User Guide for DMP models including: CELLCOMF-LTE-V, Universal LTE Fire Alarm Communicator
27 mag 2021 —
File Info : application/pdf, 13 Pages, 1.10MB
DocumentDocumentHOW-TO GUIDE: ECP PASSTHRU TABLE OF CONTENTS ECP Passthru Overview .......................................................................................... 1 Procedure............................................................................................................................................................. 1 Required Materials............................................................................................................................................ 1 Step 1:Mount the Communicator......................................................................... 2 Step 2:Wire the Communicator........................................................................... 2 Step 3:Program the Vista Keypad....................................................................... 4 Step 4:Configure ECP Settings ........................................................................... 4 Remotely (Dealer Admin).............................................................................................................................. 4 Locally (Keypad) ............................................................................................................................................... 5 Troubleshooting................................................................................................................................................. 5 Step 5:Remote Programming .............................................................................. 6 Set up Remote Link.......................................................................................................................................... 6 Add the VISTA Panel in Compass............................................................................................................... 7 Set Up Communication in Compass.......................................................................................................... 8 Configure TCP/IP Settings in Compass.................................................................................................... 9 Reference ................................................................................................................. 10 Virtual Keypad.................................................................................................................................................... 10 VISTA Panel Compatibility ............................................................................................................................ 11 ECP PASSTHRU OVERVIEW CellCom and DualCom Universal Communicators enable you to take over and manage ECP panels with connection to the ECP Bus. This feature is called ECP Passthru. This guide is designed to walk you through ECP passthru installation and setup. For more complete information, refer to the CellCom Installation Guide (LT-1817) or the DualCom Installation Guide (LT-1859). Procedure The installation must follow this procedure: Step 1: Mount the communicator. Step 2: Wire the communicator. Step 3: Program Vista keypad device address 20 Step 4: Configure ECP settings (remotely or locally) Required Materials The following software and hardware components are required to perform system takeovers: · Compatible Honeywell VISTA panel (refer to "VISTA Panel Compatibility") · CellCom or DualCom with minimum firmware Version 202 · (Optional) Programming keypad with Model 330 or Model 330-24V programming cable · (Optional) Cat 5 Ethernet cable · 18-22 AWG unshielded wire (RYGB) · Remote Link minimum Version 2.02 A Mounting Holes B Cellular Antenna C SMA Connector D Cell Modem E Tamper F Programming Connection G Terminal Block H Load and Reset Buttons I Power and Armed LEDs J Ethernet (DualCom only) B H C ETHERNET D LOAD RESET J R B PROG G F I +DC- Z1 Z2 Z3 G +Z4- O1 O2 T R E +DC- Z1 Z2 Z3 G +Z4- O1 O2 T R DC Power Zones 1 - 4 Output 1 Output 2 Tip 1 Ring 1 A CellCom or DualCom Figure 1:CellCom and DualCom Components COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 1 STEP 1:MOUNT THE COMMUNICATOR It is not necessary to remove the PCB from the housing when installing the communicator. The communicator should be mounted to a wall using the included #6 screws in the mounting holes. Refer to Figure 1 for mounting hole locations. Mount the communicator in a secure, dry place to protect it from tampering and weather damage. If using a 685 Series Conduit Backbox, refer to the 685 Installation Sheet (LT-1431) for mounting instructions. STEP 2:WIRE THE COMMUNICATOR The communicator can be connected to the ECP Bus of a VISTA panel. See Table 1 and Figure 2 for the necessary wiring connections. Caution: Remove all AC and battery power from the panels before wiring. 