Oase Vitronic UVC Clarifiers
Operating Instructions
For models: 11 W, 18 W, 24 W, 36 W, 55 W
Safety Information
General Warnings
- ⚠️ WARNING: Disconnect all electrical units in the water from the power supply before reaching into the water. Failure to do so may result in injuries or death by electrocution.
- This unit can be used by children aged 8 and above, and by persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, if they are supervised or have been instructed on safe use and understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.
Electrical Connection
- Special regulations apply to electrical installation in outdoor areas. Only allow a qualified electrician to perform the electrical installation.
- The qualified electrician possesses the required professional training, knowledge, and skills for electrical installations in outdoor areas and can detect potential risks while adhering to regional and national standards, regulations, and directives.
- For your own safety, please consult a qualified electrician.
- Only connect the unit if the electrical data of the unit and the power supply match.
- Only plug the unit into a correctly installed outlet. Ensure the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
- Extension cables and power distributors (e.g., outlet strips) must be suitable for outdoor use (splash-proof).
- Protect open plugs and sockets from moisture.
Safe Operation
- Do not use the unit if electrical lines or the housing are damaged.
- A damaged connection cable cannot be replaced; dispose of the unit.
- Do not carry or pull the unit by its power cable.
- Route lines so they are protected from damage and do not create tripping hazards.
- Never make technical modifications to the unit.
- Only carry out work on the unit that is described in this manual.
- Only use original spare parts and accessories.
Intended Use
- For cleaning garden ponds.
- For operation with clean water.
- Operate the product in compliance with the technical data.
Restrictions:
- This product is not suitable for general lighting; it is intended solely for the purpose described herein.
- Never operate the UVC lamp outside the casing or use it for any other purpose. The UVC radiation is harmful to the eyes and skin, even in small doses.
- Do not use for commercial or industrial purposes.
- Never run the unit without water.
- Never use the unit with fluids other than water.
- Not to be used for sterilizing drinking water or other fluids.
- Do not use in conjunction with chemicals, foodstuffs, easily flammable, or explosive substances.
Product Description
Properties
The UV radiation of the UVC clarifier removes suspended algae, bacteria, and germs. The UVC clarifier is integrated into the water circuit, ideally upstream of a pond filter.
Symbols on the Unit
- IP24: The unit is protected against splash water and against contact with dangerous components.
- ☢️ UVC radiation: Indicates dangerous UVC radiation.
- ☀️ [Sun Protection]: Protect the unit from direct sunlight.
- ? [Flammable Surface]: The lamp is suitable for direct fastening to normally flammable mounting surfaces.
- ❄️ [Frost Protection]: Protect the unit from freezing temperatures.
- ♻️ [Do Not Dispose with Household Waste]: Do not dispose of the unit with normal household waste.
- ? [Read Instructions]: Read the operating instructions.
Scope of Delivery
Diagram description: Exploded views illustrate the components for different Vitronic models, showing the unit head, casing, hose adapters, UVC lamp, and hose clips.
Description | Vitronic 11 W | Vitronic 18 W, 24 W, 36 W, 55 W |
---|---|---|
Unit head | 1 | 1 |
Casing | 1 | 1 |
Transparent stepped hose adapter with O-ring (For hose diameter 19 ... 38 mm) | 1 | 2 |
Transparent stepped hose adapter with union nut and flat seal (For hose diameter 25 ... 38 mm) | - | 2 |
UVC lamp | Pre-installed at factory | 1 |
Hose clip 20 ... 32 mm | - | 2 |
Hose clip 35 ... 50 mm | - | 2 |
Installation and Connection
Installation
- It is not necessary to remove the unit head to fasten the casing on the ground for the Vitronic 11 W. The UVC lamp is pre-installed.
- For Vitronic 18 W, 24 W, 36 W, 55 W, it is necessary to remove the unit head before fastening the casing on the ground. Refer to 'Dismantling the unit head'. The UVC lamp was not pre-installed and must be inserted into the unit head before reattaching it. Refer to 'Cleaning the quartz glass / Replacing the UVC lamp'.
Installing the Unit
- Install the unit at least 2 m from the edge of the pond.
- Only install the unit in permitted positions to ensure fault-free operation.
- Allow sufficient space for carrying out maintenance work.
Diagram description: Shows the unit positioned at least 2 meters from a pond edge. Illustrates permitted and non-permitted installation orientations (e.g., horizontal, vertical) for different Vitronic models, indicated by checkmarks (✔️) and crosses (❌).
Establishing the Connections
- Use hoses suitable for a pressure of at least 1 bar.
- Shorten the stepped hose adapters according to the hose diameter in use.
- Secure the hose with a hose clip.
- Hand-tighten the union nut of the stepped hose adapter.
- Screw the stepped hose adapter with the flat seal or O-ring onto the connection to ensure it is leak-tight.
