ActronAir Two-Piece Fan Coil Advance Models: Specifications and Dimensions

ActronAir Two-Piece Fan Coil Advance Models - 3-Phase

The ActronAir Two-Piece Fan Coil Advance Models offer a versatile solution for challenging installation environments, featuring separate, compact, and lightweight fan and coil sections that are connected by flexible ducting. This system is designed for ease of installation in difficult roof spaces.

System Overview

The system comprises an Outdoor Unit with a power supply of 400V/3Ph + N / 50Hz and an Indoor Unit, which is split into a Fan Section and a Coil Section. These sections are connected via flexible ducting, with a maximum cable length of 7.5 meters. Ducting can be attached using 1, 2, or 3-way EASY FIT supply plenums or twin spigot duct plates, which can be fitted to either side of the units. The system supports ducting lengths between 0.0m and 6.0m.

Outdoor Unit Power Supply: 400V / 3Ph + N / 50Hz

Indoor Unit Power Supply: 230V / 1Ph + N / 50Hz

Unit Features

  • Designed for ease of installation in difficult roof spaces.
  • Mounting studs for perforated hanging strap.
  • Incorporates the EASY FIT supply & return air plenum system.
  • Reduces return air noise.
  • Integrated Primary and Safety Drain Trays.
  • Supplied with Drain Kit & P-Trap (Except Model EAA210S & EAA240S).

Model Combination Capacity Ratings and Electrical Data

Outdoor Unit Indoor Coil Section Indoor Fan Section Total Cooling Capacity (kW) Total Heating Capacity (kW) Airflow (l/s) (Min/Nom/Max) RLA (OD/ID/Total) FLA (OD/ID/Total)
CRV160T EAA160S EFV160S 14.25 14.75 600/750/900 6.0/2.2/8.2 11.9/3.2/15.1
CRV180T EAA180S EFV180S 16.30 16.70 680/850/1020 7.8/2.7/10.5 11.8/4.4/16.2
CRV210T EAA210S EFV210S 19.40 19.60 810/1020/1230 7.8/3.6/11.4 16.4/5.5/21.9
CRV240T EAA240S EFV240S 22.06 22.50 900/1130/1360 8.4/3.8/12.2 16.6/6.0/22.6

Weights and Dimensions

Coil Section

Model Weight (kg) Height (mm) Depth (mm) Width (mm)
EAA160S 29 410 342 1252
EAA180S 39 435 342 1360
EAA210S 40 486 342 1410
EAA240S 43 486 342 1410

Fan Section

Model Weight (kg) Height (mm) Depth (mm) Width (mm)
EFV160S 31 408 362 1072
EFV180S 31 408 362 1072
EFV210S 43 483 412 1269
EFV240S 43 483 412 1269

Detailed Unit Dimensions and Clearances

Fan Section Dimensions

EFV160S / EFV180S Fan Section: Overall nominal dimensions are 408mm (Height) x 1072mm (Width) x 362mm (Depth). The supply duct is 168mm (H) x 708mm (W), and the return duct is 378mm (H) x 900mm (W). Minimum service access clearances required are 800mm around the unit, with a height clearance of 340mm.

EFV210S / EFV240S Fan Section: Overall nominal dimensions are 483mm (Height) x 1269mm (Width) x 412mm (Depth). The supply duct is 200mm (H) x 714mm (W), and the return duct is 453mm (H) x 1095mm (W). Minimum service access clearances required are 890mm around the unit, with a height clearance of 410mm.

Coil Section Dimensions

EAA160S Coil Section: Overall nominal dimensions are 410mm (Height) x 1252mm (Width) x 342mm (Depth). The supply duct is 345mm (H) x 900mm (W), and the return duct is 345mm (H) x 900mm (W). It features a Gas Pipe connection of Ø19.05mm (3/4") and a Liquid Pipe connection of Ø9.52mm (3/8"). Minimum service access clearances required are 800mm around the unit, with a height clearance of 340mm.

EAA180S Coil Section: Overall nominal dimensions are 435mm (Height) x 1360mm (Width) x 342mm (Depth). The supply duct is 362mm (H) x 1094mm (W), and the return duct is 362mm (H) x 1094mm (W). It features a Gas Pipe connection of Ø22.22mm (7/8") and a Liquid Pipe connection of Ø9.52mm (3/8"). Minimum service access clearances required are 800mm around the unit, with a height clearance of 410mm.