1. Attach the antenna to the SMA connector. Refer to Figure 1. 2. Connect system batteries as needed, then connect the panels to an appropriate power source. 3. Connect a programming keypad to the communicator. a. For 12 VDC applications, connect the keypad to the communicator PROG header with a Model 330 programming harness. b. For 24 VDC applications, connect the keypad to the communicator PROG header with a Model 330-24V programming harness with an in-line resistor. 4. After programming is complete, remove the keypad and replace the housing cover on the mounted base. Note: Address 1 is reserved by the system for programming keypads. COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 2 Communicator to ECP Wiring Com Series ECP Bus Typical Color +DC Keypad Power Red -DC Keypad GND Black Z4+ Data Out Green Z4- Data In Yellow Table 1:Wire Connections CellCom or DualCom +DC- Z1 Z2 Z3 G +Z4- O1 O2 T R RED BLACK YELLOW GREEN To Positive (5) To Negative (4) To Data Out (7) To Data In (6) OUT 17 +12 AUX GND OUT 18 BLACK RED +- 1 23 4 5 678 (USE SA4120XM-1 CABLE) SYNC COM DATA VISTA-20P VISTA 20P ONLY 1 234 + 56 + 78 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 TIP RING TIP RING (BROWN(G) RAY()GREEN)(RED) BLACK RED GREEN YELLOW HI LO LO HI HI LO LO HI HI LO LO HI HI LO LO HI From DC From DC+ From Z4From Z4+ Figure 2:ECP Wiring YELLOW GREEN RED BLACK COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 3 STEP 3:PROGRAM THE VISTA KEYPAD In this step, you will program VISTA Keypad 5 Device Address 20. This enables the VISTA panel to communicate with a CellCom or DualCom. This step must be performed locally at the VISTA panel. 1. Power down and then power up the VISTA panel. 2. Within 1 minute of powering up the VISTA panel, simultaneously press and hold the # and * buttons on the keypad. 3. The keypad displays INSTALLER CODE. Enter the installer code (default is 4112), followed by 8 0 0. 4. Enter *193, then enter 1 0. 5. To save and exit programming, enter *99. STEP 4:CONFIGURE ECP SETTINGS For the communicator to properly process data from the VISTA panel, keypad input must be set to ECP. You can perform this programming remotely with Dealer Admin or locally with a programming keypad. Remote programming requires communicators with firmware Version 212 or higher. Local configuration requires communicators with firmware Version 202 or higher. During configuration, refer to "Troubleshooting" for programming messages and troubleshooting steps. Remotely (Dealer Admin) Before programming, ensure the ECP panel's IP address is set as default. 1. Go to Customers. 2. Find and select the system name. 3. Go to Full Programming > System Options. 4. In Keypad Input, select ECP. 5. In ECP Partition, enter the number of the partition where you want the communicator to operate. 6. Press Begin ECP Setup. 7. If the host panel is a VISTA 128, turn on VISTA 128. 8. Enter the host panel's installer code in VISTA Installer Code. 9. Press Begin. 10. After setup is complete, Dealer Admin automatically retrieves zones from the host panel. If you need to retrieve zones again later, open System Options and select Get Zones. 7 8 9 4 6 10 5 COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 4 Locally (Keypad) To advance through the programming menu, press CMD. To go back, press the Back Arrow key. To enter a menu, press any select key or area. To select an option, press the select key or area under that option. Before programming, ensure the ECP panel's IP address is set as default. 1. Power up or reset the communicator. 2. At the communicator keypad, enter 6653 (PROG) and press CMD. 3. Advance to SYSTEM OPTIONS, then press any select key or area to enter the menu. 4. Advance to KYPD INPUT, then press any select key or area. 5. Select ECP by pressing the third select key or area under that option. 6. At ECP PARTN NBR, enter the number of the partition where you want the communicator to operate. Range is 1 - 8. Default is 1. 