- You can choose from the two connections arranged opposite each other to ensure optimal hose routing.
- Use the closing cap to close the connection that is not in use. The Vitronic 55 W closing cap includes an inspection glass for function checks.
Diagram description: Illustrates the process of connecting hoses to the Vitronic units using stepped hose adapters and hose clips for various models. Shows how to use the closing cap for unused connections.
Connecting the Unit to the Flow-Through Filter
The unit is suitable for connection to flow-through filters. Both outlet sockets are screwed to the inlet nozzles on the flow-through filter. Adhere to the instructions for use of the flow-through filter.
How to proceed (Vitronic 18 W, 24 W, 36 W):
- Unscrew the closing cap.
- Guide the two outlet sockets with the flat seal through the two holes in the container wall of the flow-through filter.
- Screw the inlet nozzle with the O-ring onto the outlet socket and hand-tighten the inlet nozzle.
- Connect the supply hose to the inlet socket. (Refer to 'Establishing the connections')
Diagram description: Shows the steps for connecting the Vitronic 18 W, 24 W, 36 W unit to a flow-through filter housing.
Commissioning/Start-up
Start-up Sequence:
- Switch on the pump and wait until the casing of the UVC clarifier is filled with water.
- Switch on the UVC clarifier.
- Never run the UVC clarifier without water flowing through.
- Check the UVC clarifier function.
- Check all connections for leaks.
Switching ON/OFF
- Switching on: Plug the power plug into the outlet. The unit switches on immediately.
- Switching off: Pull the power plug from the outlet.
Checking the Function
Diagram description: Shows where to observe the UV light for Vitronic 11 W and Vitronic 18 W, 24 W, 36 W, 55 W models.
Function check | Vitronic 11 W | Vitronic 18 W, 24 W, 36 W, 55 W |
---|---|---|
The function display is lit when the UVC lamp is switched on. | ✔️ | ✔️ |
The UV light shines through the transparent stepped hose adapter when the UVC lamp is switched on. | ✔️ | ✔️ |
The UV light shines through the closing cap when the UV lamp is switched on. | ❌ | ✔️ |
Maintenance and Cleaning
NOTE: Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the function of the device, and harm animals, plants, and the environment. Only clean the unit from the outside with clear water and a soft brush.
- Recommended cleaning agent for removing stubborn limescale deposits:
- Pump cleaning agent PumpClean from OASE.
- Vinegar- and chlorine-free household cleaning agent.
Dismantling the Unit Head
⚠️ CAUTION: The ultra-violet radiation of the UVC lamp can burn your eyes and skin. Never operate the UVC lamp outside the casing or in a damaged casing. Disconnect the unit from the power grid before starting any maintenance work or before replacing the UVC lamp.
⚠️ CAUTION: The quartz glass and UVC lamp could break and cause cuts. Act with caution when performing work on the UVC clarifier to avoid cuts. Avoid shocks, impacts, and abrupt movements to prevent the glass from breaking.
? For safety reasons, the UVC lamp can only be turned on when the UVC clarifier is properly installed in the unit.
How to proceed (Vitronic 11 W):
- Turn the unit head counter-clockwise up to the stop and carefully pull it out of the casing together with the O-ring.
How to proceed (Vitronic 18 W, 24 W, 36 W, 55 W):
- Push down the snap-fit hook, then turn the unit head counter-clockwise up to the stop and carefully pull the unit head out of the casing.
Diagram description: Illustrates the process of removing the unit head for Vitronic 11 W and Vitronic 18 W, 24 W, 36 W, 55 W models.
Fitting the Unit Head
How to proceed:
- Check the O-ring on the unit head for correct fit. Clean the O-ring; replace it if it is damaged.
- Carefully push the unit head into the casing up to the stop while applying slight pressure. While doing so, slightly turn the unit head to ensure that the tenons and the grooves of the bayonet closure mesh.
- Turn the unit head clockwise up to the stop.
Diagram description: Shows the steps for re-installing the unit head for Vitronic 11 W and Vitronic 18 W, 24 W, 36 W, 55 W models.
Cleaning the Quartz Glass / Replacing the UVC Lamp
Replace the UVC lamp after no more than 8000 operating hours. With constant operation, this corresponds approximately to one pond season. This ensures optimum filtering performance.
⚠️ CAUTION: The quartz glass and UVC lamp could break and cause cuts. Act with caution when performing work on the UVC clarifier to avoid cuts. Avoid shocks, impacts, and abrupt movements to prevent the glass from breaking.
Prerequisite:
- The unit head is removed. (Refer to 'Dismantling the unit head')
- Only use UVC lamps whose identification and power data correspond to the information on the type plate. (Refer to 'Technical data')
How to proceed:
- Loosen the self-tapping screw until its tip is sunk into the casing of the clamping screw.
- Carefully remove the quartz glass by pulling it forward with a slight turning movement.
