Installation Guide for schweigen models including: Isodrive 3250 Rangehood Motors, Isodrive 3250, Rangehood Motors, Motors

Isodrive SE.3250-User Manual.

Manual

Silent Rangehood Buying Guide


File Info : application/pdf, 24 Pages, 3.12MB

PDF preview unavailable. Download the PDF instead.

66ac96446faab2933b323533 Isodrive SE.3250-Manual-v4
INSTALLATION GUIDE
Isodrive 3250

Under our policy of continuous product development, product specifications may change without notice. Please refer to the online version of the manual for the latest updates and specifications.
Revision V6 02/08/24

www.schweigen.com.au

Welcome
Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through this guide before use and installation. This guide contains important information on the correct use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your Isodrive system. Please always retain your proof of purchase to aid in any warranty queries. This appliance and its packaging are produced by processes that minimise waste and respect the environment. Please help us to continue this effort to protect the environment by using the appliance efficiently and dispose of the packaging in a responsible manner.
Page 2

Index
1. Welcome _____________________________________________________________________________________2 2. Your Safety
Receiving your rangehood ______________________________________________________________________ 4 Before Installation ______________________________________________________________________________ 4 Electrical Cord __________________________________________________________________________________ 4 Motor Features ________________________________________________________________________________ 5 General Notes on Installation and Use ____________________________________________________________ 5 Recommended Installation Distance _____________________________________________________________ 5 Minimum Mounting Height ______________________________________________________________________ 6 Avoidance of Back Flow _________________________________________________________________________ 6 Safety of Children ______________________________________________________________________________ 6 Replacement of Supply Cord _____________________________________________________________________ 6 Why Schweigen SteelFlexTM Safety Duct __________________________________________________________ 6 3. Description Isodrive Motor _________________________________________________________________________________ 7 Installation Roof Installation _______________________________________________________________________________ 8 Through Wall Installation____________________________________________________________10 Twin 200mm Outlet Installation Example (3250 kit required)_________________________________12 Optional Weather Shield Installation Guide ______________________________________________13 Optional Backdraft Shutter Installation Through Wall_______________________________________14 Optional Backdraft Shutter Installation Through Roof ______________________________________15
4. Measurements Measurements for Isodrive 3250 _____________________________________________________ 16
5. SteelFlexTM Safety Duct SteelFlexTM Safety Ducting Installation _________________________________________________ 17 Assembling SteelFlexTM Safety Duct ____________________________________________________ 18 Shallow Roof Space _______________________________________________________________ 19 Important Note __________________________________________________________________ 19 Installing SteelFlexTM Safety Duct _____________________________________________________ 20
6. Maintenance Roof Restoration or Cleaning ________________________________________________________ 21
7. Warranty/Disclaimer ________________________________________________________________________ 22
Page 3

2. Your Safety
RECEIVING YOUR RANGEHOOD
Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported within 48 hours, or no claim will be recognised. DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED. If this product is installed damaged, neither the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or reinstallation of the appliances.
This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance, it is not a toy. Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your warranty will be voided. The manufacturer declines all responsibility in case of failure to adopt proper safety measures. Ensure that the location in which this appliance is installed, has good and permanent ventilation. Please consult local laws and regulations and install in accordance. Use an electrical connector with earth that is correct for your location. Check that the voltage in your area corresponds to the appliance as indicated on the rating label.
Before Installation
We recommend this appliance to be installed or repaired by an experienced Home Appliances technician. Please see our website www.schweigen.com.au for experienced installers. It is dangerous to modify any part of this appliance. Modification of any kind, will immediately void the warranty.
Electrical Cord
Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or a similarly qualified person in order to avoid a hazard. The power supply cord connection MUST BE installed in such a way that access is easy in case of emergency.
Page 4

