User Manual for Micronet Union models including: 2A22E-X122, 2A22EX122, X122 AC1200 Dual Band XPON Terminal, X122, AC1200 Dual Band XPON Terminal, Dual Band XPON Terminal, Band XPON Terminal, XPON Terminal, Terminal

sunru

User manual

Micronet Union Technology(Chengdu) Co., Ltd. X122 2A22E-X122 2A22EX122 x122


File Info : application/pdf, 12 Pages, 331.00KB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7533555
Micronet Union
User Manual
AC1200 Dual Band XPON Terminal Model: X122
Package Content: 1. X122 *1 2. Power Adapter *1 3. Quick Installation Guide *1

Micronet Union
DECLARATION
This manual mainly introduces the function, use, operation method and so on of the products. This manual is only used as a user guide, not as a service basis. Due to continuous improvement of products, design and specifications are subject to change without notice. Products in kind prevail. For details, please check with the dealer.
PROMPT
Pictures used in this manual are for reference only. The information provided in this manual may be amended without notice, and Micronet Union reserves the right of final explanation of the said information.

Micronet Union
CONTENTS
Warnings and Precautions ....................................................................................................4 Introduction ........................................................................................................................... 5 Product Features .................................................................................................................. 5 Technical Parameters ........................................................................................................... 6 Interface and Button ..............................................................................................................7 Installation ............................................................................................................................. 8 Configuration .........................................................................................................................8 LED Description .................................................................................................................... 9 Button Description ...............................................................................................................10 Manufacture Information ..................................................................................................... 11

Micronet Union Warnings and Precautions
1. Before using and operating the equipment, please read and follow the following precautions to ensure that The standby performance is stable and dangerous or illegal situations are avoided.
2. To reduce the risk of fire or electric shock, do not expose this device to rain or moisture. The device shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on apparatus.
3. The direct plug-in adaptor is used as disconnect device, the disconnect device shall remain readily operable.
4. To reduce the risk of electric shock, do not remove cover (or back) as there are no user-serviceable parts inside. Refer servicing to qualified personnel.
5. Use only the AC adapter which is included in the product package. Any other adapter may cause damage to the device. Such damage is not covered under warranty.
6. The power adaptor is used as the power interrupting device. Please pay attention to safety plug and pull and convenient operation.
7. Do not expose the appliance to naked flame sources (for example, lighted candles).
8. Do not install the appliance in a confined space, such as a bookcase or built-in cabinet.
9. Only accessories approved by the equipment manufacturer and compatible with this type of equipment can be used. If used Other types of accessories that may violate the warranty of the equipment and the country in which the equipment is located Relevant regulations and may lead to security incidents. To obtain approved accessories, please contact the authorization Contact the service center.
10. Please use and store the equipment and its accessories within the temperature range of 0~55. When the temperature is

Micronet Union

over If the value is too high or too low, device faults may occur.

11.

Correct Disposal of this product. This marking

indicates that this product should not be disposed with

other household wastes throughout the EU. To prevent possible

harm to the environment or human health from uncontrolled

waste disposal, recycle it responsibly to promote the

sustainable reuse of material resources. To return your used

device, please use the return and collection systems or contact

the retailer or service operator where the product was

purchased. They can take this product for environmental safe

recycling.

Introduction
X122 is a gateway ONT that uses GPON/EPON technology to achieve ultra-broadband access for users. It supports 802.11ac dual-band WiFi, provides four GE Ethernet ports, one POTS voice port, and one USB port, and provides high-performance forwarding function to ensure high-quality voice, Internet, and high-definition video services.