- During installation, carefully push the quartz glass with the O-ring as far as the stop in the unit head. Ensure that the O-ring is located in the gap between the unit head and the quartz glass.
- Tighten the clamping screw up to the stop.
- Wipe the quartz glass with a damp cloth to remove dirt and fingerprints.
Diagram description: Illustrates the steps for removing and installing the quartz glass, including loosening a screw, removing the glass, and tightening a screw.
Storage/Overwintering
The unit is not frost-proof and must be removed and put into storage if freezing temperatures are expected.
How to correctly store the unit:
- Thoroughly clean the unit and replace damaged components.
- Store the unit in a dry and frost-free place.
Troubleshooting
Malfunction | Possible Cause | Remedy |
---|---|---|
The performance of the unit is not satisfactory | The water is extremely soiled | Remove algae and leaves from the pond. Replace the water in the pond. |
The quartz glass is soiled | Clean the quartz glass. | |
The UVC lamp has lost its filter effect | Replace the UVC lamp. The filter effect is exhausted after 8000 operating hours. | |
The flow rate is too high | Reduce the pump output. | |
The UVC lamp does not light up | The power plug is not connected | Plug the power plug into the outlet. |
The UVC lamp is defective | Replace the UVC lamp. | |
The power connection is defective | Check the electrical connection. | |
Vitronic 55 W: The UVC clarifier has shut down due to overheating | The UVC clarifier will automatically switch on again once it has cooled down. |
Technical Data
Description | Vitronic 11 W | Vitronic 18 W | Vitronic 24 W | Vitronic 36 W | Vitronic 55 W |
---|---|---|---|---|---|
Connection voltage | 220 ... 240 V AC | 220 ... 240 V AC | 220 ... 240 V AC | 220 ... 240 V AC | 220 ... 240 V AC |
Mains frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Power consumption | 14 W | 18 W | 24 W | 36 W | 55 W |
Length of power cable | 5 m | 5 m | 5 m | 5 m | 5 m |
Protection type | IP24 | IP24 | IP24 | IP24 | IP24 |
UVC lamp Type | 11 W TC-S (UV-C) | 18 W TC-S (UV-C) | 24 W TC-S (UV-C) | 36 W TC-S (UV-C) | 55 W TC-S (UV-C) |
Flow rate Max. | 1700 l/h | 3500 l/h | 4500 l/h | 6000 l/h | 8500 l/h |
Operating pressure Max. | 0.5 bar | 0.6 bar | 0.6 bar | 0.6 bar | 0.6 bar |
Connections | 3 x G1 | 3 x G1½ | 3 x G1½ | 3 x G1½ | 3 x G1½ |
Hose diameter | 19, 25, 32, 38 mm | 25, 32, 38 mm | 25, 32, 38 mm | 25, 32, 38 mm | 25, 32, 38 mm |
Suitable for max. pond volume | Without fish population: 10.0 m³ With fish population: 5.0 m³ Including koi carp: 2.5 m³ | Without fish population: 20.0 m³ With fish population: 10.0 m³ Including koi carp: 5.0 m³ | Without fish population: 25.0 m³ With fish population: 12.5 m³ Including koi carp: 6.5 m³ | Without fish population: 40.0 m³ With fish population: 20.0 m³ Including koi carp: 10.0 m³ | Without fish population: 60.0 m³ With fish population: 30.0 m³ Including koi carp: 15.0 m³ |
Dimensions Length | 330 mm | 529 mm | 529 mm | 529 mm | 660 mm |
Dimensions Width | 120 mm | 186 mm | 186 mm | 186 mm | 155 mm |
Dimensions Height | 100 mm | 130 mm | 130 mm | 130 mm | 130 mm |
Weight | 1.3 kg | 2.1 kg | 2.3 kg | 2.3 kg | 2.3 kg |
Permissible Water Values
Type | Fresh water, pond water | Pool water |
---|---|---|
pH value | 6.8 ... 8.5 | 7.2 ... 8.3 |
Hardness | 8 ... 15 DH | 8 ... 15 DH |
Free chlorine | <0.3 mg/l | <0.6 mg/l |
Chloride content | <250 mg/l | <250 mg/l |
Salt content | <0.4 % | <0.4 % |
Overall dry residue | <50 mg/l | <50 mg/l |
Temperature | +4 ... +35 °C | +4 ... +30 °C |
Wear Parts
- UVC lamp, quartz glass, and O-ring for quartz glass.
Disposal
NOTE: Do not dispose of this unit with household waste. Dispose of the UVC lamp and the unit by using the return system provided for this purpose. Render the unit unusable by cutting the cables.
OASE GmbH Contact Information
OASE GmbH
Tecklenburger Straße 161
48477 Hörstel, Germany
Phone: +49 (0) 5454 80-0
Fax: +49 (0) 5454 80-9353
Email: info@oase.com