2. Your Safety
This guide is for the installation of the motor used in the Isodrive systems after the canopy/rangehood has been mounted on the wall or ceiling. (Refer to canopy/rangehood unit installation manual). NOTE: All PVC pipe and SteelFlexTM ducting measurements are referring to inside measurements, unless otherwise mentioned..
Motor Features
· Roof and wall mounting with IPX4 degree of weather protection. · Super quiet, long vane, backward curved centrifugal fan. · Airflow is dependant on installation and the ducting used. The result is based on the German DIN and
European EN IEC 61591:2020+A11 testing criteria for rangehood performance and is focus on the removal of contaminants from the kitchen to the external atmosphere.The use of a smaller than 250mm ducting would result in a loss of airflow. · Simple installation: The motor mounts onto a 250mm PVC pipe for ultimate strength and allows for easy Dektite roof sealing. · Industrial quality motor and fan made in Germany and rated at 40,000 hours. · Motor is a high efficiency PSC type and rated at 150W costing around the same as two 70W light globes to run. · WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not cover normal wear and tear, chemical or storm damage etc. (see warranty card for more information).
General Notes on Installation and Use
This fan unit is designed to be installed using 250mm (ISD) metal pipe as the initial connection duct to the fan module, and is supplied with a 250mm (ISD) metal pipe and 250mm (ISD) SteelFlexTM (see page 17 for installation details).
This fan is suitable for connection to multiple duct runs with a minimum inlet area of 22,000mm2. When installing, maximum 8 metres of the 250mm SteelFlexTM ducting MUST be used and no more than 2 to 3 bends in the ducting. Where possible SteelFlexTM ducting must be extended sufficiently to present a smooth air passage with bends of at least the radius of twice the diameter of the duct. Excessive bends in the ducting will compromised extraction.
WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease can occur and become a potential fire risk. This will void your warranty.
NOTE: Fan module and SteelFlexTM duct are acoustically matched. Use of semi-rigid or rigid ducting will result in increased noise and may void warranty. See installation instruction notes `Why Schweigen SteelFlexTM Safety Duct'.
Recommended Installation Distance
Isodrive 3250 motor, recommended 4 to 6 metres of SteelFlexTM ducting and with at least two bends. NOTE: Although less than 4 to 5 metres will increase extraction power this may result in a higher air noise level. Maximum duct length 8 metres (use 250mm ducting), however please be aware that increasing the duct length above 5 metre will decrease airflow. Check with supplier if longer duct length is required. Do not reduce the duct size at any time and avoid sharp bends.
Page 5

2. Your Safety
Minimum Mounting Height
This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a floor or the ground.
Avoidance of Back Flow
Care should be taken to avoid the back flow of gases into the room from the open flue of gas or other open fire appliances. Exhaust fans may adversely affect the safe operation of appliances burning gas or other fuels (including those in other rooms) due to back flow of combustion gases. These gases can potentially result in carbon monoxide poisoning. After installation of an exhaust fan such as a partition fan or a duct fan the operation of flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases does not occur.
Safety of Children
This fan is not intended for use by young children or infirm persons without supervision.
Replacement of Supply Cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualified person in order to avoid a hazard.
Why Schweigen SteelFlexTM Safety Duct
Schweigen SteelFlexTM is an ultra-strong and flexible high-performance safety ducting made of Shirikon Firemesh® ­ a tri-layer tear-resistant UV-treated sleeve. Both are developed by Schweigen ­ the Silent Rangehood specialists, for quiet and efficient high-volume transfers of temperature-sensitive air. Engineered to enhance the health and safety of your home, Schweigen SteelFlexTM is antimicrobial treated, thermally insulated and acoustically dampened. It is fireproof, pest and crush proof with a treated surface that prevents the build-up of grease and bacteria. Schweigen's unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through the hood and acoustically matched ducting, producing almost silent high volume flow. The use of a complete rigid or semi-rigid ducting system will allow an organ piping effect to occur; like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is amplified out the other. The Isodrive system places the noise outside the house. WARNING: Installation without the use of at least the minimum recommended length of acoustically matched SteelFlexTM in the system will void performance expectations. Any installation problem must be reported to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. An experienced installer list can be obtained from Schweigen website www.schweigen.com.au or by calling 1300 881 693.
Page 6

3. Description

NOTE
For more SteelFlexTM ducting instructions, refer page 17.

