for mounting. A dimension is indicated as "91\" from end cap to end cap".
? Equipment Alert: Leave the plastic wrap on the trolleys while mounting the track to prevent trolleys from rolling up and down the track.
? Equipment Alert: Support for the assembly during installation is essential. The Track Monitor/Trolley Assembly weighs approximately 75 lbs. and needs to be fully supported at ceiling height until all 6 lag bolts are securely anchored into support studs.
? Equipment Alert: Do not connect this product to a wall mounted light switch. If you must use a wall mounted light switch, it must be contained with a locked cover. Refer to installation manual for details.

Step 2: Connect Power, Video Source Cables and the Monitor Power Supply at the foot end of the chair

❗ WARNING: Turn OFF the Facility power to this circuit at the Electrical Control Panel before wiring the power to this unit.

Remove the cover on the video input source box (four screws). Remove the power source supply (two nuts). Connect the monitor power supply, facility power, and video source cables.

Diagram Description (Step 2): Illustrates electrical connections at the "Foot End". Components labeled include "Facility Power", "Video Input Source Connections", "Monitor Power Supply 19 VDC", "21.5\" Monitor Power Supply 24 VDC", "17\" Monitor Power Supply", "Grounds", and "21.5\" Track Video Connections". A box indicates to "Remove Cover".

Step 3: Install the Light and Monitor Down Tubes

❗ WARNING: The locking pin screw and set screws should only be installed after the down tube has been mounted and is hanging freely from the trolley. If the locking pin screw cannot be threaded into the trolley casting with the down tube mounted, it can indicate there is an error in the setup.

Align Monitor Tube Locking Pin screw holes with the track. Insert the tube into the trolley and rotate the tube while gently pressing upward. You will feel the pin engage the tube groove and the tube slide upward. When you cannot rotate the tube any further (a quarter turn), lower the tube and the tube will hang from the pin. The down tube should hang freely with no support. Install Locking Pin screw (hand tighten) and 1/2" long set screws in the Monitor Trolley. Ensure set screws are tightened and the tube is rigid.

Align Light Tube Locking Pin screw holes with the track. Insert the tube into the trolley and rotate the tube while gently pressing upward. You will feel the pin engage the tube groove and the tube slide upward. When you cannot rotate the tube any further (a quarter turn), lower the tube and the tube will hang from the pin. The down tube should hang freely with no support. Install Locking Pin screw (hand tighten) and 1/2" long set screws in the Light Trolley, ensure set screws are tightened and the tube is rigid. If 1/2" long set screws are used they will not contact the tube.

Diagram Description (Step 3): Shows the "Monitor Trolley" and "Light Trolley" mounted on a track. The "Monitor Down Tube" and "Light Down Tube" are depicted. Fasteners are labeled: "Locking Pin Screw (hand tighten)", "Two 1/4\" long set screws" (for monitor), and "Two 1/2\" long set screws" (for light). The "Light Down Tube" is shown as a stub extending to the bottom of the trolley.

Step 4: Attach the Monitor Flex Arm to the Down Tube

  1. Place Monitor Pivot Bearing into the Monitor Down Tube.
  2. Align the flat on the Pivot Bearing with the weldment flat.
  3. Insert Key into Slot, Lower Collar over it and tighten the Set Screw directly over Key in the Slot.
  4. Remove screw slide cover off so you can route the cable through arm to the monitor mount.
  5. Remove Bracket (2 screws) and install Ground Wire in the Flex Arm.
  6. Slide Arm Cover in place, install screw.
  7. Lower Down Tube Cover and install mating Lower Cover onto it.
Diagram Description (Step 4): Illustrates the process of attaching the monitor flex arm to the down tube. Components shown include the "Monitor Down Tube", "Pivot Bearing", "Key", "Collar", "Set Screw", "Cable Path", "Arm Cover", and "Ground Wire". The diagram shows alignment points and the insertion of the key and collar.

Step 5: Attach the Light Flex Arm to the Down Tube

? Equipment Alert: Apply a thin layer of lubricant to the inside of the Light Down Tube and to the outer surface of the bearing shaft.
  1. Connect the Light Cable.
  2. Slip Light Flex Arm into Down Tube.
  3. Align Flex Arm with track, facing head end (set screw hole will be 180° across from it).
  4. Rotate Flex Arm as needed to align nearest two mating Slots then insert Key.
  5. Lower Collar over Key.
  6. Tighten set screw directly over the Key.
Diagram Description (Step 5): Details attaching the light flex arm to the down tube. Components shown are the "Light Down Tube", "Flex Arm", "Collar", "Key", "Set Screw", and "Cable Connection". The diagram indicates alignment with the track and the insertion of the key and collar.

Step 6: Mount Monitor on the Mount Arm Assembly and plug in cables. Install cover. Install Side Rails and End Cap on Track.

? Equipment Alert: Verify the cover fits.

Use four M4x7, 12mm long screws/washers to attach monitor to arm (metric screws are supplied with arm).

