System Specifications
This document outlines the system specifications for the Cisco Nexus 93400LD-H1 switch.
Environmental Specifications
Environment | Specification |
---|---|
Temperature | Ambient operating temperature: 32 to 104°F (0 to 40°C) Ambient nonoperating: -40 to 158°F (-40 to 70°C) |
Relative humidity | Operating: 5 to 90% Nonoperating: 5 to 95% |
Altitude | Altitude rating is 10,000 ft (3048 m). For China, it is 6,562 ft (2000 m). |
Switch Dimensions
Switch | Width | Depth | Height |
---|---|---|---|
Cisco Nexus 93400LD-H1 | 17.3 inches (43.94 cm) | 19.69 inches (50.0 cm) | 1.72 inches (4.4 cm) (1 RU) |
Switch and Module Weights and Quantities
Component | Weight per Unit | Quantity |
---|---|---|
Cisco Nexus 93400LD-H1 Chassis (N9K-C93400LD-H1) | 18.7 lb (8.48 kg) | 1 |
Fan Module | ||
- Port-side exhaust (blue) (NXA-SFAN-35CFM-PE) | 0.277 lb (0.125 kg) | 5 |
- Port-side intake (burgundy) (NXA-SFAN-35CFM-PI) | ||
Power Supply module | ||
1400-W AC port-side exhaust (blue) (NXA-PAC-1400W-PE) | 2.5 lb (1.13 kg) | 2 (1 for operations and 1 for redundancy) |
1400-W AC port-side intake (burgundy) (NXA-PAC-1400W-PI) | 2.5 lb (1.13 kg) | |
2000-W HVAC/HVDC port-side intake (burgundy) (N9K-PHV-2KW-PI) | 2.73 lb (1.23 kg) | |
2000-W DC port-side exhaust (blue) (NXA-PDC-2KW-PE) | 2.73 lb (1.23 kg) | |
2000-W DC port-side intake (burgundy) (NXA-PDC-2KW-PI) | 2.73 lb (1.23 kg) |
Transceiver and Cable Specifications
For transceiver specifications and installation information, see Cisco Transceiver Modules Support.
Switch Power Input Requirements
This table lists the typical and maximum power consumption for the switch and power supply for peak conditions.
Note: Some power supplies have capabilities greater than the maximum power requirements for a switch. Use the typical and maximum requirements listed here for power consumption characteristics.
Switch | Typical Power Consumption (AC or DC) | Maximum Power Consumption (AC or DC) | Heat Dissipation Requirement |
---|---|---|---|
Cisco Nexus 93400LD-H1 | 394 W | 765 W | 2610.288 BTU/hr |
Power Specifications
1400-W AC Power Supply Specifications
Property | Specification |
---|---|
Input Voltage Range | 100 VAC to 127 VAC 200 VAC to 240 VAC |
Input Frequency | 50 to 60 Hz |
Efficiency | 90% or greater (20 to 100% load) |
Output Power | 1,000 W/36 W (100-127 VAC) 1,400 W/36 W (200-240 VAC) |
Redundancy Modes | 1+1 |
RoHS Compliance | Yes |
Hot Swappable | Yes |
2000-W HVAC/HVDC Power Supply Specifications
These specifications apply to the NXA-PHV-2KW power supplies.
Property | Specification |
---|---|
Power | 2000 W |
Input Voltage Range | 200 to 277 VAC 240 VDC to 380 VDC |
Output Power | 2000W (36W standby) |
Frequency | 50 to 60 Hz (200 to 277 VAC) |
Efficiency | 90% or greater (20 to 100% load) |
Redundancy Modes | 1+1 |
RoHS Compliance | Yes |
Hot Swappable | Yes |
2000-W DC Power Supply Specifications
These specifications apply to the NXA-PDC-2KW power supplies.
Property | Specification |
---|---|
Power | 2000 W |
Input Voltage Range | Nominal: -48 to -60 VDC |
Frequency | - |
Efficiency | 90% or greater (20 to 100% load) |
Output Power | 2000W (36W standby) |
Redundancy Modes | 1+1 |
RoHS Compliance | Yes |
Hot Swappable | Yes |
Power Cable Specifications
These sections show the power cables that can be ordered and used with this switch.