7. To save programming, advance to STOP and press any select key or area. 8. At the communicator keypad, enter 2313 (DIAG) and press CMD. 9. Advance to ECP SETUP and press any select key or area. 10. At ECP SETUP VISTA 128?: If the panel is a VISTA 128, select YES. Otherwise, select NO. 11. At INST CODE, enter the ECP panel installer code and press CMD. 12. After configuration is finished, the keypad advances to GET ZONES. Press any select key or area. As the communicator retrieves zones from the ECP panel, the number of zones is displayed and incremented as ZONE CT (zone count). Troubleshooting Message PROGRAMMING Meaning The communicator is attempting to configure ECP panel programming settings for ECP Passthru. PROGRAM SUCCESS The ECP panel has been successfully configured. Next Steps Wait for the configuration attempt to complete. Afterward, a programming status message is displayed (success, fail, or busy). Finish configuration at GET ZONES. PROGRAM FAIL The ECP panel could not be programmed. Check wiring connections and communication settings, then retry programming. BUS IS BUSY The ECP panel could not be programmed due to high ECP bus traffic. Wait and retry programming or reduce traffic on the ECP bus, then retry programming. Table 2:Programming Messages and Troubleshooting COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 5 STEP 5:REMOTE PROGRAMMING Starting with Remote LinkTM Version 1.93, you can connect a customer's Honeywell VISTA® panel with CellCom, DualCom, or iComSL Series communicators using Honeywell's Compass® software and Remote Link. Set up Remote Link The following instructions assume that you already have a basic communicator account added to your Remote Link accounts. To enable ECP Passthru for that account, complete the following steps. 1. Right-click Remote Link and select Run as administrator. 2. Double-click the communicator account to open it. 3. Go to Program > System Options. 4. To enable communication, go to Keypad input and select ECP. Press OK. 5. Go to File > Panel Information. 6. In Connection Information, enter the VISTA account number in Ecp Acct. 7. Press OK. 8. Go to ECP Passthru > ECP Start/Stop Server. 9. Minimize Remote Link. 8 6 7 COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 6 Add the VISTA Panel in Compass 1. Open Compass. 2. In the lower right corner of the Customers page, select Add. The Customer Detail window opens. 3. In Subscriber Data, enter a Receiver number and Account number. 4. In the Panel Data section, select the VISTA panel model and revision number. 5. In Network Device MAC Addr, enter FFFFFF. 6. Press OK. 3 4 5 6 COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 7 Set Up Communication in Compass 1. In Customers, double-click the account that you created in the previous section. 2. The Panel Editor opens. Go to Tools > Communications. 3. Go to File > Communication Settings. 4. Select TCPIP Port Settings. 5. To ensure that Compass uses a TCP/IP connection, select a TCP/IP port. 6. Press Add. 7. Back in Communication Settings window, select Apply. 8. Press OK. 5 6 4 8 7 COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 8 Configure TCP/IP Settings in Compass 1. In the lower left corner of the Compass Communication window, press Connect. 2. A dialog pops up to notify you that communication settings must be configured. Press OK. 3. Select Enable TCP/IP. 4. In the TCPIP Port dropdown, select the appropriate TCP/IP port. 5. Ensure that the Network Device MAC Addr is FFFFFF. 6. In Connection Mode, select ECP. 7. Ensure that AlarmNet-i is selected. 8. Press Connect. 4 3 5 6 7 8 COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 9 REFERENCE Virtual Keypad Virtual Keypad enables users to manage their systems remotely, including arming, disarming, viewing zone status, bypassing zones, view history, manage users, and more. To use Virtual Keypad for remote management, the configuration must meet the following conditions: · ECP Panels must be programmed as Stay/Away for remote arming and disarming (No Partitions). COM SERIES HOW-TO GUIDE: ECP PASSTHRU | DIGITAL MONITORING PRODUCTS 10 VISTA Panel Compatibility Panel Type ECP Remote Remote User Management Arming/Disarming Remote Zone Status VISTA-10SE Rev 15 or higher No No No VISTA-10P Yes Yes Yes Yes VISTA-15 Yes No No No VISTA-15P Yes Yes Yes Yes VISTA-20SE Rev 12 or higher No No No VISTA-20P Yes Yes Yes Yes VISTA-20PI Yes Yes Yes Yes VISTA-21iP Yes Yes Yes Yes VISTA-21iPLTE Yes Yes Yes Yes Compatible with Compass No Firmware version 2.0 or higher No Firmware version 5.2 or higher No Firmware version 5.2 or higher Firmware version 5.0 or higher Yes Yes Note: Vista 32, 40, 50, 128, 250 are not compatible with ECP Virtual Keypad and eSuite. 18205 Designed, engineered, and manufactured in Springfield, MO using U. S. and global components. LT-2209 21213 © 2021 INTRUSION · FIRE · ACCESS · NETWORKS 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 800.641.4282 | DMP. comAdobe PDF Library 15.0 Adobe InDesign 16.1 (Windows)