Hardware Overview
The ATEN UC232B / UC232BF is a USB to RJ-45 (RS-232) console adapter. It features:
- 1. RJ-45 Connector (female): The port for connecting the console cable.
- 2. Power LED: Indicates the device status.
- 3. USB Connector: Connects to the computer's USB port.
Installation
Follow these steps to install the UC232B / UC232BF:
- Connect the USB connector to the computer and allow the drivers to install. Note: If using an older computer without drivers, download them from the ATEN website before setup.
- Plug a straight-through Ethernet cable into the UC232B / UC232BF's RJ-45 connector.
- Connect the other end of the Ethernet cable directly to the RJ-45 console port of the target networking device.
- For connecting to a standard DB-9 serial port on the target serial device, use a rollover Ethernet cable (and an optional RJ-45 to DB-9 adapter). The maximum Ethernet cable length is 15 meters with a transmission speed up to 921.6 Kbps.
- Power on the target device.
Cable Modes
ATEN UC232B / UC232BF Console/Aux Cable Mode (DTE)
Console / Aux Port (DTE) | UC232B / UC232BF RJ-45 Port | |||
---|---|---|---|---|
Signal Type 1 | Signal Type 2 | RJ-45 Pin | Straight Cable Pin | Signal |
- | RTS | 1 | 1 | CTS |
DTR | DTR | 2 | 2 | DSR |
TxD | TxD | 3 | 3 | RxD |
GND | GND | 4 | 4 | GND |
GND | GND | 5 | 5 | GND |
RxD | RxD | 6 | 6 | TxD |
DSR | DSR | 7 | 7 | DTR |
- | CTS | 8 | 8 | RTS |
ATEN RS-232 Serial Cable Mode
3rd Party RJ-45 to RS-232 Adapter | UC232B / UC232BF RJ-45 Port | ||||
---|---|---|---|---|---|
DB-9 Out | Signal | RJ-45 Pin | Rolled Cable Pin | Signal | |
RTS | 7 | CTS | 8 | 1 | CTS |
DTR | 4 | DSR | 7 | 2 | DSR |
TxD | 3 | RxD | 6 | 3 | RxD |
GND | 5 | GND | 5 | 4 | GND |
GND | 5 | GND | 4 | 5 | GND |
RxD | 2 | TxD | 3 | 6 | TxD |
DSR | 6 | DTR | 2 | 7 | DTR |
CTS | 8 | RTS | 1 | 8 | RTS |
Cable Requirements
Straight-through Ethernet Cable Pin-outs
Signal | RJ-45 Pin | RJ-45 Pin | Signal |
---|---|---|---|
Tx+ | 1 | 1 | Tx+ |
Tx- | 2 | 2 | Tx- |
Rx+ | 3 | 3 | Rx+ |
- | 4 | 4 | - |
- | 5 | 5 | - |
Rx- | 6 | 6 | Rx- |
- | 7 | 7 | - |
- | 8 | 8 | - |
Rolled Ethernet Cable Pin-outs
Signal | RJ-45 Pin | RJ-45 Pin | Signal |
---|---|---|---|
- | 1 | 8 | - |
- | 2 | 7 | - |
- | 3 | 6 | - |
- | 4 | 5 | - |
- | 5 | 4 | - |
- | 6 | 3 | - |
- | 7 | 2 | - |
- | 8 | 1 | - |