Power Cable Specifications for AC Power Supplies
Locale | Power Cord Part Number | Cord Set Description |
---|---|---|
Global | CAB-C13-C14-2M | Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m) |
Global | CAB-C13-CBN | Cabinet jumper power cord, 250 VAC, 10 A, C14-C13 connectors, 2.3 feet (0.7 m) |
Argentina | CAB-250V-10A-AR | 250 V, 10 A, 8.2 feet (2.5 m) |
Australia | CAB-9K10A-AU | 250 VAC, 10 A, 3112 plug, 8.2 feet (2.5 m) |
Brazil | CAB-250V-10A-BR | 250 V, 10 A, 6.9 feet (2.1 m) |
European Union | CAB-9K10A-EU | 250 VAC, 10 A, CEE 7/7 plug, 8.2 feet (2.5 m) |
India | CAB-IND-10A | 10 A, 8.2 feet (2.5 m) |
India | CAB-C13-C14-2M-IN | Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m) |
India | CAB-C13-C14-3M-IN | Power Cord Jumper, C13-C14 Connectors, 9.8 feet (3.0 m) |
Israel | CAB-250V-10A-IS | 250 V, 10 A, 8.2 feet (2.5 m) |
Italy | CAB-9K10A-IT | 250 VAC, 10 A, CEI 23-16/VII plug, 8.2 feet (2.5 m) |
Japan | CAB-C13-C14-2M-JP | Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m) |
North America | CAB-9K12A-NA | 125 VAC, 13 A, NEMA 5-15 plug, 8.2 feet (2.5 m) |
North America | CAB-AC-L620-C13 | NEMA L6-20-C13, 6.6 feet (2.0 m) |
North America | CAB-N5K6A-NA | 200/240V, 6A, 8.2 feet (2.5 m) |
Peoples Republic of China | CAB-250V-10A-CN | 250 V, 10 A, 8.2 feet (2.5 m) |
South Africa | CAB-250V-10A-ID | 250 V, 10 A, 8.2 feet (2.5 m) |
Switzerland | CAB-9K10A-SW | 250 VAC, 10 A, MP232 plug, 8.2 feet (2.5 m) |
United Kingdom | CAB-9K10A-UK | 250 VAC, 10 A, BS1363 plug (13 A fuse), 8.2 (2.5 m) |
All except Argentina, Brazil, and Japan | NO-POWER-CORD | No power cord included with switch |
HVAC/HVDC Power Cables Supported by ACI-Mode and NX-OS Mode Switches
Part Number | Cord Set Description | Photo |
---|---|---|
CAB-HVAC-SD-0.6M | HVAC 2-foot (0.6 m) cable with Saf-D-Grid and SD connectors 277V AC | [Image of HVAC cable] |
CAB-HVAC-C14-2M | HVAC 6.6-foot (2.0 m) cable with Saf-D-Grid and C14 connector (use for up to 240 V) 250V AC | [Image of HVAC cable] |
CAB-HVAC-RT-0.6M | HVAC 2-foot (0.6 m) cable with Saf-D-Grid and RT connector 277V AC | [Image of HVAC cable] |
CAB-HVDC-3T-2M | HVDC 6.6-foot (2.0 m) cable with Saf-D-Grid and three terminal connectors 300V AC/400V DC (+200/-200 V DC) | [Image of HVDC cable] |
NO-POWER-CORD | All except Argentina, Brazil, and Japan No power cord included with switch | Not applicable |
Table 1: HVAC/HVDC Power Cables Callout Table
1 | Connect this end to the power supply unit. |
DC Power Cable Specifications
Part ID Number | Description | Photo |
---|---|---|
Regulatory Standards Compliance Specifications
This table lists the regulatory standards compliance for the switch.
Table 2: Regulatory Standards Compliance: Safety and EMC
Specification | Description |
---|---|
Regulatory compliance | Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC. |
Safety |
|
EMC: Emissions |
|
EMC: Immunity |
|
RoHS | The product is RoHS compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. |