Installation Guide for GE current models including: WOS3PC, 2AS3F-WOS3PC, 2AS3FWOS3PC, WOS3-PC Daintree Wireless Battery Powered Ceiling Mounted Occupancy and Daylight Sensor, WOS3-PC, Daintree Wireless Battery Powered Ceiling Mounted Occupancy and Daylight Sensor, Wireless Battery Powered Ceiling Mounted Occupancy and Daylight Sensor, Battery Powered Ceiling Mounted Occupancy and Daylight Sensor, Ceiling Mounted Occupancy and Daylight Sensor, Mounted Occupancy and Daylight Sensor, Daylight Sensor, DT041
Current Lighting Solutions, LLC WOS3PC 2AS3F-WOS3PC 2AS3FWOS3PC wos3pc
WOS3PC Smart Sensor by Current Lighting Solutions
File Info : application/pdf, 2 Pages, 1.27MB
DocumentDocumentNN WOS3-PC Daintree® Wireless Controls Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor DT041 Daintree® Wireless Controls Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor (WOS3-PC) Installation of Back Plate onto Wall Installation Guide Daintree® Wireless Controls Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor (WOS3-PC) Installation of Device onto Back Plate Product Overview The Daintree® Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor may be deployed in a Daintree EZ Connect or Daintree Networked application. The WOS3-PC device is designed for ceiling installation on suspended ceiling tiles, or to drywall. This device is designed for energy savings based on space occupancy status and ambient light level. The communication with the Daintree system utilizes a secure and reliable wireless connection which helps minimize installation costs and complexity. BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for future use. 1 Counterclockwise rotation to separate the back plate from the device. 2 Remove the insulation sheet. 3 (This step is for installing on wood or cement, if installing on drywall, jump this step.) Drill a hole vertically on the wall. The hole diameter equal to the size of the expansion bolt. 1 Align the device with back plate by positioning hole. 2 Clockwise rotation to install the device onto back plate. Battery Replacement Installation Guide Daintree® Wireless Controls Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor (WOS3-PC) Mask Replacement Installation Guide 1 Put the ring into track, the Lock icon should be 10 degree to the triangle. Then clockwise rotate the ring. 2 When triangle is pointed to the lock icon on the ring IMPORTANT To ensure the product warranty is valid, please ensure all installation instructions and environmental conditions for storage and operation are complied with. Installation to be performed by factory trained or qualified personnel. Save These Instructions Use only in the manner intneded by the manufacturer. If you have any questions, contact the manufacturer. 4 (This step is for installing on wood or cement, if installing on drywall, jump this step.) Insert the expansion bolt into the hole. 5 For installing on drywall, pass the screws through the installing holes on the back plate. For installing on wood or cement, screw should pass the screws and align with the hole drilled in step3. 6 For installing on drywall, lock the screw vertically on the wall. For installing on wood or cement, lock the screw into expansion bolts. 4 Unscrew the screw 5 Remove the cover of battery 6 Remove the elder battery Install new battery. then reverse previous steps to finish the battery replacement. (Only use CR14505 for WOS3-PC) 1 Put the mask into track, the triangle icon on mask is pointed to the triangle icon on body. Then clockwise or counter-clockwise rotate the ring. Product Dimensions 2 When the triangle icon on mask is 90 degree to the triangle icon on body, mask is locked. 2 3 4 Daintree® Wireless Controls Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor (WOS3-PC) Installation Guide Product Operation Button Functionality Reset Button Short Press Double Short Press Hold 5 Seconds Installation Test Mode ON Enable/Disable LED Indicator Reset to Factory default LED Indicator in Red Rapid flash (12 times per second) for up to 30 seconds Solid ON for 10 seconds Flashes once (100ms duration) Flashes ON 2 seconds every 30 seconds Device is trying to join a ZigBee network Device successfully joined a ZigBee network Device has been activated while in the network Batteries need to be replaced LED Indicator in Green Flashes once(100ms duration) Occupancy has been detected 5 Daintree® Wireless Controls Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor (WOS3-PC) Installation Guide Technical Data Product Specifications Dimensions Weight Power Supply Battery Life Operating Environment Status Indicator Mounting Warranty Purpose of Control Construction of Control Type 1 Action Pollution Degree 2 89mm D x 30mm H 81g (without battery) (2) AA 3V battery 10 years (normal operation) -10°C to 40°C (Indoor Use Only) Network join status, Occupancy detected Screw Mounted 5 years Sensor Control Independently Mounted Product Availablity SKU 93149829 DESCRIPTION ARTICLE NO Daintree Wireless Controls Wall Dimmer, In Wall, 2 Button, Battery WWD2-2IW Product Certifications FCC ID: 2AS3F-WOS3PC IC: 25008-WOS3PC The alkaline batteries supplied with your wireless switch are prone to leak over their lifetime, particularly when the battery is mostly depleted. In the event that your battery leaks alkaline into the battery compartment, the chemicals can damage the metal terminals. The chances of this happening can be reduced by changing the batteries in the switch promptly when the batteries are nearing their end of their useful life. If a battery leak should occur, however, it should be cleaned up to prevent damage to the wireless switch. WARNING: THE CHEMICALS LEAKED FROM ALKALINE BATTERIES ARE CORROSIVE. WHEN HANDLING LEAKING BATTERIES, PROPER PERSONAL SAFETY EQUIPMENT SHOULD BE USED, INCLUDING RUBBER GLOVES AND EYE PROTECTION. If it is discovered that the batteries have leaked, wearing rubber gloves and using eye protection, remove all of the batteries from the battery compartment and seal them in a plastic bag. The bag should be discarded in a manner in accordance with local laws and regulations. Then, using a small cloth lightly moistened with vinegar or other mild acid, carefully wipe all of the leaked battery chemicals from inside the battery compartment and allow it to dry. Once dry, the batteries may be replaced and the switch may be reinstalled. 6 Daintree® Wireless Controls Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor (WOS3-PC) Installation Guide Supplier's Declaration of Conformity 47 CFR § 2.1077 Compliance Information Product Name: Wireless Battery-Powered Ceiling Mounted Occupancy and Daylight Sensor Model No: WOS3-PC Supplier's Name: Current Lighting Solutions, LLC Supplier's Website: www.gecurrent.com Supplier's Address (USA): Cleveland, Ohio Supplier's Phone: 1-866-855-8629 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference including interference that may cause undesired operation of the device. L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) L'appareil ne doit pas produire de brouillage; (2) L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC RF Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. ISED RF Radiation Exposure Statement: This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. Pour se conformer aux exigences de conformité CNR 102 RF exposition, une distance de séparation d'au moins 20 cm doit être maintenue entre l'antenne de cet appareil ettoutes les personnes. Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. www.gecurrent.com © 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. DT041-Daintree-WWD2-2IW-Wall-Dimmer-Installation-Guide Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: --Reorient or relocate the receiving antenna. --Increase the separation between the equipment and receiver. --Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --Consult the dealer or an experienced radio/ TV technician for help