Product Overview
The HYXIPOWER Hybrid ESS Cabinet is an advanced energy storage solution designed for efficiency, reliability, and user-friendliness. It is available in configurations ranging from 50-125kW inverters, paired with a 215kWh battery capacity.
Key Features
Safe & Reliable
- A-grade cells with automotive-grade standard
- Five-level safety design
- 300m AFCI detection with 0.5s rapid shutdown
- Support for three-phase unbalance output
- IP66 for inverter, IP55 for cabinet
Convenient & User-Friendly
- Compact & Lightweight Design, pre-installed for easy installation
- Flexible parallel connection of cabinets
- App-based quick setup, simple and efficient
Profitable & Efficient
- Innovative liquid cooling technology, extends battery life by 20%
- PV-ESS integrated, lower system cost
- AI dynamic MPPT, boosting power generation by 5%
- DC coupled solution, higher system efficiency
Smart & Manageable
- Three-phase wiring sequence adaptive, easy system wiring
- Support on&off grid switching, suitable for various application scenarios
- Real-time monitoring with OTA for online maintenance
Technical Specifications (Inverters)
Note: When connected to the battery cabinet, the maximum PV input voltage is 650V.
Models: HYX-H50K-ET, HYX-H75K-ET, HYX-H99K9-ET
Parameter | HYX-H50K-ET | HYX-H75K-ET | HYX-H99K9-ET |
---|---|---|---|
DC Input (PV) | |||
Max. Input Voltage | 1,100V | 1,100V | 1,100V |
Rated Input Voltage | 650V | 650V | 650V |
Start-up Voltage | 160V | 160V | 160V |
MPPT Operating Voltage Range | 140V - 1,000V | 140V - 1,000V | 140V - 1,000V |
Max. Input Current per MPPT | 40A | 40A | 40A |
Max. Input Current per String | 20A | 20A | 20A |
Max. Short-circuit Current per MPPT | 50A | 50A | 50A |
Number of MPPT | 4 | 6 | 8 |
Number of Input | 8 | 12 | 16 |
Max. Backfilling Current | 0A | 0A | 0A |
DC Input (Battery) | |||
Rated Input Voltage | 768V | 768V | 768V |
Battery Voltage Range | 600V - 950V | 600V - 950V | 600V - 950V |
Max. Charge/Discharge Current | 80.8A | 121.3A | 161.7A |
AC Output | |||
AC Output Power | 50kW | 75kW | 99.9kW |
Max. Apparent Power | 55kVA | 82.5kVA | 109.9kVA |
Rated Output Voltage | 220/380V, 230/400V | 220/380V, 230/400V | 220/380V, 230/400V |
AC Grid Frequency | 50 / 60Hz | 50 / 60Hz | 50 / 60Hz |
Rated Output Current | 75.9A/380V, 72.1A/400V | 113.9A/380V, 108.2A/400V | 151.9A/380V, 144.3A/400V |
Max. Output Current | 83.5A/380V, 79.4A/400V | 125.3A/380V, 119.0A/400V | 167.1A/380V, 158.7A/400V |
Adjustable Power Factor | > 0.99 / 0.8 leading...0.8 lagging | > 0.99 / 0.8 leading...0.8 lagging | > 0.99 / 0.8 leading...0.8 lagging |
Three Phase Unbalanced Output | 100% Unbalanced Output | 100% Unbalanced Output | 100% Unbalanced Output |
THDi | < 3% | < 3% | < 3% |
Efficiency | |||
Max. Efficiency | 98.5% | 98.5% | 98.5% |
European Weighted Efficiency | 98.0% | 98.0% | 98.0% |
MPPT Efficiency | 99.9% | 99.9% | 99.9% |
Protection | |||
Active Anti-islanding Protection | Yes | Yes | Yes |
Residual Current Monitoring | Yes | Yes | Yes |
DC Reverse Polarity Protection | Yes | Yes | Yes |
DC Switch | Yes | Yes | Yes |
DC Overvoltage Protection | Yes | Yes | Yes |
DC Overcurrent Protection | Yes | Yes | Yes |
AC Overfrequency/Underfrequency Protection | Yes | Yes | Yes |
AC Short-Circuit Protection | Yes | Yes | Yes |
AC Overvoltage Protection | Yes | Yes | Yes |
AC Overcurrent Protection | Yes | Yes | Yes |
DC Surge Protection | Type II | Type II | Type II |
AC Surge Protection | Yes | Yes | Yes |
Ground Fault Detection | Optional | Optional | Optional |
AFCI | Optional | Optional | Optional |
PID Recovery | Optional | Optional | Optional |
General Data | |||
Operating Temperature Range | -30 to + 60°C | -30 to + 60°C | -30 to + 60°C |
Relative Operating Humidity | 0 - 100% RH | 0 - 100% RH | 0 - 100% RH |
Max. Operating Altitude | 4,000m | 4,000m | 4,000m |
Cooling | Smart Air Cooling | Smart Air Cooling | Smart Air Cooling |
Display | LED+APP | LED+APP | LED+APP |
Communication | RS485/4G/WIFI/HPLC | RS485/4G/WIFI/HPLC | RS485/4G/WIFI/HPLC |
Weight | 95kg | 95kg | 95kg |