Isodrive Motor
Included in the box: 1. Isodrive 3250 motor
Approx. 3 metre, 10amp cable and standard plug 2. Fire resistant 250mm outside dimension metal riser pipe 3. SteelFlexTM safety ducting (250mm). Approx. 4 metres,
250mm (260mm outside dimension) diameter 4. SteelFlexTM safety ducting (200mm). Approx. 2 metres,
200mm (210mm outside dimension) diameter 5. 4 x Steel ring clamps 6. 6 x 20mm self-drilling button head screws 7. 250-200mm reducer (only use when connecting the
Isodrive 3250 motor to a single 200mm opening on a rangehood) 8. 250mm backdraft shutter 9. Wall hanging bracket

Not included in the box:

· Roof seal kit / Dektite

· Support straps for poly pipe which connects to the roof truss

· Aluminium foil tape

· Wall Mounting Kit

Included with the 3250 Kit

10

(for rangehoods with twin outlets only)

10. SteelFlexTM safety ducting. Approx. 2 metres, 200mm (210mm outside dimension) diameter
11 Y joint (250 X 200 X 200mm) 12. 2 x 200mm ring clamps

Optional:

13

13. Wall plate (AC0038) 14. Weather shield kit (AC0039)

1

2

3

4

5

6

8
7
9

11

12

14

Page 7

4. Installation Roof Installation
Recommended duct length: 3250 motor -- minimum 4 metres, optimal 4-5 metres. Mount 250mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer figure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate sealing membrane or device when installing through a metal finished roof. DO NOT install on a over lapping join. Ensure that the PVC pipe protrudes a minimum of 50mm past the top of the Dektite, checking that the fan assembly clears the roof cladding at upper edge as shown in figure 1 -- Roof Mount Option. Pass power cord and plug through mounting flange and pipe, then out the slotted PVC pipe for connection to the socket coming from the canopy/rangehood. Refer to figure 1. Do not insert plug into socket outlet or switch on until installation has been completed. Fit fan module to pipe and fix in position using side locking screw. Certain external installation configurations may cause audible levels of noise to be heard due to the air being expelled from the motor. To minimize external noise disturbance you can use between 4 to 8 metres of SteelFlexTM duct to place the Isodrive motor in an appropriate position. Please be aware that the 3250 motor is capable of expelling air at 3250m3/hr. For more information on environmental noise limit and conditions please contact your local Council. We have a list of experienced installers available on the Schweigen website. Do not install the SteelFlexTM in a straight line and minimum of two gentle bends in the ducts is required.
Page 8

3250 motor

4. Installation

Power cord 250mm Metal Pipe
Dektite
250mm SteelFlexTM duct (minimum 4 metres ducting length fully extended)

50mm Pipe protrusion above
Fix pipe to fan module with side locking screws Fit side supports to locate Strap to supports

NOTE: Prevent any cord bunching by pulling cord through from plug top end
Connect to power supply

250-200mm reducer
200mm SteelFlexTM duct MUST keep taught

Only use when connecting the motor to a single 200mm outlet on the rangehood.

Figure 1: Roof mount option
IMPORTANT
For more SteelFlexTM ducting instructions, refer page 17.
Page 9

4. Installation

Through Wall Installation

Minimum protrusion distance from wall
40mm 70mm (End of pipe)

Wall hanging bracket
Connecting pipe Wall

Recommended to fix pipe to a support structure or strapping bracket (not included in mounting kit).

ø 250mm

Ensure power cable, pipe and cover plate slot is at the bottom.

Mounting points

Power cable

Wall cover plate (Optional - Part Number AC0038)

Figure 2: Through wall installation
NOTE: Make sure that the connecting pipe is well supported, at least 2 mounting points recommended.
IMPORTANT
It is a requirement to use the hanging bracket for all wall mount installations. Please refer to the illustrations for mounting.