EAA210S / EAA240S Coil Section: Overall nominal dimensions are 486mm (Height) x 1410mm (Width) x 342mm (Depth). The supply duct is 410mm (H) x 1094mm (W), and the return duct is 410mm (H) x 1094mm (W). It features a Gas Pipe connection of Ø25.4mm (1") and a Liquid Pipe connection of Ø12.7mm (1/2"). Minimum service access clearances required are 890mm around the unit, with a height clearance of 410mm.

Supply Plenum and Duct Plate Options

The system offers various supply plenum and duct plate options for connecting the fan and coil sections, ensuring compatibility with different installation requirements. These options include:

2-Way Supply Plenums

  • PL18S-2/35S: 2 x 350mm spigots
  • PL20S-2/40S: 2 x 400mm spigots
  • PL34S-2/45S: 2 x 450mm spigots

3-Way Supply Plenums

  • PL13S-3/30S: 3 x 300mm spigots
  • PL18S-3/35S: 3 x 350mm spigots
  • PL20S-3/SPS: 1 x 350mm, 1 x 400mm, 1 x 350mm spigots
  • PL22S-3/35S: 3 x 350mm spigots
  • PL30S-3/40S: 3 x 400mm spigots
  • PL34S-3/45S: 3 x 450mm spigots

Twin Spigot Duct Plates

  • PLDP-2/400: 2 x 400mm spigots
  • PLDS-2/400: 2 x 400mm spigots
  • PLDT-2/450: 2 x 450mm spigots

A compatibility matrix is available (detailed in the original document) that specifies which plenum and duct plate options are suitable for each specific model combination (EAA/EFV models).

Models: EAA160S, EAA180S, EAA210S, EAA240S, EFV160S Advance Split Ducted Unit, EFV160S, Advance Split Ducted Unit, Split Ducted Unit, Ducted Unit

File Info : application/pdf, 8 Pages, 1,007.79KB

PDF preview unavailable. Download the PDF instead.

9590-0015-09-Two-Piece-Fan-Coil-Three-Phase-Ver.-4 Adobe PDF Library 17.0 Adobe InDesign 20.2 (Windows)

Related Documents

Preview ActronAir Advance R-410A Split Ducted Indoor Unit Installation and Commissioning Guide
Comprehensive guide for installing and commissioning ActronAir Advance R-410A split ducted indoor air conditioning units. Covers safety, components, dimensions, installation procedures, airflow guidelines, electrical connections, controller options, commissioning steps, and maintenance.
Preview ActronAir ADVANCE Split Ducted Unit Troubleshooting Guide
Comprehensive troubleshooting guide for ActronAir ADVANCE Split Ducted Unit air conditioning systems, covering common faults, component diagnostics, and error code resolution.
Preview ActronAir Advance and Aires Split Ducted Units Troubleshooting Guide
A comprehensive troubleshooting guide for ActronAir Advance and Aires Split Ducted Units, covering general issues, fan troubleshooting, component diagnostics, VSD troubleshooting, and detailed fault code explanations and remedies.
Preview ActronAir Advance and Aires Split Ducted Units Troubleshooting Guide
This comprehensive troubleshooting guide provides detailed information for diagnosing and resolving issues with ActronAir Advance and Aires split ducted air conditioning systems. It covers general troubleshooting, component diagnostics, fault codes, and VSD-related problems.
Preview ActronAir MultiElite 2 Multi Split System Air Conditioner Owner's Manual
Comprehensive owner's manual for the ActronAir MultiElite 2 Multi Split System Air Conditioner, covering installation, operation, maintenance, troubleshooting, and error codes. Learn how to optimize performance and ensure safe usage of your ActronAir unit.
Preview ActronAir ActronConnect ACM-2 User Guide
Comprehensive user guide for the ActronAir ActronConnect ACM-2 remote controller, detailing setup, operation, settings, and troubleshooting for your air conditioning system.
Preview ActronAir Mini Cassette 2 Split System Air Conditioner Installation and Commissioning Guide
Comprehensive guide for the installation and commissioning of the ActronAir Mini Cassette 2 Split System Air Conditioner, covering safety, components, wiring, and testing procedures.
Preview ActronAir LC7-2 Wall Control Operation Manual
Comprehensive guide for the ActronAir LC7-2 Wall Control, detailing features, functions, programming, and maintenance for optimal air conditioning system management. Includes instructions for timers, backlights, program menus, and NFC connectivity.