Product Features
1. EPON/GPON dual-mode access 2. Dual band WIFI, with a physical air port speed of up to
1167Mbps 3. Supports multiple services such as internet, WiFi, voice 4. 2.5G downlink and 1.25G uplink compliant with ITU-T G.984
standard 5. Compliant with IEEE802.3ah protocol standard, supports 1.25G
symmetric rate

Micronet Union Technical Parameters

Module

Parameters

Product Size: 186mm(L)×115mm(W)×39mm(H)

Weight:

340g

Interfaces:
PON:
Ethernet: WiFi: Rated Power Input: Power Consumption

4*10/100/1000M RJ45 port 1*POTS 1*USB 2.4G Wi-Fi 5G Wi-Fi EPON&GPON mode adaptive Interface Type: SC-UPC/SC-APC Security: ONU authentication mechanism Network Coverage Radius: 20KM GPON: upstream 1.25Gbps/downstream 2.5Gbps Optical Receive Sensitivity: -7dBm~-28dBm Continuous Light Power: 0.5dBm~5dBm EPON: upstream 1.25Gbps/downstream 1.25Gbps Optical Receive Sensitivity: -7dBm~-27dBm Continuous Light Power: 0dBm~4dBm 4*10/100/1000M auto-negotiation Full/half duplex mode RJ45 connector Auto MDI/MDI-X 100M Distance Compliant with IEEE802.11b/g/n/ac 2.4GHz 2×2, 5.8GHz 2×2, 5dBi antenna Rate up to 1.167Gbps
12VDC, 1A
<12W

Micronet Union

Operating Temperature &Humidity:

Operating Temperature:0~55 Operating Humidity: 5%~95%(non-condensing)

Storage Temperature &Humidity:

Storage Temperature: -10~70 Storage Humidity: 5%~95%(non-condensing)

Buttons:

Power ON/OFF,WPS,WLAN,RESET

LED Indicators:

Power,LOS,PON,LAN1~LAN4,NET,2.4G,5G,USB, VOIP

Interface and Button

Micronet Union Installation
1. Take out the power adapter, plug the power connector into the device, and press the ON/OFF button to power on the device.
2. Connect the optical Fiber cable to the PON port. 3. Connect one end of the Ethernet cable to the LAN port, and the
other end to your personal computer.
Configuration
1. Use the SSID and Wireless password provided on the device label to establish a wireless connection. Locate the SSID on your smartphone or notebook, and enter the Wireless password when prompted to connect.
2. Press the WPS button on the device, and observe the 2.4G indicator and 5G indicator blinking alternately. Subsequently, press the WPS button on the client device. In the event of a

Micronet Union
WPS method failure, utilize the SSID and wireless password to establish a WiFi connection. 3. Open a web browser and navigate to http://192.168.1.1. Enter the default User Name and Login Password, then click Login.After successfully logging in, you can configure the settings on the web page.

LED Description

LED Status

On POWER
Off

LOS

Blinking Off

On

PON

Blinking

LAN1 -LAN4 NET
2.4G

Off
On Blinking Off On Off On Blinking Off

Description The power is on and working properly. The power is off or faulty. No optical signal is detected Optical signal is detected. A connection is set up between the ONT and its upper-layer device. The ONT attempts to set up a connection with its upper-layer device. The ONT is not connected to fibers or does not receive optical signals. LAN port is properly connected. Data are being transmitted. LAN port is not connected. At least one WAN connection is up. All WAN connections are down. 2.4GHz Wi-Fi is turned on. 2.4GHz Wi-Fi data are being transmitted. 2.4GHz Wi-Fi is turned off.

Micronet Union

On

5GHz Wi-Fi is turned on.

5G

Blinking 5GHz Wi-Fi data are being transmitted.

Off

5GHz Wi-Fi is turned off.

On

External device is connected.

USB

Blinking Data are being transmitted.

Off

No external device is connected.

On

The VOIP server has been registered.

VOIP

Blinking The voice service is in use.

Off

The VOIP server is not registered.

Button Description

Button ON/OFF
Reset
WLAN WPS

Description Turn on/off the device. Press the button for 3 to 5 seconds to reboot the device. Press the button for more than 5 seconds to restore the factory settings. Press the button for 1 to 3s to enable or disable the WLAN function. Press the button for more 1s to connect the device through WPS.

Micronet Union Manufacture Information
Manufacturer: Micronet Union Technology (Chengdu) Co., Ltd.
Address: Room 502, Building 5, No. 528, Yuefei Road, Shibantan Street, Xindu District, Chengdu, Sichuan
Micronet Union Technology (Chengdu) Co., Ltd.declares that the AC1200 Dual Band XPON Terminal is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.micronet-union.com

Micronet Union
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.



References

WPS 文字 PDFsharp 1.50.5147 (www sharp.com)