Page 10

Wall hanging bracket

70mm

4. Installation
Protrude pipe to distance (use as reference only)
Mounting points

Install fan unit last

Marked fastening holes first before installing

Ensure slot cover plate, power cable and pipe slot is at the bottom.

Fix pipe to structure or with a strapping bracket.
Wall cover plate (Optional - Part Number AC0038)

Figure 3: Through wall installation

Page 11

4. Installation Twin 200mm Outlet Installation Example (3250 kit required)
This is for use where one motor is to be used and there are two 200mm outlets.
3250 motor

250 x 200 x 200mm If multi-fit Y joint supplied you will need to cut to correct size.
Try to keep length of SteelFlexTM ducting as even as possible other wise motors will draw air off each other
200mm SteelFlexTM duct

250 200

200

Ensure SteelFlexTM ducting is fully extended and as short as possible. Use smooth flowing curves for maximum air flow. Remove excess ducting by trimming to length.
250mm SteelFlexTM ducting
200mm SteelFlexTM ducting 200mm outlet

Figure 4: Roof mount option

Page 12

4. Installation
Optional Weather Shield Installation Guide
Step 1
Remove Weather Shield (1 pc), Weather Shield Mounting Bracket (4 pcs) and Mounting Screws from packaging.
Step 2
Remove plastic cover from Weather Shield and bend to form a circle. Fasten 4 screws at location shown.

Step 3
Place Mounting Brackets on to Fan Guard, and fasten screws as shown. Ensure orientation of Bracket is mounted as shown.
Step 4
Repeat Step 3 for the rest of the Brackets.

4 screws

Mounting bracket screws

Fan guard

Step 5
Mount Weather Shield and align mounting holes with the Brackets, and fasten with screws (4 areas).

Align mounting holes with the brackets
Page 13

4. Installation Backdraft Shutter Installation Through Wall

3250 motor

Metal Pipe
Cut existing ducting length to minimum 400mm and assemble to the shutter system. Secure with duct tape and clamp.
Backdraft shutter system Make sure the flaps are vertical

Wall cover plate with notch at bottom (optional part) part number AC0038

Ensure that power cable passes through the cover palte notched recess and is clear of cut edge

Assemble existing ducting to the end of shutter system and secure with duct tape and clamp - see NOTE.

Minimum pipe protrusion from wall surface

Wall Wall hanging bracket

NOTE
Through wall installations flap shaft will be close to vertical and ensure flaps open towards the fan unit.

Wall cover plate (optional part) part number AC0038
Page 14

Power cord

Backdraft shutter system

Figure 6: Backdraft shutter wall mount

4. Installation
Backdraft Shutter Installation Through Roof
· Cut 250mm SteelFlexTM duct length to minimum 400mm. · Assemble by fitting shutter assembly into the ducting. · Check to ensure the flaps close and open freely before assembling the bottom end of the ducting.

3250 motor

NOTE
Ensure the flaps open upwards before assembling ducting to bottom end of the shutter system. If flaps open downwards, the assembly is incorrect.

250mm SteelFlexTM ducting

50mm

Metal riser pipe

Cut existing ducting to 150mm to 200mm length

minimum 400mm

Attach ducting to backdraft shutter and secure with duct tape and clamp
Backdraft shutter system

Assemble ducting to bottom end of backdraft shutter and secure with duct tape and clap - see NOTE.
Reducer

Figure 5: Backdraft shutter roof mount

Page 15

5. Measurements Measurements for Isodrive 3250 (Not to Scale)

Dimensions in mm

Ø400 205

290

Isodrive® 3250 weighs 8.3 kg without the Metel pipe.

50

440

Page 16

Ø250
Figure 7: Measurements for Isodrive 3250

6. SteelFlexTM Safety Duct
SteelFlexTM Safety Ducting
SteelFlexTM safety ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting results in a smaller air passage and lower airflows. Incorrect installation may reduce airflow or increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to the customer. Schweigen will take no responsibility for problems caused by faulty installation. A list of preferred installers can be obtained from the Schweigen website www.schweigen.com.au.
3250 motor

Please keep the SteelFlexTM ducting taut, 4 to 5 metres in length is optimal

NOTE: In shallow roof spaces extend flexi ducting horizontally

250mm SteelFlexTM ducting DO NOT reduce ducting size.