Dimensions (W*H*D) | 880*760*340mm | 880*760*340mm | 880*760*340mm |
Topology | Non-Isolated | Non-Isolated | Non-Isolated |
Degree of Protection | IP66 | IP66 | IP66 |
Models: HYX-H100K-ET, HYX-H110K-ET, HYX-H125K-ET
Parameter | HYX-H100K-ET | HYX-H110K-ET | HYX-H125K-ET |
---|---|---|---|
DC Input (PV) | |||
Max. Input Voltage | 1,100V | 1,100V | 1,100V |
Rated Input Voltage | 650V | 650V | 650V |
Start-up Voltage | 160V | 160V | 160V |
MPPT Operating Voltage Range | 140V - 1,000V | 140V - 1,000V | 140V - 1,000V |
Max. Input Current per MPPT | 40A | 40A | 40A |
Max. Input Current per String | 20A | 20A | 20A |
Max. Short-circuit Current per MPPT | 50A | 50A | 50A |
Number of MPPT | 8 | 8 | 8 |
Number of Input | 16 | 16 | 16 |
Max. Backfilling Current | 0A | 0A | 0A |
DC Input (Battery) | |||
Rated Input Voltage | 768V | 768V | 768V |
Battery Voltage Range | 600V - 950V | 600V - 950V | 600V - 950V |
Max. Charge/Discharge Current | 161.7A | 177.9A | 183.8A |
AC Output | |||
AC Output Power | 100kW | 110kW | 125kW |
Max. Apparent Power | 110kVA | 121kVA | 125kVA |
Rated Output Voltage | 220/380V, 230/400V | 220/380V, 230/400V | 220/380V, 230/400V |
AC Grid Frequency | 50 / 60Hz | 50 / 60Hz | 50 / 60Hz |
Rated Output Current | 151.9A/380V, 144.3A/400V | 167.1A/380V, 158.7A/400V | 183.8A/380V, 174.6A/400V |
Max. Output Current | 167.1A/380V, 158.7A/400V | 183.8A/380V, 174.6A/400V | 189.9A/380V, 180.4A/400V |
Adjustable Power Factor | > 0.99 / 0.8 leading...0.8 lagging | > 0.99 / 0.8 leading...0.8 lagging | > 0.99 / 0.8 leading...0.8 lagging |
Three Phase Unbalanced Output | 100% Unbalanced Output | 100% Unbalanced Output | 100% Unbalanced Output |
THDi | < 3% | < 3% | < 3% |
Efficiency | |||
Max. Efficiency | 98.5% | 98.5% | 98.5% |
European Weighted Efficiency | 98.0% | 98.0% | 98.0% |
MPPT Efficiency | 99.9% | 99.9% | 99.9% |
Protection | |||
Active Anti-islanding Protection | Yes | Yes | Yes |
Residual Current Monitoring | Yes | Yes | Yes |
DC Reverse Polarity Protection | Yes | Yes | Yes |
DC Switch | Yes | Yes | Yes |
DC Overvoltage Protection | Yes | Yes | Yes |
DC Overcurrent Protection | Yes | Yes | Yes |
AC Overfrequency/Underfrequency Protection | Yes | Yes | Yes |
AC Short-Circuit Protection | Yes | Yes | Yes |
AC Overvoltage Protection | Yes | Yes | Yes |
AC Overcurrent Protection | Yes | Yes | Yes |
DC Surge Protection | Type II | Type II | Type II |
AC Surge Protection | Yes | Yes | Yes |
Ground Fault Detection | Optional | Optional | Optional |
AFCI | Optional | Optional | Optional |
PID Recovery | Optional | Optional | Optional |
General Data | |||
Operating Temperature Range | -30 to + 60°C | -30 to + 60°C | -30 to + 60°C |
Relative Operating Humidity | 0 - 100% RH | 0 - 100% RH | 0 - 100% RH |
Max. Operating Altitude | 4,000m | 4,000m | 4,000m |
Cooling | Smart Air Cooling | Smart Air Cooling | Smart Air Cooling |
Display | LED+APP | LED+APP | LED+APP |
Communication | RS485/4G/WIFI/HPLC | RS485/4G/WIFI/HPLC | RS485/4G/WIFI/HPLC |
Weight | 95kg | 95kg | 95kg |
Dimensions (W*H*D) | 880*760*340mm | 880*760*340mm | 880*760*340mm |
Topology | Non-Isolated | Non-Isolated | Non-Isolated |
Degree of Protection | IP66 | IP66 | IP66 |
Technical Specifications (Battery)
Model: HYX-BOA215
Parameter | HYX-BOA215 |
---|---|
Technical Parameter | |
Battery Type | LiFePO4 |
Battery Module Capacity | 14.336kWh |
Battery Module Nominal Voltage | 51.2V |
Battery Module Qty In Series | 15 |
System Nominal Voltage | 768V |
System Operating Voltage | 672V - 864V |
System Capacity | 215kWh |
Charge/Discharge Current | Recommend: 140A / Maximum: 170A (60s) |
Calendar Life | ≥6000 (25±2°C, 0.5C / 0.5C, 70%EOL) |
General Parameter | |
Operating Temperature Range | Charge: 0 to +55°C / Discharge: -20 to +55°C |
Operating Humidity Range | 0 - 95% RH |
Max. Operating Altitude | <2000m |
Cooling Method | Smart Air Cooling |
Protection Degree | IP54 |
Dimensions (W*H*D) | 1440*2200*1170mm |
Weight | 2700kg |
Communication | CAN |
Installation Location | Outdoor |
Fire Protection Method | Aerosol Fire Suppression |
Networking Mode | WIFI / LAN |