Divide cables around mounting plate, loop at the bottom and plug into the Monitor. Attach the Cover to secure cables.

Diagram Description (Step 6): Shows the final assembly steps. This includes mounting the monitor, routing cables around a mounting plate, plugging them into the monitor, and attaching a cover. It also shows the installation of "Side Rails" and an "End Cap" onto the track. A note indicates the "End Cap must be removed to Install Side Rails". The diagram shows using a rubber mallet to tap side rails into place.

Audio / Video Connections

Note: Use only single cables that fit the total installation lengths required. Combining smaller cables will result in poor picture quality.

Basic Setup - Antenna/Cable COAX / DVD Player / Desktop PC

Diagram Description (Basic Setup): Illustrates connecting a Desktop or laptop computer via VGA and 3.5mm Audio Cable, or an Antenna/Cable COAX source, to a monitor. Cables are shown routed from the video source to the ceiling and then down.

Digital Receiver Setup - Digital Receiver / DVD Player / Desktop PC

Diagram Description (Digital Receiver Setup): Shows connecting a Digital Receiver or DVD Player to a monitor. Cables are depicted routed from the video source to the ceiling and then down.

HD Receiver Setup - HD Receiver / DVD Player / Desktop PC

Diagram Description (HD Receiver Setup): Illustrates connecting an HD Receiver or DVD Player to a monitor. Cables are shown routed from the video source to the ceiling and then down.

Minimum Cable Specifications for Optimal Output

Cable TypeSpecifications
VGA CableHD15 male-to-male UXGA cable
Maximum Length 50 feet
Double shielded cable construction
3 internal coax lines for red, green, and blue
Ferrites to protect against EMI/RFI on each end
3.5mm Audio Cable (PC audio)Maximum length 50 feet
Single shielded cable construction
Coax CableRG6 - male-to-male cable
Triple shielded cable construction
HDMI CableHDMI Type A male-to-male cable
HDMI 1.2 or 1.3 compatible
Maximum length 50 feet
Gold plated contacts (shell and pins)
Triple shielded cable construction
24 AWG wire used for twisted pairs
Ferrites to protect against EMI/RFI on each end

Monitor Connections

Diagram Description (Monitor Connections): Depicts typical monitor input ports and power supply connections. Input ports shown include RF, S-VIDEO, CVBS IN, AUDIO IN (R/L), PC IN (VGA), HDMI, and USB. Power supply connections are indicated for DC 19V, DC 24V, and 12V. Different monitor power supply units (17", 19/24", 21.5") are illustrated.
? Equipment Alert: Always connect as shown. Do not leave any visible cables disconnected.
? Equipment Alert: RF connection is not available, this cord will not be used.
? Equipment Alert: This document addresses the Midmark monitor. For non-Midmark monitors, refer to that product's manual to ensure equipment functions safely including proper input voltage and is in proper working condition before use.

Install monitor cover with all cables placed inside.

Models: 1531017, 1531018, 153963, 153964, 153829, 153906, 153830, 153907, 1531017 Track Light with Monitor, 1531017, Track Light with Monitor, Light with Monitor, with Monitor, Monitor

PDF preview unavailable. Download the PDF instead.

003-10003-00 Adobe PDF Library 17.0

Related Documents

Preview IQvitals Zone Quick Reference Guide | Midmark
Concise guide for operating the Midmark IQvitals Zone vital signs monitor, covering setup, blood pressure, SpO2, and temperature measurements, along with procedural hints for accurate patient monitoring.
Preview IQecg 12-Lead Resting ECG Quick Reference Guide
A quick reference guide for performing a 12-lead resting ECG using the IQecg system, detailing patient preparation, lead placement, and operational steps.
Preview Midmark EX6000 Plus ICU Bed: Features and Specifications
Explore the Midmark EX6000 Plus ICU bed, a state-of-the-art medical bed offering advanced features for patient comfort, caregiver convenience, and enhanced mobility. This document details its technical specifications, safety standards, and available accessories.
Preview Midmark Digital Vital Signs Device: Quick Reference Guide and Procedural Hints
A concise guide to operating the Midmark Digital Vital Signs Device, providing step-by-step instructions and procedural hints for blood pressure, SpO2, and temperature measurements.
Preview Midmark 1803C Exam Room Solution: Features and Specifications
Detailed overview of the Midmark 1803C examination table, highlighting its features, specifications, and upholstery options for medical professionals.
Preview Midmark Anesthesia Machine Installation and Specifications
Detailed installation guide and technical specifications for Midmark VMS, VMS Plus, VMC, and VME series anesthesia machines, including safety information, assembly steps, and leak test procedures.
Preview Midmark 175 & 176 Optional Footswitch Installation Instructions
Step-by-step guide for installing the optional footswitch accessory on Midmark Models 175 and 176 medical tables, including wiring diagrams and hardware specifications.
Preview Maximizing Patient Care with Efficient Vital Signs Acquisition
Explore how Midmark's research on vital signs acquisition can improve patient care efficiency, reduce acquisition time, and streamline workflows in healthcare settings.