Reducer 200mm SteelFlexTM ducting
Figure 8: SteelFlexTM Safety Ducting

Page 17

6. SteelFlexTM Safety Duct
Assembling SteelFlexTM Safety Duct
SteelFlexTM safety duct must be secured to a 250mm mounting pipe.

Parts required: 1. SteelFlexTM safety ducting

1

2

2. Steel ring clamp

3. 20mm self-drilling button head screws

4. 250mm metal riser pipe

3

4

1. Slide the steel ring clamp over the end of the duct then insert the metal riser pipe into the duct end

2. Secure duct to the riser pipe at regular

x4

intervals with 4 x 20mm button head

screws

3. Slide the steel ring clamp back up and tighten to secure the riser pipe and the duct
Figure 9: Duct assembling NOTE: Do not use duct tape to fasten the duct ­ the screws and hose clamp are adequate to secure the duct to the riser pipe.
Page 18

6. SteelFlexTM Safety Duct
Shallow Roof Space
In shallow roof spaces, do not crush or kink SteelFlexTM ducting, as it will reduce air flow severely. 90 degree curve made of PVC or galvanise can be used as a substitute for the bend, refer to figure 10.

90 degree curve PVC or galvanise curve

250mm flexible ducting DO NOT reduce ducting size.

Important Note

Figure 10: Shallow roof space

Please do not crush or kink SteelFlexTM ducting, as it will reduce air flow and may cause noise to occur through the system. Ducting needs to be kept taut at all times.

Figure 11: SteelFlexTM duct recommended installation

Page 19

6. SteelFlexTM Safety Duct
Securing SteelFlexTM Safety Duct
SteelFlexTM safety duct must be installed with supports at maximum intervals of 1.5 metres. SteelFlexTM safety ductwork can be supported by using good quality gaffer or aluminium foil tape. Provided that it does not restrict the internal diameter of the ducting. Ducting installed looped over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual. Support of the ducting with the use of hangers may be required, see option 2. NOTE: Ducting should be kept taut at all times.

Option 1
Secure the SteelFlexTM duct to the beam

Aluminium foil tape

Option 2
Support SteelFlexTM duct by using hangers.
NOTE: Care shall be taken to minimize sagging or snaking of the duct between supports.

250mm SteelFlexTM ducting, DO NOT reduce ducting size.
Hanger Aluminium foil tape

Page 20

Figure 12: Securing SteelFlexTM Safety Duct

8. Maintenance Roof Restoration or Cleaning
Before doing your roof restoration or cleaning, please completely cover the outside motor system and avoid all chemical contact.
IMPORTANT
Any damages caused by the use of chemical products are not covered by warranty. **Images for illustration purposes only. Applies for all motors. Figure 13: Avoid chemical contact to motor system
Page 21

9. Warranty / Disclaimer Warranty (See warranty for more information)
Isodrive motor has a 10-Year replacement product warranty.* The consumer is responsible for any charges associated with removal of the faulty unit and installation of the new unit. The customer is also responsible for any freight charges incurred in this change over process. Schweigen SteelFlexTM comes with a Lifetime Warranty*.
Disclaimer
Under our policy of continuous product development, product specifications may change without notice. Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes the products being offered for sale. All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen Home Appliances will not be liable for any loss, liability or damage of whatever kind arising as a result of any reliance upon such information. All pictures used in the guide are for illustrative purposes only.
*Terms and conditions apply. Page 22

Page 23

Australia Unit 4/1-5 Lake Drive, Dingley Village, Victoria 3172. Phone 1300 881 693 Email sales@schweigen.com.au Web www.schweigen.com.au
New Zealand 5 Tolich Place, Henderson, Auckland 0610. Phone 0800 200 510 Email info.parex@emerson.com Web www.parex.co.nz



References

Adobe PDF Library 17.0 Adobe InDesign 19.